JEJonathan D. Ellis

Jonathan D. Ellis

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Jonathan D. Ellis has a total of 169 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Can inertial sensors made from ultrathin fused silica flexures survive launch?

    by Jonathan D. Ellis, R. J. Hamilton, Bianka Camacho, Mohanad Warrayat, Jackson Dahn, Jeremiah Stoddart, Connor Bayliss, Shane C. Woody, Miguel Dovale, Jose Sanjuan Munoz, et al.

    Optomechanical resonators show promise as a compact and accurate architecture for inertial sensing, particularly at low frequencies. These sensors have applications in geodesy, gravimetry, seismometry, quantum physics, and fundamental physics. These particular optomechanical resonators are small test masses suspended on monolithic, paper-thin fused silica flexures. The monolithic nature of these sensors results in a high Q-factor (>100,000), and thus high inertial sensitivity. When paired with monolithic, balanced interferometry, these sensors can measure acceleration in the <100 ng/root-Hz regime at high bandwidths. The challenge with these types of sensors is their robustness. In this manuscript, we outline the mechanical design of these sensors and their specific design elements for rocket launch survivability. We also present results on their performance before and after subjecting the sensors to random vibrations for expected launch conditions.

  • Multiphoton scaling of femtosecond laser-induced refractive index change (LIRIC) in hydrogels and rabbit cornea

    by Kaitlin T. Wozniak, Zachary A. Manning, Ruiting Huang, Steven Cox, Sam C. Butler, Sebastian Ferlo, Len Zheleznyak, Lisen Xu, Jonathan D. Ellis, Krystel R. Huxlin, et al.

    To find optimal conditions for performing laser induced refractive index change (LIRIC) in living eyes with both safety and efficacy, we investigated multiphoton excitation scaling of this procedure in hydrogel and excised corneal tissue. Three distinct wavelength modalities were examined: high-repetition-rate (HRR) and low-repetition-rate (LRR) 405 nm systems, as well as 800 nm and 1035 nm systems, whose LIRIC-inducing properties are described for the first time. Of all the systems, LRR 405 nm-LIRIC was able to produce the highest phase shifts at the lowest average laser powers. Relative merits and drawbacks to each modality are discussed as they relate to future efforts towards LIRIC-based refractive error correction in humans.


  • Pixel MTF response effect on non-null interferometry

    by Martin Tangari Larrategui, Yanqi Zhang, Thomas G. Brown, Jonathan D. Ellis

    The pixel modulation transfer function response degrades the contrast of non-null interferometric surface figure measurements. We experimentally quantify this effect for spatial frequencies ranging from 0 to 363 lp/mm ( ≈ 3.33 times the Nyquist limit). Our results show a low SNR spatial frequency band that behaves like a low-pass filter for sub-Nyquist interferometry and a stop-band filter for multiple-wavelength phase-shifting interferometry. We also introduce a multiple-mode, multiple-wavelength interferometry approach to measure optical surfaces with slope departure angles mapping to spatial frequencies in this low SNR band. The extended measurement range of this approach is achieved without using a sparse-array detector.


  • Temporal evolution of the biological response to laser-induced refractive index change (LIRIC) in rabbit corneas

    by Kaitlin T. Wozniak, Sam C. Butler, Xu He, Jonathan D. Ellis, Wayne H. Knox, Krystel R. Huxlin


  • Advances in optical metrology and instrumentation: introduction

    by Jonathan D. Ellis, Han Haitjema, Xiangqian Jiang, Ki-Nam Joo, Richard Leach

    Optical measurement and characterization are two of the pillars of metrology. The ability to measure precisely with high dynamic range and accuracy betters our understanding of nature and the universe. In this feature issue, we present a collection of articles that delves into the fundamental techniques used to advance the field.


  • Open Access

    A compact high-precision periodic-error-free heterodyne interferometer

    by Ki-Nam Joo, Erin Clark, Yanqi Zhang, Jonathan D. Ellis, Felipe Guzmán

    We present the design, bench-top setup, and experimental results of a compact heterodyne interferometer that achieves picometer-level displacement sensitivities in air over frequencies above 100 MHz. The optical configuration with spatially separated beams prevents frequency and polarization mixing, and therefore eliminates periodic errors. The interferometer is designed to maximize common-mode optical laser beam paths to obtain high rejection of environmental disturbances, such as temperature fluctuations and acoustics. The results of our experiments demonstrate the short- and long-term stabilities of the system during stationary and dynamic measurements. In addition, we provide measurements that compare our interferometer prototype with a commercial system, verifying our higher sensitivity of 3 pm, higher thermal stability by a factor of two, and periodic-error-free performance.


  • Prospective longitudinal investigation shows correlation of event-related potential to mild traumatic brain injury in adolescents

    by Offir Laufer, Amir Geva, Jonathan D. Ellis, Kim Barber Foss, Maayan Ettinger, Yaki Stern, Todd Arthur, Jeffrey Kutcher, Gregory Myer, Amit Reches

    Prospective longitudinal cohort study Adolescent athletes may be more susceptible to the long-term effects of mild traumatic brain injury (mTBI). A diagnostic and prognostic neuromarker may optimize management and return-to-activity decision-making in athletes who experience mTBI. Measure an event-related potential (ERP) component captured with electroencephalography (EEG), called processing negativity (PN), at baseline and post-injury in adolescents who suffered mTBI and determine their longitudinal response relative to healthy controls. Thirty adolescents had EEG recorded during an auditory oddball task at a pre-mTBI baseline session and subsequent post-mTBI sessions. Longitudinal EEG data from patients and healthy controls (n= 77) were obtained from up to four sessions in total and processed using Brain Network Analysis algorithms. The average PN amplitude in healthy controls significantly decreased over sessions 2 and 3; however, it remained steady in the mTBI group’s 2nd (post-mTBI) session and decreased only in sessions 3 and 4. Pre- to post-mTBI amplitude changes correlated with the time interval between sessions. These results demonstrate that PN amplitude changes may be associated with mTBI exposure and subsequent recovery in adolescent athletes. Further study of PN may lead to it becoming a neuromarker for mTBI prognosis and return-to-activity decision-making in adolescents.


  • Contrasting cellular damage after Blue-IRIS and Femto-LASIK in cat cornea

    by Kaitlin T. Wozniak, Noah Elkins, Daniel R. Brooks, Daniel E. Savage, Scott MacRae, Jonathan D. Ellis, Wayne H. Knox, Krystel R. Huxlin


  • Two-dimensional straightness measurement based on optical knife-edge sensing

    by Chen Wang, Fenghe Zhong, Jonathan D. Ellis

    Straightness error is a parasitic translation along a perpendicular direction to the primary displacement axis of a linear stage. The parasitic translations could be coupled into other primary displacement directions of a multi-axis platform. Hence, its measurement and compensation are critical in precision multi-axis metrology, calibration, and manufacturing. This paper presents a two-dimensional (2D) straightness measurement configuration based on 2D optical knife-edge sensing, which is simple, light-weight, compact, and easy to align. It applies a 2D optical knife-edge to manipulate the diffraction pattern sensed by a quadrant photodetector, whose output voltages could derive 2D straightness errors after a calibration process. This paper analyzes the physical model of the configuration and performs simulations and experiments to study the system sensitivity, measurement nonlinearity, and error sources. The results demonstrate that the proposed configuration has higher sensitivity and insensitive to beam’s vibration, compared with the conventional configurations without using the knife-edge, and could achieve ±0.25 μ m within a ±40 μ m measurement range along a 40 mm primary axial motion.