Takuya Maeyama
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Takuya Maeyama has a total of 92 co-authors. Here are the top co-authors by number of shared publications:
- Shinichi Yamashita
Department of Nuclear Engineering and Management, School of Engineering, The University of Tokyo
5 shared publications - Yusuke Watanabe
School of Allied Health Sciences, Kitasato University, Kanagawa, Japan
5 shared publications Anri Mochizuki
Department of Chemistry, School of Science Kitasato University Sagamihara Kanagawa Japan
4 shared publications- Gerard Baldacchino
LIDYL, CEA, CNRS, Université Paris-Saclay, F-91191 Gif-sur-Yvette, France
4 shared publications K. Fukasaku
4 shared publicationsKenichi L. Ishikawa
4 shared publications
Latest Publications
- 11 September 2026
- Published by Elsevier in Physica Medica
- Vol. 150
Preliminary investigation of iodine-doped MR-based polymer gel dosimeter for fiducial-free tumour-tracking radiotherapy
- 11 September 2026
- Published by Elsevier in Physica Medica
- Vol. 150
Preliminary investigation of iodine-doped MR-based polymer gel dosimeter for fiducial-free tumour-tracking radiotherapy
- Open Access
- 29 October 2024
- Published by IOP Publishing in Biomedical Physics & Engineering Express
- Vol. 10 (6) , 065049
Time-resolved observation of DHR123 nano-clay radio-fluorogenic gel dosimeters by photoluminescence-detected pulse radiolysis
The importance of real-time dose evaluation has increased for recent advanced radiotherapy. However, conventional methods for real-time dosimetry using gel dosimeters face challenges owing to the delayed dose response caused by the slow completion of radiation-induced chemical reactions. In this study, a novel technique called photoluminescence-detected pulse radiolysis (PLPR) was developed, and its potential to allow real-time dose measurements using nano-clay radio-fluorogenic gel (NC-RFG) dosimeters was investigated. PLPR is a time-resolved observation method, and enables time-resolved fluorescence measurement. NC-RFG dosimeters were prepared, typically consisting of 100 μM dihydrorhodamine 123 (DHR123) and 2.0 wt.% nano-clay, along with catalytic and dissolving additives. We successfully achieved time-resolved observation of the increase in fluorescence intensity upon irradiation of the dosimeter. Dose evaluation was possible at 1 s after irradiation. The dose-rate effect was not observed for the deoxygenated dosimeter, but was observed for the aerated dosimeter. Besides the dose-rate effect, linear dose responses were obtained for both conditions. Furthermore, we made a novel observation of a decay in the fluorescence intensity over time in the early stages which named fluorescence secondary loss (FSL) and elucidated the conditions under which this phenomenon occurs.
- 29 October 2024
- Published by IOP Publishing in Biomedical Physics & Engineering Express
- Vol. 10 (6) , 065049
Open AccessTime-resolved observation of DHR123 nano-clay radio-fluorogenic gel dosimeters by photoluminescence-detected pulse radiolysis
The importance of real-time dose evaluation has increased for recent advanced radiotherapy. However, conventional methods for real-time dosimetry using gel dosimeters face challenges owing to the delayed dose response caused by the slow completion of radiation-induced chemical reactions. In this study, a novel technique called photoluminescence-detected pulse radiolysis (PLPR) was developed, and its potential to allow real-time dose measurements using nano-clay radio-fluorogenic gel (NC-RFG) dosimeters was investigated. PLPR is a time-resolved observation method, and enables time-resolved fluorescence measurement. NC-RFG dosimeters were prepared, typically consisting of 100 μM dihydrorhodamine 123 (DHR123) and 2.0 wt.% nano-clay, along with catalytic and dissolving additives. We successfully achieved time-resolved observation of the increase in fluorescence intensity upon irradiation of the dosimeter. Dose evaluation was possible at 1 s after irradiation. The dose-rate effect was not observed for the deoxygenated dosimeter, but was observed for the aerated dosimeter. Besides the dose-rate effect, linear dose responses were obtained for both conditions. Furthermore, we made a novel observation of a decay in the fluorescence intensity over time in the early stages which named fluorescence secondary loss (FSL) and elucidated the conditions under which this phenomenon occurs.
- 27 October 2024
- Published by Elsevier in New Scientist
- Vol. 264 (3514) , 51
Bad pot luck
- Open Access
- 24 September 2024
- Published by Elsevier in Chemical Physics Letters
- Vol. 856
Ionizing radiation induced reaction in nanoclay hydrogel
- 24 September 2024
- Published by Elsevier in Chemical Physics Letters
- Vol. 856
Open AccessIonizing radiation induced reaction in nanoclay hydrogel
- Open Access
- 15 March 2024
- Published by Japan Radioisotope Association in RADIOISOTOPES
- Vol. 73 (1) , 23-34
Development of 3D Gel Dosimeter with Nanoclay for Radiotherapy—LET-independent Radio-fluorogenic Gel Dosimeter—
重粒子線治療は,線量の集中性が高く細胞致死効果の高い重粒子線を病巣に集中的に照射する効果的な治療法である。しかし,重粒子線に対するほとんどの物質の線量応答は線エネルギー付与(LET)を通して重粒子線のエネルギーに依存するため,その線量分布を正確に計測することは困難であった。本稿では,高LET放射線の分布を数Gy単位で定量,サブミリメートルの分解能で評価でき,その線量応答がLETに依存しない化学線量計を紹介する。
- 15 March 2024
- Published by Japan Radioisotope Association in RADIOISOTOPES
- Vol. 73 (1) , 23-34
Open AccessDevelopment of 3D Gel Dosimeter with Nanoclay for Radiotherapy—LET-independent Radio-fluorogenic Gel Dosimeter—
重粒子線治療は,線量の集中性が高く細胞致死効果の高い重粒子線を病巣に集中的に照射する効果的な治療法である。しかし,重粒子線に対するほとんどの物質の線量応答は線エネルギー付与(LET)を通して重粒子線のエネルギーに依存するため,その線量分布を正確に計測することは困難であった。本稿では,高LET放射線の分布を数Gy単位で定量,サブミリメートルの分解能で評価でき,その線量応答がLETに依存しない化学線量計を紹介する。
- 30 September 2023
- Published by Elsevier in Physica Medica
- Vol. 114, 102684
Development of a silicone-based radio-fluorogenic dosimeter using dihydrorhodamine 6G
- 30 September 2023
- Published by Elsevier in Physica Medica
- Vol. 114, 102684
Development of a silicone-based radio-fluorogenic dosimeter using dihydrorhodamine 6G
- 29 November 2022
- Published by Wiley in Medical Physics
- Vol. 50 (2) , 1073-1085
Radio‐fluorogenic nanoclay gel dosimeters with reduced linear energy transfer dependence for carbon‐ion beam radiotherapy
PurposeThe precise assessment of the dose distribution of high linear energy transfer (LET) radiation remains a challenge, because the signal of most dosimeters will be saturated due to the high ionization density. Such measurements are particularly important for heavy-ion beam cancer therapy. On this basis, the present work examined the high LET effect associated with three-dimensional gel dosimetry based on radiation-induced chemical reactions. The purpose of this study was to create an ion beam radio-fluorogenic gel dosimeter with a reduced effect of LET. MethodsNanoclay radio-fluorogenic gel (NC-RFG) dosimeters were prepared, typically containing 100 mu M dihydrorhodamine 123 (DHR123) and 2.0 wt% nanoclay together with catalytic additives promoting Fenton or Fenton-like reactions. The radiological properties of NC-RFG dosimeters having different compositions in response to a carbon-ion beam were investigated using a fluorescence gel scanner. ResultsAn NC-RFG dosimeter capable of generating a fluorescence intensity distribution reflecting the carbon-ion beam dose profile was obtained. It was clarified that the reduction of the unfavorable LET dependence results from an acceleration of the reactions between DHR123 and H2O2, which is a molecular radiolysis product. The effects of varying the preparation conditions on the radiological properties of these gels were also examined. The optimum H2O2 catalyst was determined to include 1 mM Fe3+ ions, and the addition of 100 mM pyridine was also found to increase the sensitivity. ConclusionsThis technique allows the first-ever evaluation of the depth-dose profile of a carbon-ion beam at typical therapeutic levels of several Gy without LET effect.
- 29 November 2022
- Published by Wiley in Medical Physics
- Vol. 50 (2) , 1073-1085
Radio‐fluorogenic nanoclay gel dosimeters with reduced linear energy transfer dependence for carbon‐ion beam radiotherapy
PurposeThe precise assessment of the dose distribution of high linear energy transfer (LET) radiation remains a challenge, because the signal of most dosimeters will be saturated due to the high ionization density. Such measurements are particularly important for heavy-ion beam cancer therapy. On this basis, the present work examined the high LET effect associated with three-dimensional gel dosimetry based on radiation-induced chemical reactions. The purpose of this study was to create an ion beam radio-fluorogenic gel dosimeter with a reduced effect of LET. MethodsNanoclay radio-fluorogenic gel (NC-RFG) dosimeters were prepared, typically containing 100 mu M dihydrorhodamine 123 (DHR123) and 2.0 wt% nanoclay together with catalytic additives promoting Fenton or Fenton-like reactions. The radiological properties of NC-RFG dosimeters having different compositions in response to a carbon-ion beam were investigated using a fluorescence gel scanner. ResultsAn NC-RFG dosimeter capable of generating a fluorescence intensity distribution reflecting the carbon-ion beam dose profile was obtained. It was clarified that the reduction of the unfavorable LET dependence results from an acceleration of the reactions between DHR123 and H2O2, which is a molecular radiolysis product. The effects of varying the preparation conditions on the radiological properties of these gels were also examined. The optimum H2O2 catalyst was determined to include 1 mM Fe3+ ions, and the addition of 100 mM pyridine was also found to increase the sensitivity. ConclusionsThis technique allows the first-ever evaluation of the depth-dose profile of a carbon-ion beam at typical therapeutic levels of several Gy without LET effect.
- Open Access
Whole Three-Dimensional Dosimetry of Carbon Ion Beams with an MRI-Based Nanocomposite Fricke Gel Dosimeter Using Rapid T1 Mapping Method
MRI-based gel dosimeters are attractive systems for the evaluation of complex dose distributions in radiotherapy. In particular, the nanocomposite Fricke gel dosimeter is one among a few dosimeters capable of accurately evaluating the dose distribution of heavy ion beams. In contrast, reduction of the scanning time is a challenging issue for the acquisition of three-dimensional volume data. In this study, we investigated a three-dimensional dose distribution measurement method for heavy ion beams using variable flip angle (VFA), which is expected to significantly reduce the MRI scanning time. Our findings clarified that the whole three-dimensional dose distribution could be evaluated within the conventional imaging time (20 min) and quality of one cross-section.
Open AccessWhole Three-Dimensional Dosimetry of Carbon Ion Beams with an MRI-Based Nanocomposite Fricke Gel Dosimeter Using Rapid T1 Mapping Method
MRI-based gel dosimeters are attractive systems for the evaluation of complex dose distributions in radiotherapy. In particular, the nanocomposite Fricke gel dosimeter is one among a few dosimeters capable of accurately evaluating the dose distribution of heavy ion beams. In contrast, reduction of the scanning time is a challenging issue for the acquisition of three-dimensional volume data. In this study, we investigated a three-dimensional dose distribution measurement method for heavy ion beams using variable flip angle (VFA), which is expected to significantly reduce the MRI scanning time. Our findings clarified that the whole three-dimensional dose distribution could be evaluated within the conventional imaging time (20 min) and quality of one cross-section.