Raffaella Righetti
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Research Interests
Raffaella Righetti has a total of 79 co-authors. Here are the top co-authors by number of shared publications:
- Tauhidul Islam
Department of Radiation Oncology, Stanford University, Stanford, USA
17 shared publications Anuj Chaudhry
Department of Electrical and Computer Engineering, Texas A&M University, College Station, TX 77843 USA
11 shared publications- Ennio Tasciotti
Department of Human Sciences and Promotion of the Quality of Life, San Raffaele Roma University, 00166 Rome, Italy
10 shared publications Songyuan Tang
Department of Electrical and Computer Engineering, Texas A&M University, College Station, USA
7 shared publicationsEnnio Tasciotti
Department of Human Sciences and Promotion of Quality of Life, San Raffaele Roma University, Italy
6 shared publicationsFrancesca Taraballi
Center for Musculoskeletal Regeneration, Houston Methodist Research Institute, Houston, USA
6 shared publications
Latest Publications
- Open Access
- 12 September 2026
- Published by Springer Nature in Scientific Reports
First demonstration of in vivo estimation of Young’s modulus in cancers using poroelastography with experimental validation
- 12 September 2026
- Published by Springer Nature in Scientific Reports
Open AccessFirst demonstration of in vivo estimation of Young’s modulus in cancers using poroelastography with experimental validation
- Open Access
- 19 February 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Artificial Intelligence
- Vol. PP (8) , 1-15
ECGNextFormer: A Lightweight, Scalable, and Explainable Architecture for Estimating Cardiovascular Well-being from Electrocardiograms.
An electrocardiogram (ECG) is a widely utilized non-invasive test in healthcare for diagnosing cardiac diseases. Recent studies have validated that the delta between neural network-derived ECG age and chronological age represents a measure of cardiovascular well-being. Typically, ECG age estimation studies rely on neural networks designed for ECG disease diagnosis, resulting in networks that are often computationally heavy, difficult to scale, and challenging to interpret. To address this gap, we propose ECGNextFormer, a lightweight hybrid CNN and transformer architecture for efficient ECG age estimation. ECGNextFormer features a novel shallow backbone with modified ECGNext blocks for ECG feature extraction and integrates a custom self-attention layer with a multiscale pooling block to enhance the receptive field. The bottleneck drop key self-attention provides a global receptive field and reweighs the feature maps, while multiscale pooling retains fine-grained spatial details crucial for age estimation. These innovations make ECGNextFormer a lightweight and scalable alternative to existing networks with superior performance. The lite variant of ECGNextFormer surpasses the best network in the literature by 14.7% in performance and 53× lower parameter count. ECGNextFormer is comprehensively explained through fine-grained heatmaps generated using guided backpropagation. Subsequently, a novel lead scoring scheme quantifies lead significance in healthy and diseased groups, and human-interpretable concepts highlight essential ECG features for age estimation.
- 19 February 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Artificial Intelligence
- Vol. PP (8) , 1-15
Open AccessECGNextFormer: A Lightweight, Scalable, and Explainable Architecture for Estimating Cardiovascular Well-being from Electrocardiograms.
An electrocardiogram (ECG) is a widely utilized non-invasive test in healthcare for diagnosing cardiac diseases. Recent studies have validated that the delta between neural network-derived ECG age and chronological age represents a measure of cardiovascular well-being. Typically, ECG age estimation studies rely on neural networks designed for ECG disease diagnosis, resulting in networks that are often computationally heavy, difficult to scale, and challenging to interpret. To address this gap, we propose ECGNextFormer, a lightweight hybrid CNN and transformer architecture for efficient ECG age estimation. ECGNextFormer features a novel shallow backbone with modified ECGNext blocks for ECG feature extraction and integrates a custom self-attention layer with a multiscale pooling block to enhance the receptive field. The bottleneck drop key self-attention provides a global receptive field and reweighs the feature maps, while multiscale pooling retains fine-grained spatial details crucial for age estimation. These innovations make ECGNextFormer a lightweight and scalable alternative to existing networks with superior performance. The lite variant of ECGNextFormer surpasses the best network in the literature by 14.7% in performance and 53× lower parameter count. ECGNextFormer is comprehensively explained through fine-grained heatmaps generated using guided backpropagation. Subsequently, a novel lead scoring scheme quantifies lead significance in healthy and diseased groups, and human-interpretable concepts highlight essential ECG features for age estimation.
- Open Access
- 31 October 2025
- Published by Oxford University Press (OUP) in PNAS Nexus
- Vol. 4 (11) , pgaf354
Vascular hydraulic conductivity imaging in cancers in vivo based on spatiotemporal ultrasound elastography
Vascular hydraulic conductivity (Lp) plays important roles in cancer metastasis, progression, and treatments. To date, there are a few noninvasive methods to image Lp in cancers, and these methods rely on several assumptions. Common assumptions include that vascular conductivity is dominant over interstitial conductivity inside the tumor and that interstitial effects in the background are dominant over interstitial effects inside the tumor, limiting their applicability to cancers with a narrow range of Lp. In this article, we propose a new method to image a wide range of Lp in cancers using ultrasound spatiotemporal elastography data, without the limitations of existing methods. The method is based on the knowledge of Young's modulus, Poisson's ratio, and volumetric strain. This method shows superior performance with respect to the previous methods in terms of percent-relative-error in simulation studies. In vivo experimental results in an orthotopic mouse model of breast cancer show that Lp estimated by ultrasound imaging using the proposed method is highly correlated with histological CD31 data. The proposed imaging methods can thus provide clinically significant information noninvasively and cost-effectively.
- 31 October 2025
- Published by Oxford University Press (OUP) in PNAS Nexus
- Vol. 4 (11) , pgaf354
Open AccessVascular hydraulic conductivity imaging in cancers in vivo based on spatiotemporal ultrasound elastography
Vascular hydraulic conductivity (Lp) plays important roles in cancer metastasis, progression, and treatments. To date, there are a few noninvasive methods to image Lp in cancers, and these methods rely on several assumptions. Common assumptions include that vascular conductivity is dominant over interstitial conductivity inside the tumor and that interstitial effects in the background are dominant over interstitial effects inside the tumor, limiting their applicability to cancers with a narrow range of Lp. In this article, we propose a new method to image a wide range of Lp in cancers using ultrasound spatiotemporal elastography data, without the limitations of existing methods. The method is based on the knowledge of Young's modulus, Poisson's ratio, and volumetric strain. This method shows superior performance with respect to the previous methods in terms of percent-relative-error in simulation studies. In vivo experimental results in an orthotopic mouse model of breast cancer show that Lp estimated by ultrasound imaging using the proposed method is highly correlated with histological CD31 data. The proposed imaging methods can thus provide clinically significant information noninvasively and cost-effectively.
- 21 May 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Biomedical Engineering
- Vol. 72 (12) , 3546-3557
Non-Invasive Assessment of Structural and Mechanical Micro-Environmental Changes During Long Bone Regeneration Using a Multi-Modal and Multi-Parametric Ultrasound Imaging Technique in a Segmental Tibial Defect Sheep Model In Vivo
Objective: The underlying regeneration process of bony defects often exhibits multifaceted nature, which may not be completely characterized by imaging methods currently available to the clinic. In this paper, we present the first longitudinal study to use multi-modal and multi-parametric ultrasound (US) imaging to assess bone regeneration in situations of segmental defects. Methods: We derived two imaging markers from the proposed US imaging technique: the new-bone bulk volume and fibrovascular connective tissue area and computed their global and local statistics in a subject-specific manner. Results: From a cohort of 5 sheep treated with baseline tissue engineered construct, the distance (mm) between surface reconstructions from multi-view 3-D US and CT was $0.30\pm 0.67$ (60 days post implantation) and $0.22\pm 0.43$ (120 days post implantation). From US elastography (USE), we discovered a new contrast mechanism between the soft tissue and fibrovascular connective tissue in axial normal strain elastograms and corroborated it using endpoint histology. From two sheep, we detected negative and positive correlations between the fibrovascular connective tissue area at 60 days post shell implantation and the area of bone mass that continued to form after 60 days post shell implantation. Conclusion: Based on our results, it is feasible to use the proposed multi-modal and multi-parametric US imaging technique to assess structural and mechanical micro-environmental changes in the sheep animal model. Significance: In the future, 3-D US and USE may become important quantitative tools for bone fracture healing diagnosis and prognosis.
- 21 May 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Biomedical Engineering
- Vol. 72 (12) , 3546-3557
Non-Invasive Assessment of Structural and Mechanical Micro-Environmental Changes During Long Bone Regeneration Using a Multi-Modal and Multi-Parametric Ultrasound Imaging Technique in a Segmental Tibial Defect Sheep Model In Vivo
Objective: The underlying regeneration process of bony defects often exhibits multifaceted nature, which may not be completely characterized by imaging methods currently available to the clinic. In this paper, we present the first longitudinal study to use multi-modal and multi-parametric ultrasound (US) imaging to assess bone regeneration in situations of segmental defects. Methods: We derived two imaging markers from the proposed US imaging technique: the new-bone bulk volume and fibrovascular connective tissue area and computed their global and local statistics in a subject-specific manner. Results: From a cohort of 5 sheep treated with baseline tissue engineered construct, the distance (mm) between surface reconstructions from multi-view 3-D US and CT was $0.30\pm 0.67$ (60 days post implantation) and $0.22\pm 0.43$ (120 days post implantation). From US elastography (USE), we discovered a new contrast mechanism between the soft tissue and fibrovascular connective tissue in axial normal strain elastograms and corroborated it using endpoint histology. From two sheep, we detected negative and positive correlations between the fibrovascular connective tissue area at 60 days post shell implantation and the area of bone mass that continued to form after 60 days post shell implantation. Conclusion: Based on our results, it is feasible to use the proposed multi-modal and multi-parametric US imaging technique to assess structural and mechanical micro-environmental changes in the sheep animal model. Significance: In the future, 3-D US and USE may become important quantitative tools for bone fracture healing diagnosis and prognosis.
- 31 January 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Journal of Biomedical and Health Informatics
- Vol. 29 (7) , 5109-5122
RAFT-USENet: A Unified Network for Accurate Axial and Lateral Motion Estimation in Ultrasound Elastography Imaging
High-quality motion estimation is essential in ultrasound elastography (USE) for evaluating tissue mechanical properties and detecting abnormalities. Traditional methods, such as speckle tracking and regularized optimization, face challenges including noise, over-smoothing of displacements, and prolonged runtimes. Recent efforts have explored optical flow-based convolutional neural networks (CNNs). However, current approaches experience at least one of the following limitations: 1) reliance on tissue incompressibility assumption, which compromises data fidelity and can introduce large errors; 2) dependence on ground truth displacement data for supervised CNN methods; 3) use of a regularizer not aligned with tissue physics by relying only on first-order displacement derivatives; 4) use of a L2-norm regularizer that over-smoothes motion estimates; and 5) substantially large sampling size, increasing computational and memory demands, especially for classical methods. In this paper, we develop RAFT-USENet, a physics-informed, unsupervised neural network to estimate both axial and lateral displacements. We design RAFT-USENet by substantially modifying optical flow RAFT network to adapt it to high-frequency USE data. Extensive validation using simulation, phantom and in vivo data demonstrates that RAFT-USENet significantly improves motion estimation performance compared to recent classical and CNN methods. The normalized cross-correlation between pre- and warped post-deformation USE data using RAFT-USENet is estimated as 0.94, 0.88, and 0.82 in simulation, breast phantom and in vivo datasets, respectively, while corresponding comparative methods ranges were found 0.79-0.88, 0.76-0.85, and 0.69-0.81. Additionally, RAFT-USENet reduced computational time by 1.5-150 times compared to existing methods. These results suggest that RAFT-USENet may be a potentially useful reliable and accurate tool for clinical elasticity imaging applications.
- 31 January 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Journal of Biomedical and Health Informatics
- Vol. 29 (7) , 5109-5122
RAFT-USENet: A Unified Network for Accurate Axial and Lateral Motion Estimation in Ultrasound Elastography Imaging
High-quality motion estimation is essential in ultrasound elastography (USE) for evaluating tissue mechanical properties and detecting abnormalities. Traditional methods, such as speckle tracking and regularized optimization, face challenges including noise, over-smoothing of displacements, and prolonged runtimes. Recent efforts have explored optical flow-based convolutional neural networks (CNNs). However, current approaches experience at least one of the following limitations: 1) reliance on tissue incompressibility assumption, which compromises data fidelity and can introduce large errors; 2) dependence on ground truth displacement data for supervised CNN methods; 3) use of a regularizer not aligned with tissue physics by relying only on first-order displacement derivatives; 4) use of a L2-norm regularizer that over-smoothes motion estimates; and 5) substantially large sampling size, increasing computational and memory demands, especially for classical methods. In this paper, we develop RAFT-USENet, a physics-informed, unsupervised neural network to estimate both axial and lateral displacements. We design RAFT-USENet by substantially modifying optical flow RAFT network to adapt it to high-frequency USE data. Extensive validation using simulation, phantom and in vivo data demonstrates that RAFT-USENet significantly improves motion estimation performance compared to recent classical and CNN methods. The normalized cross-correlation between pre- and warped post-deformation USE data using RAFT-USENet is estimated as 0.94, 0.88, and 0.82 in simulation, breast phantom and in vivo datasets, respectively, while corresponding comparative methods ranges were found 0.79-0.88, 0.76-0.85, and 0.69-0.81. Additionally, RAFT-USENet reduced computational time by 1.5-150 times compared to existing methods. These results suggest that RAFT-USENet may be a potentially useful reliable and accurate tool for clinical elasticity imaging applications.
- 5 August 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Medical Imaging
- Vol. 44 (1) , 232-243
A Novel Poroelastography Method for High-Quality Estimation of Lateral Strain, Solid Stress, and Fluid Pressure In Vivo
Assessment of mechanical and transport properties of tissues using ultrasound elasticity imaging requires accurate estimations of the spatiotemporal distribution of volumetric strain. Due to physical constraints such as pitch limitation and the lack of phase information in the lateral direction, the quality of lateral strain estimation is typically significantly lower than the quality of axial strain estimation. In this paper, a novel lateral strain estimation technique based on the physics of compressible porous media is developed, tested and validated. This technique is referred to as “Poroelastography-based Ultrasound Lateral Strain Estimation” (PULSE). PULSE differs from previously proposed lateral strain estimators as it uses the underlying physics of internal fluid flow within a local region of the tissue as theoretical foundation. PULSE establishes a relation between spatiotemporal changes in the axial strains and corresponding spatiotemporal changes in the lateral strains, effectively allowing assessment of lateral strains with comparable quality of axial strain estimators. We demonstrate that PULSE can also be used to accurately track compression-induced solid stresses and fluid pressure in cancers using ultrasound poroelastography (USPE). In this study, we report the theoretical formulation for PULSE and validation using finite element (FE) and ultrasound simulations. PULSE-generated results exhibit less than 5% percentage relative error (PRE) and greater than 90% structural similarity index (SSIM) compared to ground truth simulations. Experimental results are included to qualitatively assess the performance of PULSE in vivo . The proposed method can be used to overcome the inherent limitations of non-axial strain imaging and improve clinical translatability of USPE.
- 5 August 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Medical Imaging
- Vol. 44 (1) , 232-243
A Novel Poroelastography Method for High-Quality Estimation of Lateral Strain, Solid Stress, and Fluid Pressure In Vivo
Assessment of mechanical and transport properties of tissues using ultrasound elasticity imaging requires accurate estimations of the spatiotemporal distribution of volumetric strain. Due to physical constraints such as pitch limitation and the lack of phase information in the lateral direction, the quality of lateral strain estimation is typically significantly lower than the quality of axial strain estimation. In this paper, a novel lateral strain estimation technique based on the physics of compressible porous media is developed, tested and validated. This technique is referred to as “Poroelastography-based Ultrasound Lateral Strain Estimation” (PULSE). PULSE differs from previously proposed lateral strain estimators as it uses the underlying physics of internal fluid flow within a local region of the tissue as theoretical foundation. PULSE establishes a relation between spatiotemporal changes in the axial strains and corresponding spatiotemporal changes in the lateral strains, effectively allowing assessment of lateral strains with comparable quality of axial strain estimators. We demonstrate that PULSE can also be used to accurately track compression-induced solid stresses and fluid pressure in cancers using ultrasound poroelastography (USPE). In this study, we report the theoretical formulation for PULSE and validation using finite element (FE) and ultrasound simulations. PULSE-generated results exhibit less than 5% percentage relative error (PRE) and greater than 90% structural similarity index (SSIM) compared to ground truth simulations. Experimental results are included to qualitatively assess the performance of PULSE in vivo . The proposed method can be used to overcome the inherent limitations of non-axial strain imaging and improve clinical translatability of USPE.
- 9 April 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Medical Imaging
- Vol. 43 (8) , 3027-3043
Non-Invasive Imaging of Mechanical Properties of Cancers In Vivo Based on Transformations of the Eshelby’s Tensor Using Compression Elastography
Knowledge of the mechanical properties is of great clinical significance for diagnosis, prognosis and treatment of cancers. Recently, a new method based on Eshelby’s theory to simultaneously assess Young’s modulus (YM) and Poisson’s ratio (PR) in tissues has been proposed. A significant limitation of this method is that accuracy of the reconstructed YM and PR is affected by the orientation/alignment of the tumor with the applied stress. In this paper, we propose a new method to reconstruct YM and PR in cancers that is invariant to the 3D orientation of the tumor with respect to the axis of applied stress. The novelty of the proposed method resides on the use of a tensor transformation to improve the robustness of Eshelby’s theory and reconstruct YM and PR of tumors with high accuracy and in realistic experimental conditions. The method is validated using finite element simulations and controlled experiments using phantoms with known mechanical properties. The in vivo feasibility of the developed method is demonstrated in an orthotopic mouse model of breast cancer. Our results show that the proposed technique can estimate the YM and PR with overall accuracy of (97.06 ± 2.42) % under all tested tumor orientations. Animal experimental data demonstrate the potential of the proposed methodology in vivo . The proposed method can significantly expand the range of applicability of the Eshelby’s theory to tumors and provide new means to accurately image and quantify mechanical parameters of cancers in clinical conditions.
- 9 April 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Medical Imaging
- Vol. 43 (8) , 3027-3043
Non-Invasive Imaging of Mechanical Properties of Cancers In Vivo Based on Transformations of the Eshelby’s Tensor Using Compression Elastography
Knowledge of the mechanical properties is of great clinical significance for diagnosis, prognosis and treatment of cancers. Recently, a new method based on Eshelby’s theory to simultaneously assess Young’s modulus (YM) and Poisson’s ratio (PR) in tissues has been proposed. A significant limitation of this method is that accuracy of the reconstructed YM and PR is affected by the orientation/alignment of the tumor with the applied stress. In this paper, we propose a new method to reconstruct YM and PR in cancers that is invariant to the 3D orientation of the tumor with respect to the axis of applied stress. The novelty of the proposed method resides on the use of a tensor transformation to improve the robustness of Eshelby’s theory and reconstruct YM and PR of tumors with high accuracy and in realistic experimental conditions. The method is validated using finite element simulations and controlled experiments using phantoms with known mechanical properties. The in vivo feasibility of the developed method is demonstrated in an orthotopic mouse model of breast cancer. Our results show that the proposed technique can estimate the YM and PR with overall accuracy of (97.06 ± 2.42) % under all tested tumor orientations. Animal experimental data demonstrate the potential of the proposed methodology in vivo . The proposed method can significantly expand the range of applicability of the Eshelby’s theory to tumors and provide new means to accurately image and quantify mechanical parameters of cancers in clinical conditions.
- Open Access
- 15 September 2023
- Published by Springer Nature in Scientific Reports
- Vol. 13 (1) , 1-11
Assessment of spinal cord injury using ultrasound elastography in a rabbit model in vivo
The effect of the mechanical micro-environment on spinal cord injury (SCI) and treatment effectiveness remains unclear. Currently, there are limited imaging methods that can directly assess the localized mechanical behavior of spinal cords in vivo. In this study, we apply new ultrasound elastography (USE) techniques to assess SCI in vivo at the site of the injury and at the time of one week post injury, in a rabbit animal model. Eleven rabbits underwent laminectomy procedures. Among them, spinal cords of five rabbits were injured during the procedure. The other six rabbits were used as control. Two neurological statuses were achieved: non-paralysis and paralysis. Ultrasound data were collected one week post-surgery and processed to compute strain ratios. Histologic analysis, mechanical testing, magnetic resonance imaging (MRI), computerized tomography and MRI diffusion tensor imaging (DTI) were performed to validate USE results. Strain ratios computed via USE were found to be significantly different in paralyzed versus non-paralyzed rabbits. The myelomalacia histologic score and spinal cord Young’s modulus evaluated in selected animals were in good qualitative agreement with USE assessment. It is feasible to use USE to assess changes in the spinal cord of the presented animal model. In the future, with more experimental data available, USE may provide new quantitative tools for improving SCI diagnosis and prognosis.
- 15 September 2023
- Published by Springer Nature in Scientific Reports
- Vol. 13 (1) , 1-11
Open AccessAssessment of spinal cord injury using ultrasound elastography in a rabbit model in vivo
The effect of the mechanical micro-environment on spinal cord injury (SCI) and treatment effectiveness remains unclear. Currently, there are limited imaging methods that can directly assess the localized mechanical behavior of spinal cords in vivo. In this study, we apply new ultrasound elastography (USE) techniques to assess SCI in vivo at the site of the injury and at the time of one week post injury, in a rabbit animal model. Eleven rabbits underwent laminectomy procedures. Among them, spinal cords of five rabbits were injured during the procedure. The other six rabbits were used as control. Two neurological statuses were achieved: non-paralysis and paralysis. Ultrasound data were collected one week post-surgery and processed to compute strain ratios. Histologic analysis, mechanical testing, magnetic resonance imaging (MRI), computerized tomography and MRI diffusion tensor imaging (DTI) were performed to validate USE results. Strain ratios computed via USE were found to be significantly different in paralyzed versus non-paralyzed rabbits. The myelomalacia histologic score and spinal cord Young’s modulus evaluated in selected animals were in good qualitative agreement with USE assessment. It is feasible to use USE to assess changes in the spinal cord of the presented animal model. In the future, with more experimental data available, USE may provide new quantitative tools for improving SCI diagnosis and prognosis.
- 30 June 2023
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 68 (13) , 135014
Assessment of compression-induced solid stress, fluid pressure and mechanopathological parameters in cancers in vivo using poroelastography
Objective. Compression-induced solid stress (SSc) and fluid pressure (FPc) during ultrasound poroelastography (USPE) experiments are correlated with two markers of cancer growth and treatment effectiveness: growth-induced solid stress (SSg) and interstitial fluid pressure (IFP). The spatio-temporal distributions of SSg and IFP are determined by the transport properties of the vessels and interstitium in the tumor microenvironment. Approach. We propose a new USPE method for the non-invasive imaging of the local cancer mechanical parameters and dynamics of fluid flow. When performing poroelastography experiments, it may be difficult to implement a typical creep compression protocol, which requires to maintain a constant normally applied force. In this paper, we investigate the use of a stress relaxation protocol, which might be a more convenient choice for clinical poroelastography applications. Main results. Based on our finite element and ultrasound simulations study, we demonstrate that the SSc, FPc and their spatio-temporal distribution related parameters, interstitial permeability and vascular permeability, can be determined from stress relaxation experiments with errors below 10% as compared to the ground truth and accuracy similar to that of corresponding creep tests, respectively. We also demonstrate the feasibility of the new methodology for in vivo experiments using a small animal cancer model. Significance. The proposed non-invasive USPE imaging methods may become an effective tool to assess local tumor pressure and mechanopathological parameters in cancers.
- 30 June 2023
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 68 (13) , 135014
Assessment of compression-induced solid stress, fluid pressure and mechanopathological parameters in cancers in vivo using poroelastography
Objective. Compression-induced solid stress (SSc) and fluid pressure (FPc) during ultrasound poroelastography (USPE) experiments are correlated with two markers of cancer growth and treatment effectiveness: growth-induced solid stress (SSg) and interstitial fluid pressure (IFP). The spatio-temporal distributions of SSg and IFP are determined by the transport properties of the vessels and interstitium in the tumor microenvironment. Approach. We propose a new USPE method for the non-invasive imaging of the local cancer mechanical parameters and dynamics of fluid flow. When performing poroelastography experiments, it may be difficult to implement a typical creep compression protocol, which requires to maintain a constant normally applied force. In this paper, we investigate the use of a stress relaxation protocol, which might be a more convenient choice for clinical poroelastography applications. Main results. Based on our finite element and ultrasound simulations study, we demonstrate that the SSc, FPc and their spatio-temporal distribution related parameters, interstitial permeability and vascular permeability, can be determined from stress relaxation experiments with errors below 10% as compared to the ground truth and accuracy similar to that of corresponding creep tests, respectively. We also demonstrate the feasibility of the new methodology for in vivo experiments using a small animal cancer model. Significance. The proposed non-invasive USPE imaging methods may become an effective tool to assess local tumor pressure and mechanopathological parameters in cancers.
- Open Access
- 2 May 2023
- Published by Springer Nature in Scientific Reports
- Vol. 13 (1) , 1-15
Non-invasive imaging of interstitial fluid transport parameters in solid tumors in vivo
In this paper, new and non-invasive imaging methods to assess interstitial fluid transport parameters in tumors in vivo are developed, analyzed and experimentally validated. These parameters include extracellular volume fraction (EVF), interstitial fluid volume fraction (IFVF) and interstitial hydraulic conductivity (IHC), and they are known to have a critical role in cancer progression and drug delivery effectiveness. EVF is defined as the volume of extracellular matrix per unit volume of the tumor, while IFVF refers to the volume of interstitial fluid per unit bulk volume of the tumor. There are currently no established imaging methods to assess interstitial fluid transport parameters in cancers in vivo. We develop and test new theoretical models and imaging techniques to assess fluid transport parameters in cancers using non-invasive ultrasound methods. EVF is estimated via the composite/mixture theory with the tumor being modeled as a biphasic (cellular phase and extracellular phase) composite material. IFVF is estimated by modeling the tumor as a biphasic poroelastic material with fully saturated solid phase. Finally, IHC is estimated from IFVF using the well-known Kozeny–Carman method inspired by soil mechanics theory. The proposed methods are tested using both controlled experiments and in vivo experiments on cancers. The controlled experiments were performed on tissue mimic polyacrylamide samples and validated using scanning electron microscopy (SEM). In vivo applicability of the proposed methods was demonstrated using a breast cancer model implanted in mice. Based on the controlled experimental validation, the proposed methods can estimate interstitial fluid transport parameters with an error below 10% with respect to benchmark SEM data. In vivo results demonstrate that EVF, IFVF and IHC increase in untreated tumors whereas these parameters are observed to decrease over time in treated tumors. The proposed non-invasive imaging methods may provide new and cost-effective diagnostic and prognostic tools to assess clinically relevant fluid transport parameters in cancers in vivo.
- 2 May 2023
- Published by Springer Nature in Scientific Reports
- Vol. 13 (1) , 1-15
Open AccessNon-invasive imaging of interstitial fluid transport parameters in solid tumors in vivo
In this paper, new and non-invasive imaging methods to assess interstitial fluid transport parameters in tumors in vivo are developed, analyzed and experimentally validated. These parameters include extracellular volume fraction (EVF), interstitial fluid volume fraction (IFVF) and interstitial hydraulic conductivity (IHC), and they are known to have a critical role in cancer progression and drug delivery effectiveness. EVF is defined as the volume of extracellular matrix per unit volume of the tumor, while IFVF refers to the volume of interstitial fluid per unit bulk volume of the tumor. There are currently no established imaging methods to assess interstitial fluid transport parameters in cancers in vivo. We develop and test new theoretical models and imaging techniques to assess fluid transport parameters in cancers using non-invasive ultrasound methods. EVF is estimated via the composite/mixture theory with the tumor being modeled as a biphasic (cellular phase and extracellular phase) composite material. IFVF is estimated by modeling the tumor as a biphasic poroelastic material with fully saturated solid phase. Finally, IHC is estimated from IFVF using the well-known Kozeny–Carman method inspired by soil mechanics theory. The proposed methods are tested using both controlled experiments and in vivo experiments on cancers. The controlled experiments were performed on tissue mimic polyacrylamide samples and validated using scanning electron microscopy (SEM). In vivo applicability of the proposed methods was demonstrated using a breast cancer model implanted in mice. Based on the controlled experimental validation, the proposed methods can estimate interstitial fluid transport parameters with an error below 10% with respect to benchmark SEM data. In vivo results demonstrate that EVF, IFVF and IHC increase in untreated tumors whereas these parameters are observed to decrease over time in treated tumors. The proposed non-invasive imaging methods may provide new and cost-effective diagnostic and prognostic tools to assess clinically relevant fluid transport parameters in cancers in vivo.