Wenlu Cai
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Wenlu Cai has a total of 42 co-authors. Here are the top co-authors by number of shared publications:
Shejuan Xie
State Key Laboratory for Strength and Vibration of Mechanical Structures, Shaanxi Engineering Research Center of NDT and Structural Integrity Evaluation, Xi'an Jiaotong University, Xi'an 710049, People's Republic of China
6 shared publications- Zhenmao Chen
State Key Laboratory for Strength and Vibration of Mechanical Structures, Xi’an Jiaotong University, Xi’an 710049, China
6 shared publications Hong-En Chen
4 shared publicationsYong Li
4 shared publicationsZhenmao Chen
4 shared publications- Tetsuya Uchimoto
Institute of Fluid Science, Tohoku University, Sendai, Miyagi, Japan
3 shared publications
Latest Publications
- 26 November 2024
- Published by Elsevier in Ultrasonics
- Vol. 148, 107532
Temperature-compensated acoustoelastic measurements of the stress in bolts
- 26 November 2024
- Published by Elsevier in Ultrasonics
- Vol. 148, 107532
Temperature-compensated acoustoelastic measurements of the stress in bolts
- Open Access
A Study on Miniaturized In-Situ Self-Calibrated Thermometers Based on Ga and Ga-Zn Fixed Points
In order to ensure the reliability and accuracy of long-term temperature measurement where the thermometers are discommodious or even impossible to access for conventional periodical calibration, a study on miniaturized in-situ self-calibrated (MISSC) thermometers based on Ga and Ga-Zn fixed points was conducted using temperature scale transfer technology. One MISSC thermometer consists of three parts: the first is the fixed-points hardware, including a container with two cells separately filled with Ga and Ga-Zn; the second is the temperature sensing hardware, made of a Type T thermocouple; the third is the mini-power heating hardware, made of a film resistance. The measurement and calibration (M&C) system comprises a temperature measurement and data processing subsystem and a mini-power heating control subsystem. Then, an in-situ self-calibration can be carried out by mini-power heating from a room temperature of about 20 °C, and then by comparison between the measured phase transition plateau results and the standard fixed-points, i.e., Ga fixed point (about 29.76 °C) and Ga-Zn fixed point (about 25.20 °C). A series of experiments were performed, and the results show that: (1) both the proposed hardware design and the self-calibration method are feasible, and (2) the Φ16 mm × 25 mm MISSC thermometer is found to be the most miniaturized one that can realize reliable self-calibration in this study.
Open AccessA Study on Miniaturized In-Situ Self-Calibrated Thermometers Based on Ga and Ga-Zn Fixed Points
In order to ensure the reliability and accuracy of long-term temperature measurement where the thermometers are discommodious or even impossible to access for conventional periodical calibration, a study on miniaturized in-situ self-calibrated (MISSC) thermometers based on Ga and Ga-Zn fixed points was conducted using temperature scale transfer technology. One MISSC thermometer consists of three parts: the first is the fixed-points hardware, including a container with two cells separately filled with Ga and Ga-Zn; the second is the temperature sensing hardware, made of a Type T thermocouple; the third is the mini-power heating hardware, made of a film resistance. The measurement and calibration (M&C) system comprises a temperature measurement and data processing subsystem and a mini-power heating control subsystem. Then, an in-situ self-calibration can be carried out by mini-power heating from a room temperature of about 20 °C, and then by comparison between the measured phase transition plateau results and the standard fixed-points, i.e., Ga fixed point (about 29.76 °C) and Ga-Zn fixed point (about 25.20 °C). A series of experiments were performed, and the results show that: (1) both the proposed hardware design and the self-calibration method are feasible, and (2) the Φ16 mm × 25 mm MISSC thermometer is found to be the most miniaturized one that can realize reliable self-calibration in this study.
- 14 September 2020
- Published by The Royal Society in Philosophical Transactions of the Royal Society A: Mathematical, Physical and Engineering Sciences
- Vol. 378 (2182) , 20190589
Quantitative evaluation of electrical conductivity inside stress corrosion crack with electromagnetic NDE methods
This paper presents a comparison of studies on the local distributed electrical conductivity in stress corrosion crack (SCC) from signals of eddy current testing (ECT) and direct current potential drop (DCPD) aiming to improve SCC sizing accuracy when using electromagnetic non-destructive testing (NDT) methods. Experimental setups of ECT and DCPD were established, respectively, to collect measurement signals due to artificial SCCs in a plate of austenitic stainless steel. The local conductivity in the SCC region was reconstructed from the feature parameters extracted from the measured ECT and DCPD signals through inverse analyses. The inversion strategies for ECT and DCPD, each including an efficient forward simulation and an optimization scheme, were introduced from the viewpoint of conductivity reconstruction. Inversion results obtained from the measured ECT and DCPD signals showed the consistent trend which proved the validity of the predicted electrical conductivity indirectly. It is clarified that the electrical conductivity in a SCC is relatively high at the crack tip area and may become as high as 17% of that of the base material. These results provide a good reference to enhance the sizing accuracy of SCC with an electromagnetic NDT method such as ECT by updating the conductive crack model based on the results of this work. This article is part of the theme issue ‘Advanced electromagnetic non-destructive evaluation and smart monitoring’.
- 14 September 2020
- Published by The Royal Society in Philosophical Transactions of the Royal Society A: Mathematical, Physical and Engineering Sciences
- Vol. 378 (2182) , 20190589
Quantitative evaluation of electrical conductivity inside stress corrosion crack with electromagnetic NDE methods
This paper presents a comparison of studies on the local distributed electrical conductivity in stress corrosion crack (SCC) from signals of eddy current testing (ECT) and direct current potential drop (DCPD) aiming to improve SCC sizing accuracy when using electromagnetic non-destructive testing (NDT) methods. Experimental setups of ECT and DCPD were established, respectively, to collect measurement signals due to artificial SCCs in a plate of austenitic stainless steel. The local conductivity in the SCC region was reconstructed from the feature parameters extracted from the measured ECT and DCPD signals through inverse analyses. The inversion strategies for ECT and DCPD, each including an efficient forward simulation and an optimization scheme, were introduced from the viewpoint of conductivity reconstruction. Inversion results obtained from the measured ECT and DCPD signals showed the consistent trend which proved the validity of the predicted electrical conductivity indirectly. It is clarified that the electrical conductivity in a SCC is relatively high at the crack tip area and may become as high as 17% of that of the base material. These results provide a good reference to enhance the sizing accuracy of SCC with an electromagnetic NDT method such as ECT by updating the conductive crack model based on the results of this work. This article is part of the theme issue ‘Advanced electromagnetic non-destructive evaluation and smart monitoring’.
- 12 January 2018
- Published by ASTM International in Journal of Testing and Evaluation
- Vol. 46 (2) , 641-646
NDT of Cavity Defect in Metallic Plate Using dc Potential Drop Method
A zoning testing method is proposed for the nondestructive testing of cavity defects in metallic foam plates based on the principle of dc potential drop testing. The dc is injected from the two ending points of the diagonal line while the inspection signal is measured from the nodal potential of nodes at the midline of the target region. The proposed method is numerically validated in terms of its signal sensitivity to the size and the location of the defect as well as its signal interference–resistant capability to defects located in the surrounding regions. Furthermore, experimental validation is conducted, and the result shows that the proposed zoning testing method is suitable for the detection of cavity defects in practical cases.
- 12 January 2018
- Published by ASTM International in Journal of Testing and Evaluation
- Vol. 46 (2) , 641-646
NDT of Cavity Defect in Metallic Plate Using dc Potential Drop Method
A zoning testing method is proposed for the nondestructive testing of cavity defects in metallic foam plates based on the principle of dc potential drop testing. The dc is injected from the two ending points of the diagonal line while the inspection signal is measured from the nodal potential of nodes at the midline of the target region. The proposed method is numerically validated in terms of its signal sensitivity to the size and the location of the defect as well as its signal interference–resistant capability to defects located in the surrounding regions. Furthermore, experimental validation is conducted, and the result shows that the proposed zoning testing method is suitable for the detection of cavity defects in practical cases.
- 1 July 2017
- Published by Elsevier in Corrosion Science
- Vol. 123, 197-208
Assessment of local conductivity distribution in stress corrosion crack region using direct current potential drop method
- 1 July 2017
- Published by Elsevier in Corrosion Science
- Vol. 123, 197-208
Assessment of local conductivity distribution in stress corrosion crack region using direct current potential drop method
- 29 December 2016
- Published by SAGE Publications in International Journal of Applied Electromagnetics and Mechanics
- Vol. 52 (1-2) , 307-314
Sizing of defects in special shaped coolant pipe of Tokamak magnet based on eddy current testing signals
In this study, quantitative evaluation of defects in an outer-square-inner-round (OSIR), aluminium pipe, which is used as the coolant pipe of Tokamak superconducting magnet, is conducted based on the eddy current testing (ECT) technique. First, nume
- 29 December 2016
- Published by SAGE Publications in International Journal of Applied Electromagnetics and Mechanics
- Vol. 52 (1-2) , 307-314
Sizing of defects in special shaped coolant pipe of Tokamak magnet based on eddy current testing signals
In this study, quantitative evaluation of defects in an outer-square-inner-round (OSIR), aluminium pipe, which is used as the coolant pipe of Tokamak superconducting magnet, is conducted based on the eddy current testing (ECT) technique. First, nume
- 29 December 2016
- Published by SAGE Publications in International Journal of Applied Electromagnetics and Mechanics
- Vol. 52 (1-2) , 297-306
Influence of the online closure loading on the eddy current testing signals of closed fatigue crack
In this study, the strategy to simulate a real stress corrosion crack (SCC) with a closed fatigue crack (FC) in view of eddy current testing (ECT) is investigated. An online four-point bending ECT device is designed and fabricated to provide the clos
- 29 December 2016
- Published by SAGE Publications in International Journal of Applied Electromagnetics and Mechanics
- Vol. 52 (1-2) , 297-306
Influence of the online closure loading on the eddy current testing signals of closed fatigue crack
In this study, the strategy to simulate a real stress corrosion crack (SCC) with a closed fatigue crack (FC) in view of eddy current testing (ECT) is investigated. An online four-point bending ECT device is designed and fabricated to provide the clos
- 1 November 2014
- Published by SAGE Publications in International Journal of Applied Electromagnetics and Mechanics
- Vol. 46 (4) , 991-996
Comparisons of damage-induced magnetizations between austenitic stainless and carbon steel
To explore the mechanism of damage-induced magnetization for paramagnetic austenitic stainless steel, the differences of damage-induced magnetizations between an austenitic stainless steel and a carbon steel are experimentally studied. Various plastic strains are introduced into the test-pieces of the austenitic stainless steel of 304 type and S185 carbon steel material. The residual plastic strains and the damage-induced magnetic fields nearby the test-pieces, the volume fraction of the damage-induced ferromagnetic martensitic phase in austenitic stainless steel test-pieces are measured. The relationships between the residual plastic strain and the damage-induced magnetic field of two materials are investigated and their differences are compared. In addition, by establishing the relationships of the damage-induced magnetic field with the damage-induced martensitic phase, the effect of the phase transformation on the damage-induced magnetization of austenitic stainless steel is analyzed.
- 1 November 2014
- Published by SAGE Publications in International Journal of Applied Electromagnetics and Mechanics
- Vol. 46 (4) , 991-996
Comparisons of damage-induced magnetizations between austenitic stainless and carbon steel
To explore the mechanism of damage-induced magnetization for paramagnetic austenitic stainless steel, the differences of damage-induced magnetizations between an austenitic stainless steel and a carbon steel are experimentally studied. Various plastic strains are introduced into the test-pieces of the austenitic stainless steel of 304 type and S185 carbon steel material. The residual plastic strains and the damage-induced magnetic fields nearby the test-pieces, the volume fraction of the damage-induced ferromagnetic martensitic phase in austenitic stainless steel test-pieces are measured. The relationships between the residual plastic strain and the damage-induced magnetic field of two materials are investigated and their differences are compared. In addition, by establishing the relationships of the damage-induced magnetic field with the damage-induced martensitic phase, the effect of the phase transformation on the damage-induced magnetization of austenitic stainless steel is analyzed.
- 1 June 2014
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 186-189
Eddy current test research for eccentricity of international thermonuclear experimental reactor (ITER) in-vessel coils (IVCs) conductor
This paper is dedicated an eddy current test research plan in order to evaluate the eccentricity for the sandwich structure conductor used in ITER in-vessel coils. Important parameters, such as signal, frequency, lift-off effect and probe direction, are analyzed by using a numerical simulation method, and sample experiments are carried out for verification. Eventually, optimized parameters will be the result from the data analysis and the experiment carried out.
- 1 June 2014
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 186-189
Eddy current test research for eccentricity of international thermonuclear experimental reactor (ITER) in-vessel coils (IVCs) conductor
This paper is dedicated an eddy current test research plan in order to evaluate the eccentricity for the sandwich structure conductor used in ITER in-vessel coils. Important parameters, such as signal, frequency, lift-off effect and probe direction, are analyzed by using a numerical simulation method, and sample experiments are carried out for verification. Eventually, optimized parameters will be the result from the data analysis and the experiment carried out.
- 1 February 2014
- Published by SAGE Publications in International Journal of Applied Electromagnetics and Mechanics
- Vol. 45 (1-4) , 417-423
A fast forward model of pulsed eddy current inspection of multilayered tubular structures
Multilayered Tubular Structures (MTS) such as pipeline are widely employed in such industrial fields as nuclear energy, petroleum, etc. It is vital to non-destructively evaluate MTS periodically before catastrophic accidents take place. As one of the advanced Electromagnetic Nondestructive Evaluation (ENDE) techniques, Pulsed Eddy Current Testing (PECT) has been found advantageous over the other ENDE methods regarding evaluation of integrity of MTS. In this paper, a fast forward model of PECT inspection of MTS is proposed based on the analytical modeling, namely the Extended Truncated Region Eigenfunction Expansion (ETREE). The closed-form expressions of PECT signals of 3D magnetic field and coil Electromotive Force (EMF) have been formulated. The proposed model has been verified by Finite Element Modeling (FEM) and experiments. The advantages of the model in terms of high computational speed and accuracy have been identified.
- 1 February 2014
- Published by SAGE Publications in International Journal of Applied Electromagnetics and Mechanics
- Vol. 45 (1-4) , 417-423
A fast forward model of pulsed eddy current inspection of multilayered tubular structures
Multilayered Tubular Structures (MTS) such as pipeline are widely employed in such industrial fields as nuclear energy, petroleum, etc. It is vital to non-destructively evaluate MTS periodically before catastrophic accidents take place. As one of the advanced Electromagnetic Nondestructive Evaluation (ENDE) techniques, Pulsed Eddy Current Testing (PECT) has been found advantageous over the other ENDE methods regarding evaluation of integrity of MTS. In this paper, a fast forward model of PECT inspection of MTS is proposed based on the analytical modeling, namely the Extended Truncated Region Eigenfunction Expansion (ETREE). The closed-form expressions of PECT signals of 3D magnetic field and coil Electromotive Force (EMF) have been formulated. The proposed model has been verified by Finite Element Modeling (FEM) and experiments. The advantages of the model in terms of high computational speed and accuracy have been identified.