Tomohiro Kobayashi
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Tomohiro Kobayashi has a total of 53 co-authors. Here are the top co-authors by number of shared publications:
Takayuki Terai
4 shared publicationsYoshie Otake
3 shared publications- Hajime Shirai
Graduate School of Engineering, Kanagawa University 2 , Yokohama 220-8686
2 shared publications - Jun Kataoka
Waseda University
2 shared publications - Nanase Koshikawa
Faculty of Science and Engineering Waseda University Tokyo Japan
2 shared publications Noriyosu Hayashizaki
2 shared publications
Latest Publications
- 17 November 2025
- Published by International Union of Crystallography (IUCr) in Journal of Applied Crystallography
- Vol. 58 (6) , 2066-2077
Time-of-flight small-angle neutron scattering instrument ib -SAS at the compact accelerator-based neutron source RANS, dedicated to education and industrial use
We report the construction and performance of the small-angle neutron scattering instrument ib -SAS at the compact accelerator-based neutron source RANS, RIKEN, Wako, Japan. With this instrument, we aim to increase the opportunities for using neutrons for university education and/or industrial use ( e.g. screening for inferior goods). A time-of-flight method, combined with pulsed neutrons with a wide wavelength band from 1 to 10 Å, is necessary to compensate for the weak luminescence of the compact neutron source. Further enhancement has been achieved by employing a multi-pinhole collimator as a converging-beam device; 81 (= 9 × 9) pinholes select thermal neutrons emitted from the large surface area of a solid polyethylene (PE) moderator and produce a focused beam on the detector. To reduce the background originating from stray neutrons in the beam hall of RANS, we keep the path of small-angle scattering in a vacuum and cover it by a thick shield of Cd plates and PE blocks containing B 4 C powder. To cover a wide range of length scales d [or wavenumber q (= 2π/ d )], three detector blocks (small-angle, wide-angle and backward scattering) were installed on the ib -SAS instrument. The small-angle scattering obtained for glassy carbon and sodium dodecyl sulfate micelle solutions is quantitatively compared with that obtained from the iMATERIA instrument (BL20) at J-PARC, Tokai, with respect to the covered q range and the measurement efficiency and statistics. Similarly to scanning electron microscopy, the SANS instrument at RANS was used to provide a map image showing the water distribution in a mortar plate, the bottom of which was immersed in water. The incoherent scattering from hydrogen was determined and plotted as a function of height.
- 17 November 2025
- Published by International Union of Crystallography (IUCr) in Journal of Applied Crystallography
- Vol. 58 (6) , 2066-2077
Time-of-flight small-angle neutron scattering instrument ib -SAS at the compact accelerator-based neutron source RANS, dedicated to education and industrial use
We report the construction and performance of the small-angle neutron scattering instrument ib -SAS at the compact accelerator-based neutron source RANS, RIKEN, Wako, Japan. With this instrument, we aim to increase the opportunities for using neutrons for university education and/or industrial use ( e.g. screening for inferior goods). A time-of-flight method, combined with pulsed neutrons with a wide wavelength band from 1 to 10 Å, is necessary to compensate for the weak luminescence of the compact neutron source. Further enhancement has been achieved by employing a multi-pinhole collimator as a converging-beam device; 81 (= 9 × 9) pinholes select thermal neutrons emitted from the large surface area of a solid polyethylene (PE) moderator and produce a focused beam on the detector. To reduce the background originating from stray neutrons in the beam hall of RANS, we keep the path of small-angle scattering in a vacuum and cover it by a thick shield of Cd plates and PE blocks containing B 4 C powder. To cover a wide range of length scales d [or wavenumber q (= 2π/ d )], three detector blocks (small-angle, wide-angle and backward scattering) were installed on the ib -SAS instrument. The small-angle scattering obtained for glassy carbon and sodium dodecyl sulfate micelle solutions is quantitatively compared with that obtained from the iMATERIA instrument (BL20) at J-PARC, Tokai, with respect to the covered q range and the measurement efficiency and statistics. Similarly to scanning electron microscopy, the SANS instrument at RANS was used to provide a map image showing the water distribution in a mortar plate, the bottom of which was immersed in water. The incoherent scattering from hydrogen was determined and plotted as a function of height.
- 21 October 2024
- Published by AIP Publishing in Applied Physics Letters
- Vol. 125 (17)
High-contrast Compton camera: Challenges to high-quality and broadband imaging
In the field of nuclear medicine, various radiopharmaceuticals require wideband x-ray/gamma-ray imaging devices for clinical and treatment monitoring. Compton cameras, which perform imaging using high-energy gamma rays, have the potential to significantly increase the variety of radioactive nuclides that can be imaged. However, artifacts caused by the so-called “Compton cone” have hindered their clinical use. Therefore, we propose the use of a collimator to improve the contrast of images obtained using Compton cameras. In this study, we developed a high-contrast Compton camera by attaching a tungsten collimator to its front surface. The contrast is improved by applying weighting to the signals based on the distance that the high-energy gamma rays penetrated the collimator walls. As a demonstration, we visualized 198Au plates that emit 412-keV gamma rays with and without the collimator. In addition, low-energy (<200 keV) x-ray/gamma-ray imaging, which is difficult for conventional Compton cameras, was achieved by performing single-photon emission computed tomography (SPECT) using the collimator and scatterer of the Compton camera. We demonstrated broadband gamma-ray imaging by visualizing a 133Ba standard source using 81-keV and 356-keV gamma rays based on the principles of SPECT and Compton cameras, respectively.
- 21 October 2024
- Published by AIP Publishing in Applied Physics Letters
- Vol. 125 (17)
High-contrast Compton camera: Challenges to high-quality and broadband imaging
In the field of nuclear medicine, various radiopharmaceuticals require wideband x-ray/gamma-ray imaging devices for clinical and treatment monitoring. Compton cameras, which perform imaging using high-energy gamma rays, have the potential to significantly increase the variety of radioactive nuclides that can be imaged. However, artifacts caused by the so-called “Compton cone” have hindered their clinical use. Therefore, we propose the use of a collimator to improve the contrast of images obtained using Compton cameras. In this study, we developed a high-contrast Compton camera by attaching a tungsten collimator to its front surface. The contrast is improved by applying weighting to the signals based on the distance that the high-energy gamma rays penetrated the collimator walls. As a demonstration, we visualized 198Au plates that emit 412-keV gamma rays with and without the collimator. In addition, low-energy (<200 keV) x-ray/gamma-ray imaging, which is difficult for conventional Compton cameras, was achieved by performing single-photon emission computed tomography (SPECT) using the collimator and scatterer of the Compton camera. We demonstrated broadband gamma-ray imaging by visualizing a 133Ba standard source using 81-keV and 356-keV gamma rays based on the principles of SPECT and Compton cameras, respectively.
- 18 January 2023
- Published by SAGE Publications in Journal of Neutron Research
- Vol. 24 (3-4) , 421-426
Sample-motion-synchronized neutron stroboscope at RANS
A sample-motion-synchronized neutron stroboscope is developed using the RIKEN accelerator-based compact neutron source (RANS). When a sample reaches a specified rotation phase, a phase timing signal is generated, triggering a proton pulse at the proton accelerator. A neutron pulse exposes the imaging detector through the sample. By controlling the delay time between the phase signal and the proton pulse timing, the neutron exposure timing is always synchronized with the specific sample rotation phase. A sample rotating at a speed of 1800 RPM is prepared, and clear still images of neutrons are taken.
- 18 January 2023
- Published by SAGE Publications in Journal of Neutron Research
- Vol. 24 (3-4) , 421-426
Sample-motion-synchronized neutron stroboscope at RANS
A sample-motion-synchronized neutron stroboscope is developed using the RIKEN accelerator-based compact neutron source (RANS). When a sample reaches a specified rotation phase, a phase timing signal is generated, triggering a proton pulse at the proton accelerator. A neutron pulse exposes the imaging detector through the sample. By controlling the delay time between the phase signal and the proton pulse timing, the neutron exposure timing is always synchronized with the specific sample rotation phase. A sample rotating at a speed of 1800 RPM is prepared, and clear still images of neutrons are taken.
- Open Access
- 7 November 2022
- Published by AIP Publishing in Applied Physics Letters
- Vol. 121 (19) , 193701
Activation imaging of drugs with hybrid Compton camera: A proof-of-concept study
The visualization of drugs is essential for cancer treatment. Although several methods for visualizing drugs have been proposed, a versatile method that can be easily applied to various drugs has not yet been established. Therefore, we propose “activation imaging,” in which a drug is irradiated with thermal neutrons and becomes radioactive, enabling visualization using emitted x rays and/or gamma rays. Activation imaging does not require the conjugation of specific tracers with drugs. Therefore, it can be easily applied to a variety of drugs, drug carriers (e.g., metal nanoparticles), and contrast agents. In this study, neutron activation, gamma-ray spectroscopy, and imaging of drug carriers, anticancer drug, and contrast agents were performed. Gold nanoparticles (AuNPs) and platinum nanoparticles were used as drug carriers, cisplatin was used as an anticancer drug, and gadoteridol and iohexol were used as contrast agents. As a neutron source, the RIKEN accelerator-driven compact neutron source II (RANS-II) was utilized. The imaging was performed using a hybrid Compton camera (HCC). The HCC can visualize x rays and gamma rays ranging from a few keV to nearly 1 MeV, which enables the imaging of various x rays and gamma rays emitted from the activated drugs. As a result, the gamma-ray spectra indicated the generation of radioisotopes through neutron irradiation, and AuNPs and iohexol were visualized.
- 7 November 2022
- Published by AIP Publishing in Applied Physics Letters
- Vol. 121 (19) , 193701
Open AccessActivation imaging of drugs with hybrid Compton camera: A proof-of-concept study
The visualization of drugs is essential for cancer treatment. Although several methods for visualizing drugs have been proposed, a versatile method that can be easily applied to various drugs has not yet been established. Therefore, we propose “activation imaging,” in which a drug is irradiated with thermal neutrons and becomes radioactive, enabling visualization using emitted x rays and/or gamma rays. Activation imaging does not require the conjugation of specific tracers with drugs. Therefore, it can be easily applied to a variety of drugs, drug carriers (e.g., metal nanoparticles), and contrast agents. In this study, neutron activation, gamma-ray spectroscopy, and imaging of drug carriers, anticancer drug, and contrast agents were performed. Gold nanoparticles (AuNPs) and platinum nanoparticles were used as drug carriers, cisplatin was used as an anticancer drug, and gadoteridol and iohexol were used as contrast agents. As a neutron source, the RIKEN accelerator-driven compact neutron source II (RANS-II) was utilized. The imaging was performed using a hybrid Compton camera (HCC). The HCC can visualize x rays and gamma rays ranging from a few keV to nearly 1 MeV, which enables the imaging of various x rays and gamma rays emitted from the activated drugs. As a result, the gamma-ray spectra indicated the generation of radioisotopes through neutron irradiation, and AuNPs and iohexol were visualized.
- 1 December 2019
- Published by Elsevier in Nuclear Instruments and Methods in Physics Research Section B: Beam Interactions with Materials and Atoms
- Vol. 461, 186-190
Design of 500 MHz RFQ linear accelerator for a compact neutron source, RANS-III
- 1 December 2019
- Published by Elsevier in Nuclear Instruments and Methods in Physics Research Section B: Beam Interactions with Materials and Atoms
- Vol. 461, 186-190
Design of 500 MHz RFQ linear accelerator for a compact neutron source, RANS-III
- 1 December 2017
- Published by Elsevier in Surface and Coatings Technology
- Vol. 331, 206-210
Metallic particle formation by MeV proton irradiation in liquid
- 1 December 2017
- Published by Elsevier in Surface and Coatings Technology
- Vol. 331, 206-210
Metallic particle formation by MeV proton irradiation in liquid
- 1 July 2016
- Published by Elsevier in Fluid Phase Equilibria
- Vol. 420, 68-73
Determination and correlation of heat of mixing of the carbon dioxide + tert-butyl methyl ether system at 298.15 and 303.15 K and 5.0–7.0 MPa
- 1 July 2016
- Published by Elsevier in Fluid Phase Equilibria
- Vol. 420, 68-73
Determination and correlation of heat of mixing of the carbon dioxide + tert-butyl methyl ether system at 298.15 and 303.15 K and 5.0–7.0 MPa
- 1 August 2015
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 86 (8) , 085103
Single proton counting at the RIKEN cell irradiation facility
We present newly developed tapered capillaries with a scintillator window, which enable us to count single protons at the RIKEN cell irradiation setup. Their potential for performing single proton irradiation experiments at our beamline setup is demonstrated with CR39 samples, showing a single proton detection fidelity of 98%.
- 1 August 2015
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 86 (8) , 085103
Single proton counting at the RIKEN cell irradiation facility
We present newly developed tapered capillaries with a scintillator window, which enable us to count single protons at the RIKEN cell irradiation setup. Their potential for performing single proton irradiation experiments at our beamline setup is demonstrated with CR39 samples, showing a single proton detection fidelity of 98%.