FLFlorian Lampert

Florian Lampert

*This is an algorithmically generated author record based on publicly available information.

Florian Lampert has a total of 147 co-authors. Here are the top co-authors by number of shared publications:

  • G. Björn Stark

    Department of Plastic and Hand Surgery, Faculty of Medicine, University of Freiburg, Freiburg, Germany

    10 shared publications
  • Günter Finkenzeller

    Department of Plastic and Hand Surgery, Faculty of Medicine, Medical Center-University of Freiburg, Freiburg, Germany

    8 shared publications
  • Georgios Koulaxouzidis

    Department of Plastic and Hand Surgery, University of Freiburg Medical Center, Freiburg, Germany

    6 shared publications
  • G. B. Stark

    Department of Plastic and Hand Surgery, Faculty of Medicine, University of Freiburg, im Breisgau, Germany

    5 shared publications
  • G.B. Stark

    Department of Plastic and Hand Surgery, Freiburg University Medical Center, Freiburg, Germany

    5 shared publications
  • Horst Zajonc

    Department of Hand and Plastic Surgery, Faculty of Medicine, Medical Center – University of Freiburg, University of Freiburg, Freiburg im Breisgau, Germany

    5 shared publications

Latest Publications

  • Anatomie der Hand

    by Florian Lampert

  • Untersuchung der Hand

    by Florian Lampert

  • Open Access

    Image quality and patient satisfaction in cone-beam and multidetector computed tomography of the wrist: a randomized trial

    by Carolin S. Reidelbach, Claudia Neubauer, Ann-Kristin H. Geissler, Florian Lampert, Horst Zajonc, Filip Simunovic, Fabian Bamberg, Elmar Kotter, Sebastian M. Goerke, Jakob Neubauer

    Background: Musculoskeletal cone-beam computed tomography (CBCT) is an imaging technique for wrist assessment. In this study, we compared image quality and patient satisfaction between CBCT and multidetector computed tomography (MDCT) in traumatic wrist patients in a dose-matched setting. Methods: We prospectively enrolled traumatic patients who were scheduled for CT of the wrist. Patients were randomly assigned to CBCT or MDCT. Radiation dose was kept identical between both modalities. Subsequently, patients were asked to complete a questionnaire regarding the examination. Measurements of contrast-to-noise ratio (CNR) were performed. Three blinded readers independently rated image quality on Likert scales. Results: A total of 125 patients (mean age 35 years [standard deviation 16]; 91 men) were included. A total of 108 patients returned the questionnaire. With equivalent dose, CNRs were higher in CBCT compared to MDCT (p < 0.001) and the median ratings of image quality were better for CBCT compared to MDCT (p ≤ 0.04). Patients only rated positioning in CBCT as more comfortable than in MDCT (p < 0.001), while there were no further differences regarding satisfaction with both modalities. Conclusions: At equivalent dose settings to MDCT, CBCT showed a high image quality for the depiction of bony structures, soft tissue and artifacts in wrist examinations of trauma patients. Overall, patients were equally satisfied with both methods. Altogether, CBCT might be a promising alternative for wrist imaging. However, further studies with more different devices are needed.

  • Arthroscopic Capsulodesis for the Treatment of Dynamic Scapholunate Dissociations

    by Max Haerle, Nicole Schmelzer-Schmied, Florian M. Lampert

    Management of scapholunate dissociations remains a significant challenge. Open approaches suffer from a disadvantageous further impairment of the stabilizing local structures. The minimally invasive arthroscopic technique described provides reliable stability of the scapholunate interosseous ligament complex in dynamic lesions. The anatomic key structure is the dorsal capsuloligamentous scapholunate septum, which provides a mechanical connection between the scaphoid, lunate, and dorsal capsule of the wrist. Arthroscopic capsuloplasty aims to tighten and stabilize this complex structure in long term. This approach preserves the adjacent structures, namely the secondary wrist stabilizers and their neuromuscular feedback loops. With a certain degree of experience in wrist arthroscopy, the technique is reliably adaptable and reproducible.


  • Open Access

    Evaluation of a Novel Thiol–Norbornene-Functionalized Gelatin Hydrogel for Bioprinting of Mesenchymal Stem Cells

    by Vadym Burchak, Fritz Koch, Leonard Siebler, Sonja Haase, Verena K. Horner, Xenia Kempter, G. Björn Stark, Ute Schepers, Alisa Grimm, Stefan Zimmermann, et al.

    Introduction: Three-dimensional bioprinting can be considered as an advancement of the classical tissue engineering concept. For bioprinting, cells have to be dispersed in hydrogels. Recently, a novel semi-synthetic thiolene hydrogel system based on norbornene-functionalized gelatin (GelNB) and thiolated gelatin (GelS) was described that resulted in the photoclick hydrogel GelNB/GelS. In this study, we evaluated the printability and biocompatibility of this hydrogel system towards adipose-tissue-derived mesenchymal stem cells (ASCs). Methods: GelNB/GelS was synthesized with three different crosslinking densities (low, medium and high), resulting in different mechanical properties with moduli of elasticity between 206 Pa and 1383 Pa. These hydrogels were tested for their biocompatibility towards ASCs in terms of their viability, proliferation and differentiation. The extrusion-based bioprinting of ASCs in GelNB/GelS-high was performed to manufacture three-dimensional cubic constructs. Results: All three hydrogels supported the viability, proliferation and chondrogenic differentiation of ASCs to a similar extent. The adipogenic differentiation of ASCs was better supported by the softer hydrogel (GelNB/GelS-low), whereas the osteogenic differentiation was more pronounced in the harder hydrogel (GelNB/GelS-high), indicating that the differentiation fate of ASCs can be influenced via the adaption of the mechanical properties of the GelNB/GelS system. After the ex vivo chondrogenic differentiation and subcutaneous implantation of the bioprinted construct into immunocompromised mice, the production of negatively charged sulfated proteoglycans could be observed with only minimal inflammatory signs in the implanted material. Conclusions: Our results indicate that the GelNB/GelS hydrogels are very well suited for the bioprinting of ASCs and may represent attractive hydrogels for subsequent in vivo tissue engineering applications.


  • Autologous skin micro-grafts and allogenic skin allograft for mitten hand deformity treatment in epidermolysis bullosa

    by Nico Leibig, G. Björn Stark, Horst Zajonc, Marcel Frick, Dimitra Kiritsi, Florian M. Lampert

    Background: In the genetic skin blistering disorder dystrophic epidermolysis bullosa recurrent blisters and erosions on mechanically stressed areas, as the hands, result in subsequent scarring and development of pseudosyndactylies and contractures. In its most severe form, all fingers are constrained into a fist of scarred (“mitten-hand”-deformity). No causative therapy exists and only a surgical release of the fingers is possible. Hereby, the development of large skin defects is inevitable; the lack of healthy autologous skin for grafting remains a difficult challenge.Methods: We propose a new technique: It adopts a treatment strategy from the therapy of large extent burns and consists of a combination of autogenic and allogenic skin grafting.Results: We present a beneficial outcome in 18 mitten hand deformities treated with this technique. In all patients, the initial functional outcome was improved. Nearly all patients got a considerably widened grip span and durable skin conditions post-operatively. Mean follow-up was 3 years. Typically, recurrence of the scarring occurred from 6 months to 2 years after operation.Conclusions: This is the first report on the use of the combination of autogenous pinch skin grafts with allogenic (parental) skin overlay for skin defects in EB. It provides undisturbed wound healing under a “biological dressing”, furthermore, a temporary take of the parental skin was visible. Defects were permanently covered with skin of increased mechanical stability, hand function improved remarkably. However, long term follow-up showed beginning recurrence in most of the patients comparable to recurrence rates described in the literature.

  • Open Access

    In vivo evaluation of bioprinted prevascularized bone tissue

    by Patrick Rukavina, Fritz Koch, Maximilian Wehrle, Kevin Tröndle, G. Björn Stark, Peter Koltay, Stefan Zimmermann, Roland Zengerle, Florian Lampert, Sandra Strassburg, et al.

    Bioprinting can be considered as a progression of the classical tissue engineering approach, in which cells are randomly seeded into scaffolds. Bioprinting offers the advantage that cells can be placed with high spatial fidelity within three‐dimensional tissue constructs. A decisive factor to be addressed for bioprinting approaches of artificial tissues is that almost all tissues of the human body depend on a functioning vascular system for the supply of oxygen and nutrients. In this study, we have generated cuboid pre‐vascularized bone tissue constructs by bioprinting human adipose‐derived mesenchymal stem cells (ASCs) and human umbilical vein endothelial cells (HUVECs) by extrusion‐based bioprinting and drop‐on‐demand (DoD) bioprinting, respectively. The computer‐generated print design could be verified in vitro after printing. After subcutaneous implantation of bioprinted constructs in immunodeficient mice, blood vessel formation with human microvessels of different calibers could be detected arising from bioprinted HUVECs and stabilization of human blood vessels by mouse pericytes was observed. In addition, bioprinted ASCs were able to synthesize a calcified bone matrix as an indicator of ectopic bone formation. These results indicate that the combined bioprinting of ASCs and HUVECs represents a promising strategy to produce pre‐vascularized artificial bone tissue for prospective applications in the treatment of critical‐sized bone defects.


  • Open Access

    Comparing the diagnostic performance of radiation dose-equivalent radiography, multi-detector computed tomography and cone beam computed tomography for finger fractures – A phantom study

    by Carolin Sophie Reidelbach, Sebastian Moritz Goerke, Simon Carl Leschka, Claudia Neubauer, Martin Soschynski, Florian Lampert, Horst Zajonc, Elmar Kotter, Mathias Langer, Jakob Neubauer

    To compare the diagnostic performance and raters´confidence of radiography, radiography equivalent dose multi-detector computed tomography (RED-MDCT) and radiography equivalent dose cone beam computed tomography (RED-CBCT) for finger fractures. Fractures were inflicted artificially and randomly to 10 cadaveric hands of body donors. Radiography as well as RED-MDCT and RED-CBCT imaging were performed at dose settings equivalent to radiography. Images were de-identified and analyzed by three radiologists regarding finger fractures, joint involvement and confidence with their findings. Reference standard was consensus reading by two radiologists of the fracturing protocol and high-dose multi-detector computed tomography (MDCT) images. Sensitivity and specificity were calculated and compared with Cochrane´s Q and post hoc analysis. Rater´s confidence was calculated with Friedman Test and post hoc Nemenyi Test. Rater´s confidence, inter-rater correlation, specificity for fractures and joint involvement were higher in RED-MDCT and RED-CBCT compared to radiography. No differences between the modalities were found regarding sensitivity. In this phantom study, radiography equivalent dose computed tomography (RED-CT) demonstrates a partly higher diagnostic accuracy than radiography. Implementing RED-CT in the diagnostic work-up of finger fractures could improve diagnostics, support correct classification and adequate treatment. Clinical studies should be performed to confirm these preliminary results.


  • The adipofasciocutaneous gluteal fold perforator flap a versatile alternative choice for covering perineal defects

    by G. Koulaxouzidis, V. Penna, H. Bannasch, H. P. Neeff, P. Manegold, F. Aigner, C. Witzel, M. E. Kreis, J. Pratschke, G. B. Stark, et al.

    Perineal defects following the resection of anorectal malignancies are a reconstructive challenge. Flaps based on the rectus abdominis muscle have several drawbacks. Regional perforator flaps may be a suitable alternative. We present our experience of using the gluteal fold flap (GFF) for reconstructing perineal and pelvic defects.


  • Increased differentiation and production of extracellular matrix components of primary human osteoblasts after cocultivation with endothelial cells: A quantitative proteomics approach

    by F. Simunovic, O. Winninger, S. Strassburg, H. G. Koch, G. Finkenzeller, G. B. Stark, F. M. Lampert

    Coculturing of bone‐forming and blood vessel‐forming cells is a strategy aimed at increasing vascularity of implanted bone constructs in tissue‐engineering applications. We previously described that the coculture of primary human osteoblasts (hOBs) and human umbilical vein endothelial cells (HUVECs) improves the differentiation of both cell types, leading to the formation of functional blood vessels and enhanced bone regeneration. The objective of this study was to further delineate the multifaceted interactions between both cell types. To investigate the proteome of hOBs after cocultivation with HUVECs we used stable isotope labeling by amino acids in cell culture, revealing 49 significantly upregulated, and 54 significantly downregulated proteins. Amongst the highest regulated proteins, we found the proteins important for osteoblast differentiation, cellular adhesion, and extracellular matrix function, notably: connective tissue growth factor, desmoplakin, galectin‐3, and cyclin‐dependent kinase 6. The findings were confirmed by enzyme‐linked immunosorbent assays. We also investigated whether the mRNA transcripts correlate with the changes in protein levels by quantitative real‐time reverse transcription polymerase chain reaction. In addition, the data was compared to our previous microarray analysis of hOB transcriptome. Taken together, this in‐depth analysis delivers reliable data suggesting the importance of coculturing of hOBs and HUVECs in tissue engineering.