Valeria Calvi
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Valeria Calvi has a total of 1000 co-authors. Here are the top co-authors by number of shared publications:
- Corrado Tamburino
Centro Alte Specialità e Trapianti (CAST), Azienda Ospedaliero‐Universitaria Policlinico Vittorio Emanuele, University of Catania
17 shared publications - Davide Capodanno
University of Catania
10 shared publications - Giampiero Maglia
Azienda Ospedaliera Pugliese Ciaccio, Catanzaro, Italy
10 shared publications Alessandro Capucci
Cardiology Department, Ospedali Riuniti, Ancona, Italy
6 shared publicationsAntonio Curnis
Cardiology Division, Spedali Civili, Brescia, Italy
6 shared publicationsEnnio C. Pisanò
Cardiology, Department, Ospedale Vito Fazzi, Lecce, Italy
6 shared publications
Latest Publications
- Open Access
- 2 June 2026
- Published by Wolters Kluwer Health in Circulation
- Vol. 153 (22) , 1707-1718
Role of Atrial Pacing Support in Cardiac Resynchronization Therapy: A Noninferiority Randomized Trial
BACKGROUND: The role of atrial pacing support is unclear in patients receiving cardiac resynchronization therapy–defibrillator (CRT-D) without sinus node dysfunction. METHODS: We conducted a randomized, parallel-group, noninferiority trial to evaluate whether a 2-lead CRT-D capable of atrial sensing (but no pacing) by a floating dipole on the right ventricular lead (CRT-DX) is not inferior to a 3-lead CRT-D with a conventional atrial lead. Between October 17, 2018, and March 5, 2024, a total of 636 patients (68±10 years old, 28.6% women) with standard CRT-D indication, optimized medical therapy, and resting sinus rate ≥45 beats/min were randomized 1:1 to CRT-DX (atrial tracking without atrial pacing mode 35 beats/min) or CRT-D (atrial tracking with atrial pacing mode 50 beats/min) at 23 Italian sites. A centralized block-randomization procedure stratified by site was used, with patients and primary outcome assessors blinded to treatment assignment. The primary end point was a 1-year composite of all-cause mortality, cardiovascular hospitalization, and lead-related complications (loss of functionality not correctable by device reprogramming). Secondary end points included each individual component of the primary end point separately, echocardiographic reverse remodeling, and 6-minute walk test distance at 12 months. RESULTS: The primary end point occurred in 41 (13.1%) patients in the CRT-DX group and 47 (15.6%) patients in the CRT-D group, corresponding to a hazard ratio of 0.82 (95% CI, 0.54–1.25). This confirmed noninferiority (prespecified relative margin of 1.20) in both the per-protocol ( P =0.039) and intention-to-treat ( P =0.044) analyses. Individual components showed no significant differences, except for lead complications related to right atrial functionality (4 [1.3%] patients in the CRT-DX group versus 13 [4.2%] patients in the CRT-D group; P =0.040). Reverse remodeling responders were 203 (77.5% of 262) patients receiving CRT-DX and 190 (76.3% of 249) patients receiving CRT-D ( P =0.83). Walking distance did not differ between 2 study arms (404 versus 398 m; P =0.62). After a median follow-up of 2.4 years, only 1 patient receiving CRT-DX required implantation of a standard atrial lead. CONCLUSIONS: The 2-lead CRT-DX system without atrial pacing is noninferior to conventional 3-lead CRT-D, with fewer atrial lead–related complications. REGISTRATION: URL: https://www.clinicaltrials.gov ; Unique identifier: NCT03587064.
- 2 June 2026
- Published by Wolters Kluwer Health in Circulation
- Vol. 153 (22) , 1707-1718
Open AccessRole of Atrial Pacing Support in Cardiac Resynchronization Therapy: A Noninferiority Randomized Trial
BACKGROUND: The role of atrial pacing support is unclear in patients receiving cardiac resynchronization therapy–defibrillator (CRT-D) without sinus node dysfunction. METHODS: We conducted a randomized, parallel-group, noninferiority trial to evaluate whether a 2-lead CRT-D capable of atrial sensing (but no pacing) by a floating dipole on the right ventricular lead (CRT-DX) is not inferior to a 3-lead CRT-D with a conventional atrial lead. Between October 17, 2018, and March 5, 2024, a total of 636 patients (68±10 years old, 28.6% women) with standard CRT-D indication, optimized medical therapy, and resting sinus rate ≥45 beats/min were randomized 1:1 to CRT-DX (atrial tracking without atrial pacing mode 35 beats/min) or CRT-D (atrial tracking with atrial pacing mode 50 beats/min) at 23 Italian sites. A centralized block-randomization procedure stratified by site was used, with patients and primary outcome assessors blinded to treatment assignment. The primary end point was a 1-year composite of all-cause mortality, cardiovascular hospitalization, and lead-related complications (loss of functionality not correctable by device reprogramming). Secondary end points included each individual component of the primary end point separately, echocardiographic reverse remodeling, and 6-minute walk test distance at 12 months. RESULTS: The primary end point occurred in 41 (13.1%) patients in the CRT-DX group and 47 (15.6%) patients in the CRT-D group, corresponding to a hazard ratio of 0.82 (95% CI, 0.54–1.25). This confirmed noninferiority (prespecified relative margin of 1.20) in both the per-protocol ( P =0.039) and intention-to-treat ( P =0.044) analyses. Individual components showed no significant differences, except for lead complications related to right atrial functionality (4 [1.3%] patients in the CRT-DX group versus 13 [4.2%] patients in the CRT-D group; P =0.040). Reverse remodeling responders were 203 (77.5% of 262) patients receiving CRT-DX and 190 (76.3% of 249) patients receiving CRT-D ( P =0.83). Walking distance did not differ between 2 study arms (404 versus 398 m; P =0.62). After a median follow-up of 2.4 years, only 1 patient receiving CRT-DX required implantation of a standard atrial lead. CONCLUSIONS: The 2-lead CRT-DX system without atrial pacing is noninferior to conventional 3-lead CRT-D, with fewer atrial lead–related complications. REGISTRATION: URL: https://www.clinicaltrials.gov ; Unique identifier: NCT03587064.
- Open Access
- 4 September 2025
- Published by Springer Nature in Heart Failure Reviews
- Vol. 30 (6) , 1361-1370
Cardiac resynchronization therapy in cancer patients with chemotherapy-induced cardiomyopathy: a mini review
Chemotherapy-induced cardiomyopathy (CHIC) represents a growing clinical challenge due to the increasing use of cardiotoxic treatments. These therapies can lead to progressive myocardial dysfunction, ultimately resulting in heart failure. Cardiac resynchronization therapy (CRT) has been widely investigated in selected patients with chronic heart failure; however, those with CHIC remain underrepresented in CRT trials. Current evidence is largely based on retrospective and observational studies, with MADIT-CHIC being the only prospective trial to date. No randomized controlled trials are currently available. Despite encouraging findings, existing data remain limited by small sample sizes and short follow-up durations. In particular, the impact of CRT on left ventricular dyssynchrony, arrhythmic burden, and long-term survival in this population has not been fully elucidated. A multidisciplinary cardio-oncology approach is essential not only for the comprehensive management of these complex patients, but also to guide appropriate timing of CRT implantation. Further research is warranted to refine patient selection criteria and to fully assess the long-term benefits and risks of CRT in patients with CHIC.
- 4 September 2025
- Published by Springer Nature in Heart Failure Reviews
- Vol. 30 (6) , 1361-1370
Open AccessCardiac resynchronization therapy in cancer patients with chemotherapy-induced cardiomyopathy: a mini review
Chemotherapy-induced cardiomyopathy (CHIC) represents a growing clinical challenge due to the increasing use of cardiotoxic treatments. These therapies can lead to progressive myocardial dysfunction, ultimately resulting in heart failure. Cardiac resynchronization therapy (CRT) has been widely investigated in selected patients with chronic heart failure; however, those with CHIC remain underrepresented in CRT trials. Current evidence is largely based on retrospective and observational studies, with MADIT-CHIC being the only prospective trial to date. No randomized controlled trials are currently available. Despite encouraging findings, existing data remain limited by small sample sizes and short follow-up durations. In particular, the impact of CRT on left ventricular dyssynchrony, arrhythmic burden, and long-term survival in this population has not been fully elucidated. A multidisciplinary cardio-oncology approach is essential not only for the comprehensive management of these complex patients, but also to guide appropriate timing of CRT implantation. Further research is warranted to refine patient selection criteria and to fully assess the long-term benefits and risks of CRT in patients with CHIC.
- 1 March 2025
- Published by Wolters Kluwer Health in Circulation: Arrhythmia and Electrophysiology
- Vol. 18 (3) , e013365
Subcutaneous Implantable Defibrillators in Young Patients: Arrhythmias, Complications, and Physical Activity
BACKGROUND: The safety of subcutaneous implantable cardioverter defibrillator (S-ICD) recipients who lead active lifestyles and engage in recreational sports is unknown. We aimed to evaluate the association between lifestyle and recreational sports and the occurrence of arrhythmia- and device-related complications, appropriate and inappropriate shocks in S-ICD recipients. METHODS: We assessed a cohort of young-adult (15–65 years) S-ICD patients, evaluated their physical activity with IPAQ (International Physical Activity Questionnaire), and assessed the association between lifestyle and recreational sports on S-ICD safety and shocks. RESULTS: We enrolled 602 S-ICD recipients (77% men; age, 46±14 years). According to the IPAQ, patients were categorized as inactive subjects (26.4%), moderately active subjects (45.2%), or highly active subjects (28.4%). Among moderately/highly active subjects, 163 (27.1%) were recreational athletes. During follow-up (47.3 [interquartile range, 27.0–67.6] months), 23 patients (3.8%) reached the safety end point of arrhythmia- or device-related complications, with moderately and highly active subjects showing in multivariate analysis similar incidence compared with inactive subjects ( P =0.59 and P =0.83, respectively). Forty-four patients had 87 appropriate shocks. In multivariate analysis, moderately and highly active subjects showed a nonsignificantly lower incidence of appropriate shocks compared with inactive subjects ( P =0.12 and P =0.11, respectively). Consistently, there was a nonsignificant lower incidence of appropriate shocks in athletes versus nonathletes ( P =0.06). Thirty-nine patients had 46 inappropriate shocks. Moderately and highly active subjects had similar incidence of inappropriate shocks compared with inactive subjects ( P =0.92 and P =0.88, respectively). CONCLUSIONS: Young S-ICD patients often lead active lifestyles and participate in sports. Higher activity levels were not associated with increased implantable cardioverter defibrillator–related complications or increased risk of implantable cardioverter defibrillator shocks.
- 1 March 2025
- Published by Wolters Kluwer Health in Circulation: Arrhythmia and Electrophysiology
- Vol. 18 (3) , e013365
Subcutaneous Implantable Defibrillators in Young Patients: Arrhythmias, Complications, and Physical Activity
BACKGROUND: The safety of subcutaneous implantable cardioverter defibrillator (S-ICD) recipients who lead active lifestyles and engage in recreational sports is unknown. We aimed to evaluate the association between lifestyle and recreational sports and the occurrence of arrhythmia- and device-related complications, appropriate and inappropriate shocks in S-ICD recipients. METHODS: We assessed a cohort of young-adult (15–65 years) S-ICD patients, evaluated their physical activity with IPAQ (International Physical Activity Questionnaire), and assessed the association between lifestyle and recreational sports on S-ICD safety and shocks. RESULTS: We enrolled 602 S-ICD recipients (77% men; age, 46±14 years). According to the IPAQ, patients were categorized as inactive subjects (26.4%), moderately active subjects (45.2%), or highly active subjects (28.4%). Among moderately/highly active subjects, 163 (27.1%) were recreational athletes. During follow-up (47.3 [interquartile range, 27.0–67.6] months), 23 patients (3.8%) reached the safety end point of arrhythmia- or device-related complications, with moderately and highly active subjects showing in multivariate analysis similar incidence compared with inactive subjects ( P =0.59 and P =0.83, respectively). Forty-four patients had 87 appropriate shocks. In multivariate analysis, moderately and highly active subjects showed a nonsignificantly lower incidence of appropriate shocks compared with inactive subjects ( P =0.12 and P =0.11, respectively). Consistently, there was a nonsignificant lower incidence of appropriate shocks in athletes versus nonathletes ( P =0.06). Thirty-nine patients had 46 inappropriate shocks. Moderately and highly active subjects had similar incidence of inappropriate shocks compared with inactive subjects ( P =0.92 and P =0.88, respectively). CONCLUSIONS: Young S-ICD patients often lead active lifestyles and participate in sports. Higher activity levels were not associated with increased implantable cardioverter defibrillator–related complications or increased risk of implantable cardioverter defibrillator shocks.
- Open Access
- 24 March 2022
- Published by MDPI AG in Journal of Cardiovascular Development and Disease
- Vol. 9 (4) , 94
Pulsed Field Ablation to Treat Atrial Fibrillation: A Review of the Literature
Atrial fibrillation (AF) is the most common sustained cardiac arrhythmia and catheter ablation, which can be used in symptomatic patients refractory to antiarrhythmic therapy. Pulmonary vein isolation (PVI) remains the cornerstone of any ablation procedure. A major limitation of current catheter ablation procedures is important to recognize because even when the PVI is performed in highly experienced centers, PVI reconnection was documented in about 20% of patients. Therefore, better technology is needed to improve ablation lesions. One of the novelties in recent years is pulsed filed ablation (PFA), a non-thermal energy that uses trains of high-voltage, very-short-duration pulses to kill the cells. The mechanism of action of this energy consists of creating pores in the myocardiocyte cell membrane in a highly selective and tissue-specific way; this leads to death of the target cells reducing the risk of damage to surrounding non-cardiac tissues. In particular during the animal studies, PVI and atrial lines were performed effectively without PV stenosis. Using PFA directly on coronary arteries, there was no luminal narrowing, there has been no evidence of incidental phrenic nerve injury, and finally, PFA has been shown not to injure esophageal tissue when directly applied to the esophagus or indirectly through ablation in the left atrium. The aim of this review is to report all published animal and clinical studies regarding this new technology to treat paroxysmal and persistent AF.
- 24 March 2022
- Published by MDPI AG in Journal of Cardiovascular Development and Disease
- Vol. 9 (4) , 94
Open AccessPulsed Field Ablation to Treat Atrial Fibrillation: A Review of the Literature
Atrial fibrillation (AF) is the most common sustained cardiac arrhythmia and catheter ablation, which can be used in symptomatic patients refractory to antiarrhythmic therapy. Pulmonary vein isolation (PVI) remains the cornerstone of any ablation procedure. A major limitation of current catheter ablation procedures is important to recognize because even when the PVI is performed in highly experienced centers, PVI reconnection was documented in about 20% of patients. Therefore, better technology is needed to improve ablation lesions. One of the novelties in recent years is pulsed filed ablation (PFA), a non-thermal energy that uses trains of high-voltage, very-short-duration pulses to kill the cells. The mechanism of action of this energy consists of creating pores in the myocardiocyte cell membrane in a highly selective and tissue-specific way; this leads to death of the target cells reducing the risk of damage to surrounding non-cardiac tissues. In particular during the animal studies, PVI and atrial lines were performed effectively without PV stenosis. Using PFA directly on coronary arteries, there was no luminal narrowing, there has been no evidence of incidental phrenic nerve injury, and finally, PFA has been shown not to injure esophageal tissue when directly applied to the esophagus or indirectly through ablation in the left atrium. The aim of this review is to report all published animal and clinical studies regarding this new technology to treat paroxysmal and persistent AF.
- Open Access
- 1 February 2021
- Published by Elsevier in IJC Heart & Vasculature
- Vol. 32, 100724
Remote monitoring for heart failure management during COVID-19 pandemic
- 1 February 2021
- Published by Elsevier in IJC Heart & Vasculature
- Vol. 32, 100724
Open AccessRemote monitoring for heart failure management during COVID-19 pandemic
- 18 October 2019
- Published by Oxford University Press (OUP) in EP Europace
- Vol. 21 (12) , 1876-1889
Comparison of outcomes in infected cardiovascular implantable electronic devices between complete, partial, and failed lead removal: an ESC-EHRA-EORP ELECTRa (European Lead Extraction ConTrolled) registry
Aims: The present study sought to determine predictors for success and outcomes of patients who underwent cardiac implantable electronic devices (CIED) extraction indicated for systemic or local CIED related infection in particular where complete lead removal could not be achieved. Methods and results: ESC-EORP ELECTRa (European Lead Extraction ConTRolled Registry) is a European prospective lead extraction registry. Out of the total cohort, 1865/3510 (52.5%) patients underwent removal due to CIED related infection. Predictors and outcomes of failure were analysed. Complete removal was achieved in 1743 (93.5%) patients, partial (4 cm of lead left) in 32 (1.8%) patients. Removal success was unrelated to type of CIED infection (pocket or systemic). Predictors for failure were older leads and older patients [odds ratio (OR) 1.14 (1.08–1.19), P < 0.0001 and OR 2.68 (1.22–5.91), P = 0.0146, respectively]. In analysis by lead, predictors for failure were: pacemaker vs. defibrillator removal and failure to engage the locking stylet all the way to the tip [OR 0.20 (0.04–0.95), P = 0.03 and OR 0.32 (0.13–0.74), P = 0.008, respectively]. Significantly higher complication rates were noted in the failure group (40.6% vs. 15.9 for partial and 8.7% for success groups, P < 0.0001). Failure to remove a lead was a strong predictor for in hospital mortality [hazard ratio of 2.05 (1.01–4.16), P = 0.046]. Conclusion: A total of 6.5% of infected CIED patients failed attempted extraction. Only were >4 cm of lead remained resulted in higher procedural complications and mortality rates.
- 18 October 2019
- Published by Oxford University Press (OUP) in EP Europace
- Vol. 21 (12) , 1876-1889
Comparison of outcomes in infected cardiovascular implantable electronic devices between complete, partial, and failed lead removal: an ESC-EHRA-EORP ELECTRa (European Lead Extraction ConTrolled) registry
Aims: The present study sought to determine predictors for success and outcomes of patients who underwent cardiac implantable electronic devices (CIED) extraction indicated for systemic or local CIED related infection in particular where complete lead removal could not be achieved. Methods and results: ESC-EORP ELECTRa (European Lead Extraction ConTRolled Registry) is a European prospective lead extraction registry. Out of the total cohort, 1865/3510 (52.5%) patients underwent removal due to CIED related infection. Predictors and outcomes of failure were analysed. Complete removal was achieved in 1743 (93.5%) patients, partial (4 cm of lead left) in 32 (1.8%) patients. Removal success was unrelated to type of CIED infection (pocket or systemic). Predictors for failure were older leads and older patients [odds ratio (OR) 1.14 (1.08–1.19), P < 0.0001 and OR 2.68 (1.22–5.91), P = 0.0146, respectively]. In analysis by lead, predictors for failure were: pacemaker vs. defibrillator removal and failure to engage the locking stylet all the way to the tip [OR 0.20 (0.04–0.95), P = 0.03 and OR 0.32 (0.13–0.74), P = 0.008, respectively]. Significantly higher complication rates were noted in the failure group (40.6% vs. 15.9 for partial and 8.7% for success groups, P < 0.0001). Failure to remove a lead was a strong predictor for in hospital mortality [hazard ratio of 2.05 (1.01–4.16), P = 0.046]. Conclusion: A total of 6.5% of infected CIED patients failed attempted extraction. Only were >4 cm of lead remained resulted in higher procedural complications and mortality rates.
- 1 October 2019
- Published by Elsevier in JACC: Clinical Electrophysiology
- Vol. 5 (10) , 1197-1208
Are Atrial High-Rate Episodes Associated With Increased Risk of Ventricular Arrhythmias and Mortality?
- 1 October 2019
- Published by Elsevier in JACC: Clinical Electrophysiology
- Vol. 5 (10) , 1197-1208
Are Atrial High-Rate Episodes Associated With Increased Risk of Ventricular Arrhythmias and Mortality?
- 1 September 2019
- Published by Wolters Kluwer Health in Journal of Cardiovascular Medicine
- Vol. 20 (9) , 597-605
Nationwide survey on the current practice of ventricular tachycardia ablation
Methods: We performed a nationwide survey on the current practice of ventricular tachycardia catheter ablation in Italy during the year 2016. Results: Among 145 operators participating in the survey, 58 (40.0%) did not perform any ventricular tachycardia ablation in 2016. Among those performing ventricular tachycardia ablation, 9 operators (6.2%) performed only right ventricular endocardial catheter ablation, 52 (35.9%) performed endocardial catheter ablation both in the right and left ventricle (LV) and 26 (17.9%) performed both endocardial and epicardial LV catheter ablations. Seventy operators (89.7%) among the 78 performing LV and epicardial ablations treated patients with ischemic cardiomyopathy; ablations in the setting of other causes were less frequently performed. The following were considered as minimum requirements for ventricular tachycardia ablation: presence of a three-dimensional mapping system (120 operators, 82.8%), ICU in the hospital (118 operators, 81.4%), operator's training in high volume centers (93 operators, 64.1%). Twenty-eight operators (19.3%) performed catheter ablation in patients with electrical storm only after hemodynamic stabilization, 41 operators (28.3%) also during the acute phase and 9 operators (6.2%) never performed catheter ablation in electrical storm patients; the remaining 67 operators did not perform ventricular tachycardia ablation at all, or performed ablations only in the right ventricle. Conclusion: The present survey provides a snapshot of the current invasive treatment of ventricular tachycardia by catheter ablation. The procedure, especially in the setting of ischemic cardiomyopathy, is performed nationwide. Complex cases, including those with electrical storm, should be managed within a preestablished integrated network of regional referral centers able to transfer patients as soon as possible.
- 1 September 2019
- Published by Wolters Kluwer Health in Journal of Cardiovascular Medicine
- Vol. 20 (9) , 597-605
Nationwide survey on the current practice of ventricular tachycardia ablation
Methods: We performed a nationwide survey on the current practice of ventricular tachycardia catheter ablation in Italy during the year 2016. Results: Among 145 operators participating in the survey, 58 (40.0%) did not perform any ventricular tachycardia ablation in 2016. Among those performing ventricular tachycardia ablation, 9 operators (6.2%) performed only right ventricular endocardial catheter ablation, 52 (35.9%) performed endocardial catheter ablation both in the right and left ventricle (LV) and 26 (17.9%) performed both endocardial and epicardial LV catheter ablations. Seventy operators (89.7%) among the 78 performing LV and epicardial ablations treated patients with ischemic cardiomyopathy; ablations in the setting of other causes were less frequently performed. The following were considered as minimum requirements for ventricular tachycardia ablation: presence of a three-dimensional mapping system (120 operators, 82.8%), ICU in the hospital (118 operators, 81.4%), operator's training in high volume centers (93 operators, 64.1%). Twenty-eight operators (19.3%) performed catheter ablation in patients with electrical storm only after hemodynamic stabilization, 41 operators (28.3%) also during the acute phase and 9 operators (6.2%) never performed catheter ablation in electrical storm patients; the remaining 67 operators did not perform ventricular tachycardia ablation at all, or performed ablations only in the right ventricle. Conclusion: The present survey provides a snapshot of the current invasive treatment of ventricular tachycardia by catheter ablation. The procedure, especially in the setting of ischemic cardiomyopathy, is performed nationwide. Complex cases, including those with electrical storm, should be managed within a preestablished integrated network of regional referral centers able to transfer patients as soon as possible.
- Open Access
- 7 July 2019
- Published by Wiley in Clinical Cardiology
- Vol. 42 (9) , 820-828
Rate‐responsive pacing and atrial high rate episodes in cardiac resynchronization therapy patients: Is low heart rate the key?
Background: The role of atrial rate‐responsive (RR) pacing in cardiac resynchronization therapy (CRT) is unclear due to the favorable effect of rate lowering in systolic heart failure. Atrial high rate episodes (AHREs) in CRT recipients are particularly worrisome since they cause loss of CRT, beyond representing a stroke risk factor.Hypothesis: The presence of an association between RR and the incidence of AHREs.Methods: Daily remote transmissions from 836 CRT recipients were analyzed. AHREs were classified by duration: ≥15 minutes, ≥5 hours, and ≥ 24 hours. Variables possibly associated to AHREs were included in time‐dependent proportional‐hazard models, averaging over 30‐day periods and adjusting for main baseline variables.Results: After a median follow‐up of 23.9 (12.2‐36.0) months, 507 (60.6%) patients experienced at least one 15‐minute AHRE. RR function was programmed in 166 (19.8%) patients and was associated with an increased AHRE occurrence rate with hazard ratio (HR) ranging from 1.45 to 1.78 for the 3 cutoffs of episode duration. The negative effect of RR function was not observed in the subset of patients with low mean heart rate (P = .01), while CRT amount decreased it (HR:0.98, P < .01). The extent of atrial pacing did not predict AHRE occurrence.Conclusions: RR pacing in CRT recipients is associated with increased AHRE occurrence, especially when an average heart rate > 68 bpm is attained.
- 7 July 2019
- Published by Wiley in Clinical Cardiology
- Vol. 42 (9) , 820-828
Open AccessRate‐responsive pacing and atrial high rate episodes in cardiac resynchronization therapy patients: Is low heart rate the key?
Background: The role of atrial rate‐responsive (RR) pacing in cardiac resynchronization therapy (CRT) is unclear due to the favorable effect of rate lowering in systolic heart failure. Atrial high rate episodes (AHREs) in CRT recipients are particularly worrisome since they cause loss of CRT, beyond representing a stroke risk factor.Hypothesis: The presence of an association between RR and the incidence of AHREs.Methods: Daily remote transmissions from 836 CRT recipients were analyzed. AHREs were classified by duration: ≥15 minutes, ≥5 hours, and ≥ 24 hours. Variables possibly associated to AHREs were included in time‐dependent proportional‐hazard models, averaging over 30‐day periods and adjusting for main baseline variables.Results: After a median follow‐up of 23.9 (12.2‐36.0) months, 507 (60.6%) patients experienced at least one 15‐minute AHRE. RR function was programmed in 166 (19.8%) patients and was associated with an increased AHRE occurrence rate with hazard ratio (HR) ranging from 1.45 to 1.78 for the 3 cutoffs of episode duration. The negative effect of RR function was not observed in the subset of patients with low mean heart rate (P = .01), while CRT amount decreased it (HR:0.98, P < .01). The extent of atrial pacing did not predict AHRE occurrence.Conclusions: RR pacing in CRT recipients is associated with increased AHRE occurrence, especially when an average heart rate > 68 bpm is attained.
- 4 June 2019
- Published by Wiley in Journal of Cardiovascular Electrophysiology
- Vol. 30 (9) , 1626-1635
Long‐term outcomes after prophylactic ICD and CRT‐D implantation in nonischemic patients: Analysis from a nationwide database of daily remote‐monitoring transmissions
Introduction: Clinical trials did not provide conclusive evidence concerning the benefit of prophylactic implantable cardioverter‐defibrillators (ICDs) in patients with severe nonischemic cardiomyopathy (NICM). We aimed to compare incidence of appropriate sustained ventricular arrhythmia (SVA) and device therapy in ischemic cardiomyopathy (ICM) vs NICM ICD and/or cardiac resynchronization therapy (CRT‐D) patients.Methods and Results: We analyzed remote‐monitoring data from devices of the Home Monitoring Expert Alliance network. SVA recordings were adjudicated by three independent electrophysiologists. Our cohort included 1,946 patients who received either an ICD (55%) or a CRT‐D (45%) for primary prevention of sudden cardiac death. Median (interquartile range) age was 70 (62‐77) years, 81% were male, and 52% were in the ICM group. Patients were remotely monitored for a maximum follow‐up of 5 years. The 5‐year product‐limit estimate of SVA incidence in patients with an ICD was 47.3% (95% confidence interval [CI], 41.0%‐53.9%) in the ICM group and 44.7% (36.9%‐53.3%) in the NICM group. In patients with a CRT‐D, SVA incidence was 45.7% (37.3%‐55.0%) in ICM patients and 49.2% (40.4%‐58.7%) in NICM patients. The adjusted hazard ratio for SVA in the ICM vs NICM group was 0.96 (95% CI: 0.70‐1.30, P = .77) in ICD patients and 0.85 (95% CI: 0.61‐1.18, P = .34) in CRT‐D patients. SVAs triggered appropriate device therapies with similar incidence in all groups.Conclusion: In a large cohort of remotely monitored ICD and CRT‐D recipients, SVA incidence did not significantly differ in ICM and NICM patients.
- 4 June 2019
- Published by Wiley in Journal of Cardiovascular Electrophysiology
- Vol. 30 (9) , 1626-1635
Long‐term outcomes after prophylactic ICD and CRT‐D implantation in nonischemic patients: Analysis from a nationwide database of daily remote‐monitoring transmissions
Introduction: Clinical trials did not provide conclusive evidence concerning the benefit of prophylactic implantable cardioverter‐defibrillators (ICDs) in patients with severe nonischemic cardiomyopathy (NICM). We aimed to compare incidence of appropriate sustained ventricular arrhythmia (SVA) and device therapy in ischemic cardiomyopathy (ICM) vs NICM ICD and/or cardiac resynchronization therapy (CRT‐D) patients.Methods and Results: We analyzed remote‐monitoring data from devices of the Home Monitoring Expert Alliance network. SVA recordings were adjudicated by three independent electrophysiologists. Our cohort included 1,946 patients who received either an ICD (55%) or a CRT‐D (45%) for primary prevention of sudden cardiac death. Median (interquartile range) age was 70 (62‐77) years, 81% were male, and 52% were in the ICM group. Patients were remotely monitored for a maximum follow‐up of 5 years. The 5‐year product‐limit estimate of SVA incidence in patients with an ICD was 47.3% (95% confidence interval [CI], 41.0%‐53.9%) in the ICM group and 44.7% (36.9%‐53.3%) in the NICM group. In patients with a CRT‐D, SVA incidence was 45.7% (37.3%‐55.0%) in ICM patients and 49.2% (40.4%‐58.7%) in NICM patients. The adjusted hazard ratio for SVA in the ICM vs NICM group was 0.96 (95% CI: 0.70‐1.30, P = .77) in ICD patients and 0.85 (95% CI: 0.61‐1.18, P = .34) in CRT‐D patients. SVAs triggered appropriate device therapies with similar incidence in all groups.Conclusion: In a large cohort of remotely monitored ICD and CRT‐D recipients, SVA incidence did not significantly differ in ICM and NICM patients.