Niyousha Mortaza
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Research Interests
Niyousha Mortaza has a total of 27 co-authors. Here are the top co-authors by number of shared publications:
- Cheryl Mary Glazebrook
Faculty of Kinesiology and Recreation Management, University of Manitoba
5 shared publications - Steven R. Passmore
Faculty of Kinesiology and Recreation Management, University of Manitoba
4 shared publications Ali Ashraf Jamshidi
Department of Physical Therapy, Faculty of Rehabilitation, Tehran University of Medical Sciences, Tehran, Iran
2 shared publications- Katinka Stecina
Department of Physiology and Pathophysiology, Spinal Cord Research Centre, Rady Faculty of Health Sciences, University of Manitoba Winnipeg
2 shared publications - Noor Azuan Abu Osman
Centre for Applied Biomechanics, Department of Biomedical Engineering, Faculty of Engineering, Universiti Malaya, Kuala Lumpur, Malaysia
2 shared publications Ahmed M. Abou-Setta
George & Fay Yee Center for Healthcare Innovation, University of Manitoba, Winnipeg, MB, Canada
1 shared publication
Latest Publications
- 31 October 2023
- Published by Taylor & Francis in Somatosensory & Motor Research
- Vol. 41 (4) , 238-253
Dual muscle tendon vibration does not impede performance of a goal-directed aiming task
Application of muscle-tendon vibration within the frequency range of 70-120Hz has been studied as a tool to stimulate somatosensory afferents with both the goal of studying human sensorimotor control and of improving post-stroke motor performance. Specific to applications for rehabilitation, current evidence is mixed as to whether dual muscle-tendon vibration is detrimental to the performance of goal-directed upper-limb movements. The current study aimed to determine the effects of muscle-tendon vibration over the wrist flexors and extensors (dual vibration) on performance of a computer goal-directed aiming task. Twenty healthy participants were assigned to the vibration or control group. An aiming task that involved acquiring targets by moving an unseen cursor on a screen was performed. Vision of the cursor and hand were unavailable throughout the four blocks of movement execution. Only the vibration group received dual vibration throughout four blocks. Task performance was assessed using measures of endpoint accuracy and timing. Perceived hand location was assessed using a set of questions and a computerised conscious perception task. The vibration group had significantly shorter reaction times, without any change in endpoint accuracy, indicating more efficient and effective movement planning. The vibration group did report illusory movement sensation, which was reduced by block 4. Dual vibration did not adversely affect aiming accuracy and showed some improvement in reaction time. The present findings support the potential for using dual vibration to stimulate the somatosensory system as participants improved their performance of a novel goal-directed movement. Notably, improvements were maintained when the vibration was removed.
- 31 October 2023
- Published by Taylor & Francis in Somatosensory & Motor Research
- Vol. 41 (4) , 238-253
Dual muscle tendon vibration does not impede performance of a goal-directed aiming task
Application of muscle-tendon vibration within the frequency range of 70-120Hz has been studied as a tool to stimulate somatosensory afferents with both the goal of studying human sensorimotor control and of improving post-stroke motor performance. Specific to applications for rehabilitation, current evidence is mixed as to whether dual muscle-tendon vibration is detrimental to the performance of goal-directed upper-limb movements. The current study aimed to determine the effects of muscle-tendon vibration over the wrist flexors and extensors (dual vibration) on performance of a computer goal-directed aiming task. Twenty healthy participants were assigned to the vibration or control group. An aiming task that involved acquiring targets by moving an unseen cursor on a screen was performed. Vision of the cursor and hand were unavailable throughout the four blocks of movement execution. Only the vibration group received dual vibration throughout four blocks. Task performance was assessed using measures of endpoint accuracy and timing. Perceived hand location was assessed using a set of questions and a computerised conscious perception task. The vibration group had significantly shorter reaction times, without any change in endpoint accuracy, indicating more efficient and effective movement planning. The vibration group did report illusory movement sensation, which was reduced by block 4. Dual vibration did not adversely affect aiming accuracy and showed some improvement in reaction time. The present findings support the potential for using dual vibration to stimulate the somatosensory system as participants improved their performance of a novel goal-directed movement. Notably, improvements were maintained when the vibration was removed.
- Open Access
- 19 September 2023
- Published by MDPI AG in Brain Sciences
- Vol. 13 (9) , 1341
Adapting to Altered Sensory Input: Effects of Induced Paresthesia on Goal-Directed Movement Planning and Execution
The current study investigated how temporarily induced paresthesia in the moving limb affects the performance of a goal-directed target aiming task. Three-dimensional displacement data of 14 neurotypical participants were recorded while they pointed to a target on a computer monitor in four conditions: (i) paresthesia-full-vision; (ii) paresthesia-without-target vision; (iii) no-paresthesia-full-vision; (iv) no paresthesia-without-target vision. The four conditions were blocked and counterbalanced such that participants performed the paresthesia and no-paresthesia conditions on two separate days. To assess how aiming performance changed in the presence of paresthesia, we compared early versus late performance (first and last 20% of trials). We found that endpoint accuracy and movement speed were reduced in the presence of paresthesia, but only without target vision. With repetition, participants adjusted their movement performance strategy, such that with induced paresthesia, they used a movement strategy that included more pre-planned movements that depended less on online control.
- 19 September 2023
- Published by MDPI AG in Brain Sciences
- Vol. 13 (9) , 1341
Open AccessAdapting to Altered Sensory Input: Effects of Induced Paresthesia on Goal-Directed Movement Planning and Execution
The current study investigated how temporarily induced paresthesia in the moving limb affects the performance of a goal-directed target aiming task. Three-dimensional displacement data of 14 neurotypical participants were recorded while they pointed to a target on a computer monitor in four conditions: (i) paresthesia-full-vision; (ii) paresthesia-without-target vision; (iii) no-paresthesia-full-vision; (iv) no paresthesia-without-target vision. The four conditions were blocked and counterbalanced such that participants performed the paresthesia and no-paresthesia conditions on two separate days. To assess how aiming performance changed in the presence of paresthesia, we compared early versus late performance (first and last 20% of trials). We found that endpoint accuracy and movement speed were reduced in the presence of paresthesia, but only without target vision. With repetition, participants adjusted their movement performance strategy, such that with induced paresthesia, they used a movement strategy that included more pre-planned movements that depended less on online control.
- Open Access
- 9 September 2023
- Published by MDPI AG in Brain Sciences
- Vol. 13 (9) , 1302
Optimizing Movement Performance with Altered Sensation: An Examination of Multisensory Inputs
Two experiments were conducted to assess the impact of induced paresthesia on movement parameters of goal-directed aiming movements to determine how visual and auditory feedback may enhance performance when somatosensory feedback is disrupted. In both experiments, neurotypical adults performed the goal-directed aiming task in four conditions: (i) paresthesia—full vision; (ii) paresthesia—no vision; (iii) no paresthesia—full vision; (iv) no paresthesia—no vision. Targets appeared on a computer screen, vision was obscured using visual occlusion spectacles, and paresthesia was induced with a constant current stimulator. The first and last 20% of trials (early and late performance) were compared to assess adaptability to altered somatosensory input. Experiment 2 added an auditory tone that confirmed successful target acquisitions. When compared to early performance in the no-paresthesia and no-vision conditions, induced paresthesia and no vision led to significantly larger endpoint error toward the body midline in both early and late performance. This finding reveals the importance of proprioceptive input for movement accuracy in the absence of visual feedback. The kinematic results indicated that vision could not fully compensate for the disrupted proprioceptive input when participants experienced induced paresthesia. However, when auditory feedback confirmed successful aiming movements in Experiment 2, participants were able to improve their endpoint variability when experiencing induced paresthesia through changes in movement preparation.
- 9 September 2023
- Published by MDPI AG in Brain Sciences
- Vol. 13 (9) , 1302
Open AccessOptimizing Movement Performance with Altered Sensation: An Examination of Multisensory Inputs
Two experiments were conducted to assess the impact of induced paresthesia on movement parameters of goal-directed aiming movements to determine how visual and auditory feedback may enhance performance when somatosensory feedback is disrupted. In both experiments, neurotypical adults performed the goal-directed aiming task in four conditions: (i) paresthesia—full vision; (ii) paresthesia—no vision; (iii) no paresthesia—full vision; (iv) no paresthesia—no vision. Targets appeared on a computer screen, vision was obscured using visual occlusion spectacles, and paresthesia was induced with a constant current stimulator. The first and last 20% of trials (early and late performance) were compared to assess adaptability to altered somatosensory input. Experiment 2 added an auditory tone that confirmed successful target acquisitions. When compared to early performance in the no-paresthesia and no-vision conditions, induced paresthesia and no vision led to significantly larger endpoint error toward the body midline in both early and late performance. This finding reveals the importance of proprioceptive input for movement accuracy in the absence of visual feedback. The kinematic results indicated that vision could not fully compensate for the disrupted proprioceptive input when participants experienced induced paresthesia. However, when auditory feedback confirmed successful aiming movements in Experiment 2, participants were able to improve their endpoint variability when experiencing induced paresthesia through changes in movement preparation.
- Open Access
- 9 December 2020
- Published by MDPI AG in Brain Sciences
- Vol. 10 (12) , 954
Somatosensory Integration and Masking of Complex Tactile Information: Peripheral and Cortical Contributions
Nerve paresthesia is a sensory impairment experienced in clinical conditions such as diabetes. Paresthesia may “mask” or “compete” with meaningful tactile information in the patient’s sensory environment. The two objectives of the present study were: (1) to determine if radiating paresthesia produces a peripheral mask, a central mask, or a combination; (2) to determine if a response competition experimental design reveals changes in somatosensory integration similar to a masking design. Experiment 1 assessed the degree of masking caused by induced radiating ulnar nerve paresthesia (a concurrent non-target stimulus) on a vibrotactile Morse code letter acquisition task using both behavioral and neurophysiological measures. Experiment 2 used a response competition design by moving the radiating paresthesia to the median nerve. This move shifted the concurrent non-target stimulus to a location spatially removed from the target stimuli. The task, behavioral and neurophysiological measures remained consistent. The induced paresthesia impacted letter acquisition differentially depending on the relative location of meaningful and non-meaningful stimulation. Paresthesia acted as a peripheral mask when presented to overlapping anatomical stimulation areas, and a central mask when presented at separate anatomical areas. These findings are discussed as they relate to masking, subcortical, and centripetal gating.
- 9 December 2020
- Published by MDPI AG in Brain Sciences
- Vol. 10 (12) , 954
Open AccessSomatosensory Integration and Masking of Complex Tactile Information: Peripheral and Cortical Contributions
Nerve paresthesia is a sensory impairment experienced in clinical conditions such as diabetes. Paresthesia may “mask” or “compete” with meaningful tactile information in the patient’s sensory environment. The two objectives of the present study were: (1) to determine if radiating paresthesia produces a peripheral mask, a central mask, or a combination; (2) to determine if a response competition experimental design reveals changes in somatosensory integration similar to a masking design. Experiment 1 assessed the degree of masking caused by induced radiating ulnar nerve paresthesia (a concurrent non-target stimulus) on a vibrotactile Morse code letter acquisition task using both behavioral and neurophysiological measures. Experiment 2 used a response competition design by moving the radiating paresthesia to the median nerve. This move shifted the concurrent non-target stimulus to a location spatially removed from the target stimuli. The task, behavioral and neurophysiological measures remained consistent. The induced paresthesia impacted letter acquisition differentially depending on the relative location of meaningful and non-meaningful stimulation. Paresthesia acted as a peripheral mask when presented to overlapping anatomical stimulation areas, and a central mask when presented at separate anatomical areas. These findings are discussed as they relate to masking, subcortical, and centripetal gating.
- 1 October 2019
- Published by Edizioni Minerva Medica in European Journal of Physical and Rehabilitation Medicine
- Vol. 55 (5) , 558-569
Upper limb tendon/muscle vibration in persons with subacute and chronic stroke: a systematic review and meta-analysis
Results of several recent studies suggest that tendon/muscle vibration treatment may improve motor performance and reduce spasticity in individuals with stroke. We performed a systematic review and meta-analysis to assess the efficacy of tendon/muscle vibration treatment for upper limb functional movements in persons with subacute and chronic stroke. We searched MEDLINE (Ovid), EMBASE (Ovid), and the Cochrane Central Register of Controlled Trials (Wiley) from inception to September 2017. We included randomized controlled trials comparing upper limb tendon/muscle vibration to sham treatment/rest or conventional interventions in persons with subacute and chronic stroke. Our primary outcome was upper limb functional movement at the end of the treatment period. We included eight trials, enrolling a total of 211 participants. We found insufficient evidence to support a benefit for upper limb functional movement (standard mean difference -0.32, 95% confidence interval (CI) -0.74 to 0.10, I2 25%, 6 trials, 135 participants). Movement time for reaching tasks significantly decreased after using tendon/muscle vibration (standard mean difference -1.20, 95% CI -2.05 to -0.35, I2 65%, 2 trials, 74 participants). We also found that tendon/muscle vibration was not associated with a significant reduction in spasticity (4 trials). Besides shorter movement time for reaching tasks, we did not identify evidence to support clinical improvement in upper limb functional movements after tendon/muscle vibration treatment in persons with subacute and chronic stroke. A small number of trials were identified; therefore, there is a need for larger, higher quality studies and to consider the clinical relevance of performance-based outcome measures that focus on time to complete a functional movement such as a reach.
- 1 October 2019
- Published by Edizioni Minerva Medica in European Journal of Physical and Rehabilitation Medicine
- Vol. 55 (5) , 558-569
Upper limb tendon/muscle vibration in persons with subacute and chronic stroke: a systematic review and meta-analysis
Results of several recent studies suggest that tendon/muscle vibration treatment may improve motor performance and reduce spasticity in individuals with stroke. We performed a systematic review and meta-analysis to assess the efficacy of tendon/muscle vibration treatment for upper limb functional movements in persons with subacute and chronic stroke. We searched MEDLINE (Ovid), EMBASE (Ovid), and the Cochrane Central Register of Controlled Trials (Wiley) from inception to September 2017. We included randomized controlled trials comparing upper limb tendon/muscle vibration to sham treatment/rest or conventional interventions in persons with subacute and chronic stroke. Our primary outcome was upper limb functional movement at the end of the treatment period. We included eight trials, enrolling a total of 211 participants. We found insufficient evidence to support a benefit for upper limb functional movement (standard mean difference -0.32, 95% confidence interval (CI) -0.74 to 0.10, I2 25%, 6 trials, 135 participants). Movement time for reaching tasks significantly decreased after using tendon/muscle vibration (standard mean difference -1.20, 95% CI -2.05 to -0.35, I2 65%, 2 trials, 74 participants). We also found that tendon/muscle vibration was not associated with a significant reduction in spasticity (4 trials). Besides shorter movement time for reaching tasks, we did not identify evidence to support clinical improvement in upper limb functional movements after tendon/muscle vibration treatment in persons with subacute and chronic stroke. A small number of trials were identified; therefore, there is a need for larger, higher quality studies and to consider the clinical relevance of performance-based outcome measures that focus on time to complete a functional movement such as a reach.
- 5 July 2019
- Published by Taylor & Francis in International Journal of Neuroscience
- Vol. 129 (11) , 1066-1075
Effects of training with a neuro-mechano stimulator rehabilitation bicycle on functional recovery and paired-reflex depression of the soleus in individuals with incomplete paralysis: a proof-of-principle study
Aim: The present study describes the training effects of a novel motorized bicycle-like device for individuals with incomplete spinal cord injury. Methods: Participants were five individuals with motor incomplete spinal cord injury (56 ± 7 years). Four of five participants received two 30-min sessions of training: one with, and one without, mechanical stimulation on the plantar surface of the foot; soleus paired H-reflex depression was examined before and after each session. Three of five participants received 24 sessions of 30-min of training (long-training). Following the long-training, balance, walking and spasticity improvements were assessed using validated clinical outcome measures, in addition to the H-reflex assessment. Results: One cycling session with mechanical stimulation yielded 14% and 32% more reflex depression in participants with moderate spasticity (n = 2/4). The same trend was not observed in non-spastic participants (n = 2/4). All participants who participated in the long-training had spasticity and showed reduced spasticity, improved walking speed, endurance and balance. Conclusions: Overall, participants with spasticity showed increased soleus H-reflex suppression after one training session with mechanical stimulation and reduced spasticity scores after long training. We interpret this as evidence that the training influenced both presynaptic and postsynaptic inhibitory mechanisms acting on soleus motoneurons. Therefore, this training has the potential to be a non-invasive complementary therapy to reduce spasticity after incomplete spinal cord injury. Trial registration: ClinicalTrials.gov identifier: NCT02554058.
- 5 July 2019
- Published by Taylor & Francis in International Journal of Neuroscience
- Vol. 129 (11) , 1066-1075
Effects of training with a neuro-mechano stimulator rehabilitation bicycle on functional recovery and paired-reflex depression of the soleus in individuals with incomplete paralysis: a proof-of-principle study
Aim: The present study describes the training effects of a novel motorized bicycle-like device for individuals with incomplete spinal cord injury. Methods: Participants were five individuals with motor incomplete spinal cord injury (56 ± 7 years). Four of five participants received two 30-min sessions of training: one with, and one without, mechanical stimulation on the plantar surface of the foot; soleus paired H-reflex depression was examined before and after each session. Three of five participants received 24 sessions of 30-min of training (long-training). Following the long-training, balance, walking and spasticity improvements were assessed using validated clinical outcome measures, in addition to the H-reflex assessment. Results: One cycling session with mechanical stimulation yielded 14% and 32% more reflex depression in participants with moderate spasticity (n = 2/4). The same trend was not observed in non-spastic participants (n = 2/4). All participants who participated in the long-training had spasticity and showed reduced spasticity, improved walking speed, endurance and balance. Conclusions: Overall, participants with spasticity showed increased soleus H-reflex suppression after one training session with mechanical stimulation and reduced spasticity scores after long training. We interpret this as evidence that the training influenced both presynaptic and postsynaptic inhibitory mechanisms acting on soleus motoneurons. Therefore, this training has the potential to be a non-invasive complementary therapy to reduce spasticity after incomplete spinal cord injury. Trial registration: ClinicalTrials.gov identifier: NCT02554058.
- Open Access
- 23 May 2013
- Published by Public Library of Science (PLoS) in PLOS ONE
- Vol. 8 (5) , e64308
Influence of Functional Knee Bracing on the Isokinetic and Functional Tests of Anterior Cruciate Ligament Deficient Patients
Use of functional knee braces has been suggested to provide protection and to improve kinetic performance of the knee in Anterior cruciate ligament(ACL)-injured patients. However, many athletes might refrain from wearing the braces because of the fear of performance hindrance in the playing field. The aim of this study was to examine the effect of three functional knee brace/sleeves upon the isokinetic and functional performance of ACL-deficient and healthy subjects. Six anterior cruciate ligament deficient (29.0±5.3 yrs., 175.2±5.4 cm, and 73.0±10.0 kg) and six healthy male subjects (27.2±3.7 yrs., 176.4±6.4 cm, and 70.3±6.9 kg) were selected. The effect of a custom-made functional knee brace, and two neoprene knee sleeves, one with four metal supports and one without support were examined via the use of isokinetic and functional tests in four sets (non-braced,wearing functional knee brace,and wearing the sleeves). Cross-over hop and single leg vertical jump test were performed and jump height, and hop distance were recorded. Peak torque to body weight ratio and average power in two isokinetic velocities(60°.s−1,180°.s−1) were recorded and the brace/sleeves effect was calculated as the changes in peak torque measured in the brace/sleeves conditions, expressed as a percentage of peak torque measured in non-braced condition. Frequency content of the isokinetic torque-time curves was also analyzed. Wilcoxon signed rank test was used to compare the measured values in four test conditions within each control and ACL-deficient group,and Mann-Whitney U test was used for the comparison between the two groups. No significant differences in peak torque, average power, torque-time curve frequency content, vertical-jump and hop measurements were found within the experimental and the non-braced conditions (p>0.05). Although the examined functional knee brace/sleeves had no significant effect on the knee muscle performance, there have been some enhancement regarding the extension peak torques and power generating capacity of the ACL-deficient subjects that could be helpful in reducing the bilateral asymmetry in these patients.
- 23 May 2013
- Published by Public Library of Science (PLoS) in PLOS ONE
- Vol. 8 (5) , e64308
Open AccessInfluence of Functional Knee Bracing on the Isokinetic and Functional Tests of Anterior Cruciate Ligament Deficient Patients
Use of functional knee braces has been suggested to provide protection and to improve kinetic performance of the knee in Anterior cruciate ligament(ACL)-injured patients. However, many athletes might refrain from wearing the braces because of the fear of performance hindrance in the playing field. The aim of this study was to examine the effect of three functional knee brace/sleeves upon the isokinetic and functional performance of ACL-deficient and healthy subjects. Six anterior cruciate ligament deficient (29.0±5.3 yrs., 175.2±5.4 cm, and 73.0±10.0 kg) and six healthy male subjects (27.2±3.7 yrs., 176.4±6.4 cm, and 70.3±6.9 kg) were selected. The effect of a custom-made functional knee brace, and two neoprene knee sleeves, one with four metal supports and one without support were examined via the use of isokinetic and functional tests in four sets (non-braced,wearing functional knee brace,and wearing the sleeves). Cross-over hop and single leg vertical jump test were performed and jump height, and hop distance were recorded. Peak torque to body weight ratio and average power in two isokinetic velocities(60°.s−1,180°.s−1) were recorded and the brace/sleeves effect was calculated as the changes in peak torque measured in the brace/sleeves conditions, expressed as a percentage of peak torque measured in non-braced condition. Frequency content of the isokinetic torque-time curves was also analyzed. Wilcoxon signed rank test was used to compare the measured values in four test conditions within each control and ACL-deficient group,and Mann-Whitney U test was used for the comparison between the two groups. No significant differences in peak torque, average power, torque-time curve frequency content, vertical-jump and hop measurements were found within the experimental and the non-braced conditions (p>0.05). Although the examined functional knee brace/sleeves had no significant effect on the knee muscle performance, there have been some enhancement regarding the extension peak torques and power generating capacity of the ACL-deficient subjects that could be helpful in reducing the bilateral asymmetry in these patients.
- Open Access
- 21 November 2012
- Published by Public Library of Science (PLoS) in PLOS ONE
- Vol. 7 (11) , e50110
The Effects of a Prophylactic Knee Brace and Two Neoprene Knee Sleeves on the Performance of Healthy Athletes: A Crossover Randomized Controlled Trial
Knee injury is one of the major problems in sports medicine, and the use of prophylactic knee braces is an attempt to reduce the occurrence and/or severity of injuries to the knee joint ligament(s) without inhibiting knee mobility. The aim of the present study was to examine the effect of one recently designed prophylactic knee brace and two neoprene knee sleeves upon performance of healthy athletes. Thirty-one healthy male athletes (age = 21.2±1.5) volunteered as participants to examine the effect of prophylactic knee brace/sleeves on performance using isokinetic and functional tests. All subjects were tested in four conditions in a random order: 1. nonbraced (control) 2. using a neoprene knee sleeve 3. using a knee sleeve with four bilateral metal supports and 4. using a prophylactic knee brace. The study design was a crossover, randomized, controlled trial. Subjects completed single leg vertical jump, cross-over hop, and the isokinetic knee flexion and extension (at 60, 180, 300°/sec). Data were collected from the above tests and analyzed for jump height, cross-over hop distance, peak torque to body weight ratio and average power, respectively. Comparisons of these variables in the four testing conditions revealed no statistically significant difference (p>0.05). The selected prophylactic brace/sleeves did not significantly inhibit athletic performance which might verify that their structure and design have caused no complication in the normal function of the knee joint. Moreover, it could be speculated that, if the brace or the sleeves had any limiting effect, our young healthy athletic subjects were well able to generate a mean peak torque large enough to overcome this possible restriction. Further studies are suggested to investigate the long term effect of these prophylactic knee brace and sleeves as well as their possible effect on the adjacent joints to the knee.
- 21 November 2012
- Published by Public Library of Science (PLoS) in PLOS ONE
- Vol. 7 (11) , e50110
Open AccessThe Effects of a Prophylactic Knee Brace and Two Neoprene Knee Sleeves on the Performance of Healthy Athletes: A Crossover Randomized Controlled Trial
Knee injury is one of the major problems in sports medicine, and the use of prophylactic knee braces is an attempt to reduce the occurrence and/or severity of injuries to the knee joint ligament(s) without inhibiting knee mobility. The aim of the present study was to examine the effect of one recently designed prophylactic knee brace and two neoprene knee sleeves upon performance of healthy athletes. Thirty-one healthy male athletes (age = 21.2±1.5) volunteered as participants to examine the effect of prophylactic knee brace/sleeves on performance using isokinetic and functional tests. All subjects were tested in four conditions in a random order: 1. nonbraced (control) 2. using a neoprene knee sleeve 3. using a knee sleeve with four bilateral metal supports and 4. using a prophylactic knee brace. The study design was a crossover, randomized, controlled trial. Subjects completed single leg vertical jump, cross-over hop, and the isokinetic knee flexion and extension (at 60, 180, 300°/sec). Data were collected from the above tests and analyzed for jump height, cross-over hop distance, peak torque to body weight ratio and average power, respectively. Comparisons of these variables in the four testing conditions revealed no statistically significant difference (p>0.05). The selected prophylactic brace/sleeves did not significantly inhibit athletic performance which might verify that their structure and design have caused no complication in the normal function of the knee joint. Moreover, it could be speculated that, if the brace or the sleeves had any limiting effect, our young healthy athletic subjects were well able to generate a mean peak torque large enough to overcome this possible restriction. Further studies are suggested to investigate the long term effect of these prophylactic knee brace and sleeves as well as their possible effect on the adjacent joints to the knee.
- 1 November 2012
- Published by Elsevier in Clinical Biomechanics
- Vol. 27 (9) , 943-948
Clinical investigation of the interface pressure in the trans-tibial socket with Dermo and Seal-In X5 liner during walking and their effect on patient satisfaction
- 1 November 2012
- Published by Elsevier in Clinical Biomechanics
- Vol. 27 (9) , 943-948
Clinical investigation of the interface pressure in the trans-tibial socket with Dermo and Seal-In X5 liner during walking and their effect on patient satisfaction
- 1 November 2010
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-4
Designing and fabrication of a Postural Stabilometer: A static platform
In this paper, designing and fabrication of a static Postural Stabilometer is described. The hardware and software implementation of the instrument is briefly reported. Sensors, hardware circuit, filter and A/D converter is presented in hardware section. Forces estimation, center of pressure (COP) position and sway index is stated in software section. Finally, the overall instrument is tested on several healthy subjects and their reports are presented in detail.
- 1 November 2010
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-4
Designing and fabrication of a Postural Stabilometer: A static platform
In this paper, designing and fabrication of a static Postural Stabilometer is described. The hardware and software implementation of the instrument is briefly reported. Sensors, hardware circuit, filter and A/D converter is presented in hardware section. Forces estimation, center of pressure (COP) position and sway index is stated in software section. Finally, the overall instrument is tested on several healthy subjects and their reports are presented in detail.