AGAlejandro Gonzalo

Alejandro Gonzalo

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Alejandro Gonzalo has a total of 51 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Effect of Wall Motion Sampling on CFD ‐Derived Left Atrial Flow Metrics

    by Yvonne Stöcker, Manuel Guerrero‐Hurtado, Eduardo Durán, Alejandro Gonzalo, Zorica Ristić, Åshild Telle, Ahmad Kassar, Romanos Haykal, Nazem Akoum, Patrick M. Boyle, et al.

    The temporal resolution of medical imaging sequences used to drive patient‐specific computational fluid dynamics (CFD) simulations remains limited, typically providing 10–20 frames per cardiac cycle. Therefore, temporal interpolation to reconstruct left atrial (LA) wall motion and boundary conditions is required, but its impact on hemodynamic predictions has not been systematically characterized. To investigate this, we constructed high‐temporal‐resolution reference wall‐motion data using electromechanical (EM) simulations on five patient‐specific atrial geometries with a history of atrial fibrillation. We then generated temporally downsampled datasets to emulate clinical frame rates (5, 10, 20, and 40 frames per cycle) and performed CFD simulations to isolate the effects of temporal undersampling on hemodynamic metrics. The focus was placed on kinetic energy, KE, and residence time, , particularly in the left atrial appendage (LAA), where thrombosis is most likely to occur. We employed an immersed boundary method to prescribe the wall motion and computed blood through a passive scalar transport equation. Results indicate that while global LA hemodynamic indices were marginally affected by the frame rate (errors ), LAA metrics were more sensitive with errors up to 31% compared to reference values. The results based on 20 and 40 frames per cycle yielded favorable agreement with reference results, while 5‐ and 10‐frame reconstructions showed larger, though not systematically biased, deviations from the reference. Importantly, patient ranking by blood‐stasis indices was largely preserved. The analysis suggests that patient‐specific LA reconstructions derived from dynamic CT imaging provide a reliable basis for estimating LAA blood‐stasis indices. Higher frame rates ( per cycle) offer improved quantitative accuracy, while lower temporal resolutions may remain informative for patient stratification purposes, where relative ranking is more relevant than absolute accuracy.

  • Open Access

    Fibrosis burden and spatial pattern affect left atrial appendage stasis in multi-beat multi-physics simulations

    by Yvonne Stöcker, Christoph M. Augustin, Manuel Guerrero-Hurtado, Oscar Flores, Alejandro Gonzalo, Åshild Telle, Patrick M. Boyle, Nazem Akoum, Juan C. del Alamo, Manuel García-Villalba

    Purpose: Atrial fibrosis is associated with thromboembolic risk in atrial fibrillation, but it remains unclear how fibrosis-related contractile impairment alters blood transport in the left atrium (LA) and left atrial appendage (LAA). Prior multi-physics simulations coupling electromechanical (EM) and computational fluid dynamics (CFD) models showed that fibrosis impairs LA function and flow, but were limited to booster-only contraction and could not separate the effects of fibrosis burden from its spatial distribution. Here, we examined how fibrosis burden and spatial pattern independently relate to long-term LA and LAA hemodynamics in full-cycle, multi-beat simulations on a common LA anatomy. Methods: Three fibrosis patterns derived from late gadolinium enhancement MRI were applied globally to a common LA anatomy at matched burdens of 15.6% and 31.2%, yielding six global-fibrosis cases and a non-fibrotic reference. Two patterns were also confined to the LAA at local burdens of 10%, 25%, and 50%, yielding six LAA-fibrosis cases. A 3D EM model of the LA anatomy coupled to a 0D circulatory model resolved the reservoir, conduit, and booster phases, and the EM-derived wall motion drove subsequent multi-beat CFD simulations. Region-specific emptying fraction (EF), non-dimensional kinetic energy (KE), and the 90th percentile of blood residence time (T R ) were evaluated in the LA and LAA. Results: Left ventricular stroke volume remained nearly constant across cases, whereas increasing global fibrosis burden progressively reduced LA and LAA EF (LA: 36% to 30–31%; LAA: 44% to 28–38%), lowered both active and passive LA EF, and monotonically increased LA T R across all patterns. Non-dimensional LA KE showed an approximately quadratic association with LA EF across patterns, whereas LAA KE was more scattered but still increased with LAA EF. In contrast, the 90th percentile of LAA T R did not increase monotonically with decreasing LAA EF for one pattern. When fibrosis was confined to the LAA, non-dimensional LAA KE collapsed onto a single relationship with LAA EF for both patterns, whereas LAA T R followed distinct, non-monotonic trends. Conclusions: Fibrosis burden, through its association with functional impairment, predominantly governed whole-LA hemodynamics, whereas LAA stasis additionally depended on the spatial distribution of fibrosis. In the LAA-fibrosis cases, LAA EF was a robust descriptor of chamber-averaged KE regardless of fibrosis pattern, but did not fully explain LAA residence time. These findings support evaluating imaging-derived fibrosis pattern, in addition to fibrosis burden and functional metrics, as a potential determinant of LAA transport and stasis. Its incremental value for thrombogenic-risk assessment requires prospective clinical validation.

  • Open Access

    Hemodynamics affects factor XI/XII anticoagulation efficacy in patient-derived left atrial models

    by M. Guerrero-Hurtado, M. García-Villalba, A. Gonzalo, E. Durán, P. Martinez-Legazpi, P. Ávila, A.M. Kahn, M.Y. Chen, E. McVeigh, J. Bermejo, et al.


  • Super-resolution left ventricular flow and pressure mapping by Navier–Stokes-informed neural networks

    by Bahetihazi Maidu, Pablo Martinez-Legazpi, Manuel Guerrero-Hurtado, Cathleen M. Nguyen, Alejandro Gonzalo, Andrew M. Kahn, Javier Bermejo, Oscar Flores, Juan C. del Alamo


  • Open Access

    A Python-based flow solver for numerical simulations using an immersed boundary method on single GPUs

    by M. Guerrero-Hurtado, J.M. Catalán, M. Moriche, A. Gonzalo, O. Flores


  • Multiphysics simulations reveal haemodynamic impacts of patient‐derived fibrosis‐related changes in left atrial tissue mechanics

    by Alejandro Gonzalo, Christoph M. Augustin, Savannah F. Bifulco, Åshild Telle, Yaacoub Chahine, Ahmad Kassar, Manuel Guerrero‐Hurtado, Eduardo Durán, Pablo Martínez‐Legazpi, Oscar Flores, et al.

    Stroke is a leading cause of death and disability worldwide. Atrial myopathy, including fibrosis, is associated with an increased risk of ischaemic stroke, but the mechanisms underlying this association are poorly understood. Fibrosis modifies myocardial structure, impairing electrical propagation and tissue biomechanics, and creating stagnant flow regions where clots could form. Fibrosis can be mapped non‐invasively using late gadolinium enhancement magnetic resonance imaging (LGE‐MRI). However, fibrosis maps are not currently incorporated into stroke risk calculations or computational electro‐mechano‐fluidic models. We present multiphysics simulations of left atrial (LA) myocardial motion and haemodynamics using patient‐specific anatomies and fibrotic maps from LGE‐MRI. We modify tissue stiffness and active tension generation in fibrotic regions and investigate how these changes affect LA flow for different fibrotic burdens. We find that fibrotic regions and, to a lesser extent, non‐fibrotic regions experience reduced myocardial strain, resulting in decreased LA emptying fraction consistent with clinical observations. Both fibrotic tissue stiffening and hypocontractility independently reduce LA function, but, together, these two alterations cause more pronounced effects than either one alone. Fibrosis significantly alters flow patterns throughout the atrial chamber, and particularly, the filling and emptying jets of the left atrial appendage (LAA). The effects of fibrosis in LA flow are largely captured by the concomitant changes in LA emptying fraction except inside the LAA, where a multifactorial behaviour is observed. This work illustrates how high‐fidelity, multiphysics models can be used to study thrombogenesis mechanisms in patient‐specific anatomies, shedding light onto the links between atrial fibrosis and ischaemic stroke. image Key points: Left atrial (LA) fibrosis is associated with arrhythmogenesis and increased risk of ischaemic stroke; its extent and pattern can be quantified on a patient‐specific basis using late gadolinium enhancement magnetic resonance imaging. Current stroke risk prediction tools have limited personalization, and their accuracy could be improved by incorporating patient‐specific information such as fibrotic maps and haemodynamic patterns. We present the first electro‐mechano‐fluidic multiphysics computational simulations of LA flow, including fibrosis and anatomies from medical imaging. Mechanical changes in fibrotic tissue impair global LA motion, decreasing LA and left atrial appendage (LAA) emptying fractions, especially in subjects with higher fibrosis burdens. Fibrotic‐mediated LA motion impairment alters LA and LAA flow near the endocardium and the whole cavity, ultimately leading to more stagnant blood regions in the LAA.


  • Open Access

    Multi-physics simulations reveal hemodynamic impacts of patient-derived fibrosis-related changes in left atrial tissue mechanics

    by Alejandro Gonzalo, Christoph M. Augustin, Savannah F. Bifulco, Åshild Telle, Yaacoub Chahine, Ahmad Kassar, Manuel Guerrero-Hurtado, Eduardo Durán, Pablo Martínez-Legazpi, Oscar Flores, et al.

    Stroke is a leading cause of death and disability worldwide. Atrial myopathy, including fibrosis, is associated with an increased risk of ischemic stroke, but the mechanisms underlying this association are poorly understood. Fibrosis modifies myocardial structure, impairing electrical propagation and tissue biomechanics, and creating stagnant flow regions where clots could form. Fibrosis can be mapped non-invasively using late gadolinium enhancement magnetic resonance imaging (LGE-MRI). However, fibrosis maps are not currently incorporated into stroke risk calculations or computational electro-mechano-fluidic models. We present multi-physics simulations of left atrial (LA) myocardial motion and hemodynamics using patient-specific anatomies and fibrotic maps from LGE-MRI. We modify tissue stiffness and active tension generation in fibrotic regions and investigate how these changes affect LA flow for different fibrotic burdens. We find that fibrotic regions and, to a lesser extent, non-fibrotic regions experience reduced myocardial strain, resulting in decreased LA emptying fraction consistent with clinical observations. Both fibrotic tissue stiffening and hypocontractility independently reduce LA function, but together, these two alterations cause more pronounced effects than either one alone. Fibrosis significantly alters flow patterns throughout the atrial chamber, and particularly, the filling and emptying jets of the left atrial appendage (LAA). The effects of fibrosis in LA flow are largely captured by the concomitant changes in LA emptying fraction except inside the LAA, where a multi-factorial behavior is observed. This work illustrates how high-fidelity, multi-physics models can be used to study thrombogenesis mechanisms in a patient-specific manner, shedding light onto the link between atrial fibrosis and ischemic stroke. Key points Left atrial (LA) fibrosis is associated with arrhythmogenesis and increased risk of ischemic stroke; its extent and pattern can be quantified on a patient-specific basis using late gadolinium enhancement magnetic resonance imaging. Current stroke risk prediction tools have limited personalization, and their accuracy could be improvedfib by incorporating patient-specific information like fibrotic maps and hemodynamic patterns. We present the first electro-mechano-fluidic multi-physics computational simulations of LA flow, including fibrosis and anatomies from medical imaging. Mechanical changes in fibrotic tissue impair global LA motion, decreasing LA and left atrial appendage (LAA) emptying fractions, especially in subjects with higher fibrosis burdens. Fibrotic-mediated LA motion impairment alters LA and LAA flow near the endocardium and the whole cavity, ultimately leading to more stagnant blood regions in the LAA.


  • Open Access

    Pulmonary vein flow split effects in patient-specific simulations of left atrial flow

    by Eduardo Durán, Manuel García-Villalba, Pablo Martínez-Legazpi, Alejandro Gonzalo, Elliot McVeigh, Andrew M. Kahn, Javier Bermejo, Oscar Flores, Juan Carlos del Álamo


  • Open Access

    Efficient multi-fidelity computation of blood coagulation under flow

    by Manuel Guerrero-Hurtado, Manuel Garcia-Villalba, Alejandro Gonzalo, Pablo Martinez-Legazpi, Andy M. Kahn, Elliot McVeigh, Javier Bermejo, Juan C. del Alamo, Oscar Flores

    Clot formation is a crucial process that prevents bleeding, but can lead to severe disorders when imbalanced. This process is regulated by the coagulation cascade, a biochemical network that controls the enzyme thrombin, which converts soluble fibrinogen into the fibrin fibers that constitute clots. Coagulation cascade models are typically complex and involve dozens of partial differential equations (PDEs) representing various chemical species’ transport, reaction kinetics, and diffusion. Solving these PDE systems computationally is challenging, due to their large size and multi-scale nature. We propose a multi-fidelity strategy to increase the efficiency of coagulation cascade simulations. Leveraging the slower dynamics of molecular diffusion, we transform the governing PDEs into ordinary differential equations (ODEs) representing the evolution of species concentrations versus blood residence time. We then Taylor-expand the ODE solution around the zero-diffusivity limit to obtain spatiotemporal maps of species concentrations in terms of the statistical moments of residence time, , and provide the governing PDEs for . This strategy replaces a high-fidelity system of N PDEs representing the coagulation cascade of N chemical species by N ODEs and p PDEs governing the residence time statistical moments. The multi-fidelity order( p ) allows balancing accuracy and computational cost, providing a speedup of over N/p compared to high-fidelity models. Using a simplified coagulation network and an idealized aneurysm geometry with a pulsatile flow as a benchmark, we demonstrate favorable accuracy for low-order models of p = 1 and p = 2. These models depart from the high-fidelity solution by under 16% ( p = 1) and 5% ( p = 2) after 20 cardiac cycles. The favorable accuracy and low computational cost of multi-fidelity models could enable unprecedented coagulation analyses in complex flow scenarios and extensive reaction networks. Furthermore, it can be generalized to advance our understanding of other systems biology networks affected by blood flow.


  • Open Access

    Pulmonary vein flow split effects in patient-specific simulations of left atrial flow

    by Eduardo Durán, Manuel García-Villalba, Pablo Martínez-Legazpi, Alejandro Gonzalo, Elliot McVeigh, Andrew M Kahn, Javier Bermejo, Oscar Flores, Juan Carlos del Alamo

    Disruptions to left atrial (LA) blood flow, such as those caused by atrial fibrillation (AF), can lead to thrombosis in the left atrial appendage (LAA) and an increased risk of systemic embolism. LA hemodynamics are influenced by various factors, including LA anatomy and function, and pulmonary vein (PV) inflow conditions. In particular, the PV flow split can vary significantly among and within patients depending on multiple factors. In this study, we investigated how changes in PV flow split affect LA flow transport, focusing on blood stasis in the LAA, using a high-fidelity patient-specific computational fluid dynamics (CFD) model. We analyzed LA anatomies from eight patients with varying atrial function, including three with AF and either a LAA thrombus or a history of TIAs. Using four different flow splits (60/40% and 55/45% through right and left PVs, even flow rate, and same velocity through each PV), we found that flow patterns are sensitive to PV flow split variations, particularly in planes parallel to the mitral valve. Changes in PV flow split also had a significant impact on blood stasis and could contribute to increased risk for thrombosis inside the LAA, particularly in patients with AF and previous LAA thrombus or a history of TIAs. Our study highlights the importance of considering patient-specific PV flow split variations when assessing LA hemodynamics and identifying patients at increased risk for thrombosis and stroke.