Michael Strömgren
Research Subjects
Research Interests
Michael Strömgren has a total of 7 co-authors. Here are the top co-authors by number of shared publications:
Anders Johansson
The National Board of Housing, Building and Planning (Boverket) Karlskrona, Sweden
1 shared publicationErik Almgren
Bengt Dahlgren, Fire & Risk Malmö, Sweden
1 shared publicationJoakim Albrektsson
SP Technical Research Institute of Sweden, Borås, Sweden
1 shared publication- Margaret McNamee
Division of Fire Safety Engineering, Lund University, Lund, Sweden
1 shared publication - Nils Johansson
Division of Fire Safety Engineering, Lund University, Lund, Sweden
1 shared publication - Patrick van Hees
Division of Fire Safety Engineering Lund University Lund Sweden
1 shared publication
Latest Publications
- Open Access
- 29 November 2013
- Published by EDP Sciences in MATEC Web of Conferences
- Vol. 9, 03006
Façade fires in Swedish school buildings
Fires outside school buildings caused by arson are a major problem in Sweden. The initial fire source can involve rubbish or other types of combustibles that can be found at or sometimes brought to the school. As the external fire develops the flames will extend along the façade. If the building is a one-story building, which is a common construction in Swedish school buildings, the fire can spread to the attic and further on to the rest of the building. A large research project was initiated in 2008 by the Swedish Fire Research Board in order to reduce the number and consequences of arson fires in school buildings. In this paper an evaluation of some technical systems that can be used to mitigate consequences of exterior fires is presented. The evaluation includes a literature review, experimental studies and a cost-benefit analysis. The study showed that some systems have clear cost-benefit advantages for the protection of school buildings in places where a high fire frequency can be expected.
- 29 November 2013
- Published by EDP Sciences in MATEC Web of Conferences
- Vol. 9, 03006
Open AccessFaçade fires in Swedish school buildings
Fires outside school buildings caused by arson are a major problem in Sweden. The initial fire source can involve rubbish or other types of combustibles that can be found at or sometimes brought to the school. As the external fire develops the flames will extend along the façade. If the building is a one-story building, which is a common construction in Swedish school buildings, the fire can spread to the attic and further on to the rest of the building. A large research project was initiated in 2008 by the Swedish Fire Research Board in order to reduce the number and consequences of arson fires in school buildings. In this paper an evaluation of some technical systems that can be used to mitigate consequences of exterior fires is presented. The evaluation includes a literature review, experimental studies and a cost-benefit analysis. The study showed that some systems have clear cost-benefit advantages for the protection of school buildings in places where a high fire frequency can be expected.
- Open Access
- 29 November 2013
- Published by EDP Sciences in MATEC Web of Conferences
- Vol. 9, 01003
Comparative analysis of façade regulations in the Nordic countries
This paper presents a comparison of Nordic fire safety requirements of facades. A reference building was chosen as a four-story residential building. The requirements were analysed with focus on what fire safety objectives they represent, and what type of pre-accepted solutions that were used. The results reveal large differences in the Nordic building regulations concerning façades. The differences occur both with regards to performance objectives, criteria and acceptable solutions. Current European methods are not sufficient to characterise the requirements needed for fire safety of facades. There is a need to develop new common verification methods, as well as better data and research, to improve requirements and to reach conformity.
- 29 November 2013
- Published by EDP Sciences in MATEC Web of Conferences
- Vol. 9, 01003
Open AccessComparative analysis of façade regulations in the Nordic countries
This paper presents a comparison of Nordic fire safety requirements of facades. A reference building was chosen as a four-story residential building. The requirements were analysed with focus on what fire safety objectives they represent, and what type of pre-accepted solutions that were used. The results reveal large differences in the Nordic building regulations concerning façades. The differences occur both with regards to performance objectives, criteria and acceptable solutions. Current European methods are not sufficient to characterise the requirements needed for fire safety of facades. There is a need to develop new common verification methods, as well as better data and research, to improve requirements and to reach conformity.