KYKarim Hassan Youssef

Karim Hassan Youssef

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Karim Hassan Youssef has a total of 26 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Online Fault Detection, Classification and Localization in PV Arrays Using Feedforward Neural Networks and Residual-Based Modeling

    by Kareem Adel Mohamed, Nahla E. Zakzouk, Mostafa Abdelgeliel, Karim H. Youssef

    Fast and reliable fault detection is critical in photovoltaic (PV) systems to improve reliability and energy yield and reduce maintenance costs, ensuring safe and efficient operation under varying operating conditions. Although recent data-driven PV fault detection techniques (FDTs) in literature have demonstrated high diagnostic accuracies, they often suffer from practical limitations, offline operation, lack of fault localization and/or inability to concurrently identify faults. To address these challenges, a unified framework is proposed that simultaneously integrates real-time operation, fault classification and localization, and concurrent-fault identification in a single compact diagnostic approach. This is realized by developing a parallel feedforward neural network (FFNN) architecture whose performance is enhanced by a residual model-based structure, resulting in a more interpretable, scalable, reliable and accurate scheme. In addition, Grey Wolf Optimizer–Support Vector Machine (GWO–SVM) feature selection is incorporated to select the most influential diagnostic features, thus reducing data redundancy, enhancing diagnostic accuracy, and shortening training time. The proposed approach was tested to diagnose five types of PV faults (open circuit, short circuit, partial shading, degradation, and simultaneous faults), as well as classify their intensity and location. Simulation results show that the proposed FFNNs consistently outperform conventional Support Vector Machines (SVMs) in classification accuracy, with accuracies exceeding 98% and 99% for fault classification and localization, respectively, and above 95% for noisy data. Moreover, GWO-SVM proved to offer more stable feature subsets compared to Particle Swarm Optimization–SVM (PSO–SVM) in the considered feature selection structure. Simulation results validated the effectiveness of the proposed unified multiclassification fault diagnosis approach, even under system uncertainties, making it suited for real-world PV systems.


  • Microgrid Reliability Considering Directional Protection Failure and Optimal Load Shedding

    by Karim Hassan Youssef

    This paper addresses reliability evaluation of microgrid with distributed generation and directional protection considering protection failure. A second-order Markov-based method that considers up to two simultaneous faults and a first order approximate method have been proposed. AC Optimal Load Shedding (AC-OLS) is adopted in each state considering network constraints in all resulted islands. Simulation results are given to assess the effect of protection failure probability on reliability indices. The effects of tie-lines, loop operation, switching time, energy storage and network constraints are investigated. The proposed method can be used for studying feasibility of investment on protection upgrade and preventive maintenance to reduce protection failure probability. The proposed algorithms can also be utilized for evaluating effect of protection schemes and coordination on reliability.


  • Optimal Routing and Design of Radial Medium Voltage Power Distribution Networks Considering Cables Short Circuit Withstand-Capacity

    by Karim Hassan Youssef

    Cables short circuit withstand-capacity plays a crucial role in medium voltage distribution system design. For a given short circuit level at substation, fault current at any point in a radial distribution system depends on the location with respect to the substation, distributed generation as well as size and length of upstream cable sections. This paper addresses optimal routing, cable sizing, distributed generation allocation and sizing of radial medium voltage power distribution network considering cables short circuit withstand capacity. Both synchronous-based and inverter-based distributed generators are considered. Complete formulation of cables short circuit constraints (SCCs) is introduced in mixed-integer linear programming (MILP) form. A Benders-decomposition-based approach is used to solve the problem by considering short circuit at each system bus in a separate slave feasibility problem. Combinatorial cuts are proposed to exclude infeasible solutions in each iteration by investigating upstream routes, cable sizes and distributed generation. The proposed optimization framework and solution algorithm are applied on 54 bus, 84 bus and 138 bus systems. The results revealed potential saving in investment, maintenance and losses costs compared to upgrading method. Also the proposed solution algorithm showed great saving in the number of added constraints to the original problem.


  • Open Access

    Improved perturb and observe maximum peak power tracking for solar satellite systems

    by Kareem Adel Mohamed, Mohamed Zakareya, Karim Hassan Youssef, Hatem Awad Khater

    The aim of this work is to solve partial shading problem in solar panels to detect the global peak power point that can be used in satellite systems. This can be done by proposing a modified perturb and observe control algorithm depends on comparing all the local peak power points in photovoltaic system to detect the global one, by making initial estimation to the duty cycles of the corresponding local peak power then using perturb and observe to make fine tuning to reach the exact local peak points when oscillations happen. Also to detect the oscillations theory of operation of incremental conductance algorithm is used depending on the difference between incremental conductance and the instantaneous conductance values. The idea of operation is verified using boost converter applied in Matlab/Simulink showing good results. Also variable duty cycle is used to solve the problem of oscillations in output power.


  • Open Access

    Power quality improvement of smart microgrids using EMS-based fuzzy controlled UPQC

    by Ahmed A. Hossam-Eldin, Ahmed A. Mansour, Mohammed El-Gamal, Karim H. Youssef

    The prevalent power quality problems in smart microgrids and power distribution systems are voltage sag, voltage swell, and harmonic distortion. The achievement of pure sinusoidal waveform with proper magnitude and phase is currently a great research and development concern. The aim of this paper is to evaluate and mitigate the smart microgrid harmonics, voltage sag, and voltage swell throughout a 24-h cycle, taking into consideration the variation in solar power generation due to changes in irradiation received by photovoltaic cells, the variation in wind power generation due to changes in wind speed, and the variation of linear and nonlinear load profiles during the day’s cycle. The mitigation of the power quality issues manifested in current harmonics, voltage sag, and voltage swell is achieved through the implementation of a new fully fuzzy controlled unified power quality conditioner (UPQC). It is controlled by an energy management system (EMS). This paper introduces a new control system for the UPQC using full fuzzy logic control. Moreover, fuzzy control is used in current control instead of proportional integral controllers so that it has acceptable performance over a wide range of operating points. The novel approach of an EMS-connected UPQC activates the UPQC at the required time only into the grid. This approach has many benefits by increasing the UPQC lifetime. The effect of the proposed system on the aforementioned issues has been validated through simulation by MATLAB/Simulink. The results are compared with those obtained by conventional methods. The results verify the superior performance of the proposed UPQC to mitigate the problems of current total harmonic distortions, voltage sag, and voltage swell under different operating conditions during the monitoring period.


  • Open Access

    Indirect 3D-Space Vector Modulation for Matrix Converter

    by A. Abdelrehim, S. D. Erfan, M. El-Habrouk, K. H. Youssef

    This paper discusses the indirect space vector modulation for four-leg matrix converter. Four-leg matrix converter has been proven to be a reliable, cost-effective, and compact power electronic interface to supply unbalanced or nonlinear loads. However, the added fourth leg has shifted the inverter side modulation from simple two-dimension SVM into complex three-dimension. This paper employs a new technique to implement indirect 3D SVM in digital controllers with further simplification in the modulation process. Moreover, Simulink simulation using repetitive controller has been performed to regulate the output voltage for 400 Hz Power supplies.


  • Outdoor Performance of Micro Scale Wind Turbine Stand alone System

    by Alexandria University, Ahmed. A. Hossam-Eldin, Karim H. Youssef, Kareem M. AboRas


  • Effect of harmonics on distance relay in short and medium transmission lines

    by Fathi M. Abouelenin, Karim Hassan Youssef, Hossam Alden Bahig Hassan

    The continuous increasing in the number and the power ratings of the non-linear loads are the main sources of harmonics that affect the performance of all electrical elements. This harmonics either current or voltage harmonics have a serious effect on the quality of electricity power supply and all network elements like protection elements especially distance relays. In this paper, the effect of harmonics on distance relay is presented through a comparative study between the distance relay performance in the short and the medium models of the cable under different levels of harmonics including many components of current and voltage. This study is presented using Matlab to describe the distance relay, harmonics (current source), transmission line, fault simulation as a single line to ground fault SLG and the impedance type distance characteristic are chosen to be as the protection scheme.