Gaurav Lalwani
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Gaurav Lalwani has a total of 40 co-authors. Here are the top co-authors by number of shared publications:
- Balaji Sitharaman
Department of Biomedical Engineering, Stony Brook University, Stony Brook, New York
20 shared publications Behzad Farshid
Department of Biomedical Engineering, Stony Brook University, Stony Brook, New York, 11794
6 shared publicationsAnu Gopalan
Department of Biomedical Engineering, Stony Brook University, Stony Brook, New York, 11794-5281
3 shared publications- Michael D'AGati
Electrical Engineering Department, University of Pennsylvania, Philadelphia, PA, USA
3 shared publications Shruti Kanakia
Department of Biomedical Engineering, Stony Brook University, Stony Brook, NY 11794-5281
3 shared publicationsStefan Judex
Department of Biomedical Engineering, Stony Brook University, Stony Brook, New York, 11794
3 shared publications
Latest Publications
- 11 January 2019
- Published by Wiley in Journal of Biomedical Materials Research Part A
- Vol. 107 (6) , 1143-1153
Two‐dimensional graphene oxide‐reinforced porous biodegradable polymeric nanocomposites for bone tissue engineering
This study investigates the mechanical properties and in vitro cytotoxicity of two‐dimensional (2D) graphene oxide nanoribbons and nanoplatelets (GONRs and GONPs) reinforced porous polymeric nanocomposites. Highly porous poly(propylene fumarate) (PPF) nanocomposites were prepared by dispersing 0.2 wt % single‐ and multiwalled SONRs (SWGONRs and MWGONRs) and GONPs. The mechanical properties of scaffolds were characterized using compression testing and in vitro cytocompatibility was assessed using QuantiFlour assay for cellularity and PrestoBlue assay for cell viability. Immunofluorescence was used to assess collagen‐I expression and deposition in the extracellular matrix. Porous PPF scaffolds were used as a baseline control and porous single and multiwalled carbon nanotubes (SWCNTs and MWCNTs) reinforced nanocomposites were used as positive controls. Results show that incorporation of 2D graphene nanomaterials leads to an increase in the mechanical properties of porous PPF nanocomposites with following the trend: MWGONRs > GONPs > SWGONRs > MWCNTs > SWCNTs > PPF control. MWGONRs showed the best enhancement of compressive mechanical properties with increases of up to 26% in compressive modulus (i.e., Young's modulus), ~60% in yield strength, and ~24% in the ultimate compressive strength. Addition of 2D nanomaterials did not alter the cytocompatibility of porous PPF nanocomposites. Furthermore, PPF nanocomposites reinforced with SWGONRs, MWGONRs, and GONPs show an improvement in the adsorption of collagen‐I compared to PPF baseline control. The results of this study show that 2D graphene nanomaterial reinforced porous PPF nanocomposites possess superior mechanical properties, cytocompatibility, and increased protein adsorption. The favorable cytocompatibility results opens avenues for in vivo safety and efficacy studies for bone tissue engineering applications. © 2019 Wiley Periodicals, Inc. J Biomed Mater Res Part A: 107A: 1143–1153, 2019.
- 11 January 2019
- Published by Wiley in Journal of Biomedical Materials Research Part A
- Vol. 107 (6) , 1143-1153
Two‐dimensional graphene oxide‐reinforced porous biodegradable polymeric nanocomposites for bone tissue engineering
This study investigates the mechanical properties and in vitro cytotoxicity of two‐dimensional (2D) graphene oxide nanoribbons and nanoplatelets (GONRs and GONPs) reinforced porous polymeric nanocomposites. Highly porous poly(propylene fumarate) (PPF) nanocomposites were prepared by dispersing 0.2 wt % single‐ and multiwalled SONRs (SWGONRs and MWGONRs) and GONPs. The mechanical properties of scaffolds were characterized using compression testing and in vitro cytocompatibility was assessed using QuantiFlour assay for cellularity and PrestoBlue assay for cell viability. Immunofluorescence was used to assess collagen‐I expression and deposition in the extracellular matrix. Porous PPF scaffolds were used as a baseline control and porous single and multiwalled carbon nanotubes (SWCNTs and MWCNTs) reinforced nanocomposites were used as positive controls. Results show that incorporation of 2D graphene nanomaterials leads to an increase in the mechanical properties of porous PPF nanocomposites with following the trend: MWGONRs > GONPs > SWGONRs > MWCNTs > SWCNTs > PPF control. MWGONRs showed the best enhancement of compressive mechanical properties with increases of up to 26% in compressive modulus (i.e., Young's modulus), ~60% in yield strength, and ~24% in the ultimate compressive strength. Addition of 2D nanomaterials did not alter the cytocompatibility of porous PPF nanocomposites. Furthermore, PPF nanocomposites reinforced with SWGONRs, MWGONRs, and GONPs show an improvement in the adsorption of collagen‐I compared to PPF baseline control. The results of this study show that 2D graphene nanomaterial reinforced porous PPF nanocomposites possess superior mechanical properties, cytocompatibility, and increased protein adsorption. The favorable cytocompatibility results opens avenues for in vivo safety and efficacy studies for bone tissue engineering applications. © 2019 Wiley Periodicals, Inc. J Biomed Mater Res Part A: 107A: 1143–1153, 2019.
- 3 April 2017
- Published by Wiley in Journal of Biomedical Materials Research Part A
- Vol. 105 (7) , 1927-1939
Three‐dimensional carbon nanotube scaffolds for long‐term maintenance and expansion of human mesenchymal stem cells
Expansion of mesenchymal stem cells (MSCs) and maintenance of their self‐renewal capacity in vitro requires specialized robust cell culture systems. Conventional approaches using animal‐derived or artificial matrices and a cocktail of growth factors have limitations such as consistency, scalability, pathogenicity, and loss of MSC phenotype. Herein, we report the use of all‐carbon 3‐D single‐ and multiwalled carbon nanotube scaffolds (SWCNTs and MWCNTs) as artificial matrices for long‐term maintenance and expansion of human MSCs. Three‐dimensional SWCNT and MWCNT scaffolds were fabricated using a novel radical initiated thermal cross‐linking method that covalently cross‐links CNTs to form 3‐D macroporous all‐carbon architectures. Adipose‐derived human MSCs showed good cell viability, attachment, proliferation, and infiltration in MWCNT and SWCNT scaffolds comparable to poly(lactic‐co‐glycolic) acid (PLGA) scaffolds (baseline control). ADSCs retained stem cell phenotype after 30 days and satisfied the International Society for Cellular Therapy's (ISCT) minimal criteria for MSCs. Post expansion, (1) ADSCs showed in vitro adherence to tissue culture polystyrene (TCPS); (2) MSC surface antigen expression [CD14(−), CD19(−), CD34(−), CD45(−), CD73(+), CD90(+), CD105(+)]; and (3) trilineage differentiation into osteoblasts, adipocytes, and chondrocytes. Results show that cross‐linked 3‐D MWCNTs and SWCNTs scaffolds are suitable for ex vivo expansion and maintenance of MSCs for therapeutic applications. © 2016 Wiley Periodicals, Inc. J Biomed Mater Res Part A: 105A: 1927–1939, 2017.
- 3 April 2017
- Published by Wiley in Journal of Biomedical Materials Research Part A
- Vol. 105 (7) , 1927-1939
Three‐dimensional carbon nanotube scaffolds for long‐term maintenance and expansion of human mesenchymal stem cells
Expansion of mesenchymal stem cells (MSCs) and maintenance of their self‐renewal capacity in vitro requires specialized robust cell culture systems. Conventional approaches using animal‐derived or artificial matrices and a cocktail of growth factors have limitations such as consistency, scalability, pathogenicity, and loss of MSC phenotype. Herein, we report the use of all‐carbon 3‐D single‐ and multiwalled carbon nanotube scaffolds (SWCNTs and MWCNTs) as artificial matrices for long‐term maintenance and expansion of human MSCs. Three‐dimensional SWCNT and MWCNT scaffolds were fabricated using a novel radical initiated thermal cross‐linking method that covalently cross‐links CNTs to form 3‐D macroporous all‐carbon architectures. Adipose‐derived human MSCs showed good cell viability, attachment, proliferation, and infiltration in MWCNT and SWCNT scaffolds comparable to poly(lactic‐co‐glycolic) acid (PLGA) scaffolds (baseline control). ADSCs retained stem cell phenotype after 30 days and satisfied the International Society for Cellular Therapy's (ISCT) minimal criteria for MSCs. Post expansion, (1) ADSCs showed in vitro adherence to tissue culture polystyrene (TCPS); (2) MSC surface antigen expression [CD14(−), CD19(−), CD34(−), CD45(−), CD73(+), CD90(+), CD105(+)]; and (3) trilineage differentiation into osteoblasts, adipocytes, and chondrocytes. Results show that cross‐linked 3‐D MWCNTs and SWCNTs scaffolds are suitable for ex vivo expansion and maintenance of MSCs for therapeutic applications. © 2016 Wiley Periodicals, Inc. J Biomed Mater Res Part A: 105A: 1927–1939, 2017.
- 27 August 2016
- Published by Wiley in Journal of Biomedical Materials Research Part A
- Vol. 105 (1) , 73-83
Three‐dimensional macroporous graphene scaffolds for tissue engineering
The assembly of carbon nanomaterials into three‐dimensional (3D) porous scaffolds is critical to harness their unique physiochemical properties for tissue engineering and regenerative medicine applications. In this study, we report the fabrication, characterization, and in vitro cytocompatibility of true 3D (>1 mm in all three dimensions), macroscopic (3–8 mm in height and 4–6 mm in diameter), chemically cross‐linked graphene scaffolds prepared via radical initiated thermal cross‐linking of single‐ and multiwalled graphene oxide nanoribbons (SWGONRs and MWGONRs). SWGONR and MWGONR scaffolds possess tunable porosity (∼65‐80%) and interconnected macro‐, micro‐, and nanoscale pores. Human adipose derived stem cells (ADSCs) and murine MC3T3 preosteoblast cells show good cell viability on SWGONR and MWGONR scaffolds after 1, 3, and 5 days comparable to 3D poly(lactic‐co‐glycolic) acid (PLGA) scaffolds. Confocal live‐cell imaging showed that cells were metabolically active and could spread on SWGONR and MWGONR scaffolds. Immunofluorescence imaging showed the presence of focal adhesion protein vinculin and expression of cell proliferation marker Ki‐67 suggesting that cells could attach and proliferate on SWGONR and MWGONR scaffolds. These results indicate that cross‐linked SWGONR and MWGONR scaffolds are cytocompatible and opens‐avenues toward the development of 3D multifunctional graphene scaffolds for tissue engineering applications. © 2016 Wiley Periodicals, Inc. J Biomed Mater Res Part A: 105A: 73–83, 2017.
- 27 August 2016
- Published by Wiley in Journal of Biomedical Materials Research Part A
- Vol. 105 (1) , 73-83
Three‐dimensional macroporous graphene scaffolds for tissue engineering
The assembly of carbon nanomaterials into three‐dimensional (3D) porous scaffolds is critical to harness their unique physiochemical properties for tissue engineering and regenerative medicine applications. In this study, we report the fabrication, characterization, and in vitro cytocompatibility of true 3D (>1 mm in all three dimensions), macroscopic (3–8 mm in height and 4–6 mm in diameter), chemically cross‐linked graphene scaffolds prepared via radical initiated thermal cross‐linking of single‐ and multiwalled graphene oxide nanoribbons (SWGONRs and MWGONRs). SWGONR and MWGONR scaffolds possess tunable porosity (∼65‐80%) and interconnected macro‐, micro‐, and nanoscale pores. Human adipose derived stem cells (ADSCs) and murine MC3T3 preosteoblast cells show good cell viability on SWGONR and MWGONR scaffolds after 1, 3, and 5 days comparable to 3D poly(lactic‐co‐glycolic) acid (PLGA) scaffolds. Confocal live‐cell imaging showed that cells were metabolically active and could spread on SWGONR and MWGONR scaffolds. Immunofluorescence imaging showed the presence of focal adhesion protein vinculin and expression of cell proliferation marker Ki‐67 suggesting that cells could attach and proliferate on SWGONR and MWGONR scaffolds. These results indicate that cross‐linked SWGONR and MWGONR scaffolds are cytocompatible and opens‐avenues toward the development of 3D multifunctional graphene scaffolds for tissue engineering applications. © 2016 Wiley Periodicals, Inc. J Biomed Mater Res Part A: 105A: 73–83, 2017.
- 3 November 2015
- Published by Wiley in Journal of Biomedical Materials Research Part B: Applied Biomaterials
- Vol. 105 (2) , 406-419
Boron nitride nanotubes and nanoplatelets as reinforcing agents of polymeric matrices for bone tissue engineering
This study investigates the mechanical properties andin vitrocytotoxicity of one‐ and two‐dimensional boron nitride nanomaterials‐reinforced biodegradable polymeric nanocomposites. Poly(propylene fumarate) (PPF) nanocomposites were fabricated using crosslinking agentN‐vinyl pyrrolidone and inorganic nanomaterials: boron nitride nanotubes (BNNTs) and boron nitride nanoplatelets (BNNPs) dispersed at 0.2 wt % in the polymeric matrix. The incorporation of BNNPs and BNNTs resulted in a ∼38 and ∼15% increase in compressive (Young's) modulus, and ∼31 and ∼6% increase in compressive yield strength compared to PPF control, respectively. The nanocomposites showed a time‐dependent increased protein adsorption for collagen I protein. The cytotoxicity evaluation of aqueous BNNT and BNNP dispersions (at 1–100 μg/mL concentrations) using murine MC3T3 preosteoblast cells showed ∼73–99% viability. The cytotoxicity evaluation of media extracts of nanocomposites before crosslinking, after crosslinking, and upon degradation (using 1×–100× dilutions) showed dose‐dependent cytotoxicity responses. Crosslinked nanocomposites showed excellent (∼79–100%) cell viability, cellular attachment (∼57–67%), and spreading similar to cells grown on the surface of tissue culture polystyrene control. The media extracts of degradation products showed a dose‐dependent cytotoxicity. The favorable cytocompatibility results in combination with improved mechanical properties of BNNT and BNNP nanocomposites opens new avenues for furtherin vitroandin vivosafety and efficacy studies towards bone tissue engineering applications. © 2015 Wiley Periodicals, Inc. J Biomed Mater Res Part B: Appl Biomater, 105B: 406–419, 2017.
- 3 November 2015
- Published by Wiley in Journal of Biomedical Materials Research Part B: Applied Biomaterials
- Vol. 105 (2) , 406-419
Boron nitride nanotubes and nanoplatelets as reinforcing agents of polymeric matrices for bone tissue engineering
This study investigates the mechanical properties andin vitrocytotoxicity of one‐ and two‐dimensional boron nitride nanomaterials‐reinforced biodegradable polymeric nanocomposites. Poly(propylene fumarate) (PPF) nanocomposites were fabricated using crosslinking agentN‐vinyl pyrrolidone and inorganic nanomaterials: boron nitride nanotubes (BNNTs) and boron nitride nanoplatelets (BNNPs) dispersed at 0.2 wt % in the polymeric matrix. The incorporation of BNNPs and BNNTs resulted in a ∼38 and ∼15% increase in compressive (Young's) modulus, and ∼31 and ∼6% increase in compressive yield strength compared to PPF control, respectively. The nanocomposites showed a time‐dependent increased protein adsorption for collagen I protein. The cytotoxicity evaluation of aqueous BNNT and BNNP dispersions (at 1–100 μg/mL concentrations) using murine MC3T3 preosteoblast cells showed ∼73–99% viability. The cytotoxicity evaluation of media extracts of nanocomposites before crosslinking, after crosslinking, and upon degradation (using 1×–100× dilutions) showed dose‐dependent cytotoxicity responses. Crosslinked nanocomposites showed excellent (∼79–100%) cell viability, cellular attachment (∼57–67%), and spreading similar to cells grown on the surface of tissue culture polystyrene control. The media extracts of degradation products showed a dose‐dependent cytotoxicity. The favorable cytocompatibility results in combination with improved mechanical properties of BNNT and BNNP nanocomposites opens new avenues for furtherin vitroandin vivosafety and efficacy studies towards bone tissue engineering applications. © 2015 Wiley Periodicals, Inc. J Biomed Mater Res Part B: Appl Biomater, 105B: 406–419, 2017.
- 18 March 2015
- Published by Wiley in Journal of Biomedical Materials Research Part A
- Vol. 103 (10) , 3212-3225
Porous three-dimensional carbon nanotube scaffolds for tissue engineering
Assembly of carbon nanomaterials into three‐dimensional (3D) architectures is necessary to harness their unique physiochemical properties for tissue engineering and regenerative medicine applications. Herein, we report the fabrication and comprehensive cytocompatibility assessment of 3D chemically crosslinked macrosized (5–8 mm height and 4–6 mm diameter) porous carbon nanotube (CNT) scaffolds. Scaffolds prepared via radical initiated thermal crosslinking of single‐ or multiwalled CNTs (SWCNTs and MWCNTs) possess high porosity (>80%), and nano‐, micro‐, and macroscale interconnected pores. MC3T3 preosteoblast cells on MWCNT and SWCNT scaffolds showed good cell viability comparable to poly(lactic‐co‐glycolic) acid (PLGA) scaffolds after 5 days. Confocal live cell and immunofluorescence imaging showed that MC3T3 cells were metabolically active and could attach, proliferate, and infiltrate MWCNT and SWCNT scaffolds. SEM imaging corroborated cell attachment and spreading and suggested that cell morphology is governed by scaffold surface roughness. MC3T3 cells were elongated on scaffolds with high surface roughness (MWCNTs) and rounded on scaffolds with low surface roughness (SWCNTs). The surface roughness of scaffolds may be exploited to control cellular morphology and, in turn, govern cell fate. These results indicate that crosslinked MWCNTs and SWCNTs scaffolds are cytocompatible, and open avenues toward development of multifunctional all‐carbon scaffolds for tissue engineering applications. © 2015 Wiley Periodicals, Inc. J Biomed Mater Res Part A: 103A: 3212–3225, 2015.
- 18 March 2015
- Published by Wiley in Journal of Biomedical Materials Research Part A
- Vol. 103 (10) , 3212-3225
Porous three-dimensional carbon nanotube scaffolds for tissue engineering
Assembly of carbon nanomaterials into three‐dimensional (3D) architectures is necessary to harness their unique physiochemical properties for tissue engineering and regenerative medicine applications. Herein, we report the fabrication and comprehensive cytocompatibility assessment of 3D chemically crosslinked macrosized (5–8 mm height and 4–6 mm diameter) porous carbon nanotube (CNT) scaffolds. Scaffolds prepared via radical initiated thermal crosslinking of single‐ or multiwalled CNTs (SWCNTs and MWCNTs) possess high porosity (>80%), and nano‐, micro‐, and macroscale interconnected pores. MC3T3 preosteoblast cells on MWCNT and SWCNT scaffolds showed good cell viability comparable to poly(lactic‐co‐glycolic) acid (PLGA) scaffolds after 5 days. Confocal live cell and immunofluorescence imaging showed that MC3T3 cells were metabolically active and could attach, proliferate, and infiltrate MWCNT and SWCNT scaffolds. SEM imaging corroborated cell attachment and spreading and suggested that cell morphology is governed by scaffold surface roughness. MC3T3 cells were elongated on scaffolds with high surface roughness (MWCNTs) and rounded on scaffolds with low surface roughness (SWCNTs). The surface roughness of scaffolds may be exploited to control cellular morphology and, in turn, govern cell fate. These results indicate that crosslinked MWCNTs and SWCNTs scaffolds are cytocompatible, and open avenues toward development of multifunctional all‐carbon scaffolds for tissue engineering applications. © 2015 Wiley Periodicals, Inc. J Biomed Mater Res Part A: 103A: 3212–3225, 2015.
- 4 November 2014
- Published by Wiley in Journal of Biomedical Materials Research Part A
- Vol. 103 (7) , 2309-2321
In vitrocytocompatibility of one-dimensional and two-dimensional nanostructure-reinforced biodegradable polymeric nanocomposites
This study investigates the in vitro cytocompatibility of one‐dimensional and two‐dimensional (1D and 2D) carbon and inorganic nanomaterial reinforced polymeric nanocomposites fabricated using biodegradable polymer poly (propylene fumarate), crosslinking agent N‐vinyl pyrrolidone (NVP) and following nanomaterials: single and multiwalled carbon nanotubes, single and multiwalled graphene oxide nanoribbons, graphene oxide nanoplatelets, molybdenum disulfide nanoplatelets, or tungsten disulfide nanotubes dispersed between 0.02 and 0.2 wt% concentrations in the polymer. The extraction media of unreacted components, crosslinked nanocomposites and their degradation products were examined for effects on viability and attachment using two cell lines: NIH3T3 fibroblasts and MC3T3 preosteoblasts. The extraction media of unreacted PPF/NVP elicited acute dose‐dependent cytotoxicity attributed to leaching of unreacted components into cell culture media. However, extraction media of crosslinked nanocomposites showed no dose dependent adverse effects. Further, all crosslinked nanocomposites showed high viability (78–100%), high cellular attachment (40–55%), and spreading that was confirmed by confocal and scanning electron microscopy. Degradation products of nanocomposites showed a mild dose‐dependent cytotoxicity possibly due to acidic degradation components of PPF. In general, compared to PPF control, none of the nanocomposites showed significant differences in cellular response to unreacted components, crosslinked nanocomposites and their degradation products. Initial minor cytotoxic response and lower cell attachment numbers were observed only for a few nanocomposite groups; these effects were absent at later time points for all PPF nanocomposites. The favorable cytocompatibility results for all the nanocomposites opens avenues for in vivo safety and efficacy studies for bone tissue engineering applications. © 2014 Wiley Periodicals, Inc. J Biomed Mater Res Part A: 103: 2309–2321, 2015.
- 4 November 2014
- Published by Wiley in Journal of Biomedical Materials Research Part A
- Vol. 103 (7) , 2309-2321
In vitrocytocompatibility of one-dimensional and two-dimensional nanostructure-reinforced biodegradable polymeric nanocomposites
This study investigates the in vitro cytocompatibility of one‐dimensional and two‐dimensional (1D and 2D) carbon and inorganic nanomaterial reinforced polymeric nanocomposites fabricated using biodegradable polymer poly (propylene fumarate), crosslinking agent N‐vinyl pyrrolidone (NVP) and following nanomaterials: single and multiwalled carbon nanotubes, single and multiwalled graphene oxide nanoribbons, graphene oxide nanoplatelets, molybdenum disulfide nanoplatelets, or tungsten disulfide nanotubes dispersed between 0.02 and 0.2 wt% concentrations in the polymer. The extraction media of unreacted components, crosslinked nanocomposites and their degradation products were examined for effects on viability and attachment using two cell lines: NIH3T3 fibroblasts and MC3T3 preosteoblasts. The extraction media of unreacted PPF/NVP elicited acute dose‐dependent cytotoxicity attributed to leaching of unreacted components into cell culture media. However, extraction media of crosslinked nanocomposites showed no dose dependent adverse effects. Further, all crosslinked nanocomposites showed high viability (78–100%), high cellular attachment (40–55%), and spreading that was confirmed by confocal and scanning electron microscopy. Degradation products of nanocomposites showed a mild dose‐dependent cytotoxicity possibly due to acidic degradation components of PPF. In general, compared to PPF control, none of the nanocomposites showed significant differences in cellular response to unreacted components, crosslinked nanocomposites and their degradation products. Initial minor cytotoxic response and lower cell attachment numbers were observed only for a few nanocomposite groups; these effects were absent at later time points for all PPF nanocomposites. The favorable cytocompatibility results for all the nanocomposites opens avenues for in vivo safety and efficacy studies for bone tissue engineering applications. © 2014 Wiley Periodicals, Inc. J Biomed Mater Res Part A: 103: 2309–2321, 2015.
- 22 July 2014
- Published by Royal Society of Chemistry (RSC) in Journal of Materials Chemistry B
- Vol. 2 (37) , 6354-6362
Enzymatic degradation of oxidized and reduced graphene nanoribbons by lignin peroxidase
The widespread use of graphene for various industrial and biomedical applications requires efficient remediation strategies during its disposal into waste streams. In addition, the interactions of graphene with the biota need thorough evaluation. In this study, we investigated the interactions of oxidized and reduced graphene oxide nanoribbons (GONRs and rGONRs) with lignin peroxidase (LiP), a ligninolytic enzyme released from white rot fungus. GONRs and rGONRs were treated with LiP in the presence and absence of veratryl alcohol (VA; an electron transfer mediator and secondary metabolite of white rot fungi). Transmission electron microscopy showed the formation of large defects (holes) in the graphene sheet, which increased in diameter with increased degradation time. Raman spectroscopic analysis indicated that, within 96 hours, in the presence of hydrogen peroxide and VA, the GONRs and rGONRs were completely and partially degraded by LiP, respectively. Comparisons between groups with or without VA showed that degradation of GONRs was accelerated in the presence of VA. These results indicated that LiP could efficiently degrade GONRs and rGONRs in the presence of VA, suggesting that VA may be an essential factor needed to degrade rGONRs via LiP treatment. Thus, the wide presence of white rot fungi, and thereby LiP, in nature, could lead to efficient degradation of graphene present in the environment. Additionally, LiP, which has a higher theoretical redox potential compared to horseradish peroxidases and myeloperoxidases, could be a better candidate for the environmental remediation of graphene.
- 22 July 2014
- Published by Royal Society of Chemistry (RSC) in Journal of Materials Chemistry B
- Vol. 2 (37) , 6354-6362
Enzymatic degradation of oxidized and reduced graphene nanoribbons by lignin peroxidase
The widespread use of graphene for various industrial and biomedical applications requires efficient remediation strategies during its disposal into waste streams. In addition, the interactions of graphene with the biota need thorough evaluation. In this study, we investigated the interactions of oxidized and reduced graphene oxide nanoribbons (GONRs and rGONRs) with lignin peroxidase (LiP), a ligninolytic enzyme released from white rot fungus. GONRs and rGONRs were treated with LiP in the presence and absence of veratryl alcohol (VA; an electron transfer mediator and secondary metabolite of white rot fungi). Transmission electron microscopy showed the formation of large defects (holes) in the graphene sheet, which increased in diameter with increased degradation time. Raman spectroscopic analysis indicated that, within 96 hours, in the presence of hydrogen peroxide and VA, the GONRs and rGONRs were completely and partially degraded by LiP, respectively. Comparisons between groups with or without VA showed that degradation of GONRs was accelerated in the presence of VA. These results indicated that LiP could efficiently degrade GONRs and rGONRs in the presence of VA, suggesting that VA may be an essential factor needed to degrade rGONRs via LiP treatment. Thus, the wide presence of white rot fungi, and thereby LiP, in nature, could lead to efficient degradation of graphene present in the environment. Additionally, LiP, which has a higher theoretical redox potential compared to horseradish peroxidases and myeloperoxidases, could be a better candidate for the environmental remediation of graphene.
- 1 June 2014
- Published by Elsevier in Biomaterials
- Vol. 35 (18) , 4863-4877
The effects of graphene nanostructures on mesenchymal stem cells
- 1 June 2014
- Published by Elsevier in Biomaterials
- Vol. 35 (18) , 4863-4877
The effects of graphene nanostructures on mesenchymal stem cells
- 21 March 2014
- Published by Royal Society of Chemistry (RSC) in Journal of Materials Chemistry B
- Vol. 2 (22) , 3519-3530
Synthesis, characterization, in vitro phantom imaging, and cytotoxicity of a novel graphene-based multimodal magnetic resonance imaging-X-ray computed tomography contrast agent
Graphene nanoplatelets (GNPs), synthesized by potassium permanganate-based oxidation and exfoliation followed by reduction with hydroiodic acid (rGNP–HI), intercalated with manganese ions within the graphene sheets, and covalently functionalized with iodine, exhibit excellent potential as biomodal contrast agents for magnetic resonance imaging (MRI) and computed tomography (CT). Structural characterization of rGNP–HI nanoparticles with low- and high-resolution transmission electron microscopy (TEM) showed disc-shaped nanoparticles (average diameter, 200 nm and average thickness, 3 nm). Energy dispersive X-ray spectroscopy (EDX) analysis confirmed the presence of intercalated manganese. Raman spectroscopy and X-ray diffraction (XRD) analysis of rGNP–HI confirmed the reduction of oxidized GNPs (O-GNPs), the absence of molecular and physically-adsorbed iodine, and the functionalization of graphene with iodine as polyiodide complexes (I3 − and I5 −). Manganese and iodine contents were quantified to be 5.1 ± 0.5 and 10.54 ± 0.87 wt% by inductively coupled plasma optical emission spectroscopy and ion-selective electrode measurements, respectively. In vitro cytotoxicity analysis, using absorbance (LDH assay) and fluorescence (calcein AM) assays, performed on NIH3T3 mouse fibroblasts and A498 human kidney epithelial cells, indicated CD50 values of rGNP–HI between 179 and 301 μg ml−1, depending on the cell line and the cytotoxicity assay. CT and MRI phantom imaging of rGNP–HI displayed high CT (approximately 3200% greater than that of HI at equimolar iodine concentration) and MRI (approximately 59% greater than that of an equimolar Mn2+ solution) contrast. These results open avenues for further in vivo safety and efficacy studies towards the development of carbon nanostructure-based multimodal MRI-CT contrast agents.
- 21 March 2014
- Published by Royal Society of Chemistry (RSC) in Journal of Materials Chemistry B
- Vol. 2 (22) , 3519-3530
Synthesis, characterization, in vitro phantom imaging, and cytotoxicity of a novel graphene-based multimodal magnetic resonance imaging-X-ray computed tomography contrast agent
Graphene nanoplatelets (GNPs), synthesized by potassium permanganate-based oxidation and exfoliation followed by reduction with hydroiodic acid (rGNP–HI), intercalated with manganese ions within the graphene sheets, and covalently functionalized with iodine, exhibit excellent potential as biomodal contrast agents for magnetic resonance imaging (MRI) and computed tomography (CT). Structural characterization of rGNP–HI nanoparticles with low- and high-resolution transmission electron microscopy (TEM) showed disc-shaped nanoparticles (average diameter, 200 nm and average thickness, 3 nm). Energy dispersive X-ray spectroscopy (EDX) analysis confirmed the presence of intercalated manganese. Raman spectroscopy and X-ray diffraction (XRD) analysis of rGNP–HI confirmed the reduction of oxidized GNPs (O-GNPs), the absence of molecular and physically-adsorbed iodine, and the functionalization of graphene with iodine as polyiodide complexes (I3 − and I5 −). Manganese and iodine contents were quantified to be 5.1 ± 0.5 and 10.54 ± 0.87 wt% by inductively coupled plasma optical emission spectroscopy and ion-selective electrode measurements, respectively. In vitro cytotoxicity analysis, using absorbance (LDH assay) and fluorescence (calcein AM) assays, performed on NIH3T3 mouse fibroblasts and A498 human kidney epithelial cells, indicated CD50 values of rGNP–HI between 179 and 301 μg ml−1, depending on the cell line and the cytotoxicity assay. CT and MRI phantom imaging of rGNP–HI displayed high CT (approximately 3200% greater than that of HI at equimolar iodine concentration) and MRI (approximately 59% greater than that of an equimolar Mn2+ solution) contrast. These results open avenues for further in vivo safety and efficacy studies towards the development of carbon nanostructure-based multimodal MRI-CT contrast agents.
- 24 February 2014
- Published by Wiley in Particle & Particle Systems Characterization
- Vol. 31 (7) , 745-750
Degradation of Graphene by Hydrogen Peroxide
- 24 February 2014
- Published by Wiley in Particle & Particle Systems Characterization
- Vol. 31 (7) , 745-750
Degradation of Graphene by Hydrogen Peroxide