Mahen Mahendran
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Mahen Mahendran has a total of 130 co-authors. Here are the top co-authors by number of shared publications:
- Anthony Ariyanayagam
Centre for Materials Science, Faculty of Engineering, Queensland University of Technology (QUT), Brisbane 4000, Australia
49 shared publications - Poologanathan Keerthan
Northumbria University
35 shared publications Poologanathan Keerthan
17 shared publications- Shanmuganathan Gunalan
Griffith University
14 shared publications Sivakumar Kesawan
Research Fellow, School of Civil and Environmental Engineering, Queensland Univ. of Technology, Brisbane, QLD 4000, Australia
13 shared publicationsMayooran Sivapathasundaram
Queensland Univ Technol, Brisbane, Qld, Australia
10 shared publications
Latest Publications
- Open Access
- 28 August 2026
- Published by Elsevier in International Journal of Disaster Risk Reduction
- Vol. 144
Development and evaluation of an AI-based framework for bushfire vulnerability assessment of buildings
- 28 August 2026
- Published by Elsevier in International Journal of Disaster Risk Reduction
- Vol. 144
Open AccessDevelopment and evaluation of an AI-based framework for bushfire vulnerability assessment of buildings
- Open Access
- 5 August 2026
- Published by Elsevier in Structures
- Vol. 92
Fire resistance tests of light steel floor–ceiling systems using steel sheet-laminated gypsum plasterboards
- 5 August 2026
- Published by Elsevier in Structures
- Vol. 92
Open AccessFire resistance tests of light steel floor–ceiling systems using steel sheet-laminated gypsum plasterboards
- Open Access
- 12 June 2026
- Published by Elsevier in Fire Safety Journal
- Vol. 164
Fire resistance behaviour of LSF walls with non-fire rated wall cleat connections
- 12 June 2026
- Published by Elsevier in Fire Safety Journal
- Vol. 164
Open AccessFire resistance behaviour of LSF walls with non-fire rated wall cleat connections
- Open Access
- 31 March 2026
- Published by Elsevier in Structures
- Vol. 87
Numerical studies and design of cold-formed steel battens subject to pull-through failures under bushfire conditions
- 31 March 2026
- Published by Elsevier in Structures
- Vol. 87
Open AccessNumerical studies and design of cold-formed steel battens subject to pull-through failures under bushfire conditions
- Open Access
- 25 March 2026
- Published by Elsevier in Fire Safety Journal
- Vol. 163
Investigation of plasterboard fall-off in lightweight floor systems under fire conditions
- 25 March 2026
- Published by Elsevier in Fire Safety Journal
- Vol. 163
Open AccessInvestigation of plasterboard fall-off in lightweight floor systems under fire conditions
- Open Access
- 18 March 2026
- Published by Elsevier in Thin-Walled Structures
- Vol. 225
Experimental study of pull-through failures in cold-formed steel battens under combined wind and elevated temperature conditions
- 18 March 2026
- Published by Elsevier in Thin-Walled Structures
- Vol. 225
Open AccessExperimental study of pull-through failures in cold-formed steel battens under combined wind and elevated temperature conditions
- Open Access
- 9 December 2025
- Published by SAGE Publications in Advances in Structural Engineering
Predicting the pull-through capacity of crest-fixed trapezoidal cladding with closely spaced ribs subject to localised dimpling and splitting failures
Crest-fixed trapezoidal cold-formed steel (CFS) cladding systems, widely used in Australia and neighbouring countries, are prone to localized pull-through failures around screw fasteners under high wind uplift/suction loading. Unlike corrugated cladding, which exhibits localized dimpling-type failures, and trapezoidal cladding with wide pans, which often fails through transverse splitting, trapezoidal cladding with closely spaced ribs can experience either localized dimpling or splitting-type pull-through failures. These failures result from significant stress concentrations beneath screw heads and the limited ductility of high-strength steel, posing challenges for accurate prediction through analytical methods. As a result, the design of crest-fixed trapezoidal cladding with closely spaced ribs relies on experimental testing, with few design guidelines available to address these specific failure modes and pull-through capacity. This study proposes and calibrates a ductile damage material model specifically for very thin, high-strength cold-formed steel, enabling accurate simulation of damage initiation, progression, and fracture. The model was implemented in an advanced finite element framework capable of reproducing both localized dimpling and transverse splitting pull-through failures under static wind uplift loading. Validation against experimental data showed excellent accuracy with a low coefficient of variation of 0.02, while an extensive parametric study identified the effects of key parameters such as crest height that increased the capacity by up to 90%. The findings improve the understanding of pull-through behaviour and lead to practical design recommendations for optimising crest-fixed trapezoidal cladding systems. The proposed equation predicted the capacities within 5%, demonstrating strong potential for design-code adoption.
- 9 December 2025
- Published by SAGE Publications in Advances in Structural Engineering
Open AccessPredicting the pull-through capacity of crest-fixed trapezoidal cladding with closely spaced ribs subject to localised dimpling and splitting failures
Crest-fixed trapezoidal cold-formed steel (CFS) cladding systems, widely used in Australia and neighbouring countries, are prone to localized pull-through failures around screw fasteners under high wind uplift/suction loading. Unlike corrugated cladding, which exhibits localized dimpling-type failures, and trapezoidal cladding with wide pans, which often fails through transverse splitting, trapezoidal cladding with closely spaced ribs can experience either localized dimpling or splitting-type pull-through failures. These failures result from significant stress concentrations beneath screw heads and the limited ductility of high-strength steel, posing challenges for accurate prediction through analytical methods. As a result, the design of crest-fixed trapezoidal cladding with closely spaced ribs relies on experimental testing, with few design guidelines available to address these specific failure modes and pull-through capacity. This study proposes and calibrates a ductile damage material model specifically for very thin, high-strength cold-formed steel, enabling accurate simulation of damage initiation, progression, and fracture. The model was implemented in an advanced finite element framework capable of reproducing both localized dimpling and transverse splitting pull-through failures under static wind uplift loading. Validation against experimental data showed excellent accuracy with a low coefficient of variation of 0.02, while an extensive parametric study identified the effects of key parameters such as crest height that increased the capacity by up to 90%. The findings improve the understanding of pull-through behaviour and lead to practical design recommendations for optimising crest-fixed trapezoidal cladding systems. The proposed equation predicted the capacities within 5%, demonstrating strong potential for design-code adoption.
- Open Access
- 8 October 2025
- Published by Emerald Publishing in Journal of Structural Fire Engineering
- Vol. 16 (4) , 544-565
Experimental research on using diatomite aggregate in hollow masonry blocks for bushfire resistance
Purpose: This paper investigates the influence of using a lightweight aggregate called “Diatomite” in hollow masonry (i.e. cement) blocks for bushfire resistance. Design/methodology/approach: One of the 100-block series category (i.e. 90 mm thick) hollow masonry blocks were fabricated using a diatomite fine aggregate-based cement mix (i.e. cement-sand-diatomite mix). Properties of the mixed ingredients were determined, and the cement-sand-diatomite mix were developed based on the absolute volume method. After 28 days of curing, tests were conducted on hollow blocks, including density, compressive strength, bushfire and building fire resistance, and the results were compared with those of the cement-sand (standard) mix hollow block and one of the commercially available hollow blocks. Findings: The newly developed diatomite mix hollow block satisfies the density requirement for ultra-lightweight masonry units and the strength requirement for loadbearing hollow masonry units. It is the only block that complied with the temperature limit for unguarded interior surfaces of bushfire shelters and showed one-hour additional building fire resistance (−/120/120) than that of cement-sand mix (−/60/60) and commercial hollow blocks (−/60/60). Practical implications: The diatomite mix hollow block developed in this research can be suggested as a suitable loadbearing lightweight hollow masonry block for bushfire shelters and external walls of the buildings in bushfire-prone areas. Originality/value: Limited studies are available for hollow masonry blocks in relation to their bushfire and building fire resistance.
- 8 October 2025
- Published by Emerald Publishing in Journal of Structural Fire Engineering
- Vol. 16 (4) , 544-565
Open AccessExperimental research on using diatomite aggregate in hollow masonry blocks for bushfire resistance
Purpose: This paper investigates the influence of using a lightweight aggregate called “Diatomite” in hollow masonry (i.e. cement) blocks for bushfire resistance. Design/methodology/approach: One of the 100-block series category (i.e. 90 mm thick) hollow masonry blocks were fabricated using a diatomite fine aggregate-based cement mix (i.e. cement-sand-diatomite mix). Properties of the mixed ingredients were determined, and the cement-sand-diatomite mix were developed based on the absolute volume method. After 28 days of curing, tests were conducted on hollow blocks, including density, compressive strength, bushfire and building fire resistance, and the results were compared with those of the cement-sand (standard) mix hollow block and one of the commercially available hollow blocks. Findings: The newly developed diatomite mix hollow block satisfies the density requirement for ultra-lightweight masonry units and the strength requirement for loadbearing hollow masonry units. It is the only block that complied with the temperature limit for unguarded interior surfaces of bushfire shelters and showed one-hour additional building fire resistance (−/120/120) than that of cement-sand mix (−/60/60) and commercial hollow blocks (−/60/60). Practical implications: The diatomite mix hollow block developed in this research can be suggested as a suitable loadbearing lightweight hollow masonry block for bushfire shelters and external walls of the buildings in bushfire-prone areas. Originality/value: Limited studies are available for hollow masonry blocks in relation to their bushfire and building fire resistance.
- Open Access
Influence of Web-Perforated Cold-Formed Steel Studs on the Heat Transfer Properties of LSF External Walls
Thermal bridging through cold-formed steel (CFS) studs significantly reduces the thermal performance of light gauge steel frame (LSF) wall systems, particularly in climates demanding higher thermal resistance (R-value). While thermal breaks are commonly used, they increase material costs and construction complexity. According to NCC 2022, the minimum total R-value requirement for external walls ranges between 2.8 and 3.8 m2·K/W depending on the climate zone and building class. This study therefore evaluated web-perforated steel studs as a passive strategy to enhance thermal resistance of LSF walls, analysing 120 configurations with validated 3D finite element models in Abaqus and benchmarking in THERM. The results showed that web perforations consistently improved R-values by 14 to 20%, as isotherm contours and heat flux vectors demonstrated disruption of direct heat flow through the stud, thereby mitigating thermal bridging. Although the axial compression capacity of web-perforated CFS studs decreased by 29.5%, the use of 4 mm hole-edge stiffeners restored 96.8% of the original capacity. The modified NZS 4214:2006 and ASHRAE Modified Zone methods, incorporating steel area reduction and heat flux redistribution, closely matched Abaqus predictions, with coefficients of variation (COV) below 0.009, corresponding to less than 1% relative deviation between analytical and numerical R-values. Furthermore, application of web-perforated CFS studs in five external wall systems demonstrated improved thermal resistance, ensuring compliance with NCC 2022 R-value requirements across all Australian climate zones. Overall, the findings establish web-perforated studs as an effective solution for improving the energy performance of LSF building envelopes.
Open AccessInfluence of Web-Perforated Cold-Formed Steel Studs on the Heat Transfer Properties of LSF External Walls
Thermal bridging through cold-formed steel (CFS) studs significantly reduces the thermal performance of light gauge steel frame (LSF) wall systems, particularly in climates demanding higher thermal resistance (R-value). While thermal breaks are commonly used, they increase material costs and construction complexity. According to NCC 2022, the minimum total R-value requirement for external walls ranges between 2.8 and 3.8 m2·K/W depending on the climate zone and building class. This study therefore evaluated web-perforated steel studs as a passive strategy to enhance thermal resistance of LSF walls, analysing 120 configurations with validated 3D finite element models in Abaqus and benchmarking in THERM. The results showed that web perforations consistently improved R-values by 14 to 20%, as isotherm contours and heat flux vectors demonstrated disruption of direct heat flow through the stud, thereby mitigating thermal bridging. Although the axial compression capacity of web-perforated CFS studs decreased by 29.5%, the use of 4 mm hole-edge stiffeners restored 96.8% of the original capacity. The modified NZS 4214:2006 and ASHRAE Modified Zone methods, incorporating steel area reduction and heat flux redistribution, closely matched Abaqus predictions, with coefficients of variation (COV) below 0.009, corresponding to less than 1% relative deviation between analytical and numerical R-values. Furthermore, application of web-perforated CFS studs in five external wall systems demonstrated improved thermal resistance, ensuring compliance with NCC 2022 R-value requirements across all Australian climate zones. Overall, the findings establish web-perforated studs as an effective solution for improving the energy performance of LSF building envelopes.
- Open Access
- 22 September 2025
- Published by Elsevier in Thin-Walled Structures
- Vol. 218
Improving the fire resistance of light steel floor–ceiling systems through enhanced materials and construction methods
- 22 September 2025
- Published by Elsevier in Thin-Walled Structures
- Vol. 218
Open AccessImproving the fire resistance of light steel floor–ceiling systems through enhanced materials and construction methods