David James Ward
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
David James Ward has a total of 111 co-authors. Here are the top co-authors by number of shared publications:
John Ellis
Cavendish Laboratory, University of Cambridge, Cambridge, UK
9 shared publications- Sam Morgan Lambrick
University of Cambridge, Rutherford Appleton Laboratory, United Kingdom
9 shared publications William Allison
Cavendish Laboratory, University of Cambridge, Cambridge, UK
9 shared publicationsAndrew P. Jardine
Cavendish Laboratory, University of Cambridge, 19 J J Thomson Avenue, Cambridge CB3 0HE, United Kingdom
8 shared publicationsJ. Ellis
8 shared publicationsW. Allison
The Cavendish Laboratory 1 , JJ Thomson Avenue, Cambridge CB3 0HE, United Kingdom
7 shared publications
Latest Publications
- Open Access
- 8 May 2026
- Published by Royal Society of Chemistry (RSC) in Digital Discovery
- Vol. 5 (6) , 2448-2457
AI-designed and AI-implemented control systems for bespoke scientific instrumentation: application to scanning microscopy
AI-assisted development route with cross-validation and sandbox verification.
- 8 May 2026
- Published by Royal Society of Chemistry (RSC) in Digital Discovery
- Vol. 5 (6) , 2448-2457
Open AccessAI-designed and AI-implemented control systems for bespoke scientific instrumentation: application to scanning microscopy
AI-assisted development route with cross-validation and sandbox verification.
- Open Access
- 16 March 2026
- Published by AIP Publishing in Applied Physics Letters
- Vol. 128 (11)
Diffraction contrast imaging of hydrogen passivation of silicon using helium microscopy
Hydrogen is a key element in the transition to a sustainable energy future, playing a vital role in clean fuel technologies, energy storage, and semiconductor engineering. Yet despite its significance, hydrogen remains challenging to image directly, due to its low mass and weak interaction with conventional microscopy probes. In this study, we present the first direct spatially resolved image of hydrogen-passivated surfaces across large (mm) lateral length scales, obtained using scanning helium microscopy (SHeM), an emerging and exclusively surface-sensitive imaging technology based on neutral and extremely low-energy helium atom beams. Using HF:NH4F-treated Si(111) surfaces as a model system, we directly observe a strong contrast between hydrogen-passivated and non-passivated surfaces as well as localized heterogeneities within the nominally homogeneous hydrogen layer. These spatial features are further probed using temperature programmed desorption and helium diffraction measurements, confirming surface diffraction from the hydrogen-stabilized surface lattice, rather than topography or absorption, as the origin of the observed contrast. Our work establishes SHeM as a powerful tool for light-element surface imaging, with broad implications for hydrogen-related behaviors in many fields.
- 16 March 2026
- Published by AIP Publishing in Applied Physics Letters
- Vol. 128 (11)
Open AccessDiffraction contrast imaging of hydrogen passivation of silicon using helium microscopy
Hydrogen is a key element in the transition to a sustainable energy future, playing a vital role in clean fuel technologies, energy storage, and semiconductor engineering. Yet despite its significance, hydrogen remains challenging to image directly, due to its low mass and weak interaction with conventional microscopy probes. In this study, we present the first direct spatially resolved image of hydrogen-passivated surfaces across large (mm) lateral length scales, obtained using scanning helium microscopy (SHeM), an emerging and exclusively surface-sensitive imaging technology based on neutral and extremely low-energy helium atom beams. Using HF:NH4F-treated Si(111) surfaces as a model system, we directly observe a strong contrast between hydrogen-passivated and non-passivated surfaces as well as localized heterogeneities within the nominally homogeneous hydrogen layer. These spatial features are further probed using temperature programmed desorption and helium diffraction measurements, confirming surface diffraction from the hydrogen-stabilized surface lattice, rather than topography or absorption, as the origin of the observed contrast. Our work establishes SHeM as a powerful tool for light-element surface imaging, with broad implications for hydrogen-related behaviors in many fields.
- Open Access
- 28 July 2025
- Published by AIP Publishing in Journal of Applied Physics
- Vol. 138 (4)
Heliometric stereo: A new frontier in surface profilometry
Accurate and reliable measurements of three-dimensional surface structures are important for a broad range of technological and research applications, including materials science, nanotechnology, and biomedical research. Scanning helium microscopy (SHeM) uses low-energy (∼64meV) neutral helium atoms as the imaging probe particles, providing a highly sensitive and delicate approach to measuring surface topography. To date, topographic SHeM measurements have been largely qualitative, but with the advent of the heliometric stereo method—a technique that combines multiple images to create a 3D representation of a surface—quantitative maps of surface topography may now be acquired with SHeM. Here, we present and discuss two different implementations of heliometric stereo on two separate instruments, a single-detector SHeM and a multiple-detector SHeM. Both implementations show good accuracy (5% and 10%, respectively) for recovering the shape of a surface. Additionally, we discuss where heliometric stereo is most applicable, identify contrast features that can limit its accuracy, and discuss how to mitigate these limitations with careful design and sample choices that be readily implemented on current instruments.
- 28 July 2025
- Published by AIP Publishing in Journal of Applied Physics
- Vol. 138 (4)
Open AccessHeliometric stereo: A new frontier in surface profilometry
Accurate and reliable measurements of three-dimensional surface structures are important for a broad range of technological and research applications, including materials science, nanotechnology, and biomedical research. Scanning helium microscopy (SHeM) uses low-energy (∼64meV) neutral helium atoms as the imaging probe particles, providing a highly sensitive and delicate approach to measuring surface topography. To date, topographic SHeM measurements have been largely qualitative, but with the advent of the heliometric stereo method—a technique that combines multiple images to create a 3D representation of a surface—quantitative maps of surface topography may now be acquired with SHeM. Here, we present and discuss two different implementations of heliometric stereo on two separate instruments, a single-detector SHeM and a multiple-detector SHeM. Both implementations show good accuracy (5% and 10%, respectively) for recovering the shape of a surface. Additionally, we discuss where heliometric stereo is most applicable, identify contrast features that can limit its accuracy, and discuss how to mitigate these limitations with careful design and sample choices that be readily implemented on current instruments.
- 4 March 2025
- Published by AIP Publishing in The Journal of Chemical Physics
- Vol. 162 (9)
Minimizing interference in low-pressure supersonic beam sources
Free-jet atomic, cluster, and molecular sources are typically used to produce beams of low-energy, neutral particles and find application in a wide array of technologies, from neutral atom microscopes to instruments for surface processing. We present a simple analytical theory that is applicable to many of these sources, when (i) the nozzle-skimmer distance is such that free molecular flow is achieved and (ii) there is negligible interference within the skimmer itself. The utility of the model is demonstrated by comparing experimental data with calculations performed using the theory. In particular, we show that skimmer interference is negligible compared to attenuation by “background” gas for room-temperature beams. Our treatment does not depend on any free parameters and obviates the complexity of previous theories. As a result, we are able to devise a number of design recommendations to minimize interference in sources operating with cryogenic-temperature beams.
- 4 March 2025
- Published by AIP Publishing in The Journal of Chemical Physics
- Vol. 162 (9)
Minimizing interference in low-pressure supersonic beam sources
Free-jet atomic, cluster, and molecular sources are typically used to produce beams of low-energy, neutral particles and find application in a wide array of technologies, from neutral atom microscopes to instruments for surface processing. We present a simple analytical theory that is applicable to many of these sources, when (i) the nozzle-skimmer distance is such that free molecular flow is achieved and (ii) there is negligible interference within the skimmer itself. The utility of the model is demonstrated by comparing experimental data with calculations performed using the theory. In particular, we show that skimmer interference is negligible compared to attenuation by “background” gas for room-temperature beams. Our treatment does not depend on any free parameters and obviates the complexity of previous theories. As a result, we are able to devise a number of design recommendations to minimize interference in sources operating with cryogenic-temperature beams.
- Open Access
A multi-detector neutral helium atom microscope
- Open Access
- 1 January 2025
- Published by ScienceOpen
- p. e024
Imaging with Atom Beams, Hard and Soft, 2D and 3D Materials
Recent advances in atom beam microscopy are presented with a focus on a new platform developed in Cambridge, now under commercial development. The new platform has enabled significant improvements in capability which are demonstrated using several applied samples, including bacteria and bacteria biofilms which are now accessible due to improvements in resolution measured with no surface treatment. And 2D materials where diffraction from the surface is used to enhance contrast and demonstrate a particularly interesting contrast mechanism. Beams of noble gasses, have been used for surface science for many years due to their surface sensitivity while causing no damage, but application to real space imaging through spatial resolving power is more recent, with the first reflection mode images reported in 2011 in Cambridge UK and Newcastle AUS. Rapid development has occurred since then in all major components of the apparatus, and here the improvements in creating beams efficiently, sample environment, scattering geometry and detector efficiency are discussed. The capabilities have enabled significant growth in the application of the technique, including chemical and diffraction enhanced contrast, depth profiling and real time 3D surface reconstruction. SHeM has been shown to reveal topographical structure completely non-invasively i.e. with no addition of a surface coating or contrast agents, which has significant applications in studying delicate samples. In the current work there is a focus on two applied sample groups, the first is 2D materials, particularly MOS2 where we demonstrate a capability to selectively image surface regains that are in the same phase, and thus when a phase change occurs.
- 1 January 2025
- Published by ScienceOpen
- p. e024
Open AccessImaging with Atom Beams, Hard and Soft, 2D and 3D Materials
Recent advances in atom beam microscopy are presented with a focus on a new platform developed in Cambridge, now under commercial development. The new platform has enabled significant improvements in capability which are demonstrated using several applied samples, including bacteria and bacteria biofilms which are now accessible due to improvements in resolution measured with no surface treatment. And 2D materials where diffraction from the surface is used to enhance contrast and demonstrate a particularly interesting contrast mechanism. Beams of noble gasses, have been used for surface science for many years due to their surface sensitivity while causing no damage, but application to real space imaging through spatial resolving power is more recent, with the first reflection mode images reported in 2011 in Cambridge UK and Newcastle AUS. Rapid development has occurred since then in all major components of the apparatus, and here the improvements in creating beams efficiently, sample environment, scattering geometry and detector efficiency are discussed. The capabilities have enabled significant growth in the application of the technique, including chemical and diffraction enhanced contrast, depth profiling and real time 3D surface reconstruction. SHeM has been shown to reveal topographical structure completely non-invasively i.e. with no addition of a surface coating or contrast agents, which has significant applications in studying delicate samples. In the current work there is a focus on two applied sample groups, the first is 2D materials, particularly MOS2 where we demonstrate a capability to selectively image surface regains that are in the same phase, and thus when a phase change occurs.
- Open Access
- 13 May 2024
- Published by AIP Publishing in Applied Physics Letters
- Vol. 124 (20)
3D surface profilometry using neutral helium atoms
Three-dimensional mapping of surface structures is important in a wide range of biological, technological, healthcare, and research applications. Neutral helium atom beams have been established as a sensitive probe of topography and have already enabled structural information to be obtained from delicate samples where conventional probes would cause damage. Here, we empirically demonstrate, for the first time, a reconstruction of a complete surface profile using measurements from a modified scanning helium microscope using the heliometric stereo method and a single detector instrument geometry. Results for the surface profile of tetrahedral aluminum potassium sulfate crystals demonstrate that the areas of surfaces and facet orientations can be recovered to within 5% of the expected values.
- 13 May 2024
- Published by AIP Publishing in Applied Physics Letters
- Vol. 124 (20)
Open Access3D surface profilometry using neutral helium atoms
Three-dimensional mapping of surface structures is important in a wide range of biological, technological, healthcare, and research applications. Neutral helium atom beams have been established as a sensitive probe of topography and have already enabled structural information to be obtained from delicate samples where conventional probes would cause damage. Here, we empirically demonstrate, for the first time, a reconstruction of a complete surface profile using measurements from a modified scanning helium microscope using the heliometric stereo method and a single detector instrument geometry. Results for the surface profile of tetrahedral aluminum potassium sulfate crystals demonstrate that the areas of surfaces and facet orientations can be recovered to within 5% of the expected values.
- Open Access
- 30 January 2024
- Published by American Physical Society (APS) in Physical Review Letters
- Vol. 132 (5) , 056202
Experimental Characterization of Defect-Induced Phonon Lifetime Shortening
We present the first direct experimental measurement of defect-induced lifetime shortening of acoustic surface phonons. Defects are found to contribute a temperature-independent component to the linewidths of Rayleigh wave phonons on a Ni(111) surface. We also characterized the increase in phonon scattering with both surface defect density and phonon wave vector. A quantitative estimate of the scattering rate between phonon modes and surface line defects is extracted from the experimental data for the first time. Published by the American Physical Society 2024
- 30 January 2024
- Published by American Physical Society (APS) in Physical Review Letters
- Vol. 132 (5) , 056202
Open AccessExperimental Characterization of Defect-Induced Phonon Lifetime Shortening
We present the first direct experimental measurement of defect-induced lifetime shortening of acoustic surface phonons. Defects are found to contribute a temperature-independent component to the linewidths of Rayleigh wave phonons on a Ni(111) surface. We also characterized the increase in phonon scattering with both surface defect density and phonon wave vector. A quantitative estimate of the scattering rate between phonon modes and surface line defects is extracted from the experimental data for the first time. Published by the American Physical Society 2024
- Open Access
- 6 December 2023
- Published by American Physical Society (APS) in Physical Review Letters
- Vol. 131 (23) , 236202
2D Helium Atom Diffraction from a Microscopic Spot
A method for measuring helium atom diffraction with micron-scale spatial resolution is demonstrated in a scanning helium microscope (SHeM) and applied to study a micron-scale spot on the (100) plane of a lithium fluoride (LiF) crystal. The positions of the observed diffraction peaks provide an accurate measurement of the local lattice spacing, while a combination of close-coupled scattering calculations and Monte Carlo ray-tracing simulations reproduce the main variations in diffracted intensity. Subsequently, the diffraction results are used to enhance image contrast by measuring at different points in reciprocal space. The results open up the possibility for using helium microdiffraction to characterize the morphology of delicate or electron-sensitive materials on small scales. These include many fundamentally and technologically important samples which cannot be studied in conventional atom scattering instruments, such as small grain size exfoliated 2D materials, polycrystalline samples, and other surfaces that do not exhibit long-range order.
- 6 December 2023
- Published by American Physical Society (APS) in Physical Review Letters
- Vol. 131 (23) , 236202
Open Access2D Helium Atom Diffraction from a Microscopic Spot
A method for measuring helium atom diffraction with micron-scale spatial resolution is demonstrated in a scanning helium microscope (SHeM) and applied to study a micron-scale spot on the (100) plane of a lithium fluoride (LiF) crystal. The positions of the observed diffraction peaks provide an accurate measurement of the local lattice spacing, while a combination of close-coupled scattering calculations and Monte Carlo ray-tracing simulations reproduce the main variations in diffracted intensity. Subsequently, the diffraction results are used to enhance image contrast by measuring at different points in reciprocal space. The results open up the possibility for using helium microdiffraction to characterize the morphology of delicate or electron-sensitive materials on small scales. These include many fundamentally and technologically important samples which cannot be studied in conventional atom scattering instruments, such as small grain size exfoliated 2D materials, polycrystalline samples, and other surfaces that do not exhibit long-range order.
- Open Access
- 6 December 2023
- Published by Springer Nature in Research Square
On the application of components manufactured with stereolithographic 3D printing in high vacuum systems
We report on a method for using stereolithographic (SLA) additive manufacturing to rapidly and cheaply prototype components for use in high-vacuum environments. We demonstrate the primary vacuum contaminant from freshly printed SLA plastics is water with no evidence of polymers out-gassing from the material and thus the vacuum performance can be controlled with simple treatments which do not involve surface sealing. An unbaked vacuum system containing SLA printed parts achieved 1.9e-8 mbar base pressure whilst retaining structural integrity and manufacturing accuracy. Preliminary results indicate that our method can be extended to achieve ultrahigh-vacuum compatibility by baking at higher temperatures. We further report on the effect of atmospheric exposure to components and present evidence to suggest that re-wetting occurs exclusively in the component skin layer, by showing that the bulk mass changes of the material is irreversible on the timescale investigated (< 2 weeks).
- 6 December 2023
- Published by Springer Nature in Research Square
Open AccessOn the application of components manufactured with stereolithographic 3D printing in high vacuum systems
We report on a method for using stereolithographic (SLA) additive manufacturing to rapidly and cheaply prototype components for use in high-vacuum environments. We demonstrate the primary vacuum contaminant from freshly printed SLA plastics is water with no evidence of polymers out-gassing from the material and thus the vacuum performance can be controlled with simple treatments which do not involve surface sealing. An unbaked vacuum system containing SLA printed parts achieved 1.9e-8 mbar base pressure whilst retaining structural integrity and manufacturing accuracy. Preliminary results indicate that our method can be extended to achieve ultrahigh-vacuum compatibility by baking at higher temperatures. We further report on the effect of atmospheric exposure to components and present evidence to suggest that re-wetting occurs exclusively in the component skin layer, by showing that the bulk mass changes of the material is irreversible on the timescale investigated (< 2 weeks).