Marcelo Aparecido Chinelatto
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Marcelo Aparecido Chinelatto has a total of 61 co-authors. Here are the top co-authors by number of shared publications:
- Sebastião Vicente Canevarolo
Universidade Federal de São Carlos, Brasil
6 shared publications - Lidiane Cristina Costa
Department of Materials Engineering (DEMa), Graduate Program in Materials Science and Engineering Federal University of São Carlos (UFSCar) São Carlos São Paulo Brazil
5 shared publications - Lucas Henrique Staffa
Department of Materials Engineering Federal University of São Carlos (UFSCar) São Carlos São Paulo Brazil
4 shared publications - Dávila Moreira Lopes Silva
University of Sao Paulo: Universidade de Sao Paulo
3 shared publications - Guilherme Camargo Ferraz
Universidade Estadual Paulista (Unesp), Brasil
3 shared publications - Paulo Aléscio Canola
SCIEN - Large Animal Surgery Lab, Faculty of Agricultural and Veterinary Sciences, São Paulo State University (Unesp), Jaboticabal, São Paulo, Brazil.
3 shared publications
Latest Publications
- 13 October 2025
- Published by Springer Nature in The International Journal of Advanced Manufacturing Technology
- Vol. 141 (1-2) , 767-782
Design and extrusion evaluation of a modular additive manufacturing machine with a head assisted by a single screw
- 13 October 2025
- Published by Springer Nature in The International Journal of Advanced Manufacturing Technology
- Vol. 141 (1-2) , 767-782
Design and extrusion evaluation of a modular additive manufacturing machine with a head assisted by a single screw
- Open Access
- 22 July 2025
- Published by Springer Nature in Research Square
Design and extrusion evaluation of a modular 3D printing equipment with a printhead assisted by a single screw
This paper presents the design and extrusion evaluation of a modular 3D printing equipment with a head assisted by a single screw. The adaptive and alternative equipment configurations allow processing material in powder or micro-pellet form, and a distributive mixing capacity that enables the continuous generation of filaments and printed geometries. The design combines a miniaturized modular head - operated under starve-fed or flood-fed conditions - with a benchtop Cartesian platform. The miniaturized modular printhead was prepared to monitor the temperature profile and die pressure. The experimental equipment validation was driven by two approaches: the extrusion effectiveness evaluation and analysis of additive-manufactured beads. The extrusion process was investigated by analytically modeling the pressure profile and experimentally verifying the temperature distribution within the 3D printhead. Additionally, residence time and extrudate swelling were measured. To evaluate the additive extrusion process, bead paths were printed, and based on a parametric analysis of the deposition, V-shaped test specimens were produced and subjected to tensile testing. The main results from the equipment indicated that the temperature gradient (200°C dosing zone – 57°C feeding ramp) of the system is favorable for processing polypropylene. The extruded strands presented regular surfaces and homogeneous morphology. The evaluated residence time is consistent with the conventional extrusion process, and the swelling index is between 1.55 and 1.78. The tensile test specimens exhibited an ultimate tensile strength close to 27 MPa.
- 22 July 2025
- Published by Springer Nature in Research Square
Open AccessDesign and extrusion evaluation of a modular 3D printing equipment with a printhead assisted by a single screw
This paper presents the design and extrusion evaluation of a modular 3D printing equipment with a head assisted by a single screw. The adaptive and alternative equipment configurations allow processing material in powder or micro-pellet form, and a distributive mixing capacity that enables the continuous generation of filaments and printed geometries. The design combines a miniaturized modular head - operated under starve-fed or flood-fed conditions - with a benchtop Cartesian platform. The miniaturized modular printhead was prepared to monitor the temperature profile and die pressure. The experimental equipment validation was driven by two approaches: the extrusion effectiveness evaluation and analysis of additive-manufactured beads. The extrusion process was investigated by analytically modeling the pressure profile and experimentally verifying the temperature distribution within the 3D printhead. Additionally, residence time and extrudate swelling were measured. To evaluate the additive extrusion process, bead paths were printed, and based on a parametric analysis of the deposition, V-shaped test specimens were produced and subjected to tensile testing. The main results from the equipment indicated that the temperature gradient (200°C dosing zone – 57°C feeding ramp) of the system is favorable for processing polypropylene. The extruded strands presented regular surfaces and homogeneous morphology. The evaluated residence time is consistent with the conventional extrusion process, and the swelling index is between 1.55 and 1.78. The tensile test specimens exhibited an ultimate tensile strength close to 27 MPa.
- 14 August 2024
- Published by Springer Nature in The International Journal of Advanced Manufacturing Technology
- Vol. 134 (5-6) , 2217-2232
Evaluation of the effects of extrusion parameters on the swelling of extruded filament in an innovative 3D printer containing a vertical co-rotating twin-screw extrusion unit
- 14 August 2024
- Published by Springer Nature in The International Journal of Advanced Manufacturing Technology
- Vol. 134 (5-6) , 2217-2232
Evaluation of the effects of extrusion parameters on the swelling of extruded filament in an innovative 3D printer containing a vertical co-rotating twin-screw extrusion unit
- Open Access
- 14 August 2024
- Published by Elsevier in Polymer Testing
- Vol. 138
Identifying the location and micellization of PEG-b-PCL multiblock copolymers in PLA/PCL blends via AFM nanoscale IR spectroscopy
- 14 August 2024
- Published by Elsevier in Polymer Testing
- Vol. 138
Open AccessIdentifying the location and micellization of PEG-b-PCL multiblock copolymers in PLA/PCL blends via AFM nanoscale IR spectroscopy
- 21 December 2022
- Published by Wiley in Macromolecular Symposia
- Vol. 406 (1)
Oven‐Drying Microfibrillated Cellulose Covered with a Low Molecular Weight Copolymer for Dispersion in a Polymer Matrix
Hornification remains a great challenge to the large‐scale use of oven‐dried microfibrillated cellulose (MFC) in industrial processes due to the difficulty to redisperse the oven‐dried MFC, especially in non‐polar polymer matrices. Therefore, an MFC coverage treatment with a low molecular weight copolymer is proposed here as a method to overcome hornification. MFC‐copolymer is produced by mechanical stirring and then oven‐dried. A poly(lactic acid) (PLA)/poly(ε‐caprolactone) (PCL)/MFC‐copolymer blend is prepared by melt extrusion to assess the dispersiveness of the treated MFC into the polymer matrix. Fourier Transform Infrared (FTIR) results suggest that the copolymer terminal hydroxyls can interact with the reactive hydroxyls present on the MFC surface, decreasing MFC hydrophilicity. Scanning Electron Microscopy (SEM) confirms that the copolymer covers parts of the MFC surface, which enables the microfibrils' redispersion. The solvent‐free, eco‐friendly, and low‐cost MFC‐copolymer treatment facilitates MFC redispersion by melting extrusion process in a low polarity polymeric matrix.
- 21 December 2022
- Published by Wiley in Macromolecular Symposia
- Vol. 406 (1)
Oven‐Drying Microfibrillated Cellulose Covered with a Low Molecular Weight Copolymer for Dispersion in a Polymer Matrix
Hornification remains a great challenge to the large‐scale use of oven‐dried microfibrillated cellulose (MFC) in industrial processes due to the difficulty to redisperse the oven‐dried MFC, especially in non‐polar polymer matrices. Therefore, an MFC coverage treatment with a low molecular weight copolymer is proposed here as a method to overcome hornification. MFC‐copolymer is produced by mechanical stirring and then oven‐dried. A poly(lactic acid) (PLA)/poly(ε‐caprolactone) (PCL)/MFC‐copolymer blend is prepared by melt extrusion to assess the dispersiveness of the treated MFC into the polymer matrix. Fourier Transform Infrared (FTIR) results suggest that the copolymer terminal hydroxyls can interact with the reactive hydroxyls present on the MFC surface, decreasing MFC hydrophilicity. Scanning Electron Microscopy (SEM) confirms that the copolymer covers parts of the MFC surface, which enables the microfibrils' redispersion. The solvent‐free, eco‐friendly, and low‐cost MFC‐copolymer treatment facilitates MFC redispersion by melting extrusion process in a low polarity polymeric matrix.
- 21 December 2022
- Published by Wiley in Macromolecular Symposia
- Vol. 406 (1)
Mechanical Properties of PLA/PCL Blends Compatibilized with PEG‐b‐PCL Multiblock Copolymer
Among the various kinds of copolymers that can be used as compatibilizers in poly (lactic acid) (PLA) and poly(ε‐caprolactone) (PCL) blends, copolymers containing segments of ε‐caprolactone and ethylene glycol (PEG) are an interesting choice because they are also biodegradable and biocompatible. A multiblock copolymer containing PEG and PCL segments, synthesized via one‐step bulk polycondensation, is added into PLA/PCL blend (80/20 wt%) at 1 and 5 wt% from the molten state, using a twin‐screw extruder. The effect of the PEG‐b‐PCL copolymer on the mechanical properties of PLA/PCL blends is investigated by tensile and Izod impact tests. The mixing of PCL with PLA does not promote adequate matrix toughness due to the incompatibility between the phases. The addition of only 1 wt% of the multiblock copolymer little changes the mechanical behavior of the blend. Only the compatibilized PLA/PCL blend with 5 wt% of the multiblock copolymer exhibits a significant increase in strain at break and notches Izod impact resistance in comparison with uncompatibilized PLA/PCL blends or neat PLA. Therefore, the addition of the PEG‐b‐PCL multiblock copolymer results in a marked change in the mechanical behavior, from brittle to ductile at room temperature, and confirms its compatibilization potential for the PLA/PCL immiscible blends.
- 21 December 2022
- Published by Wiley in Macromolecular Symposia
- Vol. 406 (1)
Mechanical Properties of PLA/PCL Blends Compatibilized with PEG‐b‐PCL Multiblock Copolymer
Among the various kinds of copolymers that can be used as compatibilizers in poly (lactic acid) (PLA) and poly(ε‐caprolactone) (PCL) blends, copolymers containing segments of ε‐caprolactone and ethylene glycol (PEG) are an interesting choice because they are also biodegradable and biocompatible. A multiblock copolymer containing PEG and PCL segments, synthesized via one‐step bulk polycondensation, is added into PLA/PCL blend (80/20 wt%) at 1 and 5 wt% from the molten state, using a twin‐screw extruder. The effect of the PEG‐b‐PCL copolymer on the mechanical properties of PLA/PCL blends is investigated by tensile and Izod impact tests. The mixing of PCL with PLA does not promote adequate matrix toughness due to the incompatibility between the phases. The addition of only 1 wt% of the multiblock copolymer little changes the mechanical behavior of the blend. Only the compatibilized PLA/PCL blend with 5 wt% of the multiblock copolymer exhibits a significant increase in strain at break and notches Izod impact resistance in comparison with uncompatibilized PLA/PCL blends or neat PLA. Therefore, the addition of the PEG‐b‐PCL multiblock copolymer results in a marked change in the mechanical behavior, from brittle to ductile at room temperature, and confirms its compatibilization potential for the PLA/PCL immiscible blends.
- Open Access
Facial Expressions of Horses Using Weighted Multivariate Statistics for Assessment of Subtle Local Pain Induced by Polylactide-Based Polymers Implanted Subcutaneously
Facial-expression-based analysis has been widely applied as a pain coding system in horses. Herein, we aimed to identify pain in horses undergoing subcutaneously polylactide-based polymer implantation. The sham group was submitted only to surgical incision. The horses were filmed before and 24 and 48 h after implantation. Five statistical methods for evaluating their facial expressions (FEs) were tested. Primarily, three levels of scores (0, 1, and 2) were applied to the seven FEs (ear movements, eyebrow tension, orbicularis tension, dilated nostrils, eye opening, muzzle tension, and masticatory muscles tension). Subsequently, the scores of the seven FEs were added (SUM). Afterwards, principal component analysis (PCoA) was performed using the scores of the seven FEs obtained using the first method. Subsequently, weights were created for each FE, based on each variable’s contribution variability obtained from the PCoA (SUM.W). Lastly, we applied a general score (GFS) to the animal’s face (0 = without pain; 1 = moderate pain; 2 = severe pain). The mechanical nociceptive threshold (MNT) and cutaneous temperature (CT) values were collected at the same moments. The results show no intra- or intergroup differences, when evaluating each FE separately or in the GFS. In the intragroup comparison and 48 h after implantation, the control group showed higher values for SUM, PCoA, and SUM.W, although the horses implanted with polymers displayed more obvious alterations in the CT and MNT. Our findings show that the five statistical strategies used to analyze the faces of the horses were not able to detect low-grade inflammatory pain.
Open AccessFacial Expressions of Horses Using Weighted Multivariate Statistics for Assessment of Subtle Local Pain Induced by Polylactide-Based Polymers Implanted Subcutaneously
Facial-expression-based analysis has been widely applied as a pain coding system in horses. Herein, we aimed to identify pain in horses undergoing subcutaneously polylactide-based polymer implantation. The sham group was submitted only to surgical incision. The horses were filmed before and 24 and 48 h after implantation. Five statistical methods for evaluating their facial expressions (FEs) were tested. Primarily, three levels of scores (0, 1, and 2) were applied to the seven FEs (ear movements, eyebrow tension, orbicularis tension, dilated nostrils, eye opening, muzzle tension, and masticatory muscles tension). Subsequently, the scores of the seven FEs were added (SUM). Afterwards, principal component analysis (PCoA) was performed using the scores of the seven FEs obtained using the first method. Subsequently, weights were created for each FE, based on each variable’s contribution variability obtained from the PCoA (SUM.W). Lastly, we applied a general score (GFS) to the animal’s face (0 = without pain; 1 = moderate pain; 2 = severe pain). The mechanical nociceptive threshold (MNT) and cutaneous temperature (CT) values were collected at the same moments. The results show no intra- or intergroup differences, when evaluating each FE separately or in the GFS. In the intragroup comparison and 48 h after implantation, the control group showed higher values for SUM, PCoA, and SUM.W, although the horses implanted with polymers displayed more obvious alterations in the CT and MNT. Our findings show that the five statistical strategies used to analyze the faces of the horses were not able to detect low-grade inflammatory pain.
- 17 August 2022
- Published by Springer Nature in Journal of Polymer Research
- Vol. 29 (9) , 1-14
Effect of molecular structure of PEG/PCL multiblock copolymers on the morphology and interfacial properties of PLA/PCL blends
- 17 August 2022
- Published by Springer Nature in Journal of Polymer Research
- Vol. 29 (9) , 1-14
Effect of molecular structure of PEG/PCL multiblock copolymers on the morphology and interfacial properties of PLA/PCL blends
- Open Access
Long-Term Evaluation of Poly(lactic acid) (PLA) Implants in a Horse: An Experimental Pilot Study
In horses, there is an increasing interest in developing long-lasting drug formulations, with biopolymers as viable carrier alternatives in addition to their use as scaffolds, suture threads, screws, pins, and plates for orthopedic surgeries. This communication focuses on the prolonged biocompatibility and biodegradation of PLA, prepared by hot pressing at 180 °C. Six samples were implanted subcutaneously on the lateral surface of the neck of one horse. The polymers remained implanted for 24 to 57 weeks. Physical examination, plasma fibrinogen, and the mechanical nociceptive threshold (MNT) were performed. After 24, 28, 34, 38, and 57 weeks, the materials were removed for histochemical analysis using hematoxylin-eosin and scanning electron microscopy (SEM). There were no essential clinical changes. MNT decreased after the implantation procedure, returning to normal after 48 h. A foreign body response was observed by histopathologic evaluation up to 38 weeks. At 57 weeks, no polymer or fibrotic capsules were identified. SEM showed surface roughness suggesting a biodegradation process, with an increase in the median pore diameter. As in the histopathological evaluation, it was not possible to detect the polymer 57 weeks after implantation. PLA showed biocompatible degradation and these findings may contribute to future research in the biomedical area.
Open AccessLong-Term Evaluation of Poly(lactic acid) (PLA) Implants in a Horse: An Experimental Pilot Study
In horses, there is an increasing interest in developing long-lasting drug formulations, with biopolymers as viable carrier alternatives in addition to their use as scaffolds, suture threads, screws, pins, and plates for orthopedic surgeries. This communication focuses on the prolonged biocompatibility and biodegradation of PLA, prepared by hot pressing at 180 °C. Six samples were implanted subcutaneously on the lateral surface of the neck of one horse. The polymers remained implanted for 24 to 57 weeks. Physical examination, plasma fibrinogen, and the mechanical nociceptive threshold (MNT) were performed. After 24, 28, 34, 38, and 57 weeks, the materials were removed for histochemical analysis using hematoxylin-eosin and scanning electron microscopy (SEM). There were no essential clinical changes. MNT decreased after the implantation procedure, returning to normal after 48 h. A foreign body response was observed by histopathologic evaluation up to 38 weeks. At 57 weeks, no polymer or fibrotic capsules were identified. SEM showed surface roughness suggesting a biodegradation process, with an increase in the median pore diameter. As in the histopathological evaluation, it was not possible to detect the polymer 57 weeks after implantation. PLA showed biocompatible degradation and these findings may contribute to future research in the biomedical area.
- 16 December 2020
- Published by Wiley in Macromolecular Symposia
- Vol. 394 (1)
Synthesis of Poly(ether‐ester‐urethane) with a Controlled Molar Mass Based on Poly(ε‐caprolactone) and Poly(ethylene glycol) Segments
Poly(ether‐ester‐urethanes) (PEEUs) derived from poly(ε‐caprolactone) and poly(ethylene glycol) (PCL‐b‐PEG) have a high potential for use in biomedical applications or as compatibilizers of immiscible poly(acid lactic) and poly(ε‐caprolactone) (PLA/PCL) blends. This study focused on the synthesis of PEEUs with same molar mass by one‐step bulk polycondensation of PCL and PEG macrodiols and hexamethylene diisocyanate (HDI). The copolymers, distinguished by the size of hydrophilic PEG and hydrophobic PCL segments and symmetry of the blocks, are characterized by SEC, FTIR, H1‐NMR, TGA, DSC, and water absorption testing. FTIR and H1‐NMR results demonstrated the formation of a hydroxy‐terminated multiblock copolymer with urethane bonds. Additionally, the PEG:PCL compositions measured by H1‐NMR are close to the theoretical compositions. Molar mass distribution curves revealed that copolymers with molar mass around 45 000 Da are synthesized by varying extents of ratio, given by NCO/OH molar ratio, between 0.9 and 1.0 depending on the initial macrodiols molar masses. The block size ratio of hydrophilic and hydrophobic blocks is an important parameter in water absorption behavior, which can generate a water‐uptake of 50% or even 350% depending on the symmetry of the segments.
- 16 December 2020
- Published by Wiley in Macromolecular Symposia
- Vol. 394 (1)
Synthesis of Poly(ether‐ester‐urethane) with a Controlled Molar Mass Based on Poly(ε‐caprolactone) and Poly(ethylene glycol) Segments
Poly(ether‐ester‐urethanes) (PEEUs) derived from poly(ε‐caprolactone) and poly(ethylene glycol) (PCL‐b‐PEG) have a high potential for use in biomedical applications or as compatibilizers of immiscible poly(acid lactic) and poly(ε‐caprolactone) (PLA/PCL) blends. This study focused on the synthesis of PEEUs with same molar mass by one‐step bulk polycondensation of PCL and PEG macrodiols and hexamethylene diisocyanate (HDI). The copolymers, distinguished by the size of hydrophilic PEG and hydrophobic PCL segments and symmetry of the blocks, are characterized by SEC, FTIR, H1‐NMR, TGA, DSC, and water absorption testing. FTIR and H1‐NMR results demonstrated the formation of a hydroxy‐terminated multiblock copolymer with urethane bonds. Additionally, the PEG:PCL compositions measured by H1‐NMR are close to the theoretical compositions. Molar mass distribution curves revealed that copolymers with molar mass around 45 000 Da are synthesized by varying extents of ratio, given by NCO/OH molar ratio, between 0.9 and 1.0 depending on the initial macrodiols molar masses. The block size ratio of hydrophilic and hydrophobic blocks is an important parameter in water absorption behavior, which can generate a water‐uptake of 50% or even 350% depending on the symmetry of the segments.