Schadrack Nsengiyumva
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Schadrack Nsengiyumva has a total of 50 co-authors. Here are the top co-authors by number of shared publications:
- Abdulrafiu Tunde Raji
University of South Africa
8 shared publications - Luc Pichon
Institut Prime, UPR 3346 CNRS-Université de Poitiers-ENSMA, France
6 shared publications D.T. Britton
University of Cape Town
5 shared publicationsM. Härting
University of Cape Town 4 NanoSciences Innovation Center, Department of Physics Rondebosch 7701, South Africa
5 shared publications- Riccardo Mazzarello
Department of Physics Sapienza University of Rome Rome Italy
4 shared publications - Sandro Scandolo
The Abdus Salam International Centre for Theoretical Physics , Trieste 34151
4 shared publications
Latest Publications
- 19 January 2023
- Published by Taylor & Francis in Radiation Effects and Defects in Solids
- Vol. 178 (5-6) , 634-653
Evaluation of argon ion impact parameters in aluminium oxide by means of SRIM program and investigation of the effect of argon ion implantation on the thermoluminescence properties aluminium oxide
The thermoluminescence properties of aluminium oxide (alumina) implanted with 80 keV argon ions at fluences in the range of were investigated. The unimplanted and implanted samples were irradiated at a dose of 40 Gy and heated at a rate of 1°C/s. The glow curve of unimplanted and implanted samples shows 5 distinct peaks; the main dosimetric peak and four other peaks of lower intensity. In this study, our analysis has focussed on the main dosimetric peak located at 180°C, 191°C, 177°C, 208°C, 219°C and 207°C for the unimplanted sample and implanted samples respectively. It was observed that the TL intensity decreases with fluence of implantation. This suggests that ion implantation decreases the concentration of electron traps responsible for thermoluminescence. It can also be suggested that competition effects involving radiative pathways and non-radiative competitor traps may lead to a low thermoluminescence signal in the implanted samples in comparison to the unimplanted thermoluminescence signal. These competitive processes will tend to favour first-order kinetics, and consequently lead to a strong stability of the glow curve shapes. The creation of defect clusters as well as extended defects could also be responsible for the reduction in TL signal. The stopping and range of atoms in matter (SRIM) was used to evaluate the ion impact parameters including ion range, vacancy distribution and energy loss in Al2O3. Subsequent to ion implantation, it was found that the number of oxygen vacancies which are related to electron traps are higher than the number of aluminium vacancies. Kinetic analysis was carried out by means of the initial rise, Chen’s peak shape, various heating rate, the whole glow curve, glow curve fitting and isothermal decay methods. The activation energy was found to be around and the frequency factor to be of the order regardless of the implantation fluence. The dosimetric features of samples were also investigated at doses in the range of 40–200 Gy. Samples generally showed a superlinear response at doses less than 140 Gy and sublinear response at doses higher than 160 Gy.- 19 January 2023
- Published by Taylor & Francis in Radiation Effects and Defects in Solids
- Vol. 178 (5-6) , 634-653
Evaluation of argon ion impact parameters in aluminium oxide by means of SRIM program and investigation of the effect of argon ion implantation on the thermoluminescence properties aluminium oxide
The thermoluminescence properties of aluminium oxide (alumina) implanted with 80 keV argon ions at fluences in the range of were investigated. The unimplanted and implanted samples were irradiated at a dose of 40 Gy and heated at a rate of 1°C/s. The glow curve of unimplanted and implanted samples shows 5 distinct peaks; the main dosimetric peak and four other peaks of lower intensity. In this study, our analysis has focussed on the main dosimetric peak located at 180°C, 191°C, 177°C, 208°C, 219°C and 207°C for the unimplanted sample and implanted samples respectively. It was observed that the TL intensity decreases with fluence of implantation. This suggests that ion implantation decreases the concentration of electron traps responsible for thermoluminescence. It can also be suggested that competition effects involving radiative pathways and non-radiative competitor traps may lead to a low thermoluminescence signal in the implanted samples in comparison to the unimplanted thermoluminescence signal. These competitive processes will tend to favour first-order kinetics, and consequently lead to a strong stability of the glow curve shapes. The creation of defect clusters as well as extended defects could also be responsible for the reduction in TL signal. The stopping and range of atoms in matter (SRIM) was used to evaluate the ion impact parameters including ion range, vacancy distribution and energy loss in Al2O3. Subsequent to ion implantation, it was found that the number of oxygen vacancies which are related to electron traps are higher than the number of aluminium vacancies. Kinetic analysis was carried out by means of the initial rise, Chen’s peak shape, various heating rate, the whole glow curve, glow curve fitting and isothermal decay methods. The activation energy was found to be around and the frequency factor to be of the order regardless of the implantation fluence. The dosimetric features of samples were also investigated at doses in the range of 40–200 Gy. Samples generally showed a superlinear response at doses less than 140 Gy and sublinear response at doses higher than 160 Gy.- 10 July 2019
- Published by Taylor & Francis in Radiation Effects and Defects in Solids
- Vol. 174 (7-8) , 708-720
Thermoluminescence and fluorescence studies of argon-implanted aluminium oxide
Thermoluminescence (TL) and fluorescence studies of aluminium oxide (Al2O3) implanted with 80 keV argon ions at fluences in the range 1 × 1014–1011 × 1016 ions/cm2 are presented. Thermoluminescence measurements were made at 1°C/s subsequent to irradiation to 20 Gy. The glow curve consists of a prominent peak centred at 170°C, the subject of this study, and three secondary peaks of weaker intensity centred at 242, 306, and 450°C. It is observed that the TL sensitivity of the main peak decreases with fluence of implantation. This suggests that ion implantation reduces the concentration of trapping centres responsible for the thermoluminescence. Kinetic analysis carried out by means of the variable heating rate, whole glow peak and curve fitting methods shows that the activation energy of the main peak is about 1.00 eV and the frequency factor of the order of 1010 s−1 irrespective of ion fluence. Fluorescence studies show emission bands at around 436, 676, 695 and 754 nm. These emission bands may be attributed to -centres or Cr3+ impurities substituting for aluminium. Scanning electron microscopy images taken from the samples indicate that their surface morphology remains the same irrespective of the implantation fluence.- 10 July 2019
- Published by Taylor & Francis in Radiation Effects and Defects in Solids
- Vol. 174 (7-8) , 708-720
Thermoluminescence and fluorescence studies of argon-implanted aluminium oxide
Thermoluminescence (TL) and fluorescence studies of aluminium oxide (Al2O3) implanted with 80 keV argon ions at fluences in the range 1 × 1014–1011 × 1016 ions/cm2 are presented. Thermoluminescence measurements were made at 1°C/s subsequent to irradiation to 20 Gy. The glow curve consists of a prominent peak centred at 170°C, the subject of this study, and three secondary peaks of weaker intensity centred at 242, 306, and 450°C. It is observed that the TL sensitivity of the main peak decreases with fluence of implantation. This suggests that ion implantation reduces the concentration of trapping centres responsible for the thermoluminescence. Kinetic analysis carried out by means of the variable heating rate, whole glow peak and curve fitting methods shows that the activation energy of the main peak is about 1.00 eV and the frequency factor of the order of 1010 s−1 irrespective of ion fluence. Fluorescence studies show emission bands at around 436, 676, 695 and 754 nm. These emission bands may be attributed to -centres or Cr3+ impurities substituting for aluminium. Scanning electron microscopy images taken from the samples indicate that their surface morphology remains the same irrespective of the implantation fluence.- 1 October 2016
- Published by Elsevier in Nuclear Instruments and Methods in Physics Research Section B: Beam Interactions with Materials and Atoms
- Vol. 384, 50-60
Oxygen depth profiling by resonant backscattering and glow discharge optical emission spectroscopy of Ti-6Al-4V alloy oxidized by ion implantation and plasma based treatment
- 1 October 2016
- Published by Elsevier in Nuclear Instruments and Methods in Physics Research Section B: Beam Interactions with Materials and Atoms
- Vol. 384, 50-60
Oxygen depth profiling by resonant backscattering and glow discharge optical emission spectroscopy of Ti-6Al-4V alloy oxidized by ion implantation and plasma based treatment
- 3 March 2016
- Published by Taylor & Francis in Radiation Effects and Defects in Solids
- Vol. 171 (3-4) , 328-339
Influence of argon-implantation on conventional and phototransferred thermoluminescence of synthetic quartz
Conventional and phototransferred thermoluminescence of crystalline synthetic quartz implanted with 70 keV Ar ions at fluences in the range 1 × 1014–5 × 1015 ions/cm2 is reported. The glow curves, recorded at 5°C/s from beta-irradiated samples of similar mass, show a prominent peak between 100°C and 120°C. The thermoluminescence intensity of all implanted samples was greater than that of the unimplanted one. The increase in sensitivity is attributed to a corresponding increase in the concentration of point defects, as a result of the implantation, which act as electron traps or recombination centres. Kinetic analysis carried out using the peak shape, whole glow-peak and curve-fitting methods produced values of the activation energy, frequency factor and order of kinetics that are generally independent of implantation fluence. This result suggests that implantation did not necessarily affect the nature of the electron traps. With respect to phototransferred thermoluminescence, it was observed that it only appeared in the sample implanted at the highest fluence of 5 × 1015 ions/cm2. This may be so because the concentration of deep traps produced as a result of implantation at low fluence is too low to give rise to phototransferred thermoluminescence. The intensity of the phototransferred thermoluminescence goes through a peak with illumination time. We attribute this behaviour to the relative concentration of holes at recombination centres and phototransferred electrons at shallow traps.
- 3 March 2016
- Published by Taylor & Francis in Radiation Effects and Defects in Solids
- Vol. 171 (3-4) , 328-339
Influence of argon-implantation on conventional and phototransferred thermoluminescence of synthetic quartz
Conventional and phototransferred thermoluminescence of crystalline synthetic quartz implanted with 70 keV Ar ions at fluences in the range 1 × 1014–5 × 1015 ions/cm2 is reported. The glow curves, recorded at 5°C/s from beta-irradiated samples of similar mass, show a prominent peak between 100°C and 120°C. The thermoluminescence intensity of all implanted samples was greater than that of the unimplanted one. The increase in sensitivity is attributed to a corresponding increase in the concentration of point defects, as a result of the implantation, which act as electron traps or recombination centres. Kinetic analysis carried out using the peak shape, whole glow-peak and curve-fitting methods produced values of the activation energy, frequency factor and order of kinetics that are generally independent of implantation fluence. This result suggests that implantation did not necessarily affect the nature of the electron traps. With respect to phototransferred thermoluminescence, it was observed that it only appeared in the sample implanted at the highest fluence of 5 × 1015 ions/cm2. This may be so because the concentration of deep traps produced as a result of implantation at low fluence is too low to give rise to phototransferred thermoluminescence. The intensity of the phototransferred thermoluminescence goes through a peak with illumination time. We attribute this behaviour to the relative concentration of holes at recombination centres and phototransferred electrons at shallow traps.
- 2 January 2015
- Published by Taylor & Francis in Radiation Effects and Defects in Solids
- Vol. 170 (1) , 18-29
Influence of nitrogen implantation on thermoluminescence of synthetic quartz
- 2 January 2015
- Published by Taylor & Francis in Radiation Effects and Defects in Solids
- Vol. 170 (1) , 18-29
Influence of nitrogen implantation on thermoluminescence of synthetic quartz
- 29 October 2014
- Published by Taylor & Francis in Radiation Effects and Defects in Solids
- Vol. 169 (11) , 919-930
Influence of nitrogen implantation on thermoluminescence of synthetic quartz
Thermoluminescence (TL) of synthetic quartz exposed to beta irradiation following implantation with 60 keV N+ ions at fluences ranging between 1 × 1014 and 5 × 1015 ions/cm2 is reported. The glow curve measured at 5°C/s typically consists of a prominent peak near 110°C, studied in this work, and minor glow peaks at around 130°C and 190°C. The TL intensity of the main peak increased both with implantation and with fluence of implantation. The dependence of the intensity on heating rate and fluence suggests that the implantation introduces new defects that may possibly act as recombination centres. The increase in TL intensity with the heating rate exhibited by implanted samples has been observed in other luminescence materials. This anti-quenching phenomenon has been described as a competition effect between multiple luminescence pathways in luminescence materials. Kinetic analysis of the main glow peak using the initial rise, various heating rate and glow curve deconvolution methods shows that the activation energy of the main peak is about 0.7 eV with no systematic change due to ion fluence.
- 29 October 2014
- Published by Taylor & Francis in Radiation Effects and Defects in Solids
- Vol. 169 (11) , 919-930
Influence of nitrogen implantation on thermoluminescence of synthetic quartz
Thermoluminescence (TL) of synthetic quartz exposed to beta irradiation following implantation with 60 keV N+ ions at fluences ranging between 1 × 1014 and 5 × 1015 ions/cm2 is reported. The glow curve measured at 5°C/s typically consists of a prominent peak near 110°C, studied in this work, and minor glow peaks at around 130°C and 190°C. The TL intensity of the main peak increased both with implantation and with fluence of implantation. The dependence of the intensity on heating rate and fluence suggests that the implantation introduces new defects that may possibly act as recombination centres. The increase in TL intensity with the heating rate exhibited by implanted samples has been observed in other luminescence materials. This anti-quenching phenomenon has been described as a competition effect between multiple luminescence pathways in luminescence materials. Kinetic analysis of the main glow peak using the initial rise, various heating rate and glow curve deconvolution methods shows that the activation energy of the main peak is about 0.7 eV with no systematic change due to ion fluence.
- 11 July 2014
- Published by AIP Publishing in Journal of Applied Physics
- Vol. 116 (2) , 023513
Stress enhanced diffusion of krypton ions in polycrystalline titanium
An experimental investigation on the mutual influence of pre-existing residual stress and point defect following ion implantation is presented. The study has been carried out using polycrystalline titanium samples energetically implanted with krypton ions at different fluences. Ion beam analysis was used to determine the concentration profile of the injected krypton ions, while synchrotron X-ray diffraction has been used for stress determination. Ion beam analysis and synchrotron X-ray diffraction stress profile measurements of the implanted titanium samples show a clear evidence of stress-enhanced diffusion of krypton ions in titanium. It is further observed that for the titanium samples implanted at low fluence, ion implantation modifies the pre-existing residual stress through the introduction of point and open volume defects. The stress fields resulting from the ion implantation act to drift the krypton inclusions towards the surface of titanium.
- 11 July 2014
- Published by AIP Publishing in Journal of Applied Physics
- Vol. 116 (2) , 023513
Stress enhanced diffusion of krypton ions in polycrystalline titanium
An experimental investigation on the mutual influence of pre-existing residual stress and point defect following ion implantation is presented. The study has been carried out using polycrystalline titanium samples energetically implanted with krypton ions at different fluences. Ion beam analysis was used to determine the concentration profile of the injected krypton ions, while synchrotron X-ray diffraction has been used for stress determination. Ion beam analysis and synchrotron X-ray diffraction stress profile measurements of the implanted titanium samples show a clear evidence of stress-enhanced diffusion of krypton ions in titanium. It is further observed that for the titanium samples implanted at low fluence, ion implantation modifies the pre-existing residual stress through the introduction of point and open volume defects. The stress fields resulting from the ion implantation act to drift the krypton inclusions towards the surface of titanium.
- 31 December 2011
- Published by Elsevier in Solid State Communications
- Vol. 151 (24) , 1889-1893
Defects in ion-implanted hcp-titanium: A first-principles study of electronic structures
- 31 December 2011
- Published by Elsevier in Solid State Communications
- Vol. 151 (24) , 1889-1893
Defects in ion-implanted hcp-titanium: A first-principles study of electronic structures