Kimberly Kontson
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Research Interests
Kimberly Kontson has a total of 96 co-authors. Here are the top co-authors by number of shared publications:
Lauren Trent
Clinical Services, Advanced Arm Dynamics, Redondo Beach, CA
4 shared publicationsSophie Wang
Division of Biomedical Physics, Food and Drug Administration, Silver Spring, Maryland, United States of America
4 shared publicationsConor Bloomer
Affiliation Division of Biomedical Physics, Office of Science and Engineering Laboratories, Center for Devices and Radiological Health, Food and Drug Administration, Silver Spring, Maryland, United States of America
3 shared publicationsDavid Eguren
Office of Science and Engineering Laboratories, US Food and Drug Administration Center for Devices and Radiological Health, Silver Spring, USA
3 shared publicationsEugene F. Civillico
Department of Health and Human Services, National Institutes of Health, Bethesda, MD, USA
3 shared publicationsNaima Khan
Office of Science and Engineering Laboratories, US Food and Drug Administration Center for Devices and Radiological Health, Silver Spring, USA
3 shared publications
Latest Publications
- Open Access
- 1 August 2026
- Published by IOP Publishing in Journal of Neural Engineering
- Vol. 23 (4) , 046022
Neural correlates of performance and mental workload dynamics during learning of upper-limb body-powered and myoelectric prostheses
Objective. Despite the technological advancement of upper limb prostheses, it is unclear how device design affects the cognitive-motor processes and mental workload underlying the acquisition of dexterity skills. This study examined changes in performance and mental workload as individuals with intact upper limbs learned to use either a body-powered (BP) or a myoelectric (MYO) bypass prosthesis. Approach. Motor performance (number of blocks transported in one minute), movement smoothness, perceived mental workload (NASA-TLX), and electroencephalography theta, low-alpha, high-alpha, and beta power were examined across a 10-session prosthetic training program to assess the engagement of cognitive-motor and sensorimotor processes. Main results. While both groups revealed enhanced dexterity and movement smoothness and a decrease in perceived mental workload due to training, differences in cortical dynamics were revealed. From early to late practice, BP prosthesis users revealed an elevation of low- and high-alpha and beta power, whereas no such change was observed for MYO prosthesis users. Also, during both practice and retention, MYO prosthesis users revealed attenuated low- and high-alpha and beta power compared to the BP prosthesis users. Significance. These findings suggest that cortical dynamics for BP but not MYO device users became more refined from early to late practice, along with the latter experiencing greater arousal and recruitment of cognitive-motor and sensorimotor resources to produce a similar box and block test performance relative to the former. This work provides novel evidence of neural correlates of prosthesis-specific cognitive-motor processes underlying mental workload, offering a neurophysiological framework for improving the training and assessment of prosthesis users.
- 1 August 2026
- Published by IOP Publishing in Journal of Neural Engineering
- Vol. 23 (4) , 046022
Open AccessNeural correlates of performance and mental workload dynamics during learning of upper-limb body-powered and myoelectric prostheses
Objective. Despite the technological advancement of upper limb prostheses, it is unclear how device design affects the cognitive-motor processes and mental workload underlying the acquisition of dexterity skills. This study examined changes in performance and mental workload as individuals with intact upper limbs learned to use either a body-powered (BP) or a myoelectric (MYO) bypass prosthesis. Approach. Motor performance (number of blocks transported in one minute), movement smoothness, perceived mental workload (NASA-TLX), and electroencephalography theta, low-alpha, high-alpha, and beta power were examined across a 10-session prosthetic training program to assess the engagement of cognitive-motor and sensorimotor processes. Main results. While both groups revealed enhanced dexterity and movement smoothness and a decrease in perceived mental workload due to training, differences in cortical dynamics were revealed. From early to late practice, BP prosthesis users revealed an elevation of low- and high-alpha and beta power, whereas no such change was observed for MYO prosthesis users. Also, during both practice and retention, MYO prosthesis users revealed attenuated low- and high-alpha and beta power compared to the BP prosthesis users. Significance. These findings suggest that cortical dynamics for BP but not MYO device users became more refined from early to late practice, along with the latter experiencing greater arousal and recruitment of cognitive-motor and sensorimotor resources to produce a similar box and block test performance relative to the former. This work provides novel evidence of neural correlates of prosthesis-specific cognitive-motor processes underlying mental workload, offering a neurophysiological framework for improving the training and assessment of prosthesis users.
- Top Cited PapersOpen Access
- 12 February 2026
- Published by Springer Nature in Scientific Data
- Vol. 13 (1)
WearGait-PD: An Open-Access Wearables Dataset for Gait in Parkinson’s Disease and Age-Matched Controls
Wearable movement sensors are powerful tools for objectively characterizing and quantifying movement. They enhance the precise characterization of gait, balance, and motor symptoms in Parkinson’s disease and related disorders, facilitating in-clinic and remote assessments, disease management, and therapeutic intervention development. Access to high-quality data from these sensors can accelerate discoveries in this clinical population. The WearGait-PD open-access dataset contains raw inertial measurement unit (IMU) and sensorized insole data from 100 individuals with PD and 85 age-matched controls, synchronized to a gait walkway reference system. IMU data include 3-degree of freedom (DOF) acceleration, rotational velocity, magnetic field strength, and orientation for each of 13 sensors on the participant’s body. Sensor insole data include absolute pressure from 16 sensors in each insole and 3-DOF acceleration and rotational velocity. Walkway data include 2D position and relative pressure for each active sensor during every footfall. Frame-by-frame annotation of participant actions during gait and balance tasks was incorporated using synchronized video cameras. All data were associated with demographic information and clinical evaluations (e.g., medications, DBS-status, MDS-UPDRS scores).
- 12 February 2026
- Published by Springer Nature in Scientific Data
- Vol. 13 (1)
Top Cited PapersOpen AccessWearGait-PD: An Open-Access Wearables Dataset for Gait in Parkinson’s Disease and Age-Matched Controls
Wearable movement sensors are powerful tools for objectively characterizing and quantifying movement. They enhance the precise characterization of gait, balance, and motor symptoms in Parkinson’s disease and related disorders, facilitating in-clinic and remote assessments, disease management, and therapeutic intervention development. Access to high-quality data from these sensors can accelerate discoveries in this clinical population. The WearGait-PD open-access dataset contains raw inertial measurement unit (IMU) and sensorized insole data from 100 individuals with PD and 85 age-matched controls, synchronized to a gait walkway reference system. IMU data include 3-degree of freedom (DOF) acceleration, rotational velocity, magnetic field strength, and orientation for each of 13 sensors on the participant’s body. Sensor insole data include absolute pressure from 16 sensors in each insole and 3-DOF acceleration and rotational velocity. Walkway data include 2D position and relative pressure for each active sensor during every footfall. Frame-by-frame annotation of participant actions during gait and balance tasks was incorporated using synchronized video cameras. All data were associated with demographic information and clinical evaluations (e.g., medications, DBS-status, MDS-UPDRS scores).
- 31 October 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Journal of Biomedical and Health Informatics
- Vol. 29 (12) , 9259-9270
Deep Learning-Based Stride Segmentation With Wearable Sensors: Effects of Data Quantity, Sensor Location, and Task
Accurate stride segmentation from wearable sensors is foundational for digital gait assessment tools, yet systematic evaluations of deep learning approaches across varied mobility tasks remain limited. We developed and assessed Temporal Convolutional Network (TCN) models for stride segmentation using data from 121 older adults with and without Parkinson's disease, specifically evaluating how performance varies with model development data quantity, sensor location, and movement complexity. Using a fixed-size test set of 40 participants, we found that lower limb sensors achieved F1scores above95%duringwalking with just 5–10 training participants, but performance declined substantially during more complex movements such as 180° turns. Foot-mounted sensors maintained robust performance across tasks (F1: 99.3% walking, 96.7% turning, 88.4% stationary and transitional movements), while wrist sensors showed marked degradation (F1: 88.4% walking, 72.3% turning, 50.0% stationary and transitional movements). Our findings demonstrate that it is important to tailor performance testing for digital gait assessment tools to both sensor location and use case, as performance achieved during controlled walking may not generalize to complex movements in daily life.
- 31 October 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Journal of Biomedical and Health Informatics
- Vol. 29 (12) , 9259-9270
Deep Learning-Based Stride Segmentation With Wearable Sensors: Effects of Data Quantity, Sensor Location, and Task
Accurate stride segmentation from wearable sensors is foundational for digital gait assessment tools, yet systematic evaluations of deep learning approaches across varied mobility tasks remain limited. We developed and assessed Temporal Convolutional Network (TCN) models for stride segmentation using data from 121 older adults with and without Parkinson's disease, specifically evaluating how performance varies with model development data quantity, sensor location, and movement complexity. Using a fixed-size test set of 40 participants, we found that lower limb sensors achieved F1scores above95%duringwalking with just 5–10 training participants, but performance declined substantially during more complex movements such as 180° turns. Foot-mounted sensors maintained robust performance across tasks (F1: 99.3% walking, 96.7% turning, 88.4% stationary and transitional movements), while wrist sensors showed marked degradation (F1: 88.4% walking, 72.3% turning, 50.0% stationary and transitional movements). Our findings demonstrate that it is important to tailor performance testing for digital gait assessment tools to both sensor location and use case, as performance achieved during controlled walking may not generalize to complex movements in daily life.
- Open Access
- 13 January 2025
- Published by Elsevier in Archives of Rehabilitation Research and Clinical Translation
- Vol. 7 (3) , 100427
Test–retest Reliability, Interrater Reliability, and Convergent Validity of the Targeted Box and Block Test in an Upper Extremity Prosthesis User Population
- 13 January 2025
- Published by Elsevier in Archives of Rehabilitation Research and Clinical Translation
- Vol. 7 (3) , 100427
Open AccessTest–retest Reliability, Interrater Reliability, and Convergent Validity of the Targeted Box and Block Test in an Upper Extremity Prosthesis User Population
- Open Access
WearGait-PD: An Open-Access Wearables Dataset for Gait in Parkinson’s Disease and Age-Matched Controls
Wearable movement sensors are powerful tools for objectively characterizing and quantifying movement. They enhance the precise characterization of gait, balance, and motor symptoms in Parkinson’s disease and related disorders, facilitating in-clinic and remote assessments, disease management, and therapeutic intervention development. Access to high-quality data from these sensors can accelerate discoveries in this clinical population. The WearGait-PD open-access dataset contains raw inertial measurement unit (IMU) and sensorized insole data from individuals with PD and age-matched controls, synchronized to a gait walkway reference system. IMU data include 3-degree of freedom (DOF) acceleration, rotational velocity, magnetic field strength, and orientation for each of 13 sensors on the participant’s body. Sensor insole data include absolute pressure from 16 sensors in each insole and 3-DOF acceleration and rotational velocity. Walkway data include 2D position and relative pressure for each active sensor during every footfall. Frame-by-frame annotation of participant actions during gait and balance tasks was incorporated using synchronized video cameras. All data were associated with demographic information and clinical evaluations (e.g., medications, DBS-status, MDS-UPDRS scores).
Open AccessWearGait-PD: An Open-Access Wearables Dataset for Gait in Parkinson’s Disease and Age-Matched Controls
Wearable movement sensors are powerful tools for objectively characterizing and quantifying movement. They enhance the precise characterization of gait, balance, and motor symptoms in Parkinson’s disease and related disorders, facilitating in-clinic and remote assessments, disease management, and therapeutic intervention development. Access to high-quality data from these sensors can accelerate discoveries in this clinical population. The WearGait-PD open-access dataset contains raw inertial measurement unit (IMU) and sensorized insole data from individuals with PD and age-matched controls, synchronized to a gait walkway reference system. IMU data include 3-degree of freedom (DOF) acceleration, rotational velocity, magnetic field strength, and orientation for each of 13 sensors on the participant’s body. Sensor insole data include absolute pressure from 16 sensors in each insole and 3-DOF acceleration and rotational velocity. Walkway data include 2D position and relative pressure for each active sensor during every footfall. Frame-by-frame annotation of participant actions during gait and balance tasks was incorporated using synchronized video cameras. All data were associated with demographic information and clinical evaluations (e.g., medications, DBS-status, MDS-UPDRS scores).
- Open Access
Concurrent Validity Evidence for Pressure-Sensing Walkways Measuring Spatiotemporal Features of Gait: A Systematic Review and Meta-Analysis
Technologies that capture and analyze movement patterns for diagnostic or therapeutic purposes are a major locus of innovation in the United States. Several studies have evaluated their measurement properties in different conditions with variable findings. To date, the authors are not aware of any systematic review of studies conducted to assess the concurrent validity of pressure-sensing walkway technologies. The results of such an analysis could establish the body of evidence needed to confidently use these systems as reference or gold-standard systems when validating novel tools or measures. A comprehensive search of electronic databases including MEDLINE, Embase, and Cumulative Index to Nursing and Allied Health Literature (CINAHL) was performed. The initial search yielded 7670 papers. After removing duplicates and applying study inclusion/exclusion criteria, 11 papers were included in the systematic review with 10 included in a meta-analysis. There were 25 spatial and temporal gait parameters extracted from the included studies. The results showed there was not a significant bias for nearly all spatiotemporal gait parameters when the walkway system was compared to the reference systems. The findings from this analysis should provide confidence in using the walkway systems as reference systems in future studies to support the evaluation and validation of novel technologies deriving gait parameters.
Open AccessConcurrent Validity Evidence for Pressure-Sensing Walkways Measuring Spatiotemporal Features of Gait: A Systematic Review and Meta-Analysis
Technologies that capture and analyze movement patterns for diagnostic or therapeutic purposes are a major locus of innovation in the United States. Several studies have evaluated their measurement properties in different conditions with variable findings. To date, the authors are not aware of any systematic review of studies conducted to assess the concurrent validity of pressure-sensing walkway technologies. The results of such an analysis could establish the body of evidence needed to confidently use these systems as reference or gold-standard systems when validating novel tools or measures. A comprehensive search of electronic databases including MEDLINE, Embase, and Cumulative Index to Nursing and Allied Health Literature (CINAHL) was performed. The initial search yielded 7670 papers. After removing duplicates and applying study inclusion/exclusion criteria, 11 papers were included in the systematic review with 10 included in a meta-analysis. There were 25 spatial and temporal gait parameters extracted from the included studies. The results showed there was not a significant bias for nearly all spatiotemporal gait parameters when the walkway system was compared to the reference systems. The findings from this analysis should provide confidence in using the walkway systems as reference systems in future studies to support the evaluation and validation of novel technologies deriving gait parameters.
- Open Access
- 9 May 2023
- Published by MDPI AG in Multimodal Technologies and Interaction
- Vol. 7 (5) , 49
Usability Assessments for Augmented Reality Head-Mounted Displays in Open Surgery and Interventional Procedures: A Systematic Review
Augmented reality (AR) head-mounted displays (HMDs) are an increasingly popular technology. For surgical applications, the use of AR HMDs to display medical images or models may reduce invasiveness and improve task performance by enhancing understanding of the underlying anatomy. This technology may be particularly beneficial in open surgeries and interventional procedures for which the use of endoscopes, microscopes, or other visualization tools is insufficient or infeasible. While the capabilities of AR HMDs are promising, their usability for surgery is not well-defined. This review identifies current trends in the literature, including device types, surgical specialties, and reporting of user demographics, and provides a description of usability assessments of AR HMDs for open surgeries and interventional procedures. Assessments applied to other extended reality technologies are included to identify additional usability assessments for consideration when assessing AR HMDs. The PubMed, Web of Science, and EMBASE databases were searched through September 2022 for relevant articles that described user studies. User assessments most often addressed task performance. However, objective measurements of cognitive, visual, and physical loads, known to affect task performance and the occurrence of adverse events, were limited. There was also incomplete reporting of user demographics. This review reveals knowledge and methodology gaps for usability of AR HMDs and demonstrates the potential impact of future usability research.
- 9 May 2023
- Published by MDPI AG in Multimodal Technologies and Interaction
- Vol. 7 (5) , 49
Open AccessUsability Assessments for Augmented Reality Head-Mounted Displays in Open Surgery and Interventional Procedures: A Systematic Review
Augmented reality (AR) head-mounted displays (HMDs) are an increasingly popular technology. For surgical applications, the use of AR HMDs to display medical images or models may reduce invasiveness and improve task performance by enhancing understanding of the underlying anatomy. This technology may be particularly beneficial in open surgeries and interventional procedures for which the use of endoscopes, microscopes, or other visualization tools is insufficient or infeasible. While the capabilities of AR HMDs are promising, their usability for surgery is not well-defined. This review identifies current trends in the literature, including device types, surgical specialties, and reporting of user demographics, and provides a description of usability assessments of AR HMDs for open surgeries and interventional procedures. Assessments applied to other extended reality technologies are included to identify additional usability assessments for consideration when assessing AR HMDs. The PubMed, Web of Science, and EMBASE databases were searched through September 2022 for relevant articles that described user studies. User assessments most often addressed task performance. However, objective measurements of cognitive, visual, and physical loads, known to affect task performance and the occurrence of adverse events, were limited. There was also incomplete reporting of user demographics. This review reveals knowledge and methodology gaps for usability of AR HMDs and demonstrates the potential impact of future usability research.
- Open Access
Comparison of Motion Analysis Systems in Tracking Upper Body Movement of Myoelectric Bypass Prosthesis Users
Current literature lacks a comparative analysis of different motion capture systems for tracking upper limb (UL) movement as individuals perform standard tasks. To better understand the performance of various motion capture systems in quantifying UL movement in the prosthesis user population, this study compares joint angles derived from three systems that vary in cost and motion capture mechanisms: a marker-based system (Vicon), an inertial measurement unit system (Xsens), and a markerless system (Kinect). Ten healthy participants (5F/5M; 29.6 ± 7.1 years) were trained with a TouchBionic i-Limb Ultra myoelectric terminal device mounted on a bypass prosthetic device. Participants were simultaneously recorded with all systems as they performed standardized tasks. Root mean square error and bias values for degrees of freedom in the right elbow, shoulder, neck, and torso were calculated. The IMU system yielded more accurate kinematics for shoulder, neck, and torso angles while the markerless system performed better for the elbow angles. By evaluating the ability of each system to capture kinematic changes of simulated upper limb prosthesis users during a variety of standardized tasks, this study provides insight into the advantages and limitations of using different motion capture technologies for upper limb functional assessment.
Open AccessComparison of Motion Analysis Systems in Tracking Upper Body Movement of Myoelectric Bypass Prosthesis Users
Current literature lacks a comparative analysis of different motion capture systems for tracking upper limb (UL) movement as individuals perform standard tasks. To better understand the performance of various motion capture systems in quantifying UL movement in the prosthesis user population, this study compares joint angles derived from three systems that vary in cost and motion capture mechanisms: a marker-based system (Vicon), an inertial measurement unit system (Xsens), and a markerless system (Kinect). Ten healthy participants (5F/5M; 29.6 ± 7.1 years) were trained with a TouchBionic i-Limb Ultra myoelectric terminal device mounted on a bypass prosthetic device. Participants were simultaneously recorded with all systems as they performed standardized tasks. Root mean square error and bias values for degrees of freedom in the right elbow, shoulder, neck, and torso were calculated. The IMU system yielded more accurate kinematics for shoulder, neck, and torso angles while the markerless system performed better for the elbow angles. By evaluating the ability of each system to capture kinematic changes of simulated upper limb prosthesis users during a variety of standardized tasks, this study provides insight into the advantages and limitations of using different motion capture technologies for upper limb functional assessment.
- Open Access
Factors influencing perceived function in the upper limb prosthesis user population
Introduction Patient-reported outcomes (PROs) can be used to evaluate perceived capacity of an individual in executing tasks in a natural environment with their prosthetic device. According to the World Health Organization International Classification of Health, Functioning, and Disability (ICF) models, there may be specific factors of a person, factors of assistive prosthetic technology, or factors related to the health condition or body function that impact their functioning and disability. However, an understanding of factors impacting an upper limb prosthesis user's perception of their ability to execute tasks in a natural environment is not well established. Objective Use the ICF model to identify which health condition-related, body function, environmental, and personal factors influence activity as measured by perceived function in the upper limb prosthesis user population. Design Quantitative clinical descriptive study Setting Clinical offices within outpatient private practice (Removed for blinding) Participants A sample of 101 participants with upper limb amputation who use a prosthetic device and were undergoing a prosthesis fitting process. Interventions Not applicable. Main Outcome Measures: PROs on pain with/without a prosthesis, satisfaction, and perceived function derived from the Comprehensive Arm Prosthesis and Rehabilitation Outcomes Questionnaire. Results Model coefficients indicate that with a unit increase in satisfaction (p < 0.001) and pain (p = 0.031) scores (with higher pain scores signifying less pain), the mean of perceived function increases by 0.66 and 0.47 units, respectively. Conversely, for individuals with elbow disarticulation, transhumeral, shoulder disarticulation, and interscapulothoracic amputations, the mean of perceived function decreases by 22.02 units (p = 0.006). Conclusions Based on our sample, perceived function is significantly associated with satisfaction, pain, and amputation level. These findings could potentially help to inform initial clinical approach and targeted outcomes for patients based on these factors.
Open AccessFactors influencing perceived function in the upper limb prosthesis user population
Introduction Patient-reported outcomes (PROs) can be used to evaluate perceived capacity of an individual in executing tasks in a natural environment with their prosthetic device. According to the World Health Organization International Classification of Health, Functioning, and Disability (ICF) models, there may be specific factors of a person, factors of assistive prosthetic technology, or factors related to the health condition or body function that impact their functioning and disability. However, an understanding of factors impacting an upper limb prosthesis user's perception of their ability to execute tasks in a natural environment is not well established. Objective Use the ICF model to identify which health condition-related, body function, environmental, and personal factors influence activity as measured by perceived function in the upper limb prosthesis user population. Design Quantitative clinical descriptive study Setting Clinical offices within outpatient private practice (Removed for blinding) Participants A sample of 101 participants with upper limb amputation who use a prosthetic device and were undergoing a prosthesis fitting process. Interventions Not applicable. Main Outcome Measures: PROs on pain with/without a prosthesis, satisfaction, and perceived function derived from the Comprehensive Arm Prosthesis and Rehabilitation Outcomes Questionnaire. Results Model coefficients indicate that with a unit increase in satisfaction (p < 0.001) and pain (p = 0.031) scores (with higher pain scores signifying less pain), the mean of perceived function increases by 0.66 and 0.47 units, respectively. Conversely, for individuals with elbow disarticulation, transhumeral, shoulder disarticulation, and interscapulothoracic amputations, the mean of perceived function decreases by 22.02 units (p = 0.006). Conclusions Based on our sample, perceived function is significantly associated with satisfaction, pain, and amputation level. These findings could potentially help to inform initial clinical approach and targeted outcomes for patients based on these factors.
- Open Access
- 24 July 2021
- Published by Elsevier in Archives of Rehabilitation Research and Clinical Translation
- Vol. 3 (3) , 100148
Understanding the Relationship Between Patient-Reported Function and Actual Function in the Upper Limb Prosthesis User Population: A Preliminary Study
- 24 July 2021
- Published by Elsevier in Archives of Rehabilitation Research and Clinical Translation
- Vol. 3 (3) , 100148
Open AccessUnderstanding the Relationship Between Patient-Reported Function and Actual Function in the Upper Limb Prosthesis User Population: A Preliminary Study