Islam Mahmoud Hamdi
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Islam Mahmoud Hamdi has a total of 13 co-authors. Here are the top co-authors by number of shared publications:
Ahmed Galal
Vissum Instituto Oftalmológico de Alicante, Alicante, Spain
2 shared publicationsAlejandra E. Rodriguez
Vissum Instituto Oftalmológico de Alicante, Alicante, Spain
2 shared publicationsJorge L. Alio
Vissum Instituto Oftalmológico de Alicante, Alicante, Spain
2 shared publicationsMomen Mahmoud Hamdi
Ain Shams University, Cairo, Egypt
2 shared publications- Momen Mahmoud Hamdi
Department Ophthalmology of, Faculty of Medicine, Ain Shams University
2 shared publications A. Artola
VISSUM Instituto Oftalmológico de Alicante and Miguel Hernandez University, Alicante - Spain
1 shared publication
Latest Publications
- 22 July 2020
- Published by SAGE Publications in European Journal of Ophthalmology
- Vol. 31 (1) , 49-56
The role of mitomycin C and porcine extracellular matrix in phacotrabeculectomy
To compare between mitomycin C alone, porcine extracellular matrix alone, and combined low dose mitomycin C with porcine extracellular matrix in term of efficacy and safety in phaco-trabeculectomy surgery. Prospective comparative. Sixty eyes of 60 patients complaining of primary open angle glaucoma and cataract, undergoing phaco-trabeculectomy, were distributed into three groups: group I: surgery was augmented with mitomycin C, group II with porcine extracellular matrix, and group III with porcine extracellular matrix combined with low dose mitomycin C. Intraocular pressure was evaluated, postoperatively, at day 1, week 1, and 1, 3, 6, 9, and 12 months. Bleb vascularity, pre- and post-operative intraocular pressure lowering medications, success of IOP control and complications were also evaluated. After 12 months, the mean preoperative intraocular pressure (mm Hg) improved from 30.85 ± 4.7, 33.8 ± 4.2, and 31.05 ± 5.4 mm Hg, in groups I, II, and III respectively, to 13.8 ± 4.7 (55.2%), 15.2 ± 4.8 (55%), and 13 ± 4.9 (58.1%) (p > 0.05). Success of IOP control, postoperative IOP lowering medications and complications were comparable (p > 0.05). Bleb vascularity was significantly different (p < 0.05). Mitomycin C, porcine extracellular matrix and their combination are equally effective in phacotrabeculectomy.
- 22 July 2020
- Published by SAGE Publications in European Journal of Ophthalmology
- Vol. 31 (1) , 49-56
The role of mitomycin C and porcine extracellular matrix in phacotrabeculectomy
To compare between mitomycin C alone, porcine extracellular matrix alone, and combined low dose mitomycin C with porcine extracellular matrix in term of efficacy and safety in phaco-trabeculectomy surgery. Prospective comparative. Sixty eyes of 60 patients complaining of primary open angle glaucoma and cataract, undergoing phaco-trabeculectomy, were distributed into three groups: group I: surgery was augmented with mitomycin C, group II with porcine extracellular matrix, and group III with porcine extracellular matrix combined with low dose mitomycin C. Intraocular pressure was evaluated, postoperatively, at day 1, week 1, and 1, 3, 6, 9, and 12 months. Bleb vascularity, pre- and post-operative intraocular pressure lowering medications, success of IOP control and complications were also evaluated. After 12 months, the mean preoperative intraocular pressure (mm Hg) improved from 30.85 ± 4.7, 33.8 ± 4.2, and 31.05 ± 5.4 mm Hg, in groups I, II, and III respectively, to 13.8 ± 4.7 (55.2%), 15.2 ± 4.8 (55%), and 13 ± 4.9 (58.1%) (p > 0.05). Success of IOP control, postoperative IOP lowering medications and complications were comparable (p > 0.05). Bleb vascularity was significantly different (p < 0.05). Mitomycin C, porcine extracellular matrix and their combination are equally effective in phacotrabeculectomy.
- Open Access
- 1 October 2019
- Published by Taylor & Francis in Clinical Ophthalmology
- Vol. ume 13, 1955-1961
Subjective Perception Of Trifocal IOL Performance, Including Toric Models
Purpose: To study the patients’ perception of trifocal IOL (Panoptix™) performance. Patients and methods: 60 eyes of 35 were implanted with trifocal IOL. Refractive (sphere – S, cylinder – Cyl and spherical equivalent – SE, all in D) and visual (distance uncorrected – VAsc, distance corrected – VAcc, intermediate – IntVA, near uncorrected – NVAsc and distance corrected near – NVAcc, all in LogMAR) results were recorded. Patients were asked about satisfaction (per eye), spectacle independence, near and intermediate activities, distance activities in quantity and quality, finally about personal facial care (per patient). Comparison was made between non-toric (48) and toric models, genders (18 males) and between bilateral (25 patients) and unilateral implantations. Results were correlated to age and IOL power. Results: With a SE of mean −0.3 ± 0.5 D, cases achieved mean VAsc 0.09 ± 0.1 (∼20/25), VAcc 0.05 ± 0.1 (∼20/22), IntVA 0.05 ± 0.9 (∼20/22), NVAsc 0.05 ± 0.09 (∼̴20/22) and NVAcc 0.04 ± 0.8 (̴∼20/22). Mean level of satisfaction was 85.7 ± 16.5, spectacle independence 96.0 ± 10.6, near activities 95.4 ± 9.8, intermediate activities 97.7 ± 6.4, quantity of distance activities 90.2 ± 10.1, quality of distance activities 88.0 ± 12.1 and facial care 92.6 ± 11.9. All comparisons (non-toric and toric, male and female and bilateral and unilateral implantation) were statistically insignificant (P>0.05). Correlation with age and IOL power was also statistically insignificant (P>0.05). Conclusion: As perceived by patients, trifocal IOL resulted in very high level of satisfaction. This satisfaction is reflected on diverse visual activities. This level is achieved regardless of gender, IOL model or even unilateral implantation. It is also achieved regardless the age of patients or preoperative eye status.
- 1 October 2019
- Published by Taylor & Francis in Clinical Ophthalmology
- Vol. ume 13, 1955-1961
Open AccessSubjective Perception Of Trifocal IOL Performance, Including Toric Models
Purpose: To study the patients’ perception of trifocal IOL (Panoptix™) performance. Patients and methods: 60 eyes of 35 were implanted with trifocal IOL. Refractive (sphere – S, cylinder – Cyl and spherical equivalent – SE, all in D) and visual (distance uncorrected – VAsc, distance corrected – VAcc, intermediate – IntVA, near uncorrected – NVAsc and distance corrected near – NVAcc, all in LogMAR) results were recorded. Patients were asked about satisfaction (per eye), spectacle independence, near and intermediate activities, distance activities in quantity and quality, finally about personal facial care (per patient). Comparison was made between non-toric (48) and toric models, genders (18 males) and between bilateral (25 patients) and unilateral implantations. Results were correlated to age and IOL power. Results: With a SE of mean −0.3 ± 0.5 D, cases achieved mean VAsc 0.09 ± 0.1 (∼20/25), VAcc 0.05 ± 0.1 (∼20/22), IntVA 0.05 ± 0.9 (∼20/22), NVAsc 0.05 ± 0.09 (∼̴20/22) and NVAcc 0.04 ± 0.8 (̴∼20/22). Mean level of satisfaction was 85.7 ± 16.5, spectacle independence 96.0 ± 10.6, near activities 95.4 ± 9.8, intermediate activities 97.7 ± 6.4, quantity of distance activities 90.2 ± 10.1, quality of distance activities 88.0 ± 12.1 and facial care 92.6 ± 11.9. All comparisons (non-toric and toric, male and female and bilateral and unilateral implantation) were statistically insignificant (P>0.05). Correlation with age and IOL power was also statistically insignificant (P>0.05). Conclusion: As perceived by patients, trifocal IOL resulted in very high level of satisfaction. This satisfaction is reflected on diverse visual activities. This level is achieved regardless of gender, IOL model or even unilateral implantation. It is also achieved regardless the age of patients or preoperative eye status.
- Open Access
- 29 November 2018
- Published by Springer Nature
Which of these two agents, Mitomycin C and OlogenTM, is better to use when used in surgeries to treat cataract and glaucoma at the same time?
- 29 November 2018
- Published by Springer Nature
Open AccessWhich of these two agents, Mitomycin C and OlogenTM, is better to use when used in surgeries to treat cataract and glaucoma at the same time?
- Open Access
- 12 November 2018
- Published by Wiley in Journal of Ophthalmology
- Vol. 2018, 1-6
Effect of D-Panthenol on Corneal Epithelial Healing after Surface Laser Ablation
Purpose. To study the effect of D-panthenol (provitamin B5) on corneal epithelial healing, in cases of surface laser ablation. Patients and Methods: 45 eyes, of 45 patients undergoing laser surface ablation, received D-panthenol 2% in one eye and artificial tear drops of similar composition not containing D-panthenol in the other eye, postoperatively, for 2 months. Patients were examined daily for 3 days after the procedure. They were then examined weekly for 1 month. An additional examination was made after 2 months. Visual acuity (Log MAR) was assessed at every visit. Rate of healing (% of covered area) and subjective sensation of discomfort (scale 0–5) were assessed in the 1st 3 visits. Residual manifest cylinder (D) (as a parameter of corneal irregularity) and corneal clarity (epithelial and stromal haze) were assessed from week 1 to month 2. Results. During the first 3 days, both groups showed statistically nonsignificant () results. From week 1 to month 2, eyes receiving D-panthenol showed better vision and less residual cylinder () at week 1. For all other parameters, and at different examinations, both groups showed a statistically nonsignificant () difference. Still, eyes receiving D-panthenol showed better values at the majority of the parameters tested. Conclusion. D-Panthenol effect on corneal epithelial regeneration is of minimal clinical relevance. A different dosage and a larger sample of patients might reveal a statistical relevance. This trial is registered with https://doi.org/10.1186/ISRCTN81441126.
- 12 November 2018
- Published by Wiley in Journal of Ophthalmology
- Vol. 2018, 1-6
Open AccessEffect of D-Panthenol on Corneal Epithelial Healing after Surface Laser Ablation
Purpose. To study the effect of D-panthenol (provitamin B5) on corneal epithelial healing, in cases of surface laser ablation. Patients and Methods: 45 eyes, of 45 patients undergoing laser surface ablation, received D-panthenol 2% in one eye and artificial tear drops of similar composition not containing D-panthenol in the other eye, postoperatively, for 2 months. Patients were examined daily for 3 days after the procedure. They were then examined weekly for 1 month. An additional examination was made after 2 months. Visual acuity (Log MAR) was assessed at every visit. Rate of healing (% of covered area) and subjective sensation of discomfort (scale 0–5) were assessed in the 1st 3 visits. Residual manifest cylinder (D) (as a parameter of corneal irregularity) and corneal clarity (epithelial and stromal haze) were assessed from week 1 to month 2. Results. During the first 3 days, both groups showed statistically nonsignificant () results. From week 1 to month 2, eyes receiving D-panthenol showed better vision and less residual cylinder () at week 1. For all other parameters, and at different examinations, both groups showed a statistically nonsignificant () difference. Still, eyes receiving D-panthenol showed better values at the majority of the parameters tested. Conclusion. D-Panthenol effect on corneal epithelial regeneration is of minimal clinical relevance. A different dosage and a larger sample of patients might reveal a statistical relevance. This trial is registered with https://doi.org/10.1186/ISRCTN81441126.
- Open Access
- 17 October 2018
- Published by Springer Nature
The healing effect of Panthenol eye drops on eye wounds from laser vision correction surgeries
- 17 October 2018
- Published by Springer Nature
Open AccessThe healing effect of Panthenol eye drops on eye wounds from laser vision correction surgeries
- Open Access
- 20 July 2017
- Published by Wiley in Journal of Ophthalmology
- Vol. 2017, 1-6
Quality of Vision after Deep Anterior Lamellar Keratoplasty (Fluid Dissection) Compared to Penetrating Keratoplasty for the Treatment of Keratoconus
Purpose. To compare the visual quality of patients with keratoconus who underwent penetrating keratoplasty (PKP) or deep anterior lamellar keratoplasty (DALK) with fluid dissection. Design. Cross-sectional, observational study. Methods. Twelve eyes that underwent PKP (PKP group) were compared to 24 eyes that underwent DALK (DALK group) after complete removal of sutures and stability of refraction. Visual, refractive, corneal topographic, corneal aberrometry, and ocular aberrometry parameters were compared for both groups. The χ2 and Mann–Whitney U tests were used for comparisons as appropriate. was considered statistically significant. Results. Uncorrected and best spectacle-corrected visual acuity (UCVA and BSCVA, resp.), mean refractive spherical equivalent and mean refractive cylinder (MRSE and MRC, resp.), root mean square of the 3 mm and 5 mm OPD Scan (NIDEK Co. Ltd., Gamagori, Japan), steep and flat meridians (SimK1 and SimK2, resp.), and the difference (corneal cylinder) were not statistically significantly different between groups (, all comparisons). All aberrations, point spread functions (PSF), and the modulation transfer function (MTF) were not statistically different between groups (). Conclusion. For our small study, the postoperative PKP and DALK with fluid dissection patient groups had vision/optical quality parameters that were not statistically different. This may indicate that DALK with fluid dissection can replace PKP for keratoconus without compromising vision quality.- 20 July 2017
- Published by Wiley in Journal of Ophthalmology
- Vol. 2017, 1-6
Open AccessQuality of Vision after Deep Anterior Lamellar Keratoplasty (Fluid Dissection) Compared to Penetrating Keratoplasty for the Treatment of Keratoconus
Purpose. To compare the visual quality of patients with keratoconus who underwent penetrating keratoplasty (PKP) or deep anterior lamellar keratoplasty (DALK) with fluid dissection. Design. Cross-sectional, observational study. Methods. Twelve eyes that underwent PKP (PKP group) were compared to 24 eyes that underwent DALK (DALK group) after complete removal of sutures and stability of refraction. Visual, refractive, corneal topographic, corneal aberrometry, and ocular aberrometry parameters were compared for both groups. The χ2 and Mann–Whitney U tests were used for comparisons as appropriate. was considered statistically significant. Results. Uncorrected and best spectacle-corrected visual acuity (UCVA and BSCVA, resp.), mean refractive spherical equivalent and mean refractive cylinder (MRSE and MRC, resp.), root mean square of the 3 mm and 5 mm OPD Scan (NIDEK Co. Ltd., Gamagori, Japan), steep and flat meridians (SimK1 and SimK2, resp.), and the difference (corneal cylinder) were not statistically significantly different between groups (, all comparisons). All aberrations, point spread functions (PSF), and the modulation transfer function (MTF) were not statistically different between groups (). Conclusion. For our small study, the postoperative PKP and DALK with fluid dissection patient groups had vision/optical quality parameters that were not statistically different. This may indicate that DALK with fluid dissection can replace PKP for keratoconus without compromising vision quality. - Open Access
- 3 October 2016
- Published by MedCrave Group Kft. in Advances in Ophthalmology & Visual System
- Vol. 5 (1) , 1
Eye Injury and Sports
During sports, eye injury might result from a direct contact, either with an opponent or an instrument (racket or ball) used in practice. The rate of injury varies according to the type of sports practiced. The type and extent of damage also vary from one accident to the other. Golf, hockey, squash and tennis rackets are well known causative agents for trauma. Tennis and squash balls are also famous of causing rupture globe with a blunt trauma. Direct contact with the opponents in martial arts, rugby and American football without the protective gadgets raises the risk of injury by many folds. Even without contact, practicing sports in extreme environment, like running in cold wind and scuba diving offer an additional stress to the ocular surface.
- 3 October 2016
- Published by MedCrave Group Kft. in Advances in Ophthalmology & Visual System
- Vol. 5 (1) , 1
Open AccessEye Injury and Sports
During sports, eye injury might result from a direct contact, either with an opponent or an instrument (racket or ball) used in practice. The rate of injury varies according to the type of sports practiced. The type and extent of damage also vary from one accident to the other. Golf, hockey, squash and tennis rackets are well known causative agents for trauma. Tennis and squash balls are also famous of causing rupture globe with a blunt trauma. Direct contact with the opponents in martial arts, rugby and American football without the protective gadgets raises the risk of injury by many folds. Even without contact, practicing sports in extreme environment, like running in cold wind and scuba diving offer an additional stress to the ocular surface.
- Open Access
- 10 January 2015
- Published by Sciencedomain International in Ophthalmology Research: An International Journal
- Vol. 4 (1) , 16-24
Collagen Matrix Implant (Ologen)TM in Glaucoma Surgeries; Precautions for a Better Control of Intraocular Pressure
Background: Collagen matrix implant (CM) is used in glaucoma surgery to regulate healing under the conjunctiva. Purpose: To highlight the precautions that should be taken for a better intraocular pressure (IOP) control with CM in different glaucoma surgeries during and after the operation. Methods: Thirty five cases of glaucoma were treated surgically with adjunctive OlogenTM. a) Fifteen subscleral trabeculectomies (SST): for adult Primary Open Angle Glaucoma (POAG). b) Five SST's for Primary Congenital Glaucoma (PCG). c) Fifteen Phaco-trabeculectomies for advanced POAG with cataract. One was converted to extracapsular cataract extraction with SST because of a subluxated (270 degree) cataractous lens with advanced glaucoma. The number of 10/0 nylon stitches to close the scleral flap, the method of closure of the fornix based conjunctival flap and injection of Na hyaluronate at the end of the surgery were evaluated. Postoperatively: Anterior chamber(AC) depth, the need for ocular massage, any additional medications or further surgical intervention were assessed. Results: Better IOP control was obtained with slightly shallow AC postoperatively and tight conjunctival closure. Ocular massage may be needed as well as medications for cases which experienced tight closures of the scleral flap. Three SST´s and four phaco-trabeculectomies needed supplemental medications after surgeries. Failure in one SST (PCG) and two phacotrabeculectomies was due to presence of additional risk factors in the patients. The rest of cases went successfully with IOP < 21 mm Hg without medications. Conclusion: CM is a successful adjunct to glaucoma surgeries, intraoperative and postoperative precautions should be taken to maintain proper aqueous drainage and functioning blebs to improve the degree of success.
- 10 January 2015
- Published by Sciencedomain International in Ophthalmology Research: An International Journal
- Vol. 4 (1) , 16-24
Open AccessCollagen Matrix Implant (Ologen)TM in Glaucoma Surgeries; Precautions for a Better Control of Intraocular Pressure
Background: Collagen matrix implant (CM) is used in glaucoma surgery to regulate healing under the conjunctiva. Purpose: To highlight the precautions that should be taken for a better intraocular pressure (IOP) control with CM in different glaucoma surgeries during and after the operation. Methods: Thirty five cases of glaucoma were treated surgically with adjunctive OlogenTM. a) Fifteen subscleral trabeculectomies (SST): for adult Primary Open Angle Glaucoma (POAG). b) Five SST's for Primary Congenital Glaucoma (PCG). c) Fifteen Phaco-trabeculectomies for advanced POAG with cataract. One was converted to extracapsular cataract extraction with SST because of a subluxated (270 degree) cataractous lens with advanced glaucoma. The number of 10/0 nylon stitches to close the scleral flap, the method of closure of the fornix based conjunctival flap and injection of Na hyaluronate at the end of the surgery were evaluated. Postoperatively: Anterior chamber(AC) depth, the need for ocular massage, any additional medications or further surgical intervention were assessed. Results: Better IOP control was obtained with slightly shallow AC postoperatively and tight conjunctival closure. Ocular massage may be needed as well as medications for cases which experienced tight closures of the scleral flap. Three SST´s and four phaco-trabeculectomies needed supplemental medications after surgeries. Failure in one SST (PCG) and two phacotrabeculectomies was due to presence of additional risk factors in the patients. The rest of cases went successfully with IOP < 21 mm Hg without medications. Conclusion: CM is a successful adjunct to glaucoma surgeries, intraoperative and postoperative precautions should be taken to maintain proper aqueous drainage and functioning blebs to improve the degree of success.
- 1 April 2013
- Published by Wolters Kluwer Health in Cornea
- Vol. 32 (4) , e2-e5
Refractive and Visual Outcomes of Penetrating Keratoplasty Versus Deep Anterior Lamellar Keratoplasty With Hydrodissection for Treatment of Keratoconus
To compare refractive and visual outcomes of penetrating keratoplasty (PKP) and deep anterior lamellar keratoplasty (DALK) with hydrodissection for keratoconus. A review of medical records was performed to identify 69 subjects (77 eyes) who had undergone keratoplasty by a single surgeon. Inclusion criteria were as follows: no episodes of rejection, no adverse events or complications intraoperatively or postoperatively, a fairly normal rate of epithelialization within 2 weeks, and suture removal after 11 months. Eyes were categorized according to the procedure: 47 had undergone DALK with hydrodissection (DALK group) and 30 had undergone PKP (PKP group). A between-group comparison was performed. Before suture removal, there was no statistical difference between groups in best-corrected visual acuity (BCVA) or refraction at 6 months (P > 0.05, all cases). The mean BCVA was 0.18 logarithm of the minimum angle of resolution for both groups at 12 months (just after suture removal) and 24 months postoperatively. The mean postoperative mean refractive spherical equivalents at 12 months and 2 years were -4.11 ± 3.4 diopters (D) and -4.68 ± 2.9 D, respectively, for the DALK group and -1.7 ± 2.7 D and -1.1 ± 3.6 D, respectively, for the PKP group. The DALK group was statistically more myopic at 12 and 24 months (P > 0.05, both cases). The mean refractive cylinders at 12 months and 2 years were 2.88 ± 1.60 D and 3.18 ± 1.70 D, respectively, for the DALK group and 2.80 ± 1.6 D and 3.80 ± 1.80 D, respectively, for the PKP group. The differences between groups were not statistically significant (P > 0.05, all comparisons). Long-term BCVA, mean refractive spherical equivalent, and mean refractive cylinder after DALK with hydrodissection were similar to those after PKP.
- 1 April 2013
- Published by Wolters Kluwer Health in Cornea
- Vol. 32 (4) , e2-e5
Refractive and Visual Outcomes of Penetrating Keratoplasty Versus Deep Anterior Lamellar Keratoplasty With Hydrodissection for Treatment of Keratoconus
To compare refractive and visual outcomes of penetrating keratoplasty (PKP) and deep anterior lamellar keratoplasty (DALK) with hydrodissection for keratoconus. A review of medical records was performed to identify 69 subjects (77 eyes) who had undergone keratoplasty by a single surgeon. Inclusion criteria were as follows: no episodes of rejection, no adverse events or complications intraoperatively or postoperatively, a fairly normal rate of epithelialization within 2 weeks, and suture removal after 11 months. Eyes were categorized according to the procedure: 47 had undergone DALK with hydrodissection (DALK group) and 30 had undergone PKP (PKP group). A between-group comparison was performed. Before suture removal, there was no statistical difference between groups in best-corrected visual acuity (BCVA) or refraction at 6 months (P > 0.05, all cases). The mean BCVA was 0.18 logarithm of the minimum angle of resolution for both groups at 12 months (just after suture removal) and 24 months postoperatively. The mean postoperative mean refractive spherical equivalents at 12 months and 2 years were -4.11 ± 3.4 diopters (D) and -4.68 ± 2.9 D, respectively, for the DALK group and -1.7 ± 2.7 D and -1.1 ± 3.6 D, respectively, for the PKP group. The DALK group was statistically more myopic at 12 and 24 months (P > 0.05, both cases). The mean refractive cylinders at 12 months and 2 years were 2.88 ± 1.60 D and 3.18 ± 1.70 D, respectively, for the DALK group and 2.80 ± 1.6 D and 3.80 ± 1.80 D, respectively, for the PKP group. The differences between groups were not statistically significant (P > 0.05, all comparisons). Long-term BCVA, mean refractive spherical equivalent, and mean refractive cylinder after DALK with hydrodissection were similar to those after PKP.
- 1 June 2011
- Published by Wolters Kluwer Health in Journal of Cataract & Refractive Surgery
- Vol. 37 (6) , 1125-1132
Preliminary results of intrastromal corneal ring segment implantation to treat moderate to severe keratoconus
To present our preliminary experience with implantation of Ferrara intrastromal corneal ring segments (ICRS) in keratoconus patients. Magrabi Eye and Ear Center, Jeddah, Saudi Arabia. Case series. This study comprised patients diagnosed with primary keratoconus who had ICRS implantation. Uncorrected (UDVA) and corrected (CDVA) distance visual acuities were recorded. The change in manifest refraction spherical equivalent (MRSE), mean refractive cylinder, average simulated keratometry (K), and topographic cylinder from preoperatively to 6 months postoperatively was analyzed, and complications were noted. The t test was used to compare 2 independent means and the Wilcoxon signed-rank test, to compare nonparametric data. By 6 months postoperatively, the CDVA was unchanged in 27% of cases and had improved between 1 line and 6 lines in 64% of cases; 9% of cases lost 1 or 2 lines. There was a decrease in the following mean values: MRSE (-3.60 diopters [D] ± 3.10 [SD] to -2.52 ± 3.10 D; P = .209); refractive cylinder (5.18 ± 2.10 D to 2.90 ± 2.50 D; P = .000); simulated K (51.16 ± 5.60 D to 48.11 ± 3.60 D; P = .000); topographic cylinder (5.30 ± 2.80 D to 3.80 ± 3.20 D; P = .000). For cases with a 24-month follow-up, stability was similar for all parameters. Intraoperative or postoperative complications occurred in 13% of cases; all were managed without clinically significant visual loss. Implantation of ICRS resulted in reasonable refractive and visual outcomes in a wide spectrum of keratoconus cases. The author has no financial or proprietary interest in any material or method mentioned. Additional disclosure is found in the footnotes.
- 1 June 2011
- Published by Wolters Kluwer Health in Journal of Cataract & Refractive Surgery
- Vol. 37 (6) , 1125-1132
Preliminary results of intrastromal corneal ring segment implantation to treat moderate to severe keratoconus
To present our preliminary experience with implantation of Ferrara intrastromal corneal ring segments (ICRS) in keratoconus patients. Magrabi Eye and Ear Center, Jeddah, Saudi Arabia. Case series. This study comprised patients diagnosed with primary keratoconus who had ICRS implantation. Uncorrected (UDVA) and corrected (CDVA) distance visual acuities were recorded. The change in manifest refraction spherical equivalent (MRSE), mean refractive cylinder, average simulated keratometry (K), and topographic cylinder from preoperatively to 6 months postoperatively was analyzed, and complications were noted. The t test was used to compare 2 independent means and the Wilcoxon signed-rank test, to compare nonparametric data. By 6 months postoperatively, the CDVA was unchanged in 27% of cases and had improved between 1 line and 6 lines in 64% of cases; 9% of cases lost 1 or 2 lines. There was a decrease in the following mean values: MRSE (-3.60 diopters [D] ± 3.10 [SD] to -2.52 ± 3.10 D; P = .209); refractive cylinder (5.18 ± 2.10 D to 2.90 ± 2.50 D; P = .000); simulated K (51.16 ± 5.60 D to 48.11 ± 3.60 D; P = .000); topographic cylinder (5.30 ± 2.80 D to 3.80 ± 3.20 D; P = .000). For cases with a 24-month follow-up, stability was similar for all parameters. Intraoperative or postoperative complications occurred in 13% of cases; all were managed without clinically significant visual loss. Implantation of ICRS resulted in reasonable refractive and visual outcomes in a wide spectrum of keratoconus cases. The author has no financial or proprietary interest in any material or method mentioned. Additional disclosure is found in the footnotes.