Antonio Carlos Oliveira Bruno
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Antonio Carlos Oliveira Bruno has a total of 38 co-authors. Here are the top co-authors by number of shared publications:
- Cleanio Luz Lima
Department of Physics, Federal University of Piauí, Teresina 64049-550, PI, Brazil
2 shared publications - Jefferson Ferraz Damasceno Felix Araujo
Pontifícia Universidade Católica do Rio de Janeiro, Brasil
2 shared publications - André Luis Albuquerque dos Reis
Observatório Nacional - ON, Rio de Janeiro
1 shared publication - Arthur Martins Barbosa Braga
Pontifical Catholic University of Rio de Janeiro
1 shared publication C.S. Franco
Departamento de Física, Pontifícia Universidade Católica do Rio de Janeiro, Rua Marquês de São Vicente 225, 22451-900 Rio de Janeiro, RJ, Brazil
1 shared publicationCaique D.A. Lima
1 shared publication
Latest Publications
- Open Access
Measuring Iron Oxide Composites with a Custom-Made Scanning Magnetic Microscope
We improved a scanning magnetic microscope built previously by adding a new detection system and the capability of mapping samples applying magnetic fields from −500 mT to +500 mT. The mechanical structure was also enhanced to decrease vibrations of the system in the earth’s magnetic field. The microscope is based on a differential arrangement of two Hall effect elements. The overall system presented a sensitivity of about 850 , and it was calibrated using a 99% pure nickel sphere. The system achieved a magnetic moment sensitivity of the order of 10 nAm2. All equipment used for operating the magnetic microscope was controlled by using the LabVIEW® platform. We also fabricated samples with controlled properties using iron oxide microparticles and epoxy resin with various densities. We obtained the magnetization curves of the composites using the assembled microscope and compared them with the iron oxide powder.Open AccessMeasuring Iron Oxide Composites with a Custom-Made Scanning Magnetic Microscope
We improved a scanning magnetic microscope built previously by adding a new detection system and the capability of mapping samples applying magnetic fields from −500 mT to +500 mT. The mechanical structure was also enhanced to decrease vibrations of the system in the earth’s magnetic field. The microscope is based on a differential arrangement of two Hall effect elements. The overall system presented a sensitivity of about 850 , and it was calibrated using a 99% pure nickel sphere. The system achieved a magnetic moment sensitivity of the order of 10 nAm2. All equipment used for operating the magnetic microscope was controlled by using the LabVIEW® platform. We also fabricated samples with controlled properties using iron oxide microparticles and epoxy resin with various densities. We obtained the magnetization curves of the composites using the assembled microscope and compared them with the iron oxide powder. - Open Access
Fabry–Perot Cavity Optimization for Absolute Strain Sensing Using Finite Element Analysis
The finite element method (FEM) was used to investigate the optical–mechanical behavior of a Fabry–Perot Interferometer (FPI) composed of a capillary segment spliced between two sections of standard optical fiber. The developed FEM model was validated by comparing it with theory and with previously published experimental data. The model was then used to show that the absolute strain on the host substrate is usually smaller than the strain measurement obtained with the sensor. Finally, the FEM model was used to propose a cavity geometry that can be produced with repeatability and that yields the correct absolute strain experienced by the host substrate, without requiring previous strain calibration.
Open AccessFabry–Perot Cavity Optimization for Absolute Strain Sensing Using Finite Element Analysis
The finite element method (FEM) was used to investigate the optical–mechanical behavior of a Fabry–Perot Interferometer (FPI) composed of a capillary segment spliced between two sections of standard optical fiber. The developed FEM model was validated by comparing it with theory and with previously published experimental data. The model was then used to show that the absolute strain on the host substrate is usually smaller than the strain measurement obtained with the sensor. Finally, the FEM model was used to propose a cavity geometry that can be produced with repeatability and that yields the correct absolute strain experienced by the host substrate, without requiring previous strain calibration.
- 23 April 2022
- Published by Elsevier in Ceramics International
- Vol. 48 (15) , 21690-21699
Spinel nanoparticles characterization by inverting scanning magnetic microscope maps
- 23 April 2022
- Published by Elsevier in Ceramics International
- Vol. 48 (15) , 21690-21699
Spinel nanoparticles characterization by inverting scanning magnetic microscope maps
- 29 January 2022
- Published by Springer Nature in Brazilian Journal of Physics
- Vol. 52 (2) , 1-10
SQUID and Hall Effect Magnetometers for Detecting and Characterizing Nanoparticles Used in Biomedical Applications
- 29 January 2022
- Published by Springer Nature in Brazilian Journal of Physics
- Vol. 52 (2) , 1-10
SQUID and Hall Effect Magnetometers for Detecting and Characterizing Nanoparticles Used in Biomedical Applications
- 1 June 2018
- Published by Elsevier in Journal of Magnetism and Magnetic Materials
- Vol. 456, 346-352
Magnetic evaluation of the external surface in cast heat-resistant steel tubes with different aging states
- 1 June 2018
- Published by Elsevier in Journal of Magnetism and Magnetic Materials
- Vol. 456, 346-352
Magnetic evaluation of the external surface in cast heat-resistant steel tubes with different aging states
- 6 June 2006
- Published by Elsevier in Sensors and Actuators A: Physical
- Vol. 132 (1) , 85-89
Influence of the anisotropy axis direction and ribbon geometry on the giant magnetoimpedance of Metglas® 2705M
- 6 June 2006
- Published by Elsevier in Sensors and Actuators A: Physical
- Vol. 132 (1) , 85-89
Influence of the anisotropy axis direction and ribbon geometry on the giant magnetoimpedance of Metglas® 2705M
- 1 January 1998
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Magnetics
- Vol. 34 (5) , 2912-2915
Image reconstruction of spherical inclusions in ferromagnetic structures using the generalized inverse
The generalized inverse method and singular value decomposition were used to reconstruct the magnetic image of small spherical inclusions in ferromagnetic structures. These techniques were used on the magnetic flux leakage generated when the structure is magnetized. The leakage field from the inclusions was simulated by using a simple constant-permeability model. The recovery model used a grid of magnetic dipoles at the region of the inclusions. The ability of the technique to distinguish between different distributions of inclusions with similar leakage fields is analyzed. The results demonstrates the feasibility of imaging multiple inclusions within the structure.
- 1 January 1998
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Magnetics
- Vol. 34 (5) , 2912-2915
Image reconstruction of spherical inclusions in ferromagnetic structures using the generalized inverse
The generalized inverse method and singular value decomposition were used to reconstruct the magnetic image of small spherical inclusions in ferromagnetic structures. These techniques were used on the magnetic flux leakage generated when the structure is magnetized. The leakage field from the inclusions was simulated by using a simple constant-permeability model. The recovery model used a grid of magnetic dipoles at the region of the inclusions. The ability of the technique to distinguish between different distributions of inclusions with similar leakage fields is analyzed. The results demonstrates the feasibility of imaging multiple inclusions within the structure.
- 1 October 1992
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- Vol. 5, 2174-2175
Representations of isocontours on a spherical head
A visualization technique was developed to generate and display magnetic field isocontours on a wireframe spherical head model. The data are obtained by simulated measurements of the magnetic field generated by a set of neuronal sources. This presentation is particulary useful for displaying widespread activity.
- 1 October 1992
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- Vol. 5, 2174-2175
Representations of isocontours on a spherical head
A visualization technique was developed to generate and display magnetic field isocontours on a wireframe spherical head model. The data are obtained by simulated measurements of the magnetic field generated by a set of neuronal sources. This presentation is particulary useful for displaying widespread activity.
- 1 April 1991
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 62 (4) , 1005-1009
Spatial Fourier calibration method for multichannel SQUID magnetometers
When using multichannel SQUID magnetometers for biomagnetic applications, the correct measurement of the Tesla/volt calibration factor of each channel is of extreme importance, in order to avoid gross errors when analyzing the results. We propose a general calibration method valid for all kinds of gradiometer arrays. One of the main properties of this method is that the gradiometer position inside the cryogenic Dewar does not need to be known precisely. When tested, calibration factors with accuracies ranging from 0.3% to 0.8% were obtained. It is based on a spatial Fourier technique and on the fact that the gradiometer acts as a discrete spatial filter.
- 1 April 1991
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 62 (4) , 1005-1009
Spatial Fourier calibration method for multichannel SQUID magnetometers
When using multichannel SQUID magnetometers for biomagnetic applications, the correct measurement of the Tesla/volt calibration factor of each channel is of extreme importance, in order to avoid gross errors when analyzing the results. We propose a general calibration method valid for all kinds of gradiometer arrays. One of the main properties of this method is that the gradiometer position inside the cryogenic Dewar does not need to be known precisely. When tested, calibration factors with accuracies ranging from 0.3% to 0.8% were obtained. It is based on a spatial Fourier technique and on the fact that the gradiometer acts as a discrete spatial filter.