Nieves Martell-Claros
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Nieves Martell-Claros has a total of 94 co-authors. Here are the top co-authors by number of shared publications:
María Abad-Cardiel
Hospital Clinico San Carlos
5 shared publications- Vicente Francisco Gil-Guillén
Clinical Medicine Department, Miguel Hernandez University, 03550 San Juan de Alicante, Alicante, Spain
4 shared publications Arturo Fernandez-Cruz
Unidad de Hipertensión, Hospital Clínico San Carlos, Madrid, Spain
3 shared publicationsBeatriz Alvarez-Alvarez
Hospital Clinico San Carlos
3 shared publications- Emilio Márquez Contreras
Centro de Salud la Orden, Huelva, España
3 shared publications - Josep Franch-Nadal
Centro de Investigación Biomédica en Red de Diabetes y Enfermedades Metabólicas Asociadas (CIBERDEM), Instituto de Salud Carlos III, 28029 Madrid, Spain
3 shared publications
Latest Publications
- 26 January 2018
- Published by Springer Nature
- p. 513-524
Primary Aldosteronism and Its Various Scenarios
- 26 January 2018
- Published by Springer Nature
- p. 513-524
Primary Aldosteronism and Its Various Scenarios
- Open Access
- 26 November 2015
- Published by PeerJ in PeerJ Preprints
Validation of the electronic prescription as a method of measurement of treatment adherence in hypertension
Background. The diagnosis of non-adherence is complex and there are no completely reliable methods that can be used widely in daily practice. The aim of this study was to validate electronic prescriptions as a method of measuring treatment adherence in patients with mild-moderate hypertension. Methods. We conducted a prospective, longitudinal, multicenter study in primary care centers. The study involved 120 patients treated for hypertension and included in the electronic prescription program of the centers. Five visits were made: initial, 6, 12, 18 and 24 months. Adherence was measured using an electronic monitor [medication event monitoring system (MEMS)] and through the electronic prescription program. We calculated the adherence rate (AR) using the MEMS and the electronic prescriptions, with the Medication Possession Ratio (MPR). Adherent patients were considered to be those whose AR was 80-100%. To validate the electronic prescription, its data were compared to the pill count by MEMS (Method of certainty). Sensitivity, specificity, positive (PPV) and negative (NPV) predictive values, and positive (LR+) and negative (LR-) likelihood ratios were calculated. The Kappa concordance index and the area under the ROC curve were also determined. Results. The study was completed by 108 patients (mean age 61.06 years, SD 9.08). Adherence was 77.4% by MEMS (95% CI: 66.8-88%) and 80.4% (95% CI=70.3-90.5) by MPR. At 24 months the sensitivity was 87%, specificity 93.7%, PPV 80%, NPV 96.1%, LR+ 13.8 and LR- 0.1. The K was 0.782 and the AUC was 0.903 (95% CI: 0.817-0.989). Therapeutic complexity was associated with pharmacological non-adherence (OR=1.35, pDiscussion. The electronic prescription was an excellent method to measure non-adherence in hypertensive patients included in this program for over two years. Therapeutic simplicity improved treatment adherence.
- 26 November 2015
- Published by PeerJ in PeerJ Preprints
Open AccessValidation of the electronic prescription as a method of measurement of treatment adherence in hypertension
Background. The diagnosis of non-adherence is complex and there are no completely reliable methods that can be used widely in daily practice. The aim of this study was to validate electronic prescriptions as a method of measuring treatment adherence in patients with mild-moderate hypertension. Methods. We conducted a prospective, longitudinal, multicenter study in primary care centers. The study involved 120 patients treated for hypertension and included in the electronic prescription program of the centers. Five visits were made: initial, 6, 12, 18 and 24 months. Adherence was measured using an electronic monitor [medication event monitoring system (MEMS)] and through the electronic prescription program. We calculated the adherence rate (AR) using the MEMS and the electronic prescriptions, with the Medication Possession Ratio (MPR). Adherent patients were considered to be those whose AR was 80-100%. To validate the electronic prescription, its data were compared to the pill count by MEMS (Method of certainty). Sensitivity, specificity, positive (PPV) and negative (NPV) predictive values, and positive (LR+) and negative (LR-) likelihood ratios were calculated. The Kappa concordance index and the area under the ROC curve were also determined. Results. The study was completed by 108 patients (mean age 61.06 years, SD 9.08). Adherence was 77.4% by MEMS (95% CI: 66.8-88%) and 80.4% (95% CI=70.3-90.5) by MPR. At 24 months the sensitivity was 87%, specificity 93.7%, PPV 80%, NPV 96.1%, LR+ 13.8 and LR- 0.1. The K was 0.782 and the AUC was 0.903 (95% CI: 0.817-0.989). Therapeutic complexity was associated with pharmacological non-adherence (OR=1.35, pDiscussion. The electronic prescription was an excellent method to measure non-adherence in hypertensive patients included in this program for over two years. Therapeutic simplicity improved treatment adherence.
- 1 October 2014
- Published by Wolters Kluwer Health in Journal Of Hypertension
- Vol. 32 (10) , 2101
Contribution of the ABP-International study to the definition of night-time tachycardia
- 1 October 2014
- Published by Wolters Kluwer Health in Journal Of Hypertension
- Vol. 32 (10) , 2101
Contribution of the ABP-International study to the definition of night-time tachycardia
- 1 January 2013
- Published by Elsevier in Revista Española de Cardiología (English Edition)
- Vol. 66 (1) , 47-52
Hipertensión por hiperaldosteronismo: más lesión cardiaca, mayor riesgo cardiovascular
- 1 January 2013
- Published by Elsevier in Revista Española de Cardiología (English Edition)
- Vol. 66 (1) , 47-52
Hipertensión por hiperaldosteronismo: más lesión cardiaca, mayor riesgo cardiovascular
- 1 January 2013
- Published by Elsevier in Revista Española de Cardiología (English Edition)
- Vol. 66 (1) , 47-52
Hypertension Caused by Primary Hyperaldosteronism: Increased Heart Damage and Cardiovascular Risk
- 1 January 2013
- Published by Elsevier in Revista Española de Cardiología (English Edition)
- Vol. 66 (1) , 47-52
Hypertension Caused by Primary Hyperaldosteronism: Increased Heart Damage and Cardiovascular Risk
- 1 January 2013
- Published by Wolters Kluwer Health in Journal Of Hypertension
- Vol. 31 (1) , 103-108
Association between urinary albumin excretion and both central and peripheral blood pressure in subjects with insulin resistance
Background: Central blood pressure (cBP) predicts cardiovascular events. Regarding subclinical organ damage, the relationship between urinary albumin excretion (UAE) and cBP is rather unknown. Objective: We aimed to determine whether cBP is related to UAE, and if this relationship is stronger than that observed with peripheral blood pressure (pBP). Methods: Three hundred and twenty-four hypertensives (61% men, aged 65 ± 10 years) with insulin-resistance (77% diabetics; 23% nondiabetics with metabolic syndrome) were studied. Office pBP and cBP (radial applanation tonometry) were determined. UAE (albumin/creatinine) was averaged from three first-morning-void urine samples. Differences between patients with/without microalbuminuria, and the relationship between UAE and both pBP and cBP were analyzed. The strength of such relationship (cBP vs. pBP) was compared using a noninferiority test. Results: Microalbuminuria was detected in 25% of all patients. After age-adjustment and sex-adjustment, both central and peripheral SBP and pulse pressure (PP) (mmHg) were higher in microalbuminurics than in normoalbuminurics [central SBP (cSBP): 130 ± 20 vs. 124 ± 19; peripheral (pSBP): 147 ± 22 vs. 139 ± 20; central pulse pressure (cPP): 52 ± 15 vs. 47 ± 14; peripheral pulse pressure (pPP): 67 ± 16 vs. 62 ± 16, P < 0.05 for all]. Partial correlation coefficients (age-adjusted and sex-adjusted) between blood pressure (BP) and UAE were 0.175 for cSBP, 0.143 for pSBP, 0.124 for cPP (P < 0.05 for all), and 0.092 for pPP (P = 0.117). Neither cBP nor pBP were superior to each other in their association with UAE or with microalbuminuria. Comparisons between cBP and pBP by means of noninferiority tests revealed no differences in the magnitude of correlation coefficients (P = 0.265 for SBP; P = 0.212 for PP), or differences in means between patients with/without microalbuminuria (P = 0.327 for SBP; P = 0.054 for PP). Conclusion: Although cBP is related with UAE, this relationship is not superior to that of office peripheral BP.
- 1 January 2013
- Published by Wolters Kluwer Health in Journal Of Hypertension
- Vol. 31 (1) , 103-108
Association between urinary albumin excretion and both central and peripheral blood pressure in subjects with insulin resistance
Background: Central blood pressure (cBP) predicts cardiovascular events. Regarding subclinical organ damage, the relationship between urinary albumin excretion (UAE) and cBP is rather unknown. Objective: We aimed to determine whether cBP is related to UAE, and if this relationship is stronger than that observed with peripheral blood pressure (pBP). Methods: Three hundred and twenty-four hypertensives (61% men, aged 65 ± 10 years) with insulin-resistance (77% diabetics; 23% nondiabetics with metabolic syndrome) were studied. Office pBP and cBP (radial applanation tonometry) were determined. UAE (albumin/creatinine) was averaged from three first-morning-void urine samples. Differences between patients with/without microalbuminuria, and the relationship between UAE and both pBP and cBP were analyzed. The strength of such relationship (cBP vs. pBP) was compared using a noninferiority test. Results: Microalbuminuria was detected in 25% of all patients. After age-adjustment and sex-adjustment, both central and peripheral SBP and pulse pressure (PP) (mmHg) were higher in microalbuminurics than in normoalbuminurics [central SBP (cSBP): 130 ± 20 vs. 124 ± 19; peripheral (pSBP): 147 ± 22 vs. 139 ± 20; central pulse pressure (cPP): 52 ± 15 vs. 47 ± 14; peripheral pulse pressure (pPP): 67 ± 16 vs. 62 ± 16, P < 0.05 for all]. Partial correlation coefficients (age-adjusted and sex-adjusted) between blood pressure (BP) and UAE were 0.175 for cSBP, 0.143 for pSBP, 0.124 for cPP (P < 0.05 for all), and 0.092 for pPP (P = 0.117). Neither cBP nor pBP were superior to each other in their association with UAE or with microalbuminuria. Comparisons between cBP and pBP by means of noninferiority tests revealed no differences in the magnitude of correlation coefficients (P = 0.265 for SBP; P = 0.212 for PP), or differences in means between patients with/without microalbuminuria (P = 0.327 for SBP; P = 0.054 for PP). Conclusion: Although cBP is related with UAE, this relationship is not superior to that of office peripheral BP.
- 1 October 2012
- Published by Elsevier in Medicina de Familia. SEMERGEN
- Vol. 38 (7) , 445-451
Cuándo y por qué iniciar el tratamiento farmacológico con doble terapia
- 1 October 2012
- Published by Elsevier in Medicina de Familia. SEMERGEN
- Vol. 38 (7) , 445-451
Cuándo y por qué iniciar el tratamiento farmacológico con doble terapia
- 1 July 2012
- Published by Elsevier in Hipertensión y Riesgo Vascular
- Vol. 29, 1-3
Inercia e incumplimiento a partes iguales
- 1 July 2012
- Published by Elsevier in Hipertensión y Riesgo Vascular
- Vol. 29, 1-3
Inercia e incumplimiento a partes iguales
- 1 June 2012
- Published by Elsevier in Revista Española de Cardiología (English Edition)
- Vol. 65 (6) , 544-550
¿Los pacientes con alto riesgo vascular toman correctamente la medicación antihipertensiva? Estudio Cumple-MEMS
- 1 June 2012
- Published by Elsevier in Revista Española de Cardiología (English Edition)
- Vol. 65 (6) , 544-550
¿Los pacientes con alto riesgo vascular toman correctamente la medicación antihipertensiva? Estudio Cumple-MEMS
- 1 June 2012
- Published by Elsevier in Revista Española de Cardiología (English Edition)
- Vol. 65 (6) , 544-550
Do Patients With High Vascular Risk Take Antihypertensive Medication Correctly? Cumple-MEMS Study
- 1 June 2012
- Published by Elsevier in Revista Española de Cardiología (English Edition)
- Vol. 65 (6) , 544-550
Do Patients With High Vascular Risk Take Antihypertensive Medication Correctly? Cumple-MEMS Study