AGAdelheid Gauly

Adelheid Gauly

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Adelheid Gauly has a total of 137 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • A New Cycler for Automated Peritoneal Dialysis to Provide Efficient Dialysis and Improved Sleep Quality

    by Rubén Torres, Lorena Flores, Miguel Morales, Rina Morales, Eduardo Machuca, Adelheid Gauly, Saynab Atiye, Manuela Stauss-Grabo, Tatiana De Los Ríos

    Introduction: Automated peritoneal dialysis (APD) employs cyclers to control inflow and outflow of the dialysis fluid to the patient’s abdomen. To allow more patients to use this modality, cyclers should support the achievement of an adequate dialysis dose and be easy to use, cost-effective, and silent. The new SILENCIA cycler (Fresenius Medical Care, Bad Homburg, Germany), designed to improve these characteristics in comparison to its predecessor device, was evaluated in this respect in a prospective study. Methods: This cross-over study comprised two 2-week study periods, separated by a 3-week training phase. First, patients underwent APD with their current cycler (PD-NIGHT [Fresenius Medical Care, Bad Homburg, Germany] or HomeChoice Pro [Baxter, Deerfield, IL, USA] as control), followed by training on the SILENCIA cycler. Then, patients were switched to the SILENCIA cycler. During each treatment period, we collected data on total Kt/Vurea, ultrafiltration (UF) volume, patient-reported outcomes (sleep quality, among others), and device handling. Results: Sixteen patients were enrolled; 2 patients terminated the study prematurely before study intervention, 1 patient due to a protocol violation. In 13 patients, total Kt/Vurea and UF could be evaluated. Neither Kt/Vurea nor UF differed significantly between control and SILENCIA cyclers. Out of 10 patients answering the questionnaire on sleep quality after the 2-week phase with the SILENCIA cycler, sleep quality improved in 5 patients; in the other patients, sleep quality was rated unchanged compared to the previously used cycler. The average reported sleep time was 5.9 ± 1.8 h with the PD-NIGHT, 7.2 ± 2.1 h with HomeChoice Pro, and 8.0 ± 1.6 h with the SILENCIA cycler. All patients were much or very much satisfied with the new cycler. Conclusion: The SILENCIA cycler delivers adequate urea clearance and UF. Importantly, sleep quality improved, possibly related to less caution messages and alarms.


  • Open Access

    Comparison of plasma separation using centrifugation or filtration for MONET lipoprotein apheresis in patients with cardiovascular disease and severe dyslipidemia

    by Grit Waitz, Saynab Atiye, Adelheid Gauly, Heinrich Prophet

    Introduction: Homozygous or severe heterozygous familial hypercholesterolemia and elevated lipoprotein(a) levels may be treated with membrane filtration. The MONET system (Fresenius Medical Care, Bad Homburg, Germany) involves plasma separation by centrifugation or filtration.Methods: Whether the method of plasma separation affects lipoprotein lowering and treatment safety was investigated in a single‐center retrospective study.Results: The centrifugation‐based plasma separation achieved a higher plasma flow and shorter time to treat 1 L of plasma (46.2 ± 8.6 min), than the filtration‐based system (71.5 ± 40.0 min; p = 0.001). The mean reduction of LDL‐cholesterol was 69% and 67% with centrifugation and filtration and was 75% for lipoprotein(a) with both plasma separation methods. A reduction of IgM by more than 60%, of albumin and total protein by approximately 20% and low frequency of side effects was observed.Conclusions: The efficacy of lowering atherogenic lipoproteins was comparable with both plasma separation methods. Centrifugation was more time‐efficient compared to filtration.


  • Open Access

    Association of Prescription With Body Composition and Patient Outcomes in Incident Peritoneal Dialysis Patients

    by Christian Verger, Claudio Ronco, Wim Van Biesen, James Heaf, François Vrtovsnik, Manel Vera Rivera, Ilze Puide, Raymond Azar, Adelheid Gauly, Saynab Atiye, et al.

    Objective: The nutritional status of patients on peritoneal dialysis (PD) is influenced by patient- and disease-related factors and lifestyle. This analysis evaluated the association of PD prescription with body composition and patient outcomes in the prospective incident Initiative for Patient Outcomes in Dialysis–Peritoneal Dialysis (IPOD-PD) patient cohort.Design and Methods: In this observational, international cohort study with longitudinal follow-up of 1,054 incident PD patients, the association of PD prescription with body composition was analyzed by using the linear mixed models, and the association of body composition with death and change to hemodialysis (HD) by means of a competing risk analysis combined with a spline analysis. Body composition was regularly assessed with the body composition monitor, a device applying bioimpedance spectroscopy.Results: Age, time on PD, and the use of hypertonic and polyglucose solutions were significantly associated with a decrease in lean tissue index (LTI) and an increase in fat tissue index (FTI) over time. Competing risk analysis revealed a U-shaped association of body mass index (BMI) with the subdistributional hazard ratio (HR) for risk of death. High LTI was associated with a lower subdistributional HR, whereas low LTI was associated with an increased subdistributional HR when compared with the median LTI as a reference. High FTI was associated with a higher subdistributional HR when compared with the median as a reference. Subdistributional HR for risk of change to HD was not associated with any of the body composition parameters. The use of polyglucose or hypertonic PD solutions was predictive of an increased probability of change to HD, and the use of biocompatible solutions was predictive of a decreased probability of change to HD.Conclusion: Body composition is associated with non-modifiable patient-specific and modifiable treatment-related factors. The association between lean tissue and fat tissue mass and death and change to HD in patients on PD suggests developing interventions and patient counseling to improve nutritional markers and, ultimately, patient outcomes.Study Registration: The study has been registered at Clinicaltrials.gov (NCT01285726).


  • Open Access

    Advanced hemodialysis equipment for more eco-friendly dialysis

    by Adelheid Gauly, Nicole Fleck, Fatih Kircelli

    Healthcare in general and dialysis care in particular are contributing to resource consumption and, thus, have a notable environmental footprint. Dialysis is a life-saving therapy but it entails the use of a broad range of consumables generating waste, and consumption of water and energy for the dialysis process. Various stakeholders in the healthcare sector are called upon to develop and to take measures to save resources and to make healthcare and dialysis more sustainable. Among these stakeholders are manufacturers of dialysis equipment and water purification systems. Dialysis equipment and consumables, together with care processes need to be advanced to reduce waste generation, enhance recyclability, optimize water purification efficiency and water use. Joint efforts should thus pave the way to enable delivering green dialysis and to contribute to environmentally sustainable health care.


  • Performance and Hemocompatibility of a Novel Polysulfone Dialyzer: A Randomized Controlled Trial

    by Götz Ehlerding, Ansgar Erlenkötter, Adelheid Gauly, Bettina Griesshaber, James Kennedy, Lena Rauber, Wolfgang Ries, Hans Schmidt-Gürtler, Manuela Stauss-Grabo, Stephan Wagner, et al.

    Key Points: We investigated the performance and hemocompatibility of a new polysulfone hemodialyzer with enhanced membrane properties. β2-Microglobulin removal rate was noninferior to both comparator dialyzers and superior to a cellulose-acetate–based dialyzer. The dialyzer showed a favorable hemocompatibility profile on the basis of markers for complement, cell and contact activation, and coagulation. Background: High-flux dialyzers effectively remove uremic toxins, are hemocompatible to minimize intradialytic humoral and cellular stimulation, and have long-term effects on patient outcomes. A new dialyzer with a modified membrane surface has been tested for performance and hemocompatibility. Methods: This multicenter, prospective, randomized, crossover study involved the application of the new polysulfone-based FX CorAL 600 (Fresenius Medical Care, Bad Homburg, Germany), the polyarylethersulfone-based Polyflux 170H (Baxter Healthcare Corporation, Deerfield, IL), and the cellulose triacetate–based SureFlux 17UX (Nipro Medical Europe, Mechelen, Belgium), for 1 week each, to assess the noninferiority of the FX CorAL 600’s removal rate of β2-microglobulin. Performance was assessed by removal rate and clearance of small- and medium-sized molecules. Hemocompatibility was assessed through markers of complement, cell activation, contact activation, and coagulation. Results: Of 70 patients, 58 composed the intention-to-treat population. The FX CorAL 600’s removal rate of β2-microglobulin was noninferior to both comparators (PP=0.0006 versus Polyflux 170H), and superior to the SureFlux 17UX. The activation of C3a and C5a with FX CorAL 600 was significantly lower 15 minutes after treatment start than with SureFlux 17UX. The activation of sC5b-9 with FX CorAL 600 was significantly lower over the whole treatment than with SureFlux 17UX, and lower after 60 minutes than with the Polyflux 170H. The treatments with FX CorAL 600 were well tolerated. Conclusions: FX CorAL 600 efficiently removed small- and medium-sized molecules, showed a favorable hemocompatibility profile, and was associated with a low frequency of adverse events in this study, with a limited patient number and follow-up time. Further studies, with longer observation times, are warranted to provide further evidence supporting the use of the new dialyzer in a wide range of therapeutic options, and for long-term treatment of patients on hemodialysis, to minimize the potential effects on inflammatory processes.


  • Open Access

    MO387CLINICAL PERFORMANCE, HEMOCOMPATIBILITY AND SAFETY OF A NEW DIALYZER WITH A MODIFIED POLYSULFONE MEMBRANE

    by Manuela Kempkes-Koch, Manuela Stauss-Grabo, Ansgar Erlenkötter, Lena Rauber, James Kennedy, Adelheid Gauly, Hans Schmidt-Gürtler

    Background and Aims: Hemodialyzers containing membranes made from a blend of polysulfone and polyvinylpyrrolidone (PVP) are widely used. PVP makes the membrane material more hydrophilic to reduce interactions with plasma proteins and platelets. A modified spinning technique has been established to stabilize the PVP on the blood-side surface in the polysulfone dialysis membrane in the new dialyzer FX CorAL 600. The objective of the present study was to prove for this new dialyzer non-inferiority of performance in comparison to established dialyzers. Further, hemocompatibility and safety of the dialyzers were explored. Method: In a multicenter, prospective, randomized, crossover study adult patients on online hemodiafiltration (HDF) were enrolled. They were treated for one week each with on-line HDF in post-dilution mode, and in randomized order with the dialyzers FX CorAL 600, FX 600, and FX CorDiax 600 (all Fresenius Medical Care, Bad Homburg, Germany). Blood samples were taken on the midweek session before start, at the end to analyze removal rate and at 60 min to determine clearance of ß2-microglobulin, myoglobin, urea, creatinine and phosphate. Further a pattern of hemocompatibility parameters and safety was evaluated. Assuming no carry over effect, linear mixed models were used for statistical analysis. Results: The mean age of the 49 enrolled patients was 66.3±13.6 years, 76% were male. Treatments were performed in post-dilution mode with a mean blood flow > 300 mL/min and a substitution volume >19 L. The removal rate of ß2-microglobulin was 74.4, 70.4, and 73.1% for the FX CorAL 600, FX 600, and FX CorDiax 600 dialyzer, respectively. FX CorAL 600 proved to be statistically significantly non-inferior to FX 600 (p=0.0006) and to FX CorDiax 600 (p=0.036). The removal rate of FX CorAL 600 was by 4.0% (confidence interval 0.4 – 7.5%) significantly higher than with FX 600. The difference to FX CorDiax 600 was not significant. The clearance of ß2-microglobulin and myoglobin and the removal rate of myoglobin were significantly higher with the new dialyzer FX CorAL 600 than with the FX 600, and comparable to the FX CorDiax 600. Performance for small molecules was similar for all dialyzers. The complement factors C3a and C5a increased early in the treatment with a peak at 15 min, without differences between the three dialyzers for C3a, and for C5a with significantly lower increase at 15 min with FX CorAL 600 than for FX 600 (p=0.007); the difference of increase between FX CorAL 600 and FX CorDiax 600 was not significant (p=0.515). The course of sC5b9 was similar for all three dialyzers, with significantly lower increase at 15 min for both FX CorAL 600 (p=0.009) and FX CorDiax 600 (p=0.026) as compared to FX 600 and similar increase at 60 min for both FX CorAL 600 (p=0.573) and FX CorDiax 600 (p=0.386) as compared to FX 600. The area-under-the-curve for the course of sC5b-9 with FX CorAL 600 was significantly lower than with FX 600 (p=0.044) and comparable to FX CorDiax 600 (p=0.092). The leukocyte count showed a decrease in the first 15 min of the treatment, which recovered afterwards, similarly for all treatment phases with the different dialyzers. Further, the dialyzers did not differ with respect to adverse events. Conclusion: All three dialyzers showed good performance, with higher removal rates for middle molecules with the new dialyzer FX CorAL 600 compared to the FX 600. Hemocompatibility profiles were mostly similar, with lower activation of C5a and of sC5b9 with FX CorAL 600 compared to FX 600. The new dialyzer provides comparable performance levels capable of delivering adequate treatment and good tolerability for the patient.


  • Open Access

    Usability testing to evaluate user experience on cyclers for automated peritoneal dialysis

    by Thore Reitz, Stephanie Schwenke, Sebastian Hölzle, Adelheid Gauly

    Background: In the development of medical devices usability is an important aspect standing alongside performance and safety. Peritoneal dialysis (PD) can be provided by use of automated PD (APD), assisted by a cycler performing the solution exchanges. The present study has been executed to simulate training on APD cyclers to evaluate learnability and usability through established questionnaires. Methods: Usability of two APD cyclers (sleep•safe harmony, Fresenius Medical Care, Bad Homburg, Germany and HomeChoice Pro, Baxter International Inc., Deerfield (IL), USA) were evaluated with the User Experience Questionnaire (UEQ), the NASA TLX Questionnaire, and the System Usability Scale (SUS), both after training and after experience sessions. Results: Lay persons (n = 10) and health care personnel (HCPs, n = 11) participated in the study. The respondents consistently gave positive ratings in the UEQ after training and experience session. The ratings from the NASA TLX Questionnaire were mostly below 50 points indicating a low workload. Lay users and HCPs gave high ratings in the SUS evaluation both after the training and experience sessions confirming a good learnability and usability of the devices. Conclusions: The usability study to assess learnability and use-related safety revealed consistent results with all applied instruments, which demonstrated good learnability and ease-of-use of the studied APD cyclers.


  • Open Access

    Performance, clinical effectiveness, and safety of immunoadsorption in a wide range of indications

    by Kornelius Fuchs, Silke Rummler, Wolfgang Ries, Matthias Helmschrott, Jochen Selbach, Friedlinde Ernst, Christian Morath, Adelheid Gauly, Saynab Atiye, Manuela Stauss‐Grabo, et al.

    Immunoadsorption is well known to selectively remove immunoglobulins and immune complexes from plasma and is applied in a variety of autoimmune diseases and for desensitization before, or at acute rejection after organ transplantation. Performance, safety, and clinical effectiveness of immunoadsorption were the aim of this study. This prospective, noninterventional, multicentre cohort study included patients treated with immunoadsorption (Immunosorba or GLOBAFFIN adsorbers) for any indication. Clinical effectiveness was assessed after termination of the patient's individual treatment schedule. Eighty‐one patients were included, 69 were treated with Immunosorba, 11 with GLOBAFFIN, one patient with both adsorbers. A majority of patients was treated for neurological indications, dilated cardiomyopathy, and before or after kidney or heart transplantation. Mean IgG reduction from pre‐ to post‐treatment was 69.9% ± 11.5% for Immunosorba and 74.1% ± 5.0% for GLOBAFFIN, respectively. The overall IgG reduction over a complete treatment block was 68%–93% with Immunosorba and 62%–90% with GLOBAFFIN depending on the duration of the overall treatment. After termination of the immunoadsorption therapy, an improvement of clinical status was observed in 63.0%, stabilization of symptoms in 29.6%, and a deterioration in 4.9% of patients. Changes in fibrinogen, thrombocytes, and albumin were mostly classified as noncritical. Overall, the treatments were well tolerated. Immunoadsorption in routine clinical practice with both GLOBAFFIN and Immunosorba has been safely performed, was well tolerated by patients, and effective in lowering immunoglobulins with an improvement or maintenance of clinical status, thus represents an additional therapeutic option for therapy refractory immune disorders.


  • Open Access

    Less Complexity in Hemodialysis Machines Reduces Time and Physical Load for Operator Actions

    by Uwe Gründler, Eva Ekesbo, Martin Löwe, Adelheid Gauly

    Purpose: Innovative hemodialysis systems are designed to ensure user safety and reduce operational time to allow health-care personnel to focus on patient care. The 6008 CareSystem has been developed to simplify the extracorporeal circuit of the system through a disposable cassette, automate operation steps, and facilitate handling in comparison to its predecessor - the 5008 CorDiax. The present investigations were performed with the aim of evaluating usability, safety, and ergonomic aspects of the new therapy system. Methods: A time-motion study compared these two hemodialysis systems with video and time recording of handling steps required to prepare, operate, and dismantle a dialysis machine. The ergonomic burden on hands and finger joints was evaluated in a second study, again by video-recording the simulated operation of both dialysis systems. Results: The number of handling steps required for the 6008 CareSystem and critical contact points were reduced by 26% in comparison to the 5008 CorDiax for patients with arteriovenous fistula used for vascular access and by 22% for those with a catheter used for vascular access. Total process time was reduced by 2.83 and 2.57 minutes using fistulae and catheters for vascular access, respectively. The number of hand grips and finger and thumb presses was reduced by approximately 50% and required less strength to execute. Conclusion: The most recent hemodialysis system confirmed its ease of use and user safety through fewer handling steps and less physical burden on the user. Shorter operational time should enable more patient-focused care.


  • Open Access

    Integrating Monitoring of Volume Status and Blood Volume-Controlled Ultrafiltration into Extracorporeal Kidney Replacement Therapy

    by Sebastian Zschätzsch, Manuela Stauss-Grabo, Adelheid Gauly, Jennifer Braun

    Purpose: Volume management in hemodialysis (HD) requires the ability to assess volume status objectively and determine treatment strategies that achieve euvolemia without compromising hemodynamic stability. The aim of this study was to compare dialysis with and without blood volume-controlled ultrafiltration (UF) in combination with body composition monitoring, and to evaluate indicators for adequate dialysis (Kt/V), ultrafiltration volume, fluid status, and the occurrence of intradialytic morbid events (IME). Patients and Methods: Patients undergoing hemodialysis or on-line hemodiafiltration with support of a blood volume monitor (BVM) - a feedback control device integrated into the 5008 and 6008 HD systems - were enrolled. Patients received treatment for four weeks using the 6008 CAREsystem and the BVM (6008+). Data on dialysis dose (Kt/V), UF volume and predialysis fluid status were documented. This data was also documented retrospectively for four weeks with (5008+) and without (5008-) the use of the BVM with the 5008 system. Comparisons were analyzed using linear mixed models. Results: Twenty-four patients were enrolled. Kt/V was unaffected by blood volume-controlled UF (5008- vs 5008+: p=0.230) and was equally achieved with both HD systems (5008+ vs 6008+: p=0.922). The UF volume and fluid status achieved were comparable, independent of the use of UF control with BVM (5008- vs 5008+; UF volume: p=0.166; fluid overload: p=0.390) or the HD system (5008+ vs 6008+: UF volume: p=0.003; fluid overload: p=0.838), except for UF volume being higher in the 6008+ phase. IMEs occurred in less than 3% of treatments, with no difference between study phases. Conclusion: This study demonstrates that a clinical approach to kidney replacement therapy that tracks volume status and manages intradialytic fluid removal by blood volume-controlled UF delivers adequate dialysis without compromising fluid removal. It maintains volume status and ensures low incidence of IMEs.