HLHaitao Li

Haitao Li

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Haitao Li has a total of 28 co-authors. Here are the top co-authors by number of shared publications:

  • Chi Ma

    School of Mechanical and Electrical Engineering, Shaanxi University of Science and Technology, Xi’an 710021, China

    2 shared publications
  • Jie Li

    School of Mechanical and Electrical Engineering, Shaanxi University of Science and Technology, Xi’an 710021, China

    2 shared publications
  • Lijun Yang

    School of Mechanical and Electrical Engineering, Shaanxi University of Science and Technology, Xi’an 710021, China

    2 shared publications
  • Yawen Wang

    School of Mechanical and Electrical Engineering, Shaanxi University of Science and Technology, Xi’an 710021, China

    2 shared publications
  • Chenggong Yi

    School of Mechanical and Electrical Engineering, Shaanxi University of Science and Technology, Xi’an, Shaanxi 710021, People’s Republic of China

    1 shared publication
  • Cong Cheng

    School of Mechanical Engineering, Southwest Jiaotong University, Chengdu, China

    1 shared publication

Latest Publications

  • Open Access

    Principle and Method of Base Station Calibration Based on a Physical Standard for Multi-Station Laser Tracking Measurement

    by Haitao Li, Yuanbiao Wang, Yawen Wang, Yunlong Yu, Zehao Wang, Weihao Su, Yehao Zhu, Lijun Yang, Chi Ma, Jie Li, et al.

    In the measurement of volumetric errors in CNC machine tools using multi-station laser tracking technology, the coordinate calibration accuracy of external measurement base stations is a key factor determining the system’s final accuracy. Traditional calibration approaches typically use the commanded positions of the machine tool directly to inversely determine base station coordinates, which results in strong coupling between inherent geometric errors and base station parameters. Consequently, the measurement accuracy cannot be properly evaluated, and metrological traceability of the results remains difficult to achieve. To address this issue, this paper proposes a novel calibration principle based on an independent external physical standard and develops a base station calibrator independently. This device employs a precision turntable, G5-grade precision spheres, and electromagnet groups to construct an equivalent target with four feature points at the spindle end. Verified by a high-precision coordinate measuring machine (CMM), the maximum difference in repeated calibrations of the device is 1.4 µm, indicating its excellent positioning repeatability. The calibrator was further applied to measure the positioning errors of a CNC milling machine, and comparative experiments were performed with a Renishaw XL-80 laser interferometer. The results indicate that the error variation trends obtained from the two measurement principles are highly consistent. In both the X-axis and Y-axis directions, the maximum deviations of linear errors are controlled within 3.7 µm, while the maximum deviations of angular errors remain within 4.6 µrad. Furthermore, the reliability of the system data was confirmed through an uncertainty analysis. The external physical standard developed in this study ensures that base station calibration accuracy is not affected by the inherent errors of the machine tool, providing a novel and reliable scheme for high-precision calibration and metrological traceability of machine tool spatial errors.


  • Open Access

    Efficient High-Precision Measurement for Micro-Orifice Parameters of Impinging Injectors

    by Haitao Li, Yunhong Bai, Yawen Wang, Mengyang Zhang, Yikang Zhang, Lijun Yang, Chi Ma, Jie Li

    Impinging injectors are extensively utilized in liquid rocket engines, characterized by a large number of paired inclined injection orifices. The diameter and axis alignment deviation of these orifices directly influence propellant flow distribution, atomization and mixing behavior, and engine operational stability. To address the challenges associated with micro-sized orifices, inclined axes, large quantities, spatial intersection, and the low detection efficiency of conventional approaches, this paper proposes a dual-line laser 3D point cloud reconstruction-based method for measuring the diameter and impact alignment deviation of injector orifices. A dual-line laser measurement system is established to capture surface point clouds on both sides of the orifice inlets. Through system calibration and point cloud registration, the 3D point cloud data of the injector orifices within a unified coordinate system are reconstructed. Cross-sectional mapping, boundary extraction, and geometric fitting techniques are applied to determine the diameter and axis parameters of the orifices, and the spatial alignment deviation of paired orifices is subsequently calculated. To validate the feasibility of the proposed method, experimental investigation is conducted on test specimens with both 8 pairs of Φ2 mm through-holes and Φ0.5 mm micro-orifices. For the Φ2 mm specimen, the diameter measurement results are compared with industrial computed tomography (CT) data, while the alignment deviation results are verified using a combination of pin gauges and coordinate measuring machine (CMM) measurements. For the Φ0.5 mm micro-orifices, both diameter and alignment deviation results are verified using a 3D coaxial line confocal sensor. After system calibration, the fitting residuals of three Φ8 mm standard spheres are all maintained within 0.08 mm. The diameter measurement results of 8 selected Φ2 mm orifices show good overall agreement with industrial CT data: the maximum absolute deviation is 22 μm, the average absolute deviation is 15 μm, the maximum relative error is 1.09%, and the average relative error is 0.74%. The diameter and alignment deviation results of Φ0.5 mm micro-orifices show good consistency with the 3D coaxial line confocal sensor: the maximum absolute deviation is 13 μm for diameter and 0.047° for alignment deviation, with maximum relative errors of 2.41% and 0.058%, respectively. The alignment deviation results of 8 pairs of Φ2 mm orifices indicate that the proposed dual-line laser method is generally consistent with the combined pin gauge and CMM approach: the maximum absolute deviation is 0.170°, the average absolute deviation is 0.125%, the maximum relative error is 0.284%, and the average relative error is 0.125%. The results demonstrate that the proposed method enables non-contact and high-efficiency measurement of the diameter and alignment angle of injector orifices in impinging injectors for both conventional Φ2 mm orifices and micro Φ0.5 mm orifices, with high measurement accuracy and promising engineering application potential, thereby providing a new technical approach for the geometric parameter inspection of multi-scale micro-injection orifices.

  • A low-cost 3D dynamic measurement system for CNC machine tool geometric errors based on laser interferometry and dual-ballbar

    by Haitao Li, Xiaoning Jing, Yawen Wang, Lijun Yang, Han Li, Chenggong Yi, Yuheng Yang, Xinlei Guo

    In view of the existing three-dimensional laser tracking measurement system for detecting machine tool geometric accuracy, the strong dependence on the coordinate system, the difficulty in tracing the measurement results, and the high equipment cost, this study proposes a new low-cost, high-precision three-dimensional hybrid laser-ballbar measurement system and a supporting measurement method. The system comprises a three-dimensional laser dual ballbar and a reference station calibrator. The dual ballbar integrates the high-precision attributes of a laser interferometer with the dynamic measurement capabilities of a conventional ballbar. The base station calibrator is used as a physical reference to evaluate system errors and trace measurement data. The proposed method realizes the measurement and evaluation of three-dimensional dynamic geometric errors and has good versatility. This paper designs and carries out measurement experiments on the positioning error, straightness error and angular error (pitch and yaw) in the X-axis and Y-axis directions and compares and analyzes them with the measurement results of the laser interferometer. The experimental findings indicate that, over a 300 mm measurement range, the X-axis exhibits a maximum positioning deviation of 1.8 μm, with repeatability exceeding 1.51 μm and an expanded uncertainty between 2.82 and 3.98 μm (k = 2). The straightness deviation remains under 2.9 μm, while the peak angular error is 3.6 μrad. For the Y-axis, the maximum positioning deviation reaches 2.3 μm, repeatability is better than 1.5 μm, and the expanded uncertainty lies between 3.14 and 3.88 μm (k = 2). The straightness deviation does not exceed 3.7 μm, and the angular error peaks at 4.6 μrad. These outcomes validate the precision and reliability of the developed measurement system in assessing geometric errors of machine tools, highlighting its promising applicability in engineering contexts.


  • Identification of geometric deviations inherent to multi-axis machine tools based on the pose measurement principle

    by Li Haitao, Guo Junjie, Deng Yufen, Wang Jindong, He Xinrong

    The laser tracker is an effective instrument for measuring 3D relative displacement in a work volume because its attitude can be freely changed. This paper presents a novel principle to realize the precise calibration of a numerical control (NC) machine tool accurately and quickly; this is the 'pose measurement principle', for measuring errors. We also introduce an algorithm for identifying geometric deviations. A NC precise table mounted on a motion axis and a laser tracker are used for the coordinate determination of three fixed points to obtain the pose information of each motion axis, then calculate the pose deviations, and finally identify all the errors. For the error identification, first, according to the definition of geometric errors, we extend the concept of pose deviations, and represent the six geometric errors using a position deviation vector and attitude deviation vector. Next, we geometrically identify the three angular errors and linear errors in order; the error mathematical model for the linear axis and rotary axis are developed, respectively. Moreover, the validity of the calibration algorithm for the base station, measuring points and identification of errors are confirmed by simulations. In the end, the proposed method is applied to a three-axis NC milling machine tool and a rotary table, and then the geometric deviations are identified successfully in 3 h and 2.5 h, respectively. Comparative experiments by means of other instruments also agree well with the proposed method. Thus, the proposed method can be applied to the measurement of the multi-axis machine tool.