Elena Borgardt
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Elena Borgardt has a total of 23 co-authors. Here are the top co-authors by number of shared publications:
- Detlef Stolten
Forschungszentrum Jülich
3 shared publications Martin Müller
3 shared publicationsWerner Lehnert
3 shared publicationsDetlef Stolten
2 shared publications- Franz Josef Hackemüller
Institute of Energy and Climate Research (IEK-1), Forschungszentrum Jülich GmbH, Jülich, Germany
2 shared publications - Ingo Manke
Helmholtz-Zentrum Berlin für Materialien und Energie, Hahn-Meitner-Platz 1, Berlin 14109, Germany
2 shared publications
Latest Publications
- 1 September 2019
- Published by Elsevier in International Journal of Hydrogen Energy
- Vol. 44 (42) , 23556-23567
Impact of clamping pressure and stress relaxation on the performance of different polymer electrolyte membrane water electrolysis cell designs
- 1 September 2019
- Published by Elsevier in International Journal of Hydrogen Energy
- Vol. 44 (42) , 23556-23567
Impact of clamping pressure and stress relaxation on the performance of different polymer electrolyte membrane water electrolysis cell designs
- Open Access
Influence of Stoichiometry on the Two-Phase Flow Behavior of Proton Exchange Membrane Electrolyzers
In order for electrolysis cells to operate optimally, mass transport must be improved. The key initial component for optimal operation is the current collector, which is also essential for mass transport. Water as an educt of the reaction must be evenly distributed by the current collector to the membrane electrode assembly. As products of the reaction, hydrogen and oxygen must also be directed quickly and efficiently through the current collector into the channel and removed from the cell. The second key component is the stoichiometry, which includes the current density and water volume flow rate and represents the ratio between the water supplied and water consumed. This study presents the correlation of the stoichiometry, two-phase flow in the channel and gas fraction in the porous transport layer for the first time. The gas-water ratio in the channel and porous transport layer during cell operation with various stoichiometries was investigated by means of a model in the form of an ex situ cell without electrochemical processes. Bubble formation in the channel was observed using a transparent cell. The gas-water exchange in the porous transport layer was then investigated using neutron radiography.
Open AccessInfluence of Stoichiometry on the Two-Phase Flow Behavior of Proton Exchange Membrane Electrolyzers
In order for electrolysis cells to operate optimally, mass transport must be improved. The key initial component for optimal operation is the current collector, which is also essential for mass transport. Water as an educt of the reaction must be evenly distributed by the current collector to the membrane electrode assembly. As products of the reaction, hydrogen and oxygen must also be directed quickly and efficiently through the current collector into the channel and removed from the cell. The second key component is the stoichiometry, which includes the current density and water volume flow rate and represents the ratio between the water supplied and water consumed. This study presents the correlation of the stoichiometry, two-phase flow in the channel and gas fraction in the porous transport layer for the first time. The gas-water ratio in the channel and porous transport layer during cell operation with various stoichiometries was investigated by means of a model in the form of an ex situ cell without electrochemical processes. Bubble formation in the channel was observed using a transparent cell. The gas-water exchange in the porous transport layer was then investigated using neutron radiography.
- 23 July 2018
- Published by The Electrochemical Society in ECS Meeting Abstracts
- Vol. MA2018-02 (46) , 1597
Impact of Mechanical Operation Conditions on PEM Water Electrolyzer Performance
Hydrogen can be generated by means of PEM water electrolysis that makes use of renewably-produced electricity. To improve and maintain good performance of PEM electrolysis cells and stacks, research has been carried out mostly in the field of operation conditions, catalyst loading reduction and substitution of precious metals, two-phase flow investigation and analysing degradation effects. However, understanding mechanical interactions in the cell can additionally help to improve performance and lower investment costs [1]. In the electrolysis cell, the components are clamped against each other to ensure a good electrical contact. Excessive clamping pressure, however, leads to damage of the components. Studies on PEM fuel cells found that high clamping pressures reduces GDL porosity and leads to mass transport limitation [2]. In this work the influence of clamping pressure on the performance of different PEM electrolysis cell designs has been studied. Therefore, a test cell was designed that allows applying pressure directly on the active cell area. Polarisation curves and ohmic resistances were measured at different clamping pressures. Electrochemical impedance spectroscopy (EIS) was used to show the effect of compression on ohmic losses and mass transfer limitations. Furthermore, the pressure change within the cell over time was investigated. For all cell designs, optimal clamping pressure was found to be approximately 2.3 – 3 MPa. The impedance data show no higher mass transfer losses for higher pressures on the active area. However, the ohmic losses rise above a critical pressure. The results indicate that for PEM electrolysis, not mass transport limitations but protonic ohmic losses are crucial for a worse performance at high clamping pressures. Also it was found that stress relaxation of the membrane lead to pressure loss and thus to a worse performance over time. Borgardt, E., et al., Mechanical characterization and durability of sintered porous transport layers for polymer electrolyte membrane electrolysis. Journal of Power Sources, 2018. 374: p. 84-91. Mason, T.J., et al., A study of the effect of compression on the performance of polymer electrolyte fuel cells using electrochemical impedance spectroscopy and dimensional change analysis. International Journal of Hydrogen Energy, 2013. 38(18): p. 7414-7422.
- 23 July 2018
- Published by The Electrochemical Society in ECS Meeting Abstracts
- Vol. MA2018-02 (46) , 1597
Impact of Mechanical Operation Conditions on PEM Water Electrolyzer Performance
Hydrogen can be generated by means of PEM water electrolysis that makes use of renewably-produced electricity. To improve and maintain good performance of PEM electrolysis cells and stacks, research has been carried out mostly in the field of operation conditions, catalyst loading reduction and substitution of precious metals, two-phase flow investigation and analysing degradation effects. However, understanding mechanical interactions in the cell can additionally help to improve performance and lower investment costs [1]. In the electrolysis cell, the components are clamped against each other to ensure a good electrical contact. Excessive clamping pressure, however, leads to damage of the components. Studies on PEM fuel cells found that high clamping pressures reduces GDL porosity and leads to mass transport limitation [2]. In this work the influence of clamping pressure on the performance of different PEM electrolysis cell designs has been studied. Therefore, a test cell was designed that allows applying pressure directly on the active cell area. Polarisation curves and ohmic resistances were measured at different clamping pressures. Electrochemical impedance spectroscopy (EIS) was used to show the effect of compression on ohmic losses and mass transfer limitations. Furthermore, the pressure change within the cell over time was investigated. For all cell designs, optimal clamping pressure was found to be approximately 2.3 – 3 MPa. The impedance data show no higher mass transfer losses for higher pressures on the active area. However, the ohmic losses rise above a critical pressure. The results indicate that for PEM electrolysis, not mass transport limitations but protonic ohmic losses are crucial for a worse performance at high clamping pressures. Also it was found that stress relaxation of the membrane lead to pressure loss and thus to a worse performance over time. Borgardt, E., et al., Mechanical characterization and durability of sintered porous transport layers for polymer electrolyte membrane electrolysis. Journal of Power Sources, 2018. 374: p. 84-91. Mason, T.J., et al., A study of the effect of compression on the performance of polymer electrolyte fuel cells using electrochemical impedance spectroscopy and dimensional change analysis. International Journal of Hydrogen Energy, 2013. 38(18): p. 7414-7422.
- 1 June 2018
- Published by Elsevier in Journal of Power Sources
- Vol. 390, 108-115
In-situ two-phase flow investigation of different porous transport layer for a polymer electrolyte membrane (PEM) electrolyzer with neutron spectroscopy
- 1 June 2018
- Published by Elsevier in Journal of Power Sources
- Vol. 390, 108-115
In-situ two-phase flow investigation of different porous transport layer for a polymer electrolyte membrane (PEM) electrolyzer with neutron spectroscopy
- 1 January 2018
- Published by Elsevier in Journal of Power Sources
- Vol. 374, 84-91
Mechanical characterization and durability of sintered porous transport layers for polymer electrolyte membrane electrolysis
- 1 January 2018
- Published by Elsevier in Journal of Power Sources
- Vol. 374, 84-91
Mechanical characterization and durability of sintered porous transport layers for polymer electrolyte membrane electrolysis