Seong-Kyum Kim
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Seong-Kyum Kim has a total of 46 co-authors. Here are the top co-authors by number of shared publications:
- Il-Young Jang
Dept. of Civil Engineering, Kumoh National Institute of Technology, Gumi, Korea
4 shared publications Il Young Jang
3 shared publicationsIl-Young Jang
3 shared publications- Hee Jun Yang
Dept. of Civil Engineering, Kumoh National Institute of Technology, Gumi, Korea
2 shared publications Jong-Kwon Park
2 shared publicationsKorea University
2 shared publications
Latest Publications
- Open Access
Effect of OLED Waste Glass Powder on Early Strength Performance of Rapid-Hardening Concrete
Rapid-hardening concrete is widely used for rapid repairs but can suffer from accelerated hydration, shrinkage-related cracking, and durability concerns. This study evaluates the feasibility of replacing cement with OLED waste glass powder (0–30%) in CSA-type rapid-hardening concrete as a low-impact repair material. Mixtures were prepared at a constant binder content (400 kg/m3) and water-to-binder ratio (0.425), and fresh properties (slump, air content, setting time) and mechanical performance (compressive and bond strength) were tested from 4 h to 56 d. Mercury intrusion porosimetry (MIP) and TG/DTG were additionally used to interpret changes in pore structure and hydration-related thermal indices. Increasing glass powder replacement improved workability but delayed setting. A 10% replacement (O-GP10) maintained 4 h compressive strength and showed slightly higher long-term strength and consistently higher long-term bond strength than the control, whereas 20–30% replacement caused pronounced strength loss due to dilution. MIP results indicated that O-GP10 suppressed large pores (>0.1 μm) and promoted a refined pore structure dominated by finer pores. TG/DTG trends were interpreted using temperature windows as comparative indicators, suggesting age-dependent bound-water development and a reduced apparent contribution in the Al-bearing-hydrate-related region for O-GP10. Overall, roughly 10% OLED waste glass powder is suggested for CSA rapid-hardening concrete to ensure early functioning while enhancing long-term bonding and microstructural stability.
Open AccessEffect of OLED Waste Glass Powder on Early Strength Performance of Rapid-Hardening Concrete
Rapid-hardening concrete is widely used for rapid repairs but can suffer from accelerated hydration, shrinkage-related cracking, and durability concerns. This study evaluates the feasibility of replacing cement with OLED waste glass powder (0–30%) in CSA-type rapid-hardening concrete as a low-impact repair material. Mixtures were prepared at a constant binder content (400 kg/m3) and water-to-binder ratio (0.425), and fresh properties (slump, air content, setting time) and mechanical performance (compressive and bond strength) were tested from 4 h to 56 d. Mercury intrusion porosimetry (MIP) and TG/DTG were additionally used to interpret changes in pore structure and hydration-related thermal indices. Increasing glass powder replacement improved workability but delayed setting. A 10% replacement (O-GP10) maintained 4 h compressive strength and showed slightly higher long-term strength and consistently higher long-term bond strength than the control, whereas 20–30% replacement caused pronounced strength loss due to dilution. MIP results indicated that O-GP10 suppressed large pores (>0.1 μm) and promoted a refined pore structure dominated by finer pores. TG/DTG trends were interpreted using temperature windows as comparative indicators, suggesting age-dependent bound-water development and a reduced apparent contribution in the Al-bearing-hydrate-related region for O-GP10. Overall, roughly 10% OLED waste glass powder is suggested for CSA rapid-hardening concrete to ensure early functioning while enhancing long-term bonding and microstructural stability.
- Open Access
An Airborne and Impact Sound Insulation Analysis of 3D Woven Textiles on the Floor in Buildings
Noise has detrimental effects on mental and physical health and quality of life, especially for those living in apartment buildings. Therefore, sound insulation materials are pivotal for reducing unwanted noise as well as enhancing acoustic comfort. This study offers a hybrid approach for analyzing 3D woven textile sound insulation material effectiveness, especially in residential buildings, by simulating airborne sound insulation and testing manufactured slab samples with 3D woven textile mortars in a laboratory using a tapping machine. At the same time, the JCA model and the transfer matrix method are employed to calibrate sound absorption coefficients (SAC) and simulate its airborne sound insulation effect in buildings in Seoul, South Korea. Results indicate that the maximum mean sound pressure level (SPL) of the 3D woven textile was reduced up to 9 dB in the octave band frequencies. The thickness improvement of 3D woven textiles enhances the mid- and high-frequency sound absorption effect, most pronounced in 3D woven textiles made of double-layer (DSRM) material, which demonstrated an air sound insulation efficiency around 28.5% greater than that of traditional materials. The maximum drop in impact sound pressure level (SPL) at 2 kHz is 13 dB. The study also proposes a strategy to optimize sound insulation performance, which is used as an effective solution for noise control in buildings. These findings lay the groundwork for research on the application of 3D woven textiles for sound insulation in residential buildings and offer prospects for sustainable textile composites in architectural building applications.
Open AccessAn Airborne and Impact Sound Insulation Analysis of 3D Woven Textiles on the Floor in Buildings
Noise has detrimental effects on mental and physical health and quality of life, especially for those living in apartment buildings. Therefore, sound insulation materials are pivotal for reducing unwanted noise as well as enhancing acoustic comfort. This study offers a hybrid approach for analyzing 3D woven textile sound insulation material effectiveness, especially in residential buildings, by simulating airborne sound insulation and testing manufactured slab samples with 3D woven textile mortars in a laboratory using a tapping machine. At the same time, the JCA model and the transfer matrix method are employed to calibrate sound absorption coefficients (SAC) and simulate its airborne sound insulation effect in buildings in Seoul, South Korea. Results indicate that the maximum mean sound pressure level (SPL) of the 3D woven textile was reduced up to 9 dB in the octave band frequencies. The thickness improvement of 3D woven textiles enhances the mid- and high-frequency sound absorption effect, most pronounced in 3D woven textiles made of double-layer (DSRM) material, which demonstrated an air sound insulation efficiency around 28.5% greater than that of traditional materials. The maximum drop in impact sound pressure level (SPL) at 2 kHz is 13 dB. The study also proposes a strategy to optimize sound insulation performance, which is used as an effective solution for noise control in buildings. These findings lay the groundwork for research on the application of 3D woven textiles for sound insulation in residential buildings and offer prospects for sustainable textile composites in architectural building applications.
- Open Access
- 28 February 2025
- Published by Korean Society of Hazard Mitigation in Journal of the Korean Society of Hazard Mitigation
- Vol. 25 (1) , 119-124
A Study on the Structural Stability of Reinforced Concrete Slabs Using Topology Optimization
In this study, the stability of reinforced concrete structures has become a critical concern due to the increasing frequency of heavy rainfall and rising annual precipitation associated with global warming. Water infiltration into concrete can cause rebar corrosion, thereby compromising durability. To address this issue, water-blocking blocks were installed at the ends of road decks, and bending tests along with finite element analysis were conducted to evaluate the effectiveness of these measures in preventing rebar corrosion and enhancing structural stability.
- 28 February 2025
- Published by Korean Society of Hazard Mitigation in Journal of the Korean Society of Hazard Mitigation
- Vol. 25 (1) , 119-124
Open AccessA Study on the Structural Stability of Reinforced Concrete Slabs Using Topology Optimization
In this study, the stability of reinforced concrete structures has become a critical concern due to the increasing frequency of heavy rainfall and rising annual precipitation associated with global warming. Water infiltration into concrete can cause rebar corrosion, thereby compromising durability. To address this issue, water-blocking blocks were installed at the ends of road decks, and bending tests along with finite element analysis were conducted to evaluate the effectiveness of these measures in preventing rebar corrosion and enhancing structural stability.
- Open Access
- 28 October 2023
- Published by MDPI AG in Applied Sciences
- Vol. 13 (21) , 11798
Investigation of Load–Displacement Characteristics and Crack Behavior of RC Beam Based on Nonlinear Finite Element Analysis Using Concrete Damage Plasticity
Crack patterns provide critical information about the structural integrity and safety of concrete structures. However, until now, there has been a lack of sufficient studies on using the Finite Element (FE) method to investigate the characteristics of the crack patterns of reinforced concrete (RC) beams. Therefore, this study aims to develop an FE model to analyze the load–displacement and crack characteristics of a beam under a four-point bending test using the concrete damaged plasticity (CDP) model that accounts for the influence of mesh size. The simulation results were validated against experimental results, including mesh convergence analysis, energy balance, load characteristics, and crack patterns. A parametric study was then conducted using this model to investigate the influence of the rebar’s diameter, number, and spacing on the RC beam’s load–displacement characteristics and crack behavior. The findings demonstrate that the FE model accurately simulates the working behavior of the RC beam, with a maximum deviation at a cracking load of 8.7% and crack patterns with a maximum deviation in the mean crack height of 12.1%. In addition, the results of the parametric study suggest that the rebar configuration significantly affects the RC beam’s loading carrying capacity. This study provides deeper insights into the use of FE modeling for analyzing the behavior of RC beams, which can be useful for designing and optimizing structures in civil engineering.
- 28 October 2023
- Published by MDPI AG in Applied Sciences
- Vol. 13 (21) , 11798
Open AccessInvestigation of Load–Displacement Characteristics and Crack Behavior of RC Beam Based on Nonlinear Finite Element Analysis Using Concrete Damage Plasticity
Crack patterns provide critical information about the structural integrity and safety of concrete structures. However, until now, there has been a lack of sufficient studies on using the Finite Element (FE) method to investigate the characteristics of the crack patterns of reinforced concrete (RC) beams. Therefore, this study aims to develop an FE model to analyze the load–displacement and crack characteristics of a beam under a four-point bending test using the concrete damaged plasticity (CDP) model that accounts for the influence of mesh size. The simulation results were validated against experimental results, including mesh convergence analysis, energy balance, load characteristics, and crack patterns. A parametric study was then conducted using this model to investigate the influence of the rebar’s diameter, number, and spacing on the RC beam’s load–displacement characteristics and crack behavior. The findings demonstrate that the FE model accurately simulates the working behavior of the RC beam, with a maximum deviation at a cracking load of 8.7% and crack patterns with a maximum deviation in the mean crack height of 12.1%. In addition, the results of the parametric study suggest that the rebar configuration significantly affects the RC beam’s loading carrying capacity. This study provides deeper insights into the use of FE modeling for analyzing the behavior of RC beams, which can be useful for designing and optimizing structures in civil engineering.
- Open Access
Finite Element Modeling of Interface Behavior between Normal Concrete and Ultra-High Performance Fiber-Reinforced Concrete
The behavior at the interface between normal strength concrete (NSC) and Ultra-High Performance Fiber-Reinforced Concrete (UHPFRC) plays a crucial role in accurately predicting the capacity of UHPFRC for strengthening and repairing concrete structures. Until now, there has been a lack of sufficient finite element (FE) models for accurately predicting the behavior at the interface between NSC and UHPFRC. This study aims to investigate the structural behavior of composite members made of NSC and UHPFRC by developing a model that accurately simulates the interface between the two materials using a linear traction-separation law. Novel parameters for the surface-based cohesive model, based on the traction-separation model, were obtained and calibrated from prior experiments using analytical methods. These parameters were then integrated into seven FE models to simulate the behavior at the interface between NSC and UHPFRC in shear, tensile, and flexural tests. The accuracy of the FE models was validated using experimental data. The findings revealed that the proposed FE models could effectively predict the structural behavior of composite NSC-UHPFRC members under various working conditions. Specifically, the maximum deviations between EXP and FEA were 6.8% in ultimate load for the shear test and 15.9% and 2.8% in ultimate displacement for the tensile and flexural tests, respectively. The model can be utilized to design the use of UHPFRC and ultra-high performance fiber-reinforced shotcrete (UHPFRS) for repairing and strengthening damaged concrete structures.
Open AccessFinite Element Modeling of Interface Behavior between Normal Concrete and Ultra-High Performance Fiber-Reinforced Concrete
The behavior at the interface between normal strength concrete (NSC) and Ultra-High Performance Fiber-Reinforced Concrete (UHPFRC) plays a crucial role in accurately predicting the capacity of UHPFRC for strengthening and repairing concrete structures. Until now, there has been a lack of sufficient finite element (FE) models for accurately predicting the behavior at the interface between NSC and UHPFRC. This study aims to investigate the structural behavior of composite members made of NSC and UHPFRC by developing a model that accurately simulates the interface between the two materials using a linear traction-separation law. Novel parameters for the surface-based cohesive model, based on the traction-separation model, were obtained and calibrated from prior experiments using analytical methods. These parameters were then integrated into seven FE models to simulate the behavior at the interface between NSC and UHPFRC in shear, tensile, and flexural tests. The accuracy of the FE models was validated using experimental data. The findings revealed that the proposed FE models could effectively predict the structural behavior of composite NSC-UHPFRC members under various working conditions. Specifically, the maximum deviations between EXP and FEA were 6.8% in ultimate load for the shear test and 15.9% and 2.8% in ultimate displacement for the tensile and flexural tests, respectively. The model can be utilized to design the use of UHPFRC and ultra-high performance fiber-reinforced shotcrete (UHPFRS) for repairing and strengthening damaged concrete structures.
- Open Access
- 1 May 2020
- Published by Elsevier in KSCE Journal of Civil Engineering
- Vol. 24 (8) , 2495-2504
An Empirical Study on the Absorption of Carbon Dioxide in OLED-Mixed Concrete through Carbonation Reaction
- 1 May 2020
- Published by Elsevier in KSCE Journal of Civil Engineering
- Vol. 24 (8) , 2495-2504
Open AccessAn Empirical Study on the Absorption of Carbon Dioxide in OLED-Mixed Concrete through Carbonation Reaction
- Open Access
- 1 May 2020
- Published by Elsevier in KSCE Journal of Civil Engineering
- Vol. 24 (8) , 2485-2494
Strength Development Characteristics of Concrete Replaced with Different Waste Glasses from Display Industry as a Cementitious Material
- 1 May 2020
- Published by Elsevier in KSCE Journal of Civil Engineering
- Vol. 24 (8) , 2485-2494
Open AccessStrength Development Characteristics of Concrete Replaced with Different Waste Glasses from Display Industry as a Cementitious Material
- Open Access
Determining the Fracture Process Zone Length and Mode I Stress Intensity Factor in Concrete Structures via Mechanoluminescent Technology
The mechanoluminescent (ML) technology that is being developed as a new and substitutive technology for structural health monitoring systems (SHMS) comprises stress/strain sensing micro-/nanoparticles embedded in a suitable binder, digital imaging system, and digital image processing techniques. The potential of ML technology to reveal the fracture process zone (FPZ) that is commonly found in structural materials like concrete and to calculate the stress intensity factor (SIF) of concrete, which are crucial for SHMS, has never been done before. Therefore, the potential of ML technology to measure the length of the FPZ and to calculate the SIF has been demonstrated in this work by considering a single-edge notched bend (SENB) test of the concrete structures. The image segmentation approach based on the histogram of an ML image as well the skeletonization of an ML image have been introduced in this work to facilitate the measurement of the length of ML pattern, crack, and FPZ. The results show ML technology has the potential to determine fracture toughness, to visualize FPZ and cracks, and to measure their lengths in structural material like concrete, which makes it applicable to structural health monitoring systems (SHMS) to characterize the structural integrity of structures.
Open AccessDetermining the Fracture Process Zone Length and Mode I Stress Intensity Factor in Concrete Structures via Mechanoluminescent Technology
The mechanoluminescent (ML) technology that is being developed as a new and substitutive technology for structural health monitoring systems (SHMS) comprises stress/strain sensing micro-/nanoparticles embedded in a suitable binder, digital imaging system, and digital image processing techniques. The potential of ML technology to reveal the fracture process zone (FPZ) that is commonly found in structural materials like concrete and to calculate the stress intensity factor (SIF) of concrete, which are crucial for SHMS, has never been done before. Therefore, the potential of ML technology to measure the length of the FPZ and to calculate the SIF has been demonstrated in this work by considering a single-edge notched bend (SENB) test of the concrete structures. The image segmentation approach based on the histogram of an ML image as well the skeletonization of an ML image have been introduced in this work to facilitate the measurement of the length of ML pattern, crack, and FPZ. The results show ML technology has the potential to determine fracture toughness, to visualize FPZ and cracks, and to measure their lengths in structural material like concrete, which makes it applicable to structural health monitoring systems (SHMS) to characterize the structural integrity of structures.
- Open Access
- 2 December 2019
- Published by Elsevier in KSCE Journal of Civil Engineering
- Vol. 24 (1) , 219-227
Experimental Study on Thermal Conductivity of Concrete Using Ferronickel Slag Powder
- 2 December 2019
- Published by Elsevier in KSCE Journal of Civil Engineering
- Vol. 24 (1) , 219-227
Open AccessExperimental Study on Thermal Conductivity of Concrete Using Ferronickel Slag Powder
- Open Access
High Sulfate Attack Resistance of Reinforced Concrete Flumes Containing Liquid Crystal Display (LCD) Waste Glass Powder
To prevent chemical erosion of concrete and improve chemical resistance, reinforced concrete flumes were manufactured, conforming to the Korean Industrial Standards (KS). Two different sizes of liquid crystal display (LCD) waste glass powder (LWGP) particles were used (i.e., 5 and 12 µm) with two substitution types with cement in concrete (i.e., 10% and 20%). Changes in compressive strength, pore structure, weight, volume, and strength of the concrete flumes after immersion in two sulfate solutions (i.e., Na2SO4 and MgSO4) for 84 and 182 days were measured for sulfate attack resistance. The applicability of the LWGP concrete flume with a 0.5 mm crack width was also evaluated based on the bending strength results. The LWGP5, which has a smaller particle size among LWGPs, filled the smaller pores, thereby reducing the porosity and contributing to the compressive strength gain. Higher volume and weight change ratios for all specimens immersed in MgSO4 solution were found than those immersed in Na2SO4 solution under identical conditions. Flexural loads of all the LWGP concrete flumes with 0.05 mm crack widths were greater than 48.5 kN, as required by the KS code; however, these flexural loads were lower than those of ordinary Portland cement. The applicability was also validated via a flexural test complying with KS.
Open AccessHigh Sulfate Attack Resistance of Reinforced Concrete Flumes Containing Liquid Crystal Display (LCD) Waste Glass Powder
To prevent chemical erosion of concrete and improve chemical resistance, reinforced concrete flumes were manufactured, conforming to the Korean Industrial Standards (KS). Two different sizes of liquid crystal display (LCD) waste glass powder (LWGP) particles were used (i.e., 5 and 12 µm) with two substitution types with cement in concrete (i.e., 10% and 20%). Changes in compressive strength, pore structure, weight, volume, and strength of the concrete flumes after immersion in two sulfate solutions (i.e., Na2SO4 and MgSO4) for 84 and 182 days were measured for sulfate attack resistance. The applicability of the LWGP concrete flume with a 0.5 mm crack width was also evaluated based on the bending strength results. The LWGP5, which has a smaller particle size among LWGPs, filled the smaller pores, thereby reducing the porosity and contributing to the compressive strength gain. Higher volume and weight change ratios for all specimens immersed in MgSO4 solution were found than those immersed in Na2SO4 solution under identical conditions. Flexural loads of all the LWGP concrete flumes with 0.05 mm crack widths were greater than 48.5 kN, as required by the KS code; however, these flexural loads were lower than those of ordinary Portland cement. The applicability was also validated via a flexural test complying with KS.