Nasser G. A. Hemdan
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Nasser G. A. Hemdan has a total of 16 co-authors. Here are the top co-authors by number of shared publications:
Michael Kurrat
7 shared publicationsM. Kurrat
3 shared publicationsMohamed M. Hamada
Electrical Engineering Department, Faculty of Engineering, Minia University, Egypt
3 shared publicationsTanja Schmedes
EWE AG, EWE NETZ, Oldenburg, Germany
3 shared publicationsBenjamin Deppe
Soluvia Metering GmbH, Offenbach, Germany
2 shared publicationsEnno Wieben
EWE AG, EWE NETZ, Oldenburg, Germany
2 shared publications
Latest Publications
- Top Cited Papers
- 1 April 2017
- Published by Elsevier in Renewable and Sustainable Energy Reviews
- Vol. 70, 427-456
Challenges and opportunities for a European HVDC grid
- 1 April 2017
- Published by Elsevier in Renewable and Sustainable Energy Reviews
- Vol. 70, 427-456
Top Cited PapersChallenges and opportunities for a European HVDC grid
- 2 February 2017
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 837-842
Coordinated reactive power management in distribution networks with renewable energy resources
Due to increasing penetration level of renewable energy based Distributed Generation (DG), voltage/reactive power control in distribution networks is currently an important topic. This paper proposes two coordinated voltage/reactive power control approaches in active distribution grids. The proposed coordination control is achieved based on predefined procedures to increase speed response and to reduce the complexity of computations. Simulations were carried out on a realistic Medium Voltage (MV) network using measured data of DG output power. The results were taken for different three weeks in the year representing different seasons. The results of the proposed approach were compared with previously published centralized control approach. The results indicate that the proposed approaches reduce the number of OLTC operations, reduce system losses, minimize the voltage fluctuation in the distribution system, and increase the hosting capacity of DG power.
- 2 February 2017
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 837-842
Coordinated reactive power management in distribution networks with renewable energy resources
Due to increasing penetration level of renewable energy based Distributed Generation (DG), voltage/reactive power control in distribution networks is currently an important topic. This paper proposes two coordinated voltage/reactive power control approaches in active distribution grids. The proposed coordination control is achieved based on predefined procedures to increase speed response and to reduce the complexity of computations. Simulations were carried out on a realistic Medium Voltage (MV) network using measured data of DG output power. The results were taken for different three weeks in the year representing different seasons. The results of the proposed approach were compared with previously published centralized control approach. The results indicate that the proposed approaches reduce the number of OLTC operations, reduce system losses, minimize the voltage fluctuation in the distribution system, and increase the hosting capacity of DG power.
- 1 June 2015
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-6
Switching state optimization influences on active distribution systems operation
In the current work the implications of distribution networks reconfiguration on the system operation were investigated. Different technical issues such as voltage profiles, line loading, and On-Load Tap Changer (OLTC) were tested through the switching state optimization of the network. The simulations were conducted based on load and renewable energy based generation profiles. Different day types in different seasons were simulated. A comparison between switching optimization of the network one time per day and hourly switching was also performed. The results show that the voltage profiles will be improved. Moreover, the bottlenecks in the lines can be released. Optimization of the switching state for one time per day can be better than switching in an hourly scheme.
- 1 June 2015
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-6
Switching state optimization influences on active distribution systems operation
In the current work the implications of distribution networks reconfiguration on the system operation were investigated. Different technical issues such as voltage profiles, line loading, and On-Load Tap Changer (OLTC) were tested through the switching state optimization of the network. The simulations were conducted based on load and renewable energy based generation profiles. Different day types in different seasons were simulated. A comparison between switching optimization of the network one time per day and hourly switching was also performed. The results show that the voltage profiles will be improved. Moreover, the bottlenecks in the lines can be released. Optimization of the switching state for one time per day can be better than switching in an hourly scheme.
- 1 November 2014
- Published by Elsevier in Electric Power Systems Research
- Vol. 116, 355-366
Optimal reconfiguration of radial MV networks with load profiles in the presence of renewable energy based decentralized generation
- 1 November 2014
- Published by Elsevier in Electric Power Systems Research
- Vol. 116, 355-366
Optimal reconfiguration of radial MV networks with load profiles in the presence of renewable energy based decentralized generation
- 1 January 2013
- Published by Institution of Engineering and Technology (IET)
- p. 1293
Reactive power concepts in the future distribution networks
- 1 January 2013
- Published by Institution of Engineering and Technology (IET)
- p. 1293
Reactive power concepts in the future distribution networks
- 1 November 2011
- Published by Elsevier in International Journal of Electrical Power & Energy Systems
- Vol. 33 (9) , 1572-1583
Efficient integration of distributed generation for meeting the increased load demand
- 1 November 2011
- Published by Elsevier in International Journal of Electrical Power & Energy Systems
- Vol. 33 (9) , 1572-1583
Efficient integration of distributed generation for meeting the increased load demand
- 17 March 2011
- Published by Elsevier in Electric Power Systems Research
- Vol. 81 (7) , 1410-1423
Interconnection of decentralized renewable resources into distribution grids: Implications and planning aspects
- 17 March 2011
- Published by Elsevier in Electric Power Systems Research
- Vol. 81 (7) , 1410-1423
Interconnection of decentralized renewable resources into distribution grids: Implications and planning aspects
- 1 July 2010
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- No. 19325517,p. 1-8
Effect of integration of Distributed Wind Generation into a real MV distribution network: A case study using measured wind data and simulated load profiles
The interest in the integration of distributed generation into distribution systems has been increased in different countries all over the world as economic and environmental factors drive new technologies to be more efficient and less polluting than their earlier counterparts. As the penetration level of DG increases, the distribution system performance has to be analyzed in details. This work investigates the effects of Distributed Wind Generation (DWG) on voltage ranges, voltage profiles, and system MWh losses of a real MV distribution network. The availability to integrate a new wind mill into the system that already contains three wind mills is examined with respect to the technical conditions for generation connection to the MV networks introduced by German Energy and Water Federation. In the simulation, we used a one year measured wind data and simulated load profiles of the households which are connected to the LV side at each MV substation.
- 1 July 2010
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- No. 19325517,p. 1-8
Effect of integration of Distributed Wind Generation into a real MV distribution network: A case study using measured wind data and simulated load profiles
The interest in the integration of distributed generation into distribution systems has been increased in different countries all over the world as economic and environmental factors drive new technologies to be more efficient and less polluting than their earlier counterparts. As the penetration level of DG increases, the distribution system performance has to be analyzed in details. This work investigates the effects of Distributed Wind Generation (DWG) on voltage ranges, voltage profiles, and system MWh losses of a real MV distribution network. The availability to integrate a new wind mill into the system that already contains three wind mills is examined with respect to the technical conditions for generation connection to the MV networks introduced by German Energy and Water Federation. In the simulation, we used a one year measured wind data and simulated load profiles of the households which are connected to the LV side at each MV substation.
- 1 February 2010
- Published by Elsevier in Electric Power Systems Research
- Vol. 80 (2) , 152-160
Simple and efficient method for steady-state voltage stability assessment of radial distribution systems
- 1 February 2010
- Published by Elsevier in Electric Power Systems Research
- Vol. 80 (2) , 152-160
Simple and efficient method for steady-state voltage stability assessment of radial distribution systems