KHKoichi Hamada

Koichi Hamada

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Koichi Hamada has a total of 121 co-authors. Here are the top co-authors by number of shared publications:

  • Yoshinori Horikawa

    Southern Tohoku Research Institute for Neuroscience, Southern Tohoku General Hospital, Fukushima, Japan

    14 shared publications
  • Kae Techigawara

    Southern Tohoku Research Institute for Neuroscience, Southern Tohoku General Hospital, Fukushima, Japan

    13 shared publications
  • Michitaka Honda

    Department of Minimally Invasive Surgical and Medical Oncology, Fukushima Medical University, Fukushima, Japan; Department of Surgery, Southern-Tohoku General Hospital, Koriyama, Japan

    11 shared publications
  • Yoshiki Shiwa

    Southern Tohoku Gen Hosp, Dept Gastroenterol, 7-115,Yatsuyamada, Koriyama, Fukushima 9638563, Japan

    11 shared publications
  • Noriyuki Nishino

    Southern Tohoku Gen Hosp, Dept Gastroenterol, 7-115,Yatsuyamada, Koriyama, Fukushima 9638563, Japan

    10 shared publications
  • Masafumi Ishikawa

    Southern Tohoku Research Institute for Neuroscience, Southern Tohoku General Hospital, Fukushima, Japan

    8 shared publications

Latest Publications

  • Open Access

    The potential modulating role of thyroid cysts on the association between anti–thyroid peroxidase antibodies and subclinical hypothyroidism

    by Yuji Shimizu, Nagisa Sasaki, Asuka Oyama, Yuko Noguchi, Mutsumi Matsuu-Matsuyama, Koichiro Hamada, Shin-Ya Kawashiri, Hirotomo Yamanashi, Seiko Nakamichi, Yasuhiro Nagata, et al.

    Background: In our previous study, the absence of thyroid cysts was identified as an indicator of thyroid functional strain associated with thyroid peroxidase antibody (TPO-Ab) positivity. In individuals under this continuous functional load, higher levels of thyroid-stimulating hormone are required to maintain serum thyroid hormone concentrations within the normal range, potentially leading to subclinical hypothyroidism (SCH). However, no study has examined whether the association between TPO-Ab positivity and SCH differs according to thyroid cyst status. Method: We conducted a cross-sectional study of 1432 euthyroid Japanese participants whose free triiodothyronine (T3) and free thyroxine levels were within normal ranges. Thyroid cysts were defined as cystic lesions with a maximum diameter ≥ 2.0 mm and no solid components. Results: Among the study population, 964 participants had no thyroid cysts, 267 were TPO-Ab positive, and 80 had SCH. A significant positive association between TPO-Ab positivity and SCH was observed only in participants without thyroid cysts. After adjustment for potential confounders—including sex, age, free T3, body mass index, atherosclerosis, and hypertension—the adjusted odds ratios (95% confidence intervals) were 0.27 (0.04, 2.02) and 2.10 (1.17, 3.77) for participants with and without thyroid cysts, respectively. Conclusion: Among participants without thyroid cysts, TPO-Ab positivity was significantly associated with SCH, whereas no significant association was observed among those with thyroid cysts likely due to the small sample size. Reflecting a significant interaction between these factors, thyroid cyst status may modulate the association between TPO-Ab positivity and SCH, although further large-scale investigation is warranted.

  • Open Access

    Novel gel-flush rescue technique for an impacted detachable snare sheath in the working channel during polypectomy

    by Koichi Hamada, Masafumi Ishikawa, Yoshinori Horikawa, Kae Techigawara, Takayuki Nagahashi, Takuro Nakaya, Akane Yamabe

  • Response

    by Koichi Hamada, Michitaka Honda, Tamotsu Sugai

  • Open Access

    Optimization of traction-device length and traction force during gastric endoscopic submucosal dissection

    by Koichi Hamada, Yoshinori Horikawa, Kae Techigawara, Takayuki Nagahashi, Masafumi Ishikawa, Michitaka Honda, Tamotsu Sugai

    Various traction methods, including intraluminal traction for endoscopic submucosal dissection (ESD), have proven useful [1] [2]. Due to the stomach’s complex shape, devices providing only longitudinal traction externally are less effective [3]. The multi-loop traction device (MLTD; Boston Scientific, Marlborough, Massachusetts, United States), which enables traction-assisted ESD by anchoring the loop to the lumen of the other side with an endoscopic clip, allows for easy adjustment of traction direction and removal, demonstrating its effectiveness [4]. However, in the wide lumen of the stomach, a single short MLTD would result in excessive traction force and muscle-layer traction. Therefore, we report a safer gastric ESD technique using two connected MLTDs to optimize traction force and prevent excessive muscle-layer traction. In Case 1, a single MLTD (triple loop) ([Fig. 1] a) was used. The lesion (19×16 mm, 0–IIc) was in the lesser curvature of the middle stomach ([Fig. 2]). ESD was performed using a DualKnife J (KD-655L; Olympus, Tokyo, Japan; [Video 1]), and an MLTD was applied after a circumferential incision. Although traction improved submucosal visibility, the muscle layer was also tractioned, making the procedure difficult ([Fig. 3]). In Case 2, two MLTDs connected by a cow-hitch knot were used (six loops) ([Fig. 1] b). The lesion (10×6 mm, 0–IIa) was on the posterior wall of the midbody ([Fig. 4]). After making a full circumferential incision, traction with two MLTDs provided clear submucosal visibility without excessive muscle-layer traction ([Fig. 5]). ESD was safely completed using devices of appropriate length for the wide lumen. Distant anchoring can pull the muscle layer even with two MLTDs; therefore, the best site is slightly mouthward on the contralateral side. For traction-assisted ESD of the stomach, which has an extensive and complex geometry, our findings suggest that setting the appropriate traction-device length and traction force is necessary for improving safety. Received: 29 July 2024 Accepted after revision: 24 October 2024 Article published online: 18 November 2024 © 2024. The Author(s). This is an open access article published by Thieme under the terms of the Creative Commons Attribution-NonDerivative-NonCommercial-License, permitting copying and reproduction so long as the original work is given appropriate credit. Contents may not be used for commercial purposes, or adapted, remixed, transformed or built upon. (https://creativecommons.org/licenses/by-nc-nd/4.0/). Georg Thieme Verlag KG Oswald-Hesse-Straße 50, 70469 Stuttgart, Germany

  • Open Access

    Superficial esophageal squamous cell carcinoma with melanocytosis that was endoscopically difficult to differentiate from malignant melanoma

    by Yoshinori Horikawa, Kenichi Goda, Ryota Koyanagi, Masayuki Kondo, Keiichiro Abe, Akira Kanamori, Koichi Hamada, Kazuyuki Ishida, Atsushi Irisawa

    Esophageal squamous cell carcinoma (SCC) with dark spots caused by melanocytosis is very rare. A reddish and flat lesion, 4 cm in length and covering over two‐thirds of the circumference, was found in the midthoracic esophagus of a 66‐year‐old male. Multiple brown and black spots are observed in the lesion. Superficial SCC with melanocytosis or malignant melanoma was also suspected. Endoscopic submucosal dissection was performed without biopsies of the spots. Histologically, a few melanocytes were observed in the black spots, and the lesion was diagnosed as SCC (T1a‐lamina propria mucosae) with melanocytosis. We report a case of esophageal SCC with dark black spots that were difficult to differentiate endoscopically from malignant melanoma.

  • Histopathologic vertical margin positivity in cold snare polypectomy and mucosal resection for sessile serrated lesions

    by Koichi Hamada, Michitaka Honda, Yoshinori Horikawa, Yoshiki Shiwa, Kae Techigawara, Takayuki Nagahashi, Masafumi Ishikawa, Yuki Takeda, Daizo Fukushima, Noriyuki Nishino, et al.


  • Open Access

    Muscle layer injury during underwater endoscopic mucosal resection for an adenoma on the cecal fold

    by Takayuki Nagahashi, Koichi Hamada, Yoshinori Horikawa, Kae Techigawara, Masafumi Ishikawa, Michitaka Honda, Tamotsu Sugai

    Underwater endoscopic mucosal resection (UEMR) differs from conventional EMR in that it does not require local injection; instead, the colon is filled with water, and the tumor is resected [1]. It is characterized by rates of high en bloc, complete, and R0 resection, with a lower recurrence rate than conventional EMR [2] [3]. There are few reports of perforation or muscle layer injury caused by UEMR [4] [5]. Here, we report a case in which UEMR was performed for an adenoma located on the fold of the cecum, resulting in muscle layer injury ([Video 1]). An 85-year-old man presented with an 18-mm flat lesion (0-IIa) in the cecum ([Fig. 1]). A UEMR technique was applied ([Fig. 2]). The operator did not know that the lesion was on the cecal fold. After resection the inner muscle layer was seen to be injured ([Fig. 3]); however, no damage to the external muscle layer or perforation was observed. The operator then realized that the lesion had been above the fold. The wound was treated with through-the-scope clips, and complete closure was achieved ([Fig. 4]). The patient remained asymptomatic, and computed tomography confirmed the absence of free air. The patient was discharged 2 days after the procedure. The pathological diagnosis was an adenoma with a negative vertical margin. The specimen contained a portion of the muscle layer ([Fig. 5]). Several meta-analyses have shown that UEMR has a risk of perforation and bleeding similar to that of conventional EMR [2] [3]. However, the factors associated with perforations in UEMR are unknown. In reviewing this case, one possible cause of the muscle injury was the lesion’s location above the fold of the cecum. It may be necessary to inflate the bowel with air before the procedure to ensure that there are no folds under the lesion. Endoscopy_UCTN_Code_CPL_1AJ_2AD_3AC Article published online: 18 November 2024 © 2024. The Author(s). This is an open access article published by Thieme under the terms of the Creative Commons Attribution License, permitting unrestricted use, distribution, and reproduction so long as the original work is properly cited. (https://creativecommons.org/licenses/by/4.0/). Georg Thieme Verlag KG Oswald-Hesse-Straße 50, 70469 Stuttgart, Germany

  • Open Access

    Mucosal flap creation in colorectal endoscopic submucosal dissection using a V-shaped incision

    by Koichi Hamada, Yoshinori Horikawa, Kae Techigawara, Takayuki Nagahashi, Masafumi Ishikawa, Michitaka Honda, Tamotsu Sugai

    The creation of a flap at the beginning of colorectal endoscopic submucosal dissection (ESD) of lesions on the semilunar fold or in the cecum is challenging because the knife is at right angles to the muscle layer. Thus, several innovations in flap creation have been reported [1] [2]. The usefulness of traction-assisted ESD has been reported, including the clip-with-line [3] and the S-O clip [4] methods, which require a clip to be attached to the flap. Underwater ESD has also been reported to be helpful [5]; however, it first requires the creation of a flap. The advantage of being able to create a flap safely and quickly, even in areas that are difficult to treat, is significant. Here, we report the successful creation of a mucosal flap using a V-shaped incision. A 70-year-old man presented with a 38-mm type 0-IIa colonic adenocarcinoma of the cecum ([Fig. 1]). ESD was performed using a DualKnife J (KD-655Q; Olympus, Tokyo, Japan) ([Video 1]). The lesion was located where the knife encounters the muscle layer, and we anticipated that it would be challenging to create a flap and insert a hood between the mucosa and muscle layers. Furthermore, when the colon is dilated by insufflation, it is difficult for the endoscope to reach the lesion, and it is necessary to deflate in order to approach the lesion. After local injection of fluid into the submucosa, a V-shaped flap was created by means of a V-shaped incision ([Fig. 2]). The sharp angle of the V was on the anorectal side, where it is easier to enter. The V-shaped incision created a narrow flap that allowed insertion of the hood under the mucosa after only two dissection attempts ([Fig. 3]). Once the hood has been inserted, ESD can be performed safely using underwater or traction-assisted ESD, as appropriate. In conclusion, we have demonstrated how a V-shaped incision can create a narrow flap for colorectal ESD. Endoscopy_UCTN_Code_CPL_1AJ_2AD_3AD Article published online: 29 April 2024 © 2024. The Author(s). This is an open access article published by Thieme under the terms of the Creative Commons Attribution License, permitting unrestricted use, distribution, and reproduction so long as the original work is properly cited. (https://creativecommons.org/licenses/by/4.0/). Georg Thieme Verlag KG Rüdigerstraße 14, 70469 Stuttgart, Germany

  • Open Access

    Duodenal endoscopic submucosal dissection with a retracted needle knife

    by Koichi Hamada, Kae Techigawara, Yoshiki Shiwa, Yoshinori Horikawa, Masafumi Ishikawa, Michitaka Honda

    Endoscopic submucosal dissection (ESD) of the duodenum is technically challenging, with a high risk of intraoperative perforation and delayed adverse events [1]. Valuable methods, such as the water pressure [2] and traction-assisted methods [3] have been reported. The DualKnife retracts with 0.1 mm left outside the sheath ([Fig. 1]). This feature is useful for marking and hemostasis [4]. There is a risk of perforation when the submucosal layer is dissected using a knife facing the muscle layer. We report that safe and effective dissection was possible with the retracted DualKnife and traction assistance. A 71-year-old man presented with a 20-mm type 0-IIc duodenal adenocarcinoma in the second portion of the duodenum ([Fig. 2]). ESD was performed using a therapeutic endoscope (GIF-H290T; Olympus, Tokyo, Japan) and 1.5-mm DualKnife J (KD-655L; Olympus) under general anesthesia ([Video 1]). A short, small-caliber-tip transparent hood (DH-28GR; Fujifilm, Tokyo, Japan) was used. Mucosal incision was made using the underwater and conventional methods. Dissection was performed underwater, with the water pressure method as appropriate. After the full-circumference incision and flap were made, traction toward the opposite side was created with a multi-loop traction device (Boston Scientific, Marlborough, Massachusetts, United States). When the knife faced the muscle layer or the scope was unstable, the submucosa was dissected with a retracted knife ([Fig. 3]). The submucosa can be effectively dissected with a light touch of the retracted knife under proper traction. The risk of intraoperative perforation is reduced because the knife does not penetrate the muscle layer. However, there is a risk of muscle layer coagulation if the knife is pressed hard against the submucosa. En bloc resection was achieved without perforation ([Fig. 4]), and the ulcer was closed entirely with clips to prevent delayed perforation. We demonstrated a safe duodenal ESD with a retracted needle knife. Received: 18 January 2023 Accepted after revision: 07 June 2023 Article published online: 01 August 2023 © 2023. The Author(s). This is an open access article published by Thieme under the terms of the Creative Commons Attribution-NonDerivative-NonCommercial-License, permitting copying and reproduction so long as the original work is given appropriate credit. Contents may not be used for commercial purposes, or adapted, remixed, transformed or built upon. (https://creativecommons.org/licenses/by-nc-nd/4.0/). Georg Thieme Verlag KG Rüdigerstraße 14, 70469 Stuttgart, Germany

  • Open Access

    Double-scope endoscopic submucosal dissection of superficial laryngeal cancer to preserve the superior laryngeal nerve

    by Yoshinori Horikawa, Koichi Hamada, Yoshiki Shiwa, Yusuke Mada, Kae Techigawara, Masafumi Ishikawa, Akiyoshi Ishiyama

    Endoscopic submucosal dissection (ESD) is a minimally invasive surgery for laryngeal cancers [1], during which nerve sparing is necessary to preserve function [2]. The internal branch of the superior laryngeal nerve (ibSLN) enters the parietal recess mucosa and is distributed in the submucosa of the larynx and hypopharynx [3]. The ibSLN controls sensory perception. Damage to this may result in loss of the laryngeal cough reflex, resulting in aspiration pneumonia. A previous study reported the efficacy of double-scope ESD (ds-ESD) for laryngeal cancers [4]. We believe that ds-ESD is effective in nerve preservation. Here, we report a case of successful nerve-sparing ESD using the double-scope method. A 72-year-old man presented with a 25 mm type 0-IIa lesion of the right piriform sinus ([Fig. 1 a]), which was surgically treated under general anesthesia ([Video 1]). During treatment, an otolaryngologist elevated the larynx using a curved laryngoscope (Nagashima Medical Instruments Co., Ltd., Tokyo, Japan) to ensure an adequate working space. Chromoendoscopy with 0.75 % Lugol’s solution clearly revealed the lesion ([Fig. 1 b]), and marking dots were placed around the lesion using a DualKnife J (KD-655Q; Olympus, Tokyo, Japan). Cutting and dissection were performed using a transoral endoscope (GIF-H290T; Olympus). A saline solution was injected into the subepithelium. After the mucosa was cut and the subepithelial layer was dissected to a length of ≥ 5 mm for grasping ([Fig. 2]), appropriate traction was performed using a thin transnasal endoscope (GIF-1200N; Olympus) and grasping forceps (FG-4L-1; Olympus). The traction direction was changed by controlling the angle of the thin endoscope. Video 1 Double-scope endoscopic submucosal dissection for superficial laryngeal cancer to preserve the superior laryngeal nerve. Proper traction with ds-ESD allowed visualization of the ibSLN and enabled nerve-sparing ESD ([Fig. 3]). No dysphagia or aspiration pneumonia occurred after ESD. Endoscopy_UCTN_Code_CCL_1AB_2AB Article published online: 26 May 2023 © 2023. The Author(s). This is an open access article published by Thieme under the terms of the Creative Commons Attribution License, permitting unrestricted use, distribution, and reproduction so long as the original work is properly cited. (https://creativecommons.org/licenses/by/4.0/) Georg Thieme Verlag KG Rüdigerstraße 14, 70469 Stuttgart, Germany