Aleksey V. Shakurov
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Aleksey V. Shakurov has a total of 87 co-authors. Here are the top co-authors by number of shared publications:
A. V. Pushkarev
Bauman Moscow State Technical University (National Research University), Moscow, Russian Federation
7 shared publications- Andrei S. Skriabin
Bauman Moscow State Technical University
6 shared publications D. I. Tsiganov
Bauman Moscow State Technical University (National Research University), Moscow, Russian Federation
6 shared publicationsA. A. Zherdev
Bauman Moscow State Technical University (National Research University), Moscow, Russian Federation
5 shared publications- Aleksander Vasilevich Pushkarev
Bauman Moscow State Technical University
5 shared publications - Alexander O. Vasilyev
Russian University of Medicine, Ministry of Health of Russia
4 shared publications
Latest Publications
- 13 October 2026
- Published by Elsevier in International Journal of Heat and Mass Transfer
- Vol. 273
Coupled airflow and bioheat transfer modeling of knee cooling during cold air therapy
- 13 October 2026
- Published by Elsevier in International Journal of Heat and Mass Transfer
- Vol. 273
Coupled airflow and bioheat transfer modeling of knee cooling during cold air therapy
- 2 June 2026
- Published by FSBI Research Institute of Occupational Health RAMS in Russian Journal of Occupational Health and Industrial Ecology
- Vol. 66 (4)
Localized low-temperature exposure in medicine: classification, evolution of approaches, and clinical areas of application
Localized low-temperature exposure comprises medical technologies based on controlled heat removal from a limited tissue region and differing in clinical purpose and biological outcome. The aim of this review was to refine the terminology, compare the main directions of localized low-temperature exposure, trace the evolution of approaches, and analyze current clinical fields of application. An analytical review of Russian and international publications indexed in RISC, PubMed/MEDLINE, Scopus, Web of Science, and Google Scholar was performed. The review shows that modern cryomedicine should distinguish three independent directions of localized low-temperature exposure: destruction, preservation, and therapy. These directions share the same thermal basis but differ in their intended biological outcome, acceptable temperature range, cooling depth, exposure duration, and criteria of effectiveness. Current research is focused on standardizing temperature-time protocols, improving navigation and computational support, personalizing cooling, and evaluating clinical outcomes in minimally invasive treatment, transplantation, medical rehabilitation, and restorative medicine. The proposed systematization may serve as a basis for clinically oriented description and further standardization of the cold factor in medicine, including medical rehabilitation, restorative treatment, and conditions associated with limited functional activity.Contributions:Korobova N.Yu. — concept and design of the review, literature search and analysis, systematization of the material, writing of the manuscript;|Makarov A.F. — concept of the review, scientific editing, critical revision of the content;Pushkarev A.V. — literature search and analysis, drafting of selected sections of the manuscript, editing;Shakurov A.V. — literature analysis, participation in data interpretation, editing of the manuscript;Tsiganov D.I. — scientific supervision, critical revision of the manuscript, approval of the final version of the article.Funding. The study was supported by grants from the Russian Science Foundation (RSF), № 24-79-10153, https://rscf.ru/project/24-79-10153/ (section on local low-temperature exposure for therapeutic purposes) and № 24-19-00497, https://rscf.ru/project/24-19-00497/ (sections of local low-temperature exposure for the purpose of destruction and preservation of biological tissues).Conflict of interest. The authors declare no conflict of interest.Received: 29.04.2026 / Accepted: 01.05.2026 / Published: 02.06.2026
- 2 June 2026
- Published by FSBI Research Institute of Occupational Health RAMS in Russian Journal of Occupational Health and Industrial Ecology
- Vol. 66 (4)
Localized low-temperature exposure in medicine: classification, evolution of approaches, and clinical areas of application
Localized low-temperature exposure comprises medical technologies based on controlled heat removal from a limited tissue region and differing in clinical purpose and biological outcome. The aim of this review was to refine the terminology, compare the main directions of localized low-temperature exposure, trace the evolution of approaches, and analyze current clinical fields of application. An analytical review of Russian and international publications indexed in RISC, PubMed/MEDLINE, Scopus, Web of Science, and Google Scholar was performed. The review shows that modern cryomedicine should distinguish three independent directions of localized low-temperature exposure: destruction, preservation, and therapy. These directions share the same thermal basis but differ in their intended biological outcome, acceptable temperature range, cooling depth, exposure duration, and criteria of effectiveness. Current research is focused on standardizing temperature-time protocols, improving navigation and computational support, personalizing cooling, and evaluating clinical outcomes in minimally invasive treatment, transplantation, medical rehabilitation, and restorative medicine. The proposed systematization may serve as a basis for clinically oriented description and further standardization of the cold factor in medicine, including medical rehabilitation, restorative treatment, and conditions associated with limited functional activity.Contributions:Korobova N.Yu. — concept and design of the review, literature search and analysis, systematization of the material, writing of the manuscript;|Makarov A.F. — concept of the review, scientific editing, critical revision of the content;Pushkarev A.V. — literature search and analysis, drafting of selected sections of the manuscript, editing;Shakurov A.V. — literature analysis, participation in data interpretation, editing of the manuscript;Tsiganov D.I. — scientific supervision, critical revision of the manuscript, approval of the final version of the article.Funding. The study was supported by grants from the Russian Science Foundation (RSF), № 24-79-10153, https://rscf.ru/project/24-79-10153/ (section on local low-temperature exposure for therapeutic purposes) and № 24-19-00497, https://rscf.ru/project/24-19-00497/ (sections of local low-temperature exposure for the purpose of destruction and preservation of biological tissues).Conflict of interest. The authors declare no conflict of interest.Received: 29.04.2026 / Accepted: 01.05.2026 / Published: 02.06.2026
- Open Access
- 9 March 2026
- Published by ECO-Vector LLC (Publications) in N.N. Priorov Journal of Traumatology and Orthopedics
- Vol. 33 (2) , 316-324
Effect of antibacterial surface modification of titanium screws on bacterial infection
BACKGROUND: Postoperative infections, including osteomyelitis, remain a cause of numerous complications in traumatology and orthopedics. Despite available preventive strategies, bacterial contamination following implantation of titanium devices into bone defects may result in prolonged treatment, disability, and even mortality. AIM: This study aimed to evaluate the effectiveness of an antibiotic immobilized on an anodized titanium implant surface in suppressing peri-implant bacterial infection. METHODS: A pilot single-center prospective study was conducted (study subjects: sexually mature male Wistar rats weighing 250–300 g and aged 4–6 months). The study was comparative and experimental, with the collection of both quantitative and qualitative data at a single time point. Six titanium screws without surface modification and six screws with surface modification were provided for testing by consecutive sampling. The implantation period was 14 days. The overall study duration was 2 months. A porous anodized coating loaded with gentamicin was prepared on the titanium screw surface. Screws were implanted into the tibia of Wistar rats with simultaneous inoculation of Staphylococcus aureus into the medullary canal. Histological and microcomputed-tomography (CT) analyses were performed to assess treatment efficacy. RESULTS: In the control group, pronounced signs of bacterial bone infection were identified histologically and on CT images, characterized by greater bone rarefaction at the bone–implant interface. Reduced bone density was observed in the contact region between the implant and animal bone, with osteolytic zones predominantly on the implant side facing the proximal fragment. The defect margins were indistinct, and no tight bone–implant contact was detected. With the implemented surface modification of the implants, signs of bone rarefaction were less pronounced. Histological examination revealed newly formed bone tissue, in some cases closely apposed to the implanted screw. The area of newly formed bone was 39,311.4 ± 16,637.3 μm2 in the control group and 25,091.6 ± 16,834.7 μm2 in the experimental group, indicating no significant difference in osteogenesis (p = 0.216 0.05). No significant radiological signs of active inflammation or other pathological reactions at the bone–implant interface were observed in the experimental samples. CONCLUSION: The applied method of implant surface preparation with subsequent gentamicin loading demonstrated effectiveness in suppressing bacterial infection and reducing osteolysis in an in vivo model. The use of antibacterial agents did not exert a significant negative effect on osseointegration and was associated with more rapid maturation of newly formed bone tissue. The study results are useful for assessing future directions and identifying potential approaches to manage postoperative infectious complications.
- 9 March 2026
- Published by ECO-Vector LLC (Publications) in N.N. Priorov Journal of Traumatology and Orthopedics
- Vol. 33 (2) , 316-324
Open AccessEffect of antibacterial surface modification of titanium screws on bacterial infection
BACKGROUND: Postoperative infections, including osteomyelitis, remain a cause of numerous complications in traumatology and orthopedics. Despite available preventive strategies, bacterial contamination following implantation of titanium devices into bone defects may result in prolonged treatment, disability, and even mortality. AIM: This study aimed to evaluate the effectiveness of an antibiotic immobilized on an anodized titanium implant surface in suppressing peri-implant bacterial infection. METHODS: A pilot single-center prospective study was conducted (study subjects: sexually mature male Wistar rats weighing 250–300 g and aged 4–6 months). The study was comparative and experimental, with the collection of both quantitative and qualitative data at a single time point. Six titanium screws without surface modification and six screws with surface modification were provided for testing by consecutive sampling. The implantation period was 14 days. The overall study duration was 2 months. A porous anodized coating loaded with gentamicin was prepared on the titanium screw surface. Screws were implanted into the tibia of Wistar rats with simultaneous inoculation of Staphylococcus aureus into the medullary canal. Histological and microcomputed-tomography (CT) analyses were performed to assess treatment efficacy. RESULTS: In the control group, pronounced signs of bacterial bone infection were identified histologically and on CT images, characterized by greater bone rarefaction at the bone–implant interface. Reduced bone density was observed in the contact region between the implant and animal bone, with osteolytic zones predominantly on the implant side facing the proximal fragment. The defect margins were indistinct, and no tight bone–implant contact was detected. With the implemented surface modification of the implants, signs of bone rarefaction were less pronounced. Histological examination revealed newly formed bone tissue, in some cases closely apposed to the implanted screw. The area of newly formed bone was 39,311.4 ± 16,637.3 μm2 in the control group and 25,091.6 ± 16,834.7 μm2 in the experimental group, indicating no significant difference in osteogenesis (p = 0.216 0.05). No significant radiological signs of active inflammation or other pathological reactions at the bone–implant interface were observed in the experimental samples. CONCLUSION: The applied method of implant surface preparation with subsequent gentamicin loading demonstrated effectiveness in suppressing bacterial infection and reducing osteolysis in an in vivo model. The use of antibacterial agents did not exert a significant negative effect on osseointegration and was associated with more rapid maturation of newly formed bone tissue. The study results are useful for assessing future directions and identifying potential approaches to manage postoperative infectious complications.
- 5 November 2025
- Published by Elsevier in Journal of Thermal Biology
- Vol. 134, 104322
The effect of local cryostimulation on osteogenesis during implantation of xenogenic bone matrix: An experimental study
- 5 November 2025
- Published by Elsevier in Journal of Thermal Biology
- Vol. 134, 104322
The effect of local cryostimulation on osteogenesis during implantation of xenogenic bone matrix: An experimental study
- Open Access
- 30 May 2025
- Published by ECO-Vector LLC in Kazan medical journal
- Vol. 106 (3) , 432-445
Local Cryotherapy in Traumatology and Orthopedics: A Review of Current Approaches and Potential Clinical Use
Local cryotherapy is a treatment method used for injuries, musculoskeletal diseases, connective tissue diseases, and post-surgical rehabilitation. Novel technologies such as non-contact cooling with cold gases, augmented compression, and skin temperature regulation, have improved the effectiveness of cryotherapy and expanded its applications. However, it is still important to improve treatment protocols and determine optimal exposure parameters. Therefore, publications on the use of local cryotherapy in traumatology and orthopedics were reviewed to systematize clinical practice approaches and determine the key principles for the development of the treatment option. This article reviews studies on various local cryotherapy options used to treat musculoskeletal diseases and to rehabilitate patients after joint surgery, sport-related injuries, and bone tissue damage. It describes the mechanisms of action and the factors that influence the treatment effectiveness and safety. Local cryotherapy offers several therapeutic benefits, including reduced inflammation and pain, faster recovery of joint function, and reduced need for analgesics. Although more research is needed to confirm its effectiveness, local cryotherapy shows promise as a treatment for bone tissue healing. Most of the current evidence of effectiveness has been obtained from preclinical studies in animal models. Additional studies are required to confirm the applicability and safety of this treatment option in clinical practice. These studies should aim to optimize treatment parameters and evaluate treatment safety. Further randomized studies in humans are also needed. Local cryotherapy has been shown to effectively treat musculoskeletal diseases and rehabilitate musculoskeletal injuries. However, more research is needed to optimize treatment regimens based on the location of the injury and the area of cooling. Further research is needed to develop personalized, local cryotherapy protocols that consider patient characteristics, therapy goals, and the nature of the disease.
- 30 May 2025
- Published by ECO-Vector LLC in Kazan medical journal
- Vol. 106 (3) , 432-445
Open AccessLocal Cryotherapy in Traumatology and Orthopedics: A Review of Current Approaches and Potential Clinical Use
Local cryotherapy is a treatment method used for injuries, musculoskeletal diseases, connective tissue diseases, and post-surgical rehabilitation. Novel technologies such as non-contact cooling with cold gases, augmented compression, and skin temperature regulation, have improved the effectiveness of cryotherapy and expanded its applications. However, it is still important to improve treatment protocols and determine optimal exposure parameters. Therefore, publications on the use of local cryotherapy in traumatology and orthopedics were reviewed to systematize clinical practice approaches and determine the key principles for the development of the treatment option. This article reviews studies on various local cryotherapy options used to treat musculoskeletal diseases and to rehabilitate patients after joint surgery, sport-related injuries, and bone tissue damage. It describes the mechanisms of action and the factors that influence the treatment effectiveness and safety. Local cryotherapy offers several therapeutic benefits, including reduced inflammation and pain, faster recovery of joint function, and reduced need for analgesics. Although more research is needed to confirm its effectiveness, local cryotherapy shows promise as a treatment for bone tissue healing. Most of the current evidence of effectiveness has been obtained from preclinical studies in animal models. Additional studies are required to confirm the applicability and safety of this treatment option in clinical practice. These studies should aim to optimize treatment parameters and evaluate treatment safety. Further randomized studies in humans are also needed. Local cryotherapy has been shown to effectively treat musculoskeletal diseases and rehabilitate musculoskeletal injuries. However, more research is needed to optimize treatment regimens based on the location of the injury and the area of cooling. Further research is needed to develop personalized, local cryotherapy protocols that consider patient characteristics, therapy goals, and the nature of the disease.
- Open Access
- 15 February 2025
- Published by ECO-Vector LLC (Publications) in N.N. Priorov Journal of Traumatology and Orthopedics
- Vol. 32 (1) , 149-159
Effect of surface modification of titanium mesh on biological behavior in vivo experiments
BACKGROUND: Titanium alloys are widely used in medicine due to their high biocompatibility, corrosion resistance and mechanical strength. However, standard titanium implants have a limited ability to integrate with bone tissue, which can lead to various complications and the need for revision operations. Modification of the implant surface with various biologically active compounds is a promising direction for solving this problem. Among the possible approaches, special attention should be paid to the use of inorganic coatings such as calcium oxides and phosphates, which combine high resistance, corrosion resistance and good mechanical properties. AIM: Determining the modification effect of the titanium (Grade 2) mesh surface on the biocompatibility and osseogenic properties of materials with in vivo experiments using the small laboratory animals. MATERIALS AND METHODS: The titanium mesh surface was modified by microarc oxidation in electrolyte with dispersed hydroxyapatite (HAp). The effectiveness of the surface modification was in vivo tested with a trepanation model in the skull of Wistar rats. RESULTS: The formation of a structured regenerate at the bone surface without a significant defect reduction was revealed. The tissue reaction to the implantation of metal meshes in the defect of the parietal bones of the skull was weak, relatively mature dense connective tissue capsules were formed around the meshes, in which vascularization and inflammatory infiltration were minimal, bone regeneration was observed along the defect edges. Surface modification with microarc oxidation led to more pronounced bone regeneration compared to a surface-unmodified mesh. CONCLUSION: Modification of the surface of the titanium-based mesh by micro-arc oxidation in the electrolyte with dispersed HAp has a positive effect on bone regeneration when closing defects of flat bones.
- 15 February 2025
- Published by ECO-Vector LLC (Publications) in N.N. Priorov Journal of Traumatology and Orthopedics
- Vol. 32 (1) , 149-159
Open AccessEffect of surface modification of titanium mesh on biological behavior in vivo experiments
BACKGROUND: Titanium alloys are widely used in medicine due to their high biocompatibility, corrosion resistance and mechanical strength. However, standard titanium implants have a limited ability to integrate with bone tissue, which can lead to various complications and the need for revision operations. Modification of the implant surface with various biologically active compounds is a promising direction for solving this problem. Among the possible approaches, special attention should be paid to the use of inorganic coatings such as calcium oxides and phosphates, which combine high resistance, corrosion resistance and good mechanical properties. AIM: Determining the modification effect of the titanium (Grade 2) mesh surface on the biocompatibility and osseogenic properties of materials with in vivo experiments using the small laboratory animals. MATERIALS AND METHODS: The titanium mesh surface was modified by microarc oxidation in electrolyte with dispersed hydroxyapatite (HAp). The effectiveness of the surface modification was in vivo tested with a trepanation model in the skull of Wistar rats. RESULTS: The formation of a structured regenerate at the bone surface without a significant defect reduction was revealed. The tissue reaction to the implantation of metal meshes in the defect of the parietal bones of the skull was weak, relatively mature dense connective tissue capsules were formed around the meshes, in which vascularization and inflammatory infiltration were minimal, bone regeneration was observed along the defect edges. Surface modification with microarc oxidation led to more pronounced bone regeneration compared to a surface-unmodified mesh. CONCLUSION: Modification of the surface of the titanium-based mesh by micro-arc oxidation in the electrolyte with dispersed HAp has a positive effect on bone regeneration when closing defects of flat bones.
- Open Access
- 25 December 2023
- Published by ECO-Vector LLC in Refrigeration Technology
- Vol. 112 (1) , 49-52
Adjustable partial body cryotherapy
Based on an analysis of the technical level of equipment utilized in cryotherapy, the issue of increasing the dosing accuracy and, accordingly, ensuring accurate and uniform cooling of a biological object was identified, which required research into the issues of controlled cooling. A software for predicting the result of cryotherapy has been developed, and a range of rational parameters for supplying gas to the cabin of the installation has been determined when performing controlled cryotherapy (i.e., from 40 to 70 g/s and from −140℃ to −160℃). An experimental model of a new type of installation, which enables cryotherapy to be conducted with changes in the main parameters of the equipment in operation in a wide range of cooling gas flow temperatures from −50℃ to −160℃, free-flow velocity from 0.1 to 2 m/s, and cryotherapy time up to 420 s, has been developed and implemented. The experimental model, together with the prediction software, forms a complex system for research and controlled implementation of cryotherapy in a wide range of operating parameters. Algorithms for implementing regulated modes for various biological objects and purposes of exposure have been developed and recommendations have been provided, enabling the practical application of the proposed concept.
- 25 December 2023
- Published by ECO-Vector LLC in Refrigeration Technology
- Vol. 112 (1) , 49-52
Open AccessAdjustable partial body cryotherapy
Based on an analysis of the technical level of equipment utilized in cryotherapy, the issue of increasing the dosing accuracy and, accordingly, ensuring accurate and uniform cooling of a biological object was identified, which required research into the issues of controlled cooling. A software for predicting the result of cryotherapy has been developed, and a range of rational parameters for supplying gas to the cabin of the installation has been determined when performing controlled cryotherapy (i.e., from 40 to 70 g/s and from −140℃ to −160℃). An experimental model of a new type of installation, which enables cryotherapy to be conducted with changes in the main parameters of the equipment in operation in a wide range of cooling gas flow temperatures from −50℃ to −160℃, free-flow velocity from 0.1 to 2 m/s, and cryotherapy time up to 420 s, has been developed and implemented. The experimental model, together with the prediction software, forms a complex system for research and controlled implementation of cryotherapy in a wide range of operating parameters. Algorithms for implementing regulated modes for various biological objects and purposes of exposure have been developed and recommendations have been provided, enabling the practical application of the proposed concept.
- 8 August 2023
- Published by Elsevier in International Journal of Refrigeration
- Vol. 155, 105-113
Experimental evaluation of partial body cryotherapy unit with gas supply regulation
- 8 August 2023
- Published by Elsevier in International Journal of Refrigeration
- Vol. 155, 105-113
Experimental evaluation of partial body cryotherapy unit with gas supply regulation
- 1 May 2023
- Published by Springer Nature in Chemical and Petroleum Engineering
- Vol. 59 (1-2) , 126-133
Study of Operating Modes of a Cryogenic Spray Mixing Gasifier with Adjustable Capacity
- 1 May 2023
- Published by Springer Nature in Chemical and Petroleum Engineering
- Vol. 59 (1-2) , 126-133
Study of Operating Modes of a Cryogenic Spray Mixing Gasifier with Adjustable Capacity
- 10 February 2023
- Published by Elsevier in Journal of Thermal Biology
- Vol. 113, 103501
Enhanced bone healing using local cryostimulation: In vivo rat study
- 10 February 2023
- Published by Elsevier in Journal of Thermal Biology
- Vol. 113, 103501
Enhanced bone healing using local cryostimulation: In vivo rat study