CPCarlo Pagani

Carlo Pagani

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Carlo Pagani has a total of 760 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Development and Characterization of Multi-Alkali Antimonide Photocathodes for High-Brightness RF Photoinjectors

    by Sandeep Kumar Mohanty, Mikhail Krasilnikov, Anne Oppelt, Frank Stephan, Daniele Sertore, Laura Monaco, Carlo Pagani, Wolfgang Hillert

    Due to their excellent photoemissive properties, especially low thermal emittance and high sensitivity in the green wavelength, multi-alkali antimonide photocathodes, in particular, cesium–potassium–antimonide, emerged as prominent photoemissive materials for the electron sources of high-repetition-rate FEL applications. To explore its feasibility of operating in a high-gradient RF gun, DESY collaborated with INFN LASA to develop multi-alkali photocathode materials. In this report, we describe the recipe of K-Cs-Sb photocathodes, which were grown on a Mo substrate by varying the foundational Sb layer thickness using sequential deposition techniques. This report also illustrates the information regarding the film thickness, substrate temperature, deposition rate, and its possible effects on the photocathode’s properties. In addition, the influence of temperature on the cathode degradation is also summarized. Furthermore, in the framework of density functional theory (DFT), we investigated the electronic and optical properties of the K2CsSb material. The optical properties, such as dielectric function, reflectivity, refracting index, and extinction coefficient, were evaluated. The correlation between the calculated and measured optical properties, such as reflectivity, provides a better and more efficient strategy to rationalize and understand the photoemissive material’s properties.


  • Open Access

    An apparatus for the continuous measurement of thickness during the electropolishing of superconducting cavities

    by M. Bertucci, A. Bosotti, R. Campari, A. D’aMbros, A. Gresele, A. T. Grimaldi, P. Michelato, L. Monaco, C. Pagani, R. Paparella, et al.

    An apparatus allowing continuous acquisition of thickness measurements during electropolishing of superconducting cavities is described. The instrument is based on the ultrasound thickness measurement technique and allows the connection of up to six probes. The apparatus has been employed to monitor the surface treatment of PIP-II low beta single cell prototypes developed and manufactured by LASA-INFN and specifically to measure surface removal at different points of interest on the cavity surface. The apparatus facilitated the development and optimization of electropolishing parameters for incorporation into the cavity manufacturing process.


  • LASA Cs2Te Photocathodes: The Electron Source for XFELs

    by Carlo Pagani, Paolo Michelato, Laura Monaco, Daniele Sertore

  • LASA Superconducting RF Cavities for Particle Accelerators

    by Carlo Pagani, Andrea Bellandi, Michele Bertucci, Andrea Bignami, Angelo Bosotti, Jin Fang Chen, Paolo Michelato, Laura Monaco, Rocco Paparella, Daniele Sertore, et al.

  • Defect detection inside superconducting 1.3 GHz cavities by means of x-ray fluorescence spectroscopy

    by M. Bertucci, P. Michelato, M. Moretti, A. Navitski, C. Pagani

    X-ray fluorescence probe for detection of foreign material inclusions on the inner surface of superconducting cavities has been developed and tested. The setup detects trace element content such as a few micrograms of impurities responsible for thermal breakdown phenomena limiting the cavity performance. The setup has been customized for the geometry of 1.3 GHz TESLA-type niobium cavities and focuses on the surface of equator area at around 103 mm from the centre axis of the cavities with around 20 mm detection spot. More precise localization of inclusions can be reconstructed by means of angular or lateral displacement of the cavity. Preliminary tests confirmed a very low detection limit for elements laying in the high efficiency spectrum zone (from 5 to 10 keV), and a high angular resolution allowing an accurate localization of defects within the equator surface.


  • Characterisation of sputter-ion pumps to be used in combination with non-evaporable getters

    by Tommaso Porcelli, Fabrizio Siviero, Gero Antonio Bongiorno, Paolo Michelato, Carlo Pagani


  • Influence of the cathode materials on the sorption of noble gases by sputter-ion pumps

    by Tommaso Porcelli, Fabrizio Siviero, Gero Antonio Bongiorno, Paolo Michelato, Carlo Pagani


  • Growth of microscopic cones on titanium cathodes of sputter-ion pumps driven by sorption of large argon quantities

    by Tommaso Porcelli, Fabrizio Siviero, Gero A. Bongiorno, Paolo Michelato, Carlo Pagani

    Microscopic cones have been observed on titanium cathodes of sputter-ion pumps (SIPs) after pump operation. The cones were studied by means of scanning electron microscopy and energy dispersive x-ray analysis. Size and morphology of these cones are clearly correlated with the nature and the relative amount of each gas species pumped by each SIP during its working life. In particular, their growth was found to be fed by sputtering mechanisms, mostly during Ar pumping, and to be driven by the electromagnetic field applied to the Penning cells of each SIP. Experimental findings suggest that the formation and extent of such conic structures on cathode surfaces might play a leading role in the onset of phenomena typically related to the functioning of SIPs, e.g., the so-called argon instability.

  • Open Access

    Study of thermal radiation shields for the ILC cryomodule

    by Norihito Ohuchi, Tug Arkan, Serena Barbanotti, Harry Carter, James Kerby, Hirotaka Nakai, Carlo Pagani, Thomas J. Peterson, Paolo Pierini, Kiyosumi Tsuchiya, et al.

    The main linacs of the International Linear Collider are composed of 1824 cryomodules. As part of the R&D on the cryomodule, simplifications of the design were considered to reduce the construction and installation costs, including the possibility of removing a portion of the 5 K thermal shield. For this investigation the heat load measurements of a 6 meter cryomodule with and without the 5 K shield were performed, and used to determine emissivity coefficients. A thermal model of a full cryomodule was then created, and the heat loads of the cryomodule with the full set of the 5 K shield and without the lower 5 K shield were calculated with these parameters. By using a modified cooling scheme for the high temperature thermal shielding, we showed that the heat loads at 2 K between two models are substantially equivalent, and indeed, the thermal model without the 5 K lower shield requires 2% less work from the refrigerator.


  • Open Access

    Detailed characterization of electron sources yielding first demonstration of European X-ray Free-Electron Laser beam quality

    by F. Stephan, C. H. Boulware, M. Krasilnikov, J. Bähr, G. Asova, A. Donat, U. Gensch, H. J. Grabosch, M. Hänel, L. Hakobyan, et al.

    The photoinjector test facility at DESY, Zeuthen site (PITZ), was built to develop and optimize photoelectron sources for superconducting linacs for high-brilliance, short-wavelength free-electron laser (FEL) applications like the free-electron laser in Hamburg (FLASH) and the European x-ray free-electron laser (XFEL). In this paper, the detailed characterization of two laser-driven rf guns with different operating conditions is described. One experimental optimization of the beam parameters was performed at an accelerating gradient of about 43  MV/m at the photocathode and the other at about 60  MV/m. In both cases, electron beams with very high phase-space density have been demonstrated at a bunch charge of 1 nC and are compared with corresponding simulations. The rf gun optimized for the lower gradient has surpassed all the FLASH requirements on beam quality and rf parameters (gradient, rf pulse length, repetition rate) and serves as a spare gun for this facility. The rf gun studied with increased accelerating gradient at the cathode produced beams with even higher brightness, yielding the first demonstration of the beam quality required for driving the European XFEL: The geometric mean of the normalized projected rms emittance in the two transverse directions was measured to be 1.26±0.13  mm mrad for a 1-nC electron bunch. When a 10% charge cut is applied excluding electrons from those phase-space regions where the measured phase-space density is below a certain level and which are not expected to contribute to the lasing process, the normalized projected rms emittance is about 0.9 mm mrad.