TGT. Jessie Ge

T. Jessie Ge

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


T. Jessie Ge has a total of 53 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Efficient Augmented Intelligence Framework for Bladder Lesion Detection

    by Okyaz Eminaga, Timothy Jiyong Lee, Mark Laurie, T. Jessie Ge, Vinh La, Jin Long, Axel Semjonow, Martin Bogemann, Hubert Lau, Eugene Shkolyar, et al.

    PURPOSE: Development of intelligence systems for bladder lesion detection is cost intensive. An efficient strategy to develop such intelligence solutions is needed. MATERIALS AND METHODS: We used four deep learning models (ConvNeXt, PlexusNet, MobileNet, and SwinTransformer) covering a variety of model complexity and efficacy. We trained these models on a previously published educational cystoscopy atlas (n = 312 images) to estimate the ratio between normal and cancer scores and externally validated on cystoscopy videos from 68 cases, with region of interest (ROI) pathologically confirmed to be benign and cancerous bladder lesions (ie, ROI). The performance measurement included specificity and sensitivity at frame level, frame sequence (block) level, and ROI level for each case. RESULTS: Specificity was comparable between four models at frame (range, 30.0%-44.8%) and block levels (56%-67%). Although sensitivity at the frame level (range, 81.4%-88.1%) differed between the models, sensitivity at the block level (100%) and ROI level (100%) was comparable between these models. MobileNet and PlexusNet were computationally more efficient for real-time ROI detection than ConvNeXt and SwinTransformer. CONCLUSION: Educational cystoscopy atlas and efficient models facilitate the development of real-time intelligence system for bladder lesion detection.


  • Open Access

    Data from Microvesicle-Mediated Delivery of Minicircle DNA Results in Effective Gene-Directed Enzyme Prodrug Cancer Therapy

    by Masamitsu Kanada, Bryan D. Kim, Jonathan W. Hardy, John A. Ronald, Michael H. Bachmann, Matthew P. Bernard, Gloria I. Perez, Ahmed A. Zarea, T. Jessie Ge, Alicia Withrow, et al.

    An emerging approach for cancer treatment employs the use of extracellular vesicles, specifically exosomes and microvesicles, as delivery vehicles. We previously demonstrated that microvesicles can functionally deliver plasmid DNA to cells and showed that plasmid size and sequence, in part, determine the delivery efficiency. In this study, delivery vehicles comprised of microvesicles loaded with engineered minicircle (MC) DNA that encodes prodrug converting enzymes developed as a cancer therapy in mammary carcinoma models. We demonstrated that MCs can be loaded into shed microvesicles with greater efficiency than their parental plasmid counterparts and that microvesicle-mediated MC delivery led to significantly higher and more prolonged transgene expression in recipient cells than microvesicles loaded with the parental plasmid. Microvesicles loaded with MCs encoding a thymidine kinase (TK)/nitroreductase (NTR) fusion protein produced prolonged TK-NTR expression in mammary carcinoma cells. In vivo delivery of TK-NTR and administration of prodrugs led to the effective killing of both targeted cells and surrounding tumor cells via TK-NTR–mediated conversion of codelivered prodrugs into active cytotoxic agents. In vivo evaluation of the bystander effect in mouse models demonstrated that for effective therapy, at least 1% of tumor cells need to be delivered with TK-NTR–encoding MCs. These results suggest that MC delivery via microvesicles can mediate gene transfer to an extent that enables effective prodrug conversion and tumor cell death such that it comprises a promising approach to cancer therapy.

  • Open Access

    Supplementary Data from Microvesicle-Mediated Delivery of Minicircle DNA Results in Effective Gene-Directed Enzyme Prodrug Cancer Therapy

    by Masamitsu Kanada, Bryan D. Kim, Jonathan W. Hardy, John A. Ronald, Michael H. Bachmann, Matthew P. Bernard, Gloria I. Perez, Ahmed A. Zarea, T. Jessie Ge, Alicia Withrow, et al.

  • Open Access

    Data from Microvesicle-Mediated Delivery of Minicircle DNA Results in Effective Gene-Directed Enzyme Prodrug Cancer Therapy

    by Masamitsu Kanada, Bryan D. Kim, Jonathan W. Hardy, John A. Ronald, Michael H. Bachmann, Matthew P. Bernard, Gloria I. Perez, Ahmed A. Zarea, T. Jessie Ge, Alicia Withrow, et al.

    An emerging approach for cancer treatment employs the use of extracellular vesicles, specifically exosomes and microvesicles, as delivery vehicles. We previously demonstrated that microvesicles can functionally deliver plasmid DNA to cells and showed that plasmid size and sequence, in part, determine the delivery efficiency. In this study, delivery vehicles comprised of microvesicles loaded with engineered minicircle (MC) DNA that encodes prodrug converting enzymes developed as a cancer therapy in mammary carcinoma models. We demonstrated that MCs can be loaded into shed microvesicles with greater efficiency than their parental plasmid counterparts and that microvesicle-mediated MC delivery led to significantly higher and more prolonged transgene expression in recipient cells than microvesicles loaded with the parental plasmid. Microvesicles loaded with MCs encoding a thymidine kinase (TK)/nitroreductase (NTR) fusion protein produced prolonged TK-NTR expression in mammary carcinoma cells. In vivo delivery of TK-NTR and administration of prodrugs led to the effective killing of both targeted cells and surrounding tumor cells via TK-NTR–mediated conversion of codelivered prodrugs into active cytotoxic agents. In vivo evaluation of the bystander effect in mouse models demonstrated that for effective therapy, at least 1% of tumor cells need to be delivered with TK-NTR–encoding MCs. These results suggest that MC delivery via microvesicles can mediate gene transfer to an extent that enables effective prodrug conversion and tumor cell death such that it comprises a promising approach to cancer therapy.

  • Open Access

    Supplementary Data from Microvesicle-Mediated Delivery of Minicircle DNA Results in Effective Gene-Directed Enzyme Prodrug Cancer Therapy

    by Masamitsu Kanada, Bryan D. Kim, Jonathan W. Hardy, John A. Ronald, Michael H. Bachmann, Matthew P. Bernard, Gloria I. Perez, Ahmed A. Zarea, T. Jessie Ge, Alicia Withrow, et al.

  • Passive monitoring by smart toilets for precision health

    by T. Jessie Ge, Vasiliki Nataly Rahimzadeh, Kevin Mintz, Walter G. Park, Nicole Martinez-Martin, Joseph C. Liao, Seung-Min Park

    Smart toilets are a key tool for enabling precision health monitoring in the home, but such passive monitoring has ethical considerations.


  • Continuous health monitoring: An opportunity for precision health

    by Sanjiv S. Gambhir, T. Jessie Ge, Ophir Vermesh, Ryan Spitler, Garry E. Gold

    Continuous health monitoring and integrated diagnostics should enable society to better understand human health and combat disease before it strikes.


  • Microvesicle-Mediated Delivery of Minicircle DNA Results in Effective Gene-Directed Enzyme Prodrug Cancer Therapy

    by Masamitsu Kanada, Bryan D. Kim, Jonathan W. Hardy, John A. Ronald, Michael H. Bachmann, Matthew P. Bernard, Gloria I. Perez, Ahmed A. Zarea, T. Jessie Ge, Alicia Withrow, et al.

    An emerging approach for cancer treatment employs the use of extracellular vesicles, specifically exosomes and microvesicles, as delivery vehicles. We previously demonstrated that microvesicles can functionally deliver plasmid DNA to cells and showed that plasmid size and sequence, in part, determine the delivery efficiency. In this study, delivery vehicles comprised of microvesicles loaded with engineered minicircle (MC) DNA that encodes prodrug converting enzymes developed as a cancer therapy in mammary carcinoma models. We demonstrated that MCs can be loaded into shed microvesicles with greater efficiency than their parental plasmid counterparts and that microvesicle-mediated MC delivery led to significantly higher and more prolonged transgene expression in recipient cells than microvesicles loaded with the parental plasmid. Microvesicles loaded with MCs encoding a thymidine kinase (TK)/nitroreductase (NTR) fusion protein produced prolonged TK-NTR expression in mammary carcinoma cells. In vivo delivery of TK-NTR and administration of prodrugs led to the effective killing of both targeted cells and surrounding tumor cells via TK-NTR–mediated conversion of codelivered prodrugs into active cytotoxic agents. In vivo evaluation of the bystander effect in mouse models demonstrated that for effective therapy, at least 1% of tumor cells need to be delivered with TK-NTR–encoding MCs. These results suggest that MC delivery via microvesicles can mediate gene transfer to an extent that enables effective prodrug conversion and tumor cell death such that it comprises a promising approach to cancer therapy.


  • An intravascular magnetic wire for the high-throughput retrieval of circulating tumour cells in vivo

    by Ophir Vermesh, Amin Aalipour, T. Jessie Ge, Yamil Saenz, Yue Guo, Israt S. Alam, Seung-Min Park, Charlie N. Adelson, Yoshiaki Mitsutake, Jose Vilches-Moure, et al.

    The detection and analysis of rare blood biomarkers is necessary for early diagnosis of cancer and to facilitate the development of tailored therapies. However, current methods for the isolation of circulating tumour cells (CTCs) or nucleic acids present in a standard clinical sample of only 5–10 ml of blood provide inadequate yields for early cancer detection and comprehensive molecular profiling. Here, we report the development of a flexible magnetic wire that can retrieve rare biomarkers from the subject’s blood in vivo at a much higher yield. The wire is inserted and removed through a standard intravenous catheter and captures biomarkers that have been previously labelled with injected magnetic particles. In a proof-of-concept experiment in a live porcine model, we demonstrate the in vivo labelling and single-pass capture of viable model CTCs in less than 10 s. The wire achieves capture efficiencies that correspond to enrichments of 10–80 times the amount of CTCs in a 5-ml blood draw, and 500–5,000 times the enrichments achieved using the commercially available Gilupi CellCollector.


  • Top Cited Papers

    Toward achieving precision health

    by Sanjiv Sam Gambhir, T. Jessie Ge, Ophir Vermesh, Ryan Spitler

    Precision health can help to prevent disease occurrence, detect disease earlier, and advance human health through the use of integrated diagnostics.