Bryan P. Rasmussen
Research Subjects
Research Interests
Bryan P. Rasmussen has a total of 57 co-authors. Here are the top co-authors by number of shared publications:
- Austin P. Rogers
Buildings & Connected Systems, Pacific Northwest National Laboratory, Richland, WA, USA
8 shared publications - Christopher J. Bay
National Renewable Energy Laboratory, 15013 Denver West Parkway, Golden, CO 80401, USA
8 shared publications Andrew Alleyne
University of Illinois Urbana-Champaign
6 shared publicationsMatthew S. Elliott
6 shared publicationsAndrew G. Alleyne
University of Illinois at Urbana-Champaign, Urbana, IL, USA
5 shared publications- Fangzhou Guo
Mechanical Engineering, Texas A&M University, College Station, TX, USA
4 shared publications
Latest Publications
- 21 August 2025
- Published by American Society for Engineering Education
Comparison of Video Content for Clarity, Usefulness, and Relevance
- 21 August 2025
- Published by American Society for Engineering Education
Comparison of Video Content for Clarity, Usefulness, and Relevance
- Open Access
- 1 February 2024
- Published by Office of Scientific and Technical Information (OSTI)
Industrial Assessment Center Program Final Progress Report
- 1 February 2024
- Published by Office of Scientific and Technical Information (OSTI)
Open AccessIndustrial Assessment Center Program Final Progress Report
- 10 February 2023
- Published by Elsevier in Applied Thermal Engineering
- Vol. 225
Performance benchmarking of residential air conditioning systems using smart thermostat data
- 10 February 2023
- Published by Elsevier in Applied Thermal Engineering
- Vol. 225
Performance benchmarking of residential air conditioning systems using smart thermostat data
- Open Access
Cascaded Control for Building HVAC Systems in Practice
Actuator hunting is a widespread and often neglected problem in the HVAC field. Hunting is typically characterized by sustained or intermittent oscillations, and can result in decreased efficiency, increased actuator wear, and poor setpoint tracking. Cascaded control loops have been shown to effectively linearize system dynamics and reduce the prevalence of hunting. This paper details the implementation of cascaded control architectures for Air Handling Unit chilled water valves at three university campus buildings. A framework for implementation the control in existing Building Automation software is developed that requires only a single line of additional code. Results gathered for more than a year show that cascaded control not only eliminates hunting in control loops with documented hunting issues, but provides better tracking and more consistent performance during all seasons. A discussion of efficiency losses due to hunting behavior is presented and illustrated with comparative data. Furthermore, an analysis of cost savings from implementing cascaded chilled water valve control is presented. Field tests show 2.2–4.4% energy savings, with additional potential savings from reduced operational costs (i.e., maintenance and controller retuning).
Open AccessCascaded Control for Building HVAC Systems in Practice
Actuator hunting is a widespread and often neglected problem in the HVAC field. Hunting is typically characterized by sustained or intermittent oscillations, and can result in decreased efficiency, increased actuator wear, and poor setpoint tracking. Cascaded control loops have been shown to effectively linearize system dynamics and reduce the prevalence of hunting. This paper details the implementation of cascaded control architectures for Air Handling Unit chilled water valves at three university campus buildings. A framework for implementation the control in existing Building Automation software is developed that requires only a single line of additional code. Results gathered for more than a year show that cascaded control not only eliminates hunting in control loops with documented hunting issues, but provides better tracking and more consistent performance during all seasons. A discussion of efficiency losses due to hunting behavior is presented and illustrated with comparative data. Furthermore, an analysis of cost savings from implementing cascaded chilled water valve control is presented. Field tests show 2.2–4.4% energy savings, with additional potential savings from reduced operational costs (i.e., maintenance and controller retuning).
- 23 December 2021
- Published by Taylor & Francis in Science and Technology for the Built Environment
- Vol. 28 (2) , 121-136
Multivariate fault detection for residential HVAC systems using cloud-based thermostat data, part II: Case studies
Fault detection and diagnosis (FDD) using smart thermostat data is a relatively new field of research, but one with immediate practical application to residential indoor climate control. In this two-part report, a statistics-based FDD method is proposed to identify anomalous residential air conditioning systems using aggregated thermostat data. The proposed method extracts features that characterize system operational behaviors, and determines outliers by comparing the features between thousands of systems. Those outliers are subsequently classified into several categories of anomalous operational behaviors, such as near-continuous operation, poor control, and so on, which are closely related to soft mechanical faults. While the first part of the report details the methodology, this second part provides five case studies to demonstrate the effectiveness of the proposed method. Although these cases should not be considered a complete representation of all kinds of anomalous behaviors, the examples illustrate typical problems, including performance degradation faults with or without affecting occupant comfort, control problems with slight degradation, and oversized systems. Each case study exemplifies one type of behavior that is common among a group of systems, rather than a single outlier that behaves much differently from all others. The case studies illustrate how the proposed fault detection and diagnosis method is capable of identifying malfunctioning systems from a population of residential air conditioning systems.
- 23 December 2021
- Published by Taylor & Francis in Science and Technology for the Built Environment
- Vol. 28 (2) , 121-136
Multivariate fault detection for residential HVAC systems using cloud-based thermostat data, part II: Case studies
Fault detection and diagnosis (FDD) using smart thermostat data is a relatively new field of research, but one with immediate practical application to residential indoor climate control. In this two-part report, a statistics-based FDD method is proposed to identify anomalous residential air conditioning systems using aggregated thermostat data. The proposed method extracts features that characterize system operational behaviors, and determines outliers by comparing the features between thousands of systems. Those outliers are subsequently classified into several categories of anomalous operational behaviors, such as near-continuous operation, poor control, and so on, which are closely related to soft mechanical faults. While the first part of the report details the methodology, this second part provides five case studies to demonstrate the effectiveness of the proposed method. Although these cases should not be considered a complete representation of all kinds of anomalous behaviors, the examples illustrate typical problems, including performance degradation faults with or without affecting occupant comfort, control problems with slight degradation, and oversized systems. Each case study exemplifies one type of behavior that is common among a group of systems, rather than a single outlier that behaves much differently from all others. The case studies illustrate how the proposed fault detection and diagnosis method is capable of identifying malfunctioning systems from a population of residential air conditioning systems.
- 8 December 2021
- Published by Taylor & Francis in Science and Technology for the Built Environment
- Vol. 28 (2) , 109-120
Multivariate fault detection for residential HVAC systems using cloud-based thermostat data, part I: Methodology
Fault detection and diagnosis (FDD) using smart thermostat data is a relatively new field of research, but one with immediate practical application to residential indoor climate control. This two-part article proposes a statistics-based method for using aggregated data from many residential HVAC systems to identify outliers. These outlier systems can then be related to operational problems, such as inadequate capacity, malfunctioning control strategies, or other soft faults. The first part of the article presents the analytical methodology. For this study, historical and real-time data from thousands of cloud-based thermostats are used to extract features during the cooling mode of operation. First, the data are parsed to identify time segments that are characteristic periods of pseudo-steady-state operation. Then, a multistage fault detection method compares the features among all systems to find statistical outliers. Each feature is analyzed independently using kernel density estimation (KDE) methods. Additionally, multiple features are analyzed simultaneously using multivariate statistics and the Mahalanobis distance ( ) to determine outliers. Anomalous systems are sorted heuristically, and information from univariate and multivariate methods is combined to more precisely classify systems exhibiting specific faulty behavior. The second part of this article provides some typical case studies, illustrating how this method can be used to identify aberrant behavior across a large number of monitored systems.- 8 December 2021
- Published by Taylor & Francis in Science and Technology for the Built Environment
- Vol. 28 (2) , 109-120
Multivariate fault detection for residential HVAC systems using cloud-based thermostat data, part I: Methodology
Fault detection and diagnosis (FDD) using smart thermostat data is a relatively new field of research, but one with immediate practical application to residential indoor climate control. This two-part article proposes a statistics-based method for using aggregated data from many residential HVAC systems to identify outliers. These outlier systems can then be related to operational problems, such as inadequate capacity, malfunctioning control strategies, or other soft faults. The first part of the article presents the analytical methodology. For this study, historical and real-time data from thousands of cloud-based thermostats are used to extract features during the cooling mode of operation. First, the data are parsed to identify time segments that are characteristic periods of pseudo-steady-state operation. Then, a multistage fault detection method compares the features among all systems to find statistical outliers. Each feature is analyzed independently using kernel density estimation (KDE) methods. Additionally, multiple features are analyzed simultaneously using multivariate statistics and the Mahalanobis distance ( ) to determine outliers. Anomalous systems are sorted heuristically, and information from univariate and multivariate methods is combined to more precisely classify systems exhibiting specific faulty behavior. The second part of this article provides some typical case studies, illustrating how this method can be used to identify aberrant behavior across a large number of monitored systems.- 28 May 2021
- Published by ASME International in ASCE-ASME Journal of Risk and Uncertainty in Engineering Systems, Part B. Mechanical Engineering
- Vol. 7 (3)
An Equilibrium Prediction Method for Control and Fault Detection of Energy Systems
Many fault detection, optimization, and control logic methods rely on sensor feedback that assumes the system is operating at steady-state conditions, despite persistent transient disturbances. While filtering and signal processing techniques can eliminate some transient effects, this paper proposes an equilibrium prediction method for first-order dynamic systems using an exponential regression. This method is particularly valuable for many commercial and industrial energy system, whose dynamics are dominated by first-order thermo-fluid effects. To illustrate the basic advantages of the proposed approach, Monte Carlo simulations are used. This is followed by three distinct experimental case studies to demonstrate the practical efficacy of the proposed method. First, the ability to predict the carbon dioxide level in classrooms allows for energy efficient control of the ventilation system and ensures occupant comfort. Second, predicting the optimal time to end the cool-down of an industrial sintering furnace allows for maximum part throughput and worker safety. Finally, fault detection and diagnosis (FDD) methods for air conditioning systems typically use static system models; however, the transient response of many air conditioning signals may be approximated as first-order, and therefore, the prediction model enables the use of static fault detection methods with transient data (a need that has not been addressed in over 20 years of air conditioning FDD research). In this paper, the equilibrium prediction method's performance will be quantified using both Monte Carlo simulations and case studies.
- 28 May 2021
- Published by ASME International in ASCE-ASME Journal of Risk and Uncertainty in Engineering Systems, Part B. Mechanical Engineering
- Vol. 7 (3)
An Equilibrium Prediction Method for Control and Fault Detection of Energy Systems
Many fault detection, optimization, and control logic methods rely on sensor feedback that assumes the system is operating at steady-state conditions, despite persistent transient disturbances. While filtering and signal processing techniques can eliminate some transient effects, this paper proposes an equilibrium prediction method for first-order dynamic systems using an exponential regression. This method is particularly valuable for many commercial and industrial energy system, whose dynamics are dominated by first-order thermo-fluid effects. To illustrate the basic advantages of the proposed approach, Monte Carlo simulations are used. This is followed by three distinct experimental case studies to demonstrate the practical efficacy of the proposed method. First, the ability to predict the carbon dioxide level in classrooms allows for energy efficient control of the ventilation system and ensures occupant comfort. Second, predicting the optimal time to end the cool-down of an industrial sintering furnace allows for maximum part throughput and worker safety. Finally, fault detection and diagnosis (FDD) methods for air conditioning systems typically use static system models; however, the transient response of many air conditioning signals may be approximated as first-order, and therefore, the prediction model enables the use of static fault detection methods with transient data (a need that has not been addressed in over 20 years of air conditioning FDD research). In this paper, the equilibrium prediction method's performance will be quantified using both Monte Carlo simulations and case studies.
- Open Access
Steady-State Predictive Optimal Control of Integrated Building Energy Systems Using a Mixed Economic and Occupant Comfort Focused Objective Function
Control of energy systems in buildings is an area of expanding interest as the importance of energy efficiency, occupant health, and comfort increases. The objective of this study was to demonstrate the effectiveness of a novel predictive steady-state optimal control method in minimizing the economic costs associated with operating a building. Specifically, the cost of utility consumption and the cost of loss productivity due to occupant discomfort were minimized. This optimization was achieved through the use of steady-state predictions and component level economic objective functions. Specific objective functions were developed and linear models were identified from data collected from a building on Texas A&M University’s campus. The building consists of multiple zones and is serviced by a variable air volume, chilled water air handling unit. The proposed control method was then co-simulated with MATLAB and EnergyPlus to capture effects across multiple time-scales. Simulation results show improved comfort performance and decreased economic cost over the currently implemented building control, minimizing productivity loss and utility consumption. The potential for more serious consideration of the economic cost of occupant discomfort in building control design is also discussed.
Open AccessSteady-State Predictive Optimal Control of Integrated Building Energy Systems Using a Mixed Economic and Occupant Comfort Focused Objective Function
Control of energy systems in buildings is an area of expanding interest as the importance of energy efficiency, occupant health, and comfort increases. The objective of this study was to demonstrate the effectiveness of a novel predictive steady-state optimal control method in minimizing the economic costs associated with operating a building. Specifically, the cost of utility consumption and the cost of loss productivity due to occupant discomfort were minimized. This optimization was achieved through the use of steady-state predictions and component level economic objective functions. Specific objective functions were developed and linear models were identified from data collected from a building on Texas A&M University’s campus. The building consists of multiple zones and is serviced by a variable air volume, chilled water air handling unit. The proposed control method was then co-simulated with MATLAB and EnergyPlus to capture effects across multiple time-scales. Simulation results show improved comfort performance and decreased economic cost over the currently implemented building control, minimizing productivity loss and utility consumption. The potential for more serious consideration of the economic cost of occupant discomfort in building control design is also discussed.
- 29 October 2019
- Published by Taylor & Francis in Science and Technology for the Built Environment
- Vol. 26 (3) , 320-333
Uncertainty analysis and field implementation of a fault detection method for residential HVAC systems
The vast majority of fault detection and diagnosis (FDD) methods for air conditioning systems are developed for packaged commercial systems. This paper presents a method for obtaining key operating parameters for air conditioning systems (airflow rate, cooling capacity, system efficiency, and refrigerant mass flow) in a way that is well-suited for the residential sector. The method relies on an air-side capacity estimate and will be compared and contrasted with a more traditional method that relies on a refrigerant-side capacity estimate. These methods are compared in terms of their sensitivity to input parameters, their uncertainty in the outputs, and their sensor requirements. The proposed air-side sensing method requires fewer sensors and has a significant advantage for residential split systems because it requires no outdoor unit sensors. The air-side sensing method is then successfully implemented on a field operating residential system. The experimental results show that the proposed method is sensitive to manually introduced airflow faults.
- 29 October 2019
- Published by Taylor & Francis in Science and Technology for the Built Environment
- Vol. 26 (3) , 320-333
Uncertainty analysis and field implementation of a fault detection method for residential HVAC systems
The vast majority of fault detection and diagnosis (FDD) methods for air conditioning systems are developed for packaged commercial systems. This paper presents a method for obtaining key operating parameters for air conditioning systems (airflow rate, cooling capacity, system efficiency, and refrigerant mass flow) in a way that is well-suited for the residential sector. The method relies on an air-side capacity estimate and will be compared and contrasted with a more traditional method that relies on a refrigerant-side capacity estimate. These methods are compared in terms of their sensitivity to input parameters, their uncertainty in the outputs, and their sensor requirements. The proposed air-side sensing method requires fewer sensors and has a significant advantage for residential split systems because it requires no outdoor unit sensors. The air-side sensing method is then successfully implemented on a field operating residential system. The experimental results show that the proposed method is sensitive to manually introduced airflow faults.
- 1 August 2019
- Published by Elsevier in Building and Environment
- Vol. 161
A review of fault detection and diagnosis methods for residential air conditioning systems
- 1 August 2019
- Published by Elsevier in Building and Environment
- Vol. 161
A review of fault detection and diagnosis methods for residential air conditioning systems