Giovanni Margutti
Giovanni Margutti has a total of 249 co-authors. Here are the top co-authors by number of shared publications:
C. Bacci
Dipartimento di Fisica and INFN, Roma III, Italy
6 shared publicationsF. Ceradini
Dipartimento di Fisica and INFN, Roma III, Italy
6 shared publicationsF. Lacava
Dipartimento di Fisica and INFN, Roma I, Italy
6 shared publicationsL. Pontecorvo
Dipartimento di Fisica and INFN, Roma I, Italy
6 shared publications- Stefano Veneziano
INFN Sezione di Roma
6 shared publications - Giuseppe Finocchiaro
INFN Laboratori Nazionali di Frascati
5 shared publications
Latest Publications
- Open Access
- 1 July 2024
- Published by IOP Publishing in Journal of Instrumentation
- Vol. 19 (07) , P07033
First results on monolithic CMOS detector with internal gain
In this paper we report on a set of characterisations carried out on the first monolithic LGAD prototype integrated in a customised 110 nm CMOS process having a depleted active volume thickness of 48 μm. This prototype is formed by a pixel array where each pixel has a total size of 100 μm× 250 μm and includes a high-speed front-end amplifier. After describing the sensor and the electronics architecture, both laboratory and in-beam measurements are reported and described. Optical characterisations performed with an IR pulsed laser setup have shown a sensor internal gain of about 2.5. With the same experimental setup, the electronic jitter was found to be between 50 ps and 150 ps, depending on the signal amplitude. Moreover, the analysis of a test beam performed at the Proton Synchrotron (PS) T10 facility of CERN with 10 GeV/c protons and pions indicated that the overall detector time resolution is in the range of 234 ps to 244 ps. Further TCAD investigations, based on the doping profile extracted from C(V) measurements, confirmed the multiplication gain measured on the test devices. Finally, TCAD simulations were used to tune the future doping concentration of the gain layer implant, targeting sensors with a higher avalanche gain. This adjustment is expected to enhance the timing performance of the sensors of the future productions, in order to cope with the high event rate expected in most of the near future high-energy and high-luminosity physics experiments, where the time resolution will be essential to disentangle overlapping events and it will also be crucial for Particle IDentification (PID).
- 1 July 2024
- Published by IOP Publishing in Journal of Instrumentation
- Vol. 19 (07) , P07033
Open AccessFirst results on monolithic CMOS detector with internal gain
In this paper we report on a set of characterisations carried out on the first monolithic LGAD prototype integrated in a customised 110 nm CMOS process having a depleted active volume thickness of 48 μm. This prototype is formed by a pixel array where each pixel has a total size of 100 μm× 250 μm and includes a high-speed front-end amplifier. After describing the sensor and the electronics architecture, both laboratory and in-beam measurements are reported and described. Optical characterisations performed with an IR pulsed laser setup have shown a sensor internal gain of about 2.5. With the same experimental setup, the electronic jitter was found to be between 50 ps and 150 ps, depending on the signal amplitude. Moreover, the analysis of a test beam performed at the Proton Synchrotron (PS) T10 facility of CERN with 10 GeV/c protons and pions indicated that the overall detector time resolution is in the range of 234 ps to 244 ps. Further TCAD investigations, based on the doping profile extracted from C(V) measurements, confirmed the multiplication gain measured on the test devices. Finally, TCAD simulations were used to tune the future doping concentration of the gain layer implant, targeting sensors with a higher avalanche gain. This adjustment is expected to enhance the timing performance of the sensors of the future productions, in order to cope with the high event rate expected in most of the near future high-energy and high-luminosity physics experiments, where the time resolution will be essential to disentangle overlapping events and it will also be crucial for Particle IDentification (PID).
- 21 April 2020
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Electron Devices
- Vol. 67 (6) , 2393-2399
Fully Depleted MAPS in 110-nm CMOS Process With 100–300-μm Active Substrate
This article presents a fully depleted monolithic active pixel sensor technology compatible with a standard deep submicrometer 110-nm CMOS process. Passive test pixels structures, produced in various flavors, have proved the feasibility of 100- and 300-μm-thick active substrates. Active pixel sensors with monolithically integrated analog and digital electronics, consisting of a 24 x 24 array of pixels with 50-μm pitch, have been shown to be fully functional when operating in the full depletion mode. Characterization results obtained with a proton microbeam and a ⁵⁵Fe radiation source are presented and discussed.
- 21 April 2020
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Electron Devices
- Vol. 67 (6) , 2393-2399
Fully Depleted MAPS in 110-nm CMOS Process With 100–300-μm Active Substrate
This article presents a fully depleted monolithic active pixel sensor technology compatible with a standard deep submicrometer 110-nm CMOS process. Passive test pixels structures, produced in various flavors, have proved the feasibility of 100- and 300-μm-thick active substrates. Active pixel sensors with monolithically integrated analog and digital electronics, consisting of a 24 x 24 array of pixels with 50-μm pitch, have been shown to be fully functional when operating in the full depletion mode. Characterization results obtained with a proton microbeam and a ⁵⁵Fe radiation source are presented and discussed.
- 1 December 2015
- Published by Elsevier in Nuclear Instruments and Methods in Physics Research Section B: Beam Interactions with Materials and Atoms
- Vol. 365, 283-287
Silicon defects characterization for low temperature ion implantation and RTA process
- 1 December 2015
- Published by Elsevier in Nuclear Instruments and Methods in Physics Research Section B: Beam Interactions with Materials and Atoms
- Vol. 365, 283-287
Silicon defects characterization for low temperature ion implantation and RTA process
- 1 August 2014
- Published by Elsevier in Microelectronic Engineering
- Vol. 125, 51-57
Optimization of laser anneal conditions for implanted shallow p/n-junctions
- 1 August 2014
- Published by Elsevier in Microelectronic Engineering
- Vol. 125, 51-57
Optimization of laser anneal conditions for implanted shallow p/n-junctions
- 1 June 2014
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-4
Silicon defects characterization for low temperature ion implantation and spike anneal processes
In the last years a lot of effort has been directed in order to reduce ion implantation damage, which can be detrimental for silicon device performances. Implantation's dose rate and temperature were found to be two important factors to modulate residual damage left in silicon after anneal. In this work high dose rate, low temperature, high dose arsenic and boron implantations are compared to the corresponding low dose rate, room temperature processes in terms of silicon lattice defectiveness and dopant distribution, before and after anneal is performed. The considered implant processes are the one typically used to form a source/drain region in a CMOS process flow in the submicron technology node. A spike anneal process was applied to activate the dopant. Low temperature, high dose rate implantations have found to be effective in reducing silicon extended defects with a negligible effect on the profile of the activated dopant. Experimental set up, results and possible explanation will be reported and discussed in the paper.
- 1 June 2014
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-4
Silicon defects characterization for low temperature ion implantation and spike anneal processes
In the last years a lot of effort has been directed in order to reduce ion implantation damage, which can be detrimental for silicon device performances. Implantation's dose rate and temperature were found to be two important factors to modulate residual damage left in silicon after anneal. In this work high dose rate, low temperature, high dose arsenic and boron implantations are compared to the corresponding low dose rate, room temperature processes in terms of silicon lattice defectiveness and dopant distribution, before and after anneal is performed. The considered implant processes are the one typically used to form a source/drain region in a CMOS process flow in the submicron technology node. A spike anneal process was applied to activate the dopant. Low temperature, high dose rate implantations have found to be effective in reducing silicon extended defects with a negligible effect on the profile of the activated dopant. Experimental set up, results and possible explanation will be reported and discussed in the paper.
- 1 July 2000
- Published by Elsevier in Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment
- Vol. 449 (1-2) , 237-247
Test of a small prototype of the KLOE drift chamber in magnetic field
- 1 July 2000
- Published by Elsevier in Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment
- Vol. 449 (1-2) , 237-247
Test of a small prototype of the KLOE drift chamber in magnetic field
- 27 August 1998
- Published by SPIE-Intl Soc Optical Eng
- p. 221-227
TOF-SIMS: a tool for material characterization, process control, and improvement in a wafer fab
- 27 August 1998
- Published by SPIE-Intl Soc Optical Eng
- p. 221-227
TOF-SIMS: a tool for material characterization, process control, and improvement in a wafer fab
- 1 February 1998
- Published by Elsevier in Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment
- Vol. 404 (2) , 248-264
The full-length prototype of the KLOE drift chamber
- 1 February 1998
- Published by Elsevier in Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment
- Vol. 404 (2) , 248-264
The full-length prototype of the KLOE drift chamber
- Open Access
- 1 February 1997
- Published by Elsevier in Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment
- Vol. 386 (2-3) , 421-430
Measurement of momentum and angular distribution of punchthrough muons at the RD5 experiment
- 1 February 1997
- Published by Elsevier in Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment
- Vol. 386 (2-3) , 421-430
Open AccessMeasurement of momentum and angular distribution of punchthrough muons at the RD5 experiment