AMAxel C. Moore

Axel C. Moore

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Axel C. Moore has a total of 159 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Stress-relaxation and Failure Properties of Spinal Ligaments in Pigs with and without Scoliosis-like Deformity

    by Christian R D'ANdrea, Mattan R Orbach, Dogerno J Norceide, Madeline S Boyes, Axel Moore, Jacob Jordan, Thomas Schaer, Anita Singh, Patrick Cahill, Edward Vresilovic, et al.

    This study addresses the need for accurate tissue material properties in computational models of the spine. Fundamental to functional spinal unit (FSU) biomechanics are the stress-relaxation and failure properties of the interspinous and intertransverse ligaments (ISL and ITL, respectively). These were measured and compared in normative and scoliotic spines in a Yorkshire pig model. Skeletally immature female pig spines were posterolaterally tethered to induce scoliosis. 23 ISLs and 17 ITLs excised from normative and scoliotic spine segments underwent stress-relaxation and failure tests. Group comparisons tested the effects of scoliosis (magnitude, convexity vs. concavity), spinal level (thoracic, lumbar), and pig age. Scoliosis altered ligament geometry and material behavior. The cross-sectional area of concave ITLs was greater than that of normative ITLs, which was larger than that of convex ITLs. ISL and ITL elastic moduli varied across groups. Scoliotic ISL failure strain was higher than that of the normative ISL, and convex ITL failure strain was higher than that of the normative ITL. The long-term relaxation time of ISLs from scoliotic FSUs was longer than that of normative ISLs. These findings demonstrate differences in dimensions and stress-relaxation and failure material properties of the ISL and ITL associated with scoliosis. Obtained values were comparable to reported human and porcine ligament material properties and were incorporated into an FSU finite element model and shown to affect range of motion. Such property differences may inform quantification of ligament properties with higher sample sizes, related surgical techniques, and further computational modeling.


  • Open Access

    Walking recovers cartilage compressive strain in vivo

    by Shu-Jin Kust, Kyle D. Meadows, Dana Voinier, JiYeon A. Hong, Dawn M. Elliott, Daniel K. White, Axel C. Moore


  • Open Access

    Can axial loading restore in vivo disc geometry, opening pressure, and T2 relaxation time?

    by Harrah R. Newman, Axel C. Moore, Kyle D. Meadows, Rachel L. Hilliard, Madeline S. Boyes, Edward J. Vresilovic, Thomas P. Schaer, Dawn M. Elliott

    Background: Cadaveric intervertebral discs are often studied for a variety of research questions, and outcomes are interpreted in the in vivo context. Unfortunately, the cadaveric disc does not inherently represent the LIVE condition, such that the disc structure (geometry), composition (T2 relaxation time), and mechanical function (opening pressure, OP) measured in the cadaver do not necessarily represent the in vivo disc.Methods: We conducted serial evaluations in the Yucatan minipig of disc geometry, T2 relaxation time, and OP to quantify the changes that occur with progressive dissection and used axial loading to restore the in vivo condition.Results: We found no difference in any parameter from LIVE to TORSO; thus, within 2 h of sacrifice, the TORSO disc can represent the LIVE condition. With serial dissection and sample preparation the disc height increased (SEGMENT height 18% higher than TORSO), OP decreased (POTTED was 67% lower than TORSO), and T2 time was unchanged. With axial loading, an imposed stress of 0.20–0.33 MPa returned the disc to in vivo, LIVE disc geometry and OP, although T2 time was decreased. There was a linear correlation between applied stress and OP, and this was conserved across multiple studies and species.Conclusion: To restore the LIVE disc state in human studies or other animal models, we recommend measuring the OP/stress relationship and using this relationship to select the applied stress necessary to recover the in vivo condition.


  • Open Access

    Quantifying internal intervertebral disc strains to assess nucleus replacement device designs: a digital volume correlation and ultra-high-resolution MRI study

    by Tamanna Rahman, Saman Tavana, Nicoleta Baxan, Kay A. Raftery, George Morgan, Thomas P. Schaer, Nigel Smith, Axel Moore, Jonathan Bull, Molly M. Stevens, et al.

    Introduction: Nucleus replacement has been proposed as a treatment to restore biomechanics and relieve pain in degenerate intervertebral discs (IVDs). Multiple nucleus replacement devices (NRDs) have been developed, however, none are currently used routinely in clinic. A better understanding of the interactions between NRDs and surrounding tissues may provide insight into the causes of implant failure and provide target properties for future NRD designs. The aim of this study was to non-invasively quantify 3D strains within the IVD through three stages of nucleus replacement surgery: intact, post-nuclectomy, and post-treatment.Methods: Digital volume correlation (DVC) combined with 9.4T MRI was used to measure strains in seven human cadaveric specimens (42 ± 18 years) when axially compressed to 1 kN. Nucleus material was removed from each specimen creating a cavity that was filled with a hydrogel-based NRD.Results: Nucleus removal led to loss of disc height (12.6 ± 4.4%, p = 0.004) which was restored post-treatment (within 5.3 ± 3.1% of the intact state, p > 0.05). Nuclectomy led to increased circumferential strains in the lateral annulus region compared to the intact state (−4.0 ± 3.4% vs. 1.7 ± 6.0%, p = 0.013), and increased maximum shear strains in the posterior annulus region (14.6 ± 1.7% vs. 19.4 ± 2.6%, p = 0.021). In both cases, the NRD was able to restore these strain values to their intact levels (p ≥ 0.192).Discussion: The ability of the NRD to restore IVD biomechanics and some strain types to intact state levels supports nucleus replacement surgery as a viable treatment option. The DVC-MRI method used in the present study could serve as a useful tool to assess future NRD designs to help improve performance in future clinical trials.


  • Open Access

    Microfibrous Scaffolds Guide Stem Cell Lumenogenesis and Brain Organoid Engineering

    by Kaja I. Ritzau‐Reid, Sebastien J. P. Callens, Ruoxiao Xie, Martina Cihova, Daniel Reumann, Christopher L. Grigsby, Lino Prados‐Martin, Richard Wang, Axel C. Moore, James P. K. Armstrong, et al.

    3D organoids are widely used as tractable in vitro models capable of elucidating aspects of human development and disease. However, the manual and low‐throughput culture methods, coupled with a low reproducibility and geometric heterogeneity, restrict the scope and application of organoid research. Combining expertise from stem cell biology and bioengineering offers a promising approach to address some of these limitations. Here, melt electrospinning writing is used to generate tuneable grid scaffolds that can guide the self‐organization of pluripotent stem cells into patterned arrays of embryoid bodies. Grid geometry is shown to be a key determinant of stem cell self‐organization, guiding the position and size of emerging lumens via curvature‐controlled tissue growth. Two distinct methods for culturing scaffold‐grown embryoid bodies into either interconnected or spatially discrete cerebral organoids are reported. These scaffolds provide a high‐throughput method to generate, culture, and analyze large numbers of organoids, substantially reducing the time investment and manual labor involved in conventional methods of organoid culture. It is anticipated that this methodological development will open up new opportunities for guiding pluripotent stem cell culture, studying lumenogenesis, and generating large numbers of uniform organoids for high‐throughput screening.


  • Off-Axis Loading Fixture for Spine Biomechanics: Combined Compression and Bending

    by Axel C. Moore, Dione A. Holder, Dawn M. Elliott

    The spine is a multi-tissue musculoskeletal system that supports large multi-axial loads and motions during physiological activities. The healthy and pathological biomechanical function of the spine and its subtissues are generally studied using cadaveric specimens that often require multi-axis biomechanical test systems to mimic the complex loading environment of the spine. Unfortunately, an off-the-shelf device can easily exceed 200,000 USD, while a custom device requires extensive time and experience in mechatronics. Our goal was to develop a cost-appropriate compression and bending (flexion–extension and lateral bending) spine testing system that requires little time and minimal technical knowledge. Our solution was an off-axis loading fixture (OLaF) that mounts to an existing uni-axial test frame and requires no additional actuators. OLaF requires little machining, with most components purchased off-the-shelf, and costs less than 10,000 USD. The only external transducer required is a six-axis load cell. Furthermore, OLaF is controlled using the existing uni-axial test frame's software, while the load data is collected using the software included with the six-axis load cell. Here we provide the design rationale for how OLaF develops primary motions and loads and minimizes off-axis secondary constraints, verify the primary kinematics using motion capture, and demonstrate that the system is capable of applying physiologically relevant, noninjurious, axial compression and bending. While OLaF is limited to compression and bending studies it produces repeatable physiologically relevant biomechanics, with high quality data, and minimal startup costs.


  • Open Access

    Fiber reinforced hydrated networks recapitulate the poroelastic mechanics of articular cartilage

    by A.C. Moore, M.G. Hennessy, L.P. Nogueira, S.J. Franks, M. Taffetani, H. Seong, Y.K. Kang, W.S. Tan, G. Miklosic, R. El Laham, et al.


  • Uneven Respiratory Function Observed With Dynamic Hyperpolarized Xenon-129 MRI in a Pig Thoracic Insufficiency Syndrome Model

    by H. Hamedani, F. Amzajerdian, S. Kadlecek, K. Ruppert, M.K. Ismail, L. Loza, M. Boyes, K. Hopster, R. Hilliard, T. Schaer, et al.