Etienne Liénard
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Etienne Liénard has a total of 97 co-authors. Here are the top co-authors by number of shared publications:
- Xavier Flechard
Université de Caen Normandie
15 shared publications G. Ban
Normandie Univ, ENSICAEN, UNICAEN, CNRS/IN2P3, LPC Caen
9 shared publicationsD. Durand
LPC Caen ENSICAEN Université de Caen CNRS/IN2P3 Caen France
8 shared publications- Jean-Charles Thomas
Grand Accélérateur National d'Ions Lourds
8 shared publications F. Mauger
LPC Caen ENSICAEN Université de Caen CNRS/IN2P3 Caen France
7 shared publications- Gilles Quemener
Laboratoire de Physique Corpusculaire Caen
7 shared publications
Latest Publications
- 9 February 2026
- Published by American Physical Society (APS) in Physical Review C
- Vol. 113 (2)
Backscattering study of electrons from 0.1 to 3.4 MeV
- 9 February 2026
- Published by American Physical Society (APS) in Physical Review C
- Vol. 113 (2)
Backscattering study of electrons from 0.1 to 3.4 MeV
- Open Access
- 21 February 2023
- Published by Elsevier in Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment
- Vol. 1050
Experimental setup for Weak Interaction Studies with Radioactive ion-beams WISArD
- 21 February 2023
- Published by Elsevier in Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment
- Vol. 1050
Open AccessExperimental setup for Weak Interaction Studies with Radioactive ion-beams WISArD
- 21 October 2022
- Published by American Physical Society (APS) in Physical Review C
- Vol. 106 (4) , 045502
High-precision measurement of the half-lifeThe half-life of has been measured using a low-energy radioactive beam implanted in an Ce-doped inorganic scintillator and recording decay events in a geometry. Events were time-stamped with a digital data acquisition system enabling a reliable control of dead-time effects and detector gain variations. The result, ) ms, provides the most precise value obtained so far and is consistent with the only previous measurement having a precision smaller than 0.1%. This resolves the long-standing discrepancy previously observed between two sets of measurements.- 21 October 2022
- Published by American Physical Society (APS) in Physical Review C
- Vol. 106 (4) , 045502
High-precision measurement of the half-lifeThe half-life of has been measured using a low-energy radioactive beam implanted in an Ce-doped inorganic scintillator and recording decay events in a geometry. Events were time-stamped with a digital data acquisition system enabling a reliable control of dead-time effects and detector gain variations. The result, ) ms, provides the most precise value obtained so far and is consistent with the only previous measurement having a precision smaller than 0.1%. This resolves the long-standing discrepancy previously observed between two sets of measurements.- 5 June 2020
- Published by Springer Nature in The European Physical Journal A
- Vol. 56 (6) , 1-14
Geometry optimisation of a transparent axisymmetric ion trap for the MORA project
- 5 June 2020
- Published by Springer Nature in The European Physical Journal A
- Vol. 56 (6) , 1-14
Geometry optimisation of a transparent axisymmetric ion trap for the MORA project
- Open Access
Geometry optimisation of a transparent axisymmetric ion trap for the MORA project
In the frame of the project MORA (Matter's Origin from the Radio Activity of trapped and oriented ions), a transparent axially symmetric radio-frequency ion trap (MORATrap) was designed in order to measure the triple correlation parameter $D$ in nuclear $\beta-$decay of laser-polarised ions. The trap design was inspired from the LPCTrap geometry, operated at GANIL from 2005 to 2013. In a real (non-ideal) Paul trap, the quadrupole electric potential is not perfect leading to instabilities in ion motion and therefore affecting the overall trapping efficiency. This paper presents a numerical method aiming to optimise the geometry of a trap. It is applied to MORATrap in order to improve the trapping efficiency and to enlarge the axial transparent solid angle compared to LPCTrap. In the whole optimisation process, numerical computation of electric potential and field was carried out using an electrostatic solver based on boundary element method (BEM). The optimisation consisted in minimising an objective function (fitness function) depending on higher order multipoles of the potential. Finally, systematic changes of trap dimensions and electrode displacements were applied to investigate geometrical effects on the potential quality.Open AccessGeometry optimisation of a transparent axisymmetric ion trap for the MORA project
In the frame of the project MORA (Matter's Origin from the Radio Activity of trapped and oriented ions), a transparent axially symmetric radio-frequency ion trap (MORATrap) was designed in order to measure the triple correlation parameter $D$ in nuclear $\beta-$decay of laser-polarised ions. The trap design was inspired from the LPCTrap geometry, operated at GANIL from 2005 to 2013. In a real (non-ideal) Paul trap, the quadrupole electric potential is not perfect leading to instabilities in ion motion and therefore affecting the overall trapping efficiency. This paper presents a numerical method aiming to optimise the geometry of a trap. It is applied to MORATrap in order to improve the trapping efficiency and to enlarge the axial transparent solid angle compared to LPCTrap. In the whole optimisation process, numerical computation of electric potential and field was carried out using an electrostatic solver based on boundary element method (BEM). The optimisation consisted in minimising an objective function (fitness function) depending on higher order multipoles of the potential. Finally, systematic changes of trap dimensions and electrode displacements were applied to investigate geometrical effects on the potential quality. - 7 January 2020
- Published by Springer Nature
- p. 903-909
Investigating Shakeoff Process in Precise Correlation Measurements in Nuclear β Decay
- 7 January 2020
- Published by Springer Nature
- p. 903-909
Investigating Shakeoff Process in Precise Correlation Measurements in Nuclear β Decay
- Open Access
- 29 June 2019
- Published by Springer Nature in The European Physical Journal A
- Vol. 55 (6) , 101
The open LPC Paul trap for precision measurements in beta decay
- 29 June 2019
- Published by Springer Nature in The European Physical Journal A
- Vol. 55 (6) , 101
Open AccessThe open LPC Paul trap for precision measurements in beta decay
- Open Access
- 1 January 2018
- Published by OpenEdition in ArchéoSciences
- Vol. 42-2 (42-2) , 45-62
Appréhender le stock de métal monnayé au ive siècle après J.-C.
Parmi les thématiques abordées en numismatique à l’aide de l’archéométrie, les recherches spécifiques sur le stock de métal monnayé au ive siècle s’avèrent fascinantes mais délicates. Afflux de nouvelles ressources métalliques, refontes volontaires de monnaies : tous ces phénomènes sont de grande conséquence pour les monnayages produits dans les différents ateliers de l’Empire romain tardif. Certaines données de ce type sont mesurables. Les alliages métalliques (donc ici monétaires) contiennent en effet des éléments mineurs ou en traces, constituant la « carte d’identité » de l’approvisionnement des ateliers monétaires. Il y a 10 ans Isabelle Bollard et Jean-Noël Barrandon réunissaient plusieurs analyses de monnaies en alliage cuivreux émises au cours du ive siècle. Nos propres observations, obtenues dans le cadre d’un projet de recherche financé par la région Normandie (intitulé FANUM), sur 14 528 monnaies (nummi) de la période constantinienne contenues dans un trésor découvert fortuitement à Saint-Germain-de-Varreville (Manche), nous ont incités à reprendre, de façon plus approfondie, l’étude des alliages utilisés au cours de cette période, en portant notamment notre attention sur les teneurs en or et en argent. En effet, la grande variété des ateliers représentés au sein du trésor favorisait idéalement une telle enquête. Le choix de la fluorescence X portable a permis d’élaborer un protocole d’analyse précis et adapté à un grand nombre de monnaies. L’exploitation de 774 analyses réalisées sur des nummi frappés dans les ateliers occidentaux a permis de compléter les travaux antérieurs, mais également de mettre en évidence l’utilisation de stocks métalliques différents à partir des années 320.
- 1 January 2018
- Published by OpenEdition in ArchéoSciences
- Vol. 42-2 (42-2) , 45-62
Open AccessAppréhender le stock de métal monnayé au ive siècle après J.-C.
Parmi les thématiques abordées en numismatique à l’aide de l’archéométrie, les recherches spécifiques sur le stock de métal monnayé au ive siècle s’avèrent fascinantes mais délicates. Afflux de nouvelles ressources métalliques, refontes volontaires de monnaies : tous ces phénomènes sont de grande conséquence pour les monnayages produits dans les différents ateliers de l’Empire romain tardif. Certaines données de ce type sont mesurables. Les alliages métalliques (donc ici monétaires) contiennent en effet des éléments mineurs ou en traces, constituant la « carte d’identité » de l’approvisionnement des ateliers monétaires. Il y a 10 ans Isabelle Bollard et Jean-Noël Barrandon réunissaient plusieurs analyses de monnaies en alliage cuivreux émises au cours du ive siècle. Nos propres observations, obtenues dans le cadre d’un projet de recherche financé par la région Normandie (intitulé FANUM), sur 14 528 monnaies (nummi) de la période constantinienne contenues dans un trésor découvert fortuitement à Saint-Germain-de-Varreville (Manche), nous ont incités à reprendre, de façon plus approfondie, l’étude des alliages utilisés au cours de cette période, en portant notamment notre attention sur les teneurs en or et en argent. En effet, la grande variété des ateliers représentés au sein du trésor favorisait idéalement une telle enquête. Le choix de la fluorescence X portable a permis d’élaborer un protocole d’analyse précis et adapté à un grand nombre de monnaies. L’exploitation de 774 analyses réalisées sur des nummi frappés dans les ateliers occidentaux a permis de compléter les travaux antérieurs, mais également de mettre en évidence l’utilisation de stocks métalliques différents à partir des années 320.
- Open Access
Precision measurements with LPCTrap at GANIL
The experimental achievements and the results obtained so far with the LPCTrap device installed at GANIL are presented. The apparatus is dedicated to the study of the weak interaction at low energy by means of precise measurements of the BETA-NU angular correlation parameter in nuclear BETA decays. So far, the data collected with three isotopes have enabled to determine, for the first time, the charge state distributions of the recoiling ions, induced by shakeoff process. The analysis is presently refined to deduce the correlation parameters, with the potential of improving both the constraint deduced at low energy on exotic tensor currents (6He1+) and the precision on the V u d element of the quark-mixing matrix (35Ar1+ and 19Ne1+) deduced from the mirror transitions dataset.
Open AccessPrecision measurements with LPCTrap at GANIL
The experimental achievements and the results obtained so far with the LPCTrap device installed at GANIL are presented. The apparatus is dedicated to the study of the weak interaction at low energy by means of precise measurements of the BETA-NU angular correlation parameter in nuclear BETA decays. So far, the data collected with three isotopes have enabled to determine, for the first time, the charge state distributions of the recoiling ions, induced by shakeoff process. The analysis is presently refined to deduce the correlation parameters, with the potential of improving both the constraint deduced at low energy on exotic tensor currents (6He1+) and the precision on the V u d element of the quark-mixing matrix (35Ar1+ and 19Ne1+) deduced from the mirror transitions dataset.
- Open Access
- 14 July 2015
- Published by Springer Nature
- p. 1-7
Precision measurements with LPCTrap at GANIL
- 14 July 2015
- Published by Springer Nature
- p. 1-7
Open AccessPrecision measurements with LPCTrap at GANIL