JHJustin P. Haldar

Justin P. Haldar

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Justin P. Haldar has a total of 169 co-authors. Here are the top co-authors by number of shared publications:

  • Zhi-Pei Liang

    27 shared publications
  • Richard M. Leahy

    Signal and Image Processing Institute, Ming Hsieh Department of Electrical and Computer Engineering University of Southern California Los Angeles California USA

    10 shared publications
  • Anand A. Joshi

    Ming Hsieh Department of Electrical and Computer Engineering Viterbi School of Engineering, University of Southern California Los Angeles California USA

    9 shared publications
  • Bradley P. Sutton

    Beckman Institute, University of Illinois at Urbana-Champaign, USA

    9 shared publications
  • Richard M. Leahy

    Department of Electrical and Computer Engineering University of Southern California Los Angeles 90089 CA USA

    8 shared publications
  • Diego Hernando

    Department of Electrical and Computer Engineering and the Beckman Institute for Advanced Science and Technology, University of Illinois at Urbana-Champaign, Urbana, IL, USA

    7 shared publications

Latest Publications

  • Open Access

    Well-designed k-space coverage is important for good MRI denoising

    by Jiayang Wang, Justin P. Haldar

    Objective:: Modern computational MRI denoising approaches are often designed assuming fixed k-space coverage. This contrasts with earlier acquisition-design literature that leveraged k-space coverage modifications (e.g., reducing spatial resolution) to improve SNR. This work investigates whether the performance of modern computational denoising methods can be further enhanced by k-space coverage modifications. Materials and methods:: Using realistic simulations of noisy data, k-space coverage and averaging patterns were optimized for two advanced image denoising/reconstruction approaches: parallel imaging with total variation regularization and a U-Net neural network. For reference, comparisons against classical linear filtering/apodization methods were also performed. Performance was quantified using normalized root-mean-squared error (NRMSE) and structural similarity (SSIM) metrics. Results:: Advanced computational denoising methods can be substantially enhanced, both quantitatively and qualitatively, by reducing the spatial resolution of the acquisition to improve SNR. Indeed, even simple linear filtering/apodization with optimized k-space coverage can rival advanced methods using naive higher-resolution coverage. Discussion:: Classical acquisition design principles that allow spatial resolution to be traded for SNR enhancement are still very relevant for modern computational denoising techniques. However, the optimization of k-space coverage and denoising/reconstruction methods can also be somewhat confounded because the NRMSE and SSIM metrics have low sensitivity to spatial resolution.


  • A New k-Space Model for Non-Cartesian Fourier Imaging

    by Chin-Cheng Chan, Justin P. Haldar

    For the past several decades, it has been popular to reconstruct Fourier imaging data using model-based approaches that can easily incorporate physical constraints and advanced regularization/machine learning priors. The most common modeling approach is to represent the continuous image as a linear combination of shifted “voxel” basis functions. Although well-studied and widely-deployed, this voxel-based model is associated with longstanding limitations, including high computational costs, slow convergence, and a propensity for artifacts. In this work, we reexamine this model from a fresh perspective, identifying new issues that may have been previously overlooked (including undesirable approximation, wrap-around, and nullspace characteristics). Our insights motivate us to propose a new model that is more resilient to the limitations (old and new) of the previous approach. Specifically, the new model is based on a Fourier-domain basis expansion rather than the standard image-domain voxel-based approach. Illustrative results, which are presented in the context of non-Cartesian MRI reconstruction, demonstrate that the new model enables improved image quality (reduced artifacts) and/or reduced computational complexity (faster computations and improved convergence).

  • An Efficient Algorithm for Spatial-Spectral Partial Volume Compartment Mapping With Applications to Multicomponent Diffusion and Relaxation MRI

    by Yunsong Liu, Debdut Mandal, Congyu Liao, Kawin Setsompop, Justin P. Haldar

    We introduce a new algorithm to solve a regularized spatial-spectral image estimation problem. Our approach is based on the linearized alternating directions method of multipliers (LADMM), which is a variation of the popular ADMM algorithm. Although LADMM has existed for some time, it has not been very widely used in the computational imaging literature. This is in part because there are many possible ways of mapping LADMM to a specific optimization problem, and it is nontrivial to find a computationally efficient implementation out of the many competing alternatives. We believe that our proposed implementation represents the first application of LADMM to the type of optimization problem considered in this work (involving a linear-mixture forward model, spatial regularization, and nonnegativity constraints). We evaluate our algorithm in a variety of multiparametric MRI partial volume mapping scenarios (diffusion-relaxation, relaxation-relaxation, relaxometry, and fingerprinting), where we consistently observe substantial ($\sim 3\times$-50×) speed improvements. We expect this to reduce barriers to using spatially-regularized partial volume compartment mapping methods. Further, the considerable improvements we observed also suggest the potential value of considering LADMM for a broader set of computational imaging problems.


  • Open Access

    A New k-Space Model for Non-Cartesian Fourier Imaging

    by Chin-Cheng Chan, Justin P. Haldar

    For the past several decades, it has been popular to reconstruct Fourier imaging data using model-based approaches that can easily incorporate physical constraints and advanced regularization/machine learning priors. The most common modeling approach is to represent the continuous image as a linear combination of shifted "voxel" basis functions. Although well-studied and widely-deployed, this voxel-based model is associated with longstanding limitations, including high computational costs, slow convergence, and a propensity for artifacts. In this work, we reexamine this model from a fresh perspective, identifying new issues that may have been previously overlooked (including undesirable approximation, periodicity, and nullspace characteristics). Our insights motivate us to propose a new model that is more resilient to the limitations (old and new) of the previous approach. Specifically, the new model is based on a Fourier-domain basis expansion rather than the standard image-domain voxel-based approach. Illustrative results, which are presented in the context of non-Cartesian MRI reconstruction, demonstrate that the new model enables improved image quality (reduced artifacts) and/or reduced computational complexity (faster computations and improved convergence).

  • Open Access

    Shannon-like Interpolation with Spectral Priors and Weighted Hilbert Spaces: Beyond the Nyquist Rate

    by Justin P. Haldar

    In this work, we draw connections between the classical Shannon interpolation of bandlimited deterministic signals and the literature on estimating continuous-time random processes from their samples (known in various communities under different names, such as Wiener-Kolmogorov filtering, Gaussian process regression, and kriging). This leads to the realization that Shannon interpolation can be interpreted as implicitly expecting that the unknown signal has uniform spectral density within its bandwidth. However, in many practical applications, we often expect more energy at some frequencies than at others. This leads us to propose novel Shannon-like interpolators that are optimal with respect to appropriately-constructed weighted Hilbert spaces, where weighting enables us to accommodate prior information about nonuniform spectral density. Although our new interpolants are derived for data obtained with any sampling rate, we observe that they are particularly useful for interpolating sub-Nyquist data. In addition to theory, we also discuss aspects of practical implementation and show illustrative examples to demonstrate the potential benefits of the approach.

  • Spherical echo‐planar time‐resolved imaging (sEPTI) for rapid 3D quantitative T2* and susceptibility imaging

    by Nan Wang, Congyu Liao, Xiaozhi Cao, Mark Nishimura, Yannick W. E. Brackenier, Mahmut Yurt, Mengze Gao, Daniel Abraham, Cagan Alkan, Siddharth Srinivasan Iyer, et al.

    Purpose: To develop a 3D spherical EPTI (sEPTI) acquisition and a comprehensive reconstruction pipeline for rapid high‐quality whole‐brain submillimeter and QSM quantification.Methods: For the sEPTI acquisition, spherical k‐space coverage is utilized with variable echo‐spacing and maximum kx ramp‐sampling to improve efficiency and signal incoherency compared to existing EPTI approaches. For reconstruction, an iterative rank‐shrinking B0 estimation and odd‐even high‐order phase correction algorithms were incorporated into the reconstruction to better mitigate artifacts from field imperfections. A physics‐informed unrolled network was utilized to boost the SNR, where 1‐mm and 0.75‐mm isotropic whole‐brain imaging were performed in 45 and 90 s at 3 T, respectively. These protocols were validated through simulations, phantom, and in vivo experiments. Ten healthy subjects were recruited to provide sufficient data for the unrolled network. The entire pipeline was validated on additional five healthy subjects where different EPTI sampling approaches were compared. Two additional pediatric patients with epilepsy were recruited to demonstrate the generalizability of the unrolled reconstruction.Results: sEPTI achieved 1.4 faster imaging with improved image quality and quantitative map precision compared to existing EPTI approaches. The B0 update and the phase correction provide improved reconstruction performance with lower artifacts. The unrolled network boosted the SNR, achieving high‐quality and QSM quantification with single average data. High‐quality reconstruction was also obtained in the pediatric patients using this network.Conclusion: sEPTI achieved whole‐brain distortion‐free multi‐echo imaging and and QSM quantification at 0.75 mm in 90 s which has the potential to be useful for wide clinical applications.


  • Open Access

    Diffusion tensor brain imaging at 0.55T: A feasibility study

    by Hao‐Ting Kung, Sophia X. Cui, Jonas T. Kaplan, Anand A. Joshi, Richard M. Leahy, Krishna S. Nayak, Justin P. Haldar

    To investigate the feasibility of diffusion tensor brain imaging at 0.55T with comparisons against 3T. Diffusion tensor imaging data with 2 mm isotropic resolution was acquired on a cohort of five healthy subjects using both 0.55T and 3T scanners. The signal-to-noise ratio (SNR) of the 0.55T data was improved using a previous SNR-enhancing joint reconstruction method that jointly reconstructs the entire set of diffusion weighted images from k-space using shared-edge constraints. Quantitative diffusion tensor parameters were estimated and compared across field strengths. We also performed a test-retest assessment of repeatability at each field strength. After applying SNR-enhancing joint reconstruction, the diffusion tensor parameters obtained from 0.55T data were strongly correlated ( R 2 ≥ 0 . 70 $$ {R}^2\ge 0.70 $$ ) with those obtained from 3T data. Test-retest analysis showed that SNR-enhancing reconstruction improved the repeatability of the 0.55T diffusion tensor parameters. High-resolution in vivo diffusion MRI of the human brain is feasible at 0.55T when appropriate noise-mitigation strategies are applied.


  • Open Access

    The “hidden noise” problem in MR image reconstruction

    by Jiayang Wang, Di An, Justin P. Haldar

    Purpose: The performance of modern image reconstruction methods is commonly judged using quantitative error metrics like root mean squared‐error and the structural similarity index, which are calculated by comparing reconstructed images against fully sampled reference data. In practice, the reference data will contain noise and is not a true gold standard. In this work, we demonstrate that the “hidden noise” present in reference data can substantially confound standard approaches for ranking different image reconstruction results.Methods: Using both experimental and simulated k‐space data and several different image reconstruction techniques, we examined whether there was correlation between performance metrics obtained with typical noisy reference data versus those obtained with higher‐quality reference data.Results: For conventional performance metrics, the reconstructions that matched best with the higher‐quality reference data were substantially different from the reconstructions that matched best with typical noisy reference data. This leads to suboptimal reconstruction results if the performance with respect to noisy reference data is used to select which reconstruction methods/parameters to employ. These issues were reduced when employing alternative error metrics that better account for noise.Conclusion: Reference data containing hidden noise can substantially mislead the ranking of image reconstruction methods when using conventional error metrics, but this issue can be mitigated with alternative error metrics.


  • Open Access

    Spherical Echo-Planar Time-resolved Imaging (sEPTI) for rapid 3D quantitative T2* and Susceptibility imaging

    by Nan Wang, Congyu Liao, Xiaozhi Cao, Mark Nishimura, Yannick We Brackenier, Mahmut Yurt, Mengze Gao, Daniel Abraham, Cagan Alkan, Siddharth Srinivasan Iyer, et al.

    Purpose: To develop a 3D spherical EPTI (sEPTI) acquisition and a comprehensive reconstruction pipeline for rapid high-quality whole-brain submillimeter T2* and QSM quantification. Methods: For the sEPTI acquisition, spherical k-space coverage is utilized with variable echo-spacing and maximum k x ramp-sampling to improve efficiency and incoherency when compared to existing EPTI approaches. For reconstruction, an iterative rank-shrinking B 0 estimation and odd-even high-order phase correction algorithms were incorporated into the reconstruction to better mitigate artifacts from field imperfections. A physics-informed unrolled network was utilized to boost the SNR, where 1-mm and 0.75-mm isotropic whole-brain imaging were performed in 45 and 90 seconds, respectively. These protocols were validated through simulations, phantom, and in vivo experiments. Ten healthy subjects were recruited to provide sufficient data for the unrolled network. The entire pipeline was validated on additional 5 healthy subjects where different EPTI sampling approaches were compared. Two additional pediatric patients with epilepsy were recruited to demonstrate the generalizability of the unrolled reconstruction. Results: sEPTI achieved 1.4 × faster imaging with improved image quality and quantitative map precision compared to existing EPTI approaches. The B0 update and the phase correction provide improved reconstruction performance with lower artifacts. The unrolled network boosted the SNR, achieving high-quality T2* and QSM quantification with single average data. High-quality reconstruction was also obtained in the pediatric patient using this network. Conclusion: sEPTI achieved whole-brain distortion-free multi-echo imaging and T2* and QSM quantification at 0.75 mm in 90 seconds which has the potential to be useful for wide clinical applications.