Eduardo Suarez
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Eduardo Suarez has a total of 47 co-authors. Here are the top co-authors by number of shared publications:
- Concepción Paz
Universidade de Vigo
21 shared publications - Christian Gil
Universidade de Vigo
13 shared publications C. Paz
9 shared publications- Jacobo Porteiro
Grupo de Tecnología Energética (GTE), CINTEX, Universidade de Vigo, 36310 Vigo, Pontevedra, Spain
8 shared publications - Miguel Concheiro
University of Vigo
8 shared publications - Jesús Vence
A School of Industrial Engineering , University of Vigo , Vigo , Spain
6 shared publications
Latest Publications
- 16 January 2026
- Published by Elsevier in International Journal of Non-Linear Mechanics
- Vol. 183-184
Analysis of arterial wall mechanics in right coronary artery obstructive disease: FSI modelling and non-invasive FFR validation
- 16 January 2026
- Published by Elsevier in International Journal of Non-Linear Mechanics
- Vol. 183-184
Analysis of arterial wall mechanics in right coronary artery obstructive disease: FSI modelling and non-invasive FFR validation
- Open Access
- 17 November 2025
- Published by Springer Nature in Scientific Reports
- Vol. 15 (1) , 40315
Experimental verification and comparative analysis of peak expiratory flow measuring devices
This study presents a comprehensive benchmarking of six commercially available peak expiratory flow meters (PFMs), using a precise experimental spirometric test bench. Eight peak expiratory flows (PEF) ranging from 59.40 to 688.80 L/min at three frequencies, were systematically applied to each device. Through a series of controlled tests, the devices’ precision, accuracy, linearity, inter-device variability, and dynamic response were meticulously evaluated across their full measurement range. Results reveal distinct performance characteristics among models, with some demonstrating high precision and accuracy in intermediate flow ranges, whereas others exhibited significant deviations at lower or higher flows. Inter-device variability was minimal except for specific models at lower flow rates. Dynamic response at varying frequencies indicated negligible impact on device readings. This benchmarking provides valuable insights for clinicians and researchers selecting appropriate PFMs for respiratory assessments.
- 17 November 2025
- Published by Springer Nature in Scientific Reports
- Vol. 15 (1) , 40315
Open AccessExperimental verification and comparative analysis of peak expiratory flow measuring devices
This study presents a comprehensive benchmarking of six commercially available peak expiratory flow meters (PFMs), using a precise experimental spirometric test bench. Eight peak expiratory flows (PEF) ranging from 59.40 to 688.80 L/min at three frequencies, were systematically applied to each device. Through a series of controlled tests, the devices’ precision, accuracy, linearity, inter-device variability, and dynamic response were meticulously evaluated across their full measurement range. Results reveal distinct performance characteristics among models, with some demonstrating high precision and accuracy in intermediate flow ranges, whereas others exhibited significant deviations at lower or higher flows. Inter-device variability was minimal except for specific models at lower flow rates. Dynamic response at varying frequencies indicated negligible impact on device readings. This benchmarking provides valuable insights for clinicians and researchers selecting appropriate PFMs for respiratory assessments.
- Open Access
- 27 August 2025
- Published by Springer Nature in Scientific Reports
- Vol. 15 (1) , 1-12
Numerical simulation of transcranial static magnetic fields for the treatment of global epilepsy in children
Transcranial static magnetic stimulation has shown the capacity to decrease systematically the cortical excitability in the treatment of epilepsy. Nevertheless, the application of these therapies to non-focal epilepsies is limited. This paper investigates on the numerical evaluation of promising strategies based on the application of static magnetic fields with multiple magnets on children. Results show that a ten-magnet configuration on the child’s head generates a magnetic flux density of 0.10 T in more than 70% of the brain cortex and more than 0.05 T in deep areas near the brain’s base. Conversely, the interaction between individual magnetic fields leads to regions of lower flux density, suggesting that not only the number of magnets, but also their relative position and orientation, are critical parameters. Thus, based on image diagnosis, it is possible to define a personalising procedure and develop an effective therapy of global epilepsy that penetrates sufficiently into the brain´s volume.
- 27 August 2025
- Published by Springer Nature in Scientific Reports
- Vol. 15 (1) , 1-12
Open AccessNumerical simulation of transcranial static magnetic fields for the treatment of global epilepsy in children
Transcranial static magnetic stimulation has shown the capacity to decrease systematically the cortical excitability in the treatment of epilepsy. Nevertheless, the application of these therapies to non-focal epilepsies is limited. This paper investigates on the numerical evaluation of promising strategies based on the application of static magnetic fields with multiple magnets on children. Results show that a ten-magnet configuration on the child’s head generates a magnetic flux density of 0.10 T in more than 70% of the brain cortex and more than 0.05 T in deep areas near the brain’s base. Conversely, the interaction between individual magnetic fields leads to regions of lower flux density, suggesting that not only the number of magnets, but also their relative position and orientation, are critical parameters. Thus, based on image diagnosis, it is possible to define a personalising procedure and develop an effective therapy of global epilepsy that penetrates sufficiently into the brain´s volume.
- 16 June 2025
- Published by IOP Publishing in Engineering Research Express
- Vol. 7 (2) , 025566
Design and setup of an experimental spirometric test bench for research
Spirometry is one of the most effective and widely used techniques for analysing human respiratory conditions and diseases. However, traditional spirometry equipment is limited in its ability to simulate pathological conditions beyond normal breathing, and standardization guidelines for testing procedures may unintentionally hinder progress in developing novel respiratory devices. This research presents the design of a flexible spirometry bench capable of simulating a broader range of pulmonary behaviours, from resting breathing to forced spirometry and even cough-induced airflow, enabling the development and testing of respiratory devices. The key components include pneumatic cylinders simulating lung volumes, a motor-driven actuation system controlling piston movements, and a spirometer recording air volume and flow. A Programmable Logic Controller (PLC) coordinates the actuators, sensors, and other control mechanisms, ensuring precision and reliability during experiments. Three types of tests were conducted: (1) reproducing periodic quiet breathing conditions using two predefined sinusoidal data sets, (2) acquiring a real spirometric curve from a patient, and (3) imposing a forced expiratory manoeuvre as input. The repeatability results, with the standard deviation not exceeding 0.1 and the coefficient of variation below 0.7%, highlight the high accuracy in reproducing curves. Maximum relative errors close to 1% were obtained for all analysed parameters during all tests performed. The test bench provides a flexible, high-precision platform for pulmonary research. Its wide operational range, precise control, and ability to replicate various respiratory scenarios make it a valuable tool for advancing respiratory health studies and supporting new therapeutic technologies by simulating real-life conditions.
- 16 June 2025
- Published by IOP Publishing in Engineering Research Express
- Vol. 7 (2) , 025566
Design and setup of an experimental spirometric test bench for research
Spirometry is one of the most effective and widely used techniques for analysing human respiratory conditions and diseases. However, traditional spirometry equipment is limited in its ability to simulate pathological conditions beyond normal breathing, and standardization guidelines for testing procedures may unintentionally hinder progress in developing novel respiratory devices. This research presents the design of a flexible spirometry bench capable of simulating a broader range of pulmonary behaviours, from resting breathing to forced spirometry and even cough-induced airflow, enabling the development and testing of respiratory devices. The key components include pneumatic cylinders simulating lung volumes, a motor-driven actuation system controlling piston movements, and a spirometer recording air volume and flow. A Programmable Logic Controller (PLC) coordinates the actuators, sensors, and other control mechanisms, ensuring precision and reliability during experiments. Three types of tests were conducted: (1) reproducing periodic quiet breathing conditions using two predefined sinusoidal data sets, (2) acquiring a real spirometric curve from a patient, and (3) imposing a forced expiratory manoeuvre as input. The repeatability results, with the standard deviation not exceeding 0.1 and the coefficient of variation below 0.7%, highlight the high accuracy in reproducing curves. Maximum relative errors close to 1% were obtained for all analysed parameters during all tests performed. The test bench provides a flexible, high-precision platform for pulmonary research. Its wide operational range, precise control, and ability to replicate various respiratory scenarios make it a valuable tool for advancing respiratory health studies and supporting new therapeutic technologies by simulating real-life conditions.
- Open Access
- 5 December 2023
- Published by Elsevier in Applied Thermal Engineering
- Vol. 240
Application of supervised learning algorithms for temperature prediction in nucleate flow boiling
- 5 December 2023
- Published by Elsevier in Applied Thermal Engineering
- Vol. 240
Open AccessApplication of supervised learning algorithms for temperature prediction in nucleate flow boiling
- Open Access
- 5 November 2023
- Published by Elsevier in IBRO Neuroscience Reports
- Vol. 15, S635-S636
TRANSCRANIAL STATIC MAGNETIC STIMULATION REDUCES SEIZURES IN A MOUSE MODEL OF DRAVET SYNDROME
- 5 November 2023
- Published by Elsevier in IBRO Neuroscience Reports
- Vol. 15, S635-S636
Open AccessTRANSCRANIAL STATIC MAGNETIC STIMULATION REDUCES SEIZURES IN A MOUSE MODEL OF DRAVET SYNDROME
- Open Access
- 19 July 2023
- Published by Springer Nature in Cardiovascular Engineering and Technology
- Vol. 14 (4) , 544-559
Numerical Study of a Thrombus Migration Risk in Aneurysm After Coil Embolization in Patient Cases: FSI Modelling
Purpose: There are still many challenges for modelling a thrombus migration process in aneurysms. The main novelty of the present research lies in the modelling of aneurysm clot migration process in a realistic cerebral aneurysm, and the analysis of forces suffered by clots inside an aneurysm, through transient FSI simulations. Methods: The blood flow has been modelled using a Womersley velocity profile, and following the Carreau viscosity model. Hyperelastic Ogden model has been used for clot and isotropic linear elastic model for the artery walls. The FSI coupled model was implemented in ANSYS® software. The hemodynamic forces suffered by the clot have been quantified using eight different clot sizes and positions inside a real aneurysm. Results: The obtained results have shown that it is almost impossible for clots adjacent to aneurysm walls, to leave the aneurysm. Nevertheless, in clots positioned in the centre of the aneurysm, there is a real risk of clot migration. The risk of migration of a typical post-coiling intervention clot in an aneurysm, in contact with the wall and occupying a significant percentage of its volume is very low in the case studied, even in the presence of abnormally intense events, associated with sneezes or impacts. Conclusions: The proposed methodology allows evaluating the clot migration risk, vital for evaluating the progress after endovascular interventions, it is a step forward in the personalized medicine, patient follow-up, and helping the medical team deciding the optimal treatment. Graphical
- 19 July 2023
- Published by Springer Nature in Cardiovascular Engineering and Technology
- Vol. 14 (4) , 544-559
Open AccessNumerical Study of a Thrombus Migration Risk in Aneurysm After Coil Embolization in Patient Cases: FSI Modelling
Purpose: There are still many challenges for modelling a thrombus migration process in aneurysms. The main novelty of the present research lies in the modelling of aneurysm clot migration process in a realistic cerebral aneurysm, and the analysis of forces suffered by clots inside an aneurysm, through transient FSI simulations. Methods: The blood flow has been modelled using a Womersley velocity profile, and following the Carreau viscosity model. Hyperelastic Ogden model has been used for clot and isotropic linear elastic model for the artery walls. The FSI coupled model was implemented in ANSYS® software. The hemodynamic forces suffered by the clot have been quantified using eight different clot sizes and positions inside a real aneurysm. Results: The obtained results have shown that it is almost impossible for clots adjacent to aneurysm walls, to leave the aneurysm. Nevertheless, in clots positioned in the centre of the aneurysm, there is a real risk of clot migration. The risk of migration of a typical post-coiling intervention clot in an aneurysm, in contact with the wall and occupying a significant percentage of its volume is very low in the case studied, even in the presence of abnormally intense events, associated with sneezes or impacts. Conclusions: The proposed methodology allows evaluating the clot migration risk, vital for evaluating the progress after endovascular interventions, it is a step forward in the personalized medicine, patient follow-up, and helping the medical team deciding the optimal treatment. Graphical