Milos Kucera
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Milos Kucera has a total of 45 co-authors. Here are the top co-authors by number of shared publications:
- Martin Oliverius
Department of Surgery, University Hospital Kralovske Vinohrady, Prague, Czech Republic
5 shared publications Milos Adamec
Transplant Surgery Department, Institute for Clinical and Experimental Medicine, Prague, Czech Republic
3 shared publicationsJ. Hrbacek
Faculty of Education/Technical education and Information Science, Brno, Czech Republic
2 shared publicationsLibor Janousek
2 shared publicationsA Schellongowski
1 shared publicationA. Boura
Department of Microelectronics, Faculty of Electrical Engineering, Czech Technical University in Prague, Technická 2, CZ - 166 27 Prague 6, Czech Republic
1 shared publication
Latest Publications
- 1 December 2016
- Published by Elsevier in Transplantation Proceedings
- Vol. 48 (10) , 3312-3316
Bile Duct Anastomosis Supplied With Biodegradable Stent in Liver Transplantation: The Initial Experience
- 1 December 2016
- Published by Elsevier in Transplantation Proceedings
- Vol. 48 (10) , 3312-3316
Bile Duct Anastomosis Supplied With Biodegradable Stent in Liver Transplantation: The Initial Experience
- 1 July 2014
- Published by Elsevier in Transplantation Proceedings
- Vol. 46 (6) , 1996-1998
Pancreatic Islet Autotransplantation After Completion Pancreatectomy for Pancreatic Fistula After Hemipancreatoduodenectomy for Carcinoma
- 1 July 2014
- Published by Elsevier in Transplantation Proceedings
- Vol. 46 (6) , 1996-1998
Pancreatic Islet Autotransplantation After Completion Pancreatectomy for Pancreatic Fistula After Hemipancreatoduodenectomy for Carcinoma
- 1 October 2013
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 133-137
Teaching robot programming can be a new opportunity for technical subjects of study
For more than three years we have been researching the possibilities of robot programming teaching at elementary schools. The aim is to increase an interest in technical subjects of study at secondary schools and universities with a technical orientation. Research has revealed many interesting facts, on the basis of which the methodology and teaching was proposed and production of robotic system kits was developed and launched. The system allows continuous education from primary school to university including production of prototypes of automation and robotic systems. In fact, construction suitability and quality has already been tested in practice. It turns out that education has a significant positive influence on both the natural and mutual authority of student - student and student - teacher and pupil discipline, diligence, consistency and the ability to solve problems. Further, it also influences the area of occupational safety and active creative use of IT technologies.
- 1 October 2013
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 133-137
Teaching robot programming can be a new opportunity for technical subjects of study
For more than three years we have been researching the possibilities of robot programming teaching at elementary schools. The aim is to increase an interest in technical subjects of study at secondary schools and universities with a technical orientation. Research has revealed many interesting facts, on the basis of which the methodology and teaching was proposed and production of robotic system kits was developed and launched. The system allows continuous education from primary school to university including production of prototypes of automation and robotic systems. In fact, construction suitability and quality has already been tested in practice. It turns out that education has a significant positive influence on both the natural and mutual authority of student - student and student - teacher and pupil discipline, diligence, consistency and the ability to solve problems. Further, it also influences the area of occupational safety and active creative use of IT technologies.
- Open Access
- 1 November 2012
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 143-148
Dynamic study support with connected external systems
For a long time, people have been trying to find ways that would lead to more effective teaching. Simultaneously, study and teaching supports have been developing. Current information technology, electronics and microprocessor technology have brought completely new possibilities into creation of study supports. They also allowed a new way of study supports creation and their direct connection with external systems. It is basically about the transition from static to dynamic creation of study supports. Also, the possibility of direct connection of study supports with external systems enables all that was impossible up to now, such as creation of study supports for a target group and the ability to monitor and manage students' practical activities or responses to these practical activities and modify study supports according to students' results. This is the prerequisite for the creation of study supports with internal intelligence. This paper summarizes the results of a research which has been conducted at our department for several years.
- 1 November 2012
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 143-148
Open AccessDynamic study support with connected external systems
For a long time, people have been trying to find ways that would lead to more effective teaching. Simultaneously, study and teaching supports have been developing. Current information technology, electronics and microprocessor technology have brought completely new possibilities into creation of study supports. They also allowed a new way of study supports creation and their direct connection with external systems. It is basically about the transition from static to dynamic creation of study supports. Also, the possibility of direct connection of study supports with external systems enables all that was impossible up to now, such as creation of study supports for a target group and the ability to monitor and manage students' practical activities or responses to these practical activities and modify study supports according to students' results. This is the prerequisite for the creation of study supports with internal intelligence. This paper summarizes the results of a research which has been conducted at our department for several years.
- 1 January 2011
- Vol. 150 (1) , 60-7
[Long-term follow-up of the first 500 liver transplant recipients transplanted at the Institute for Clinical and Experimental Medicine in Prague].
Between April 1995 and November 2005, 500 liver transplantations were performed in 476 patients of age from 3, till 70, at the Transplantation center of the Institute of Clinical and Experimental Medicine (IKEM) in Prague. The most common indications for liver transplantation were alcoholic liver cirrhosis (23%), hepatitis C cirrhosis (17%), and cholestatic cirrhosis (PBC and PSC, 9% each). Mean MELD score of recipients at the transplantation was 15-18 for each year of transplantation. Ten-years patient survival was 79.1 +/- 2.2%, and graft survival 74.1 +/- 2.1% respectively. Best patient and graft survival was achieved among patients transplanted for autoimmune liver diseases, the worst in group of patients with alcoholic cirrhosis. Malignancies were the most common cause of death during the period of follow-up (17 patients). Patients were followed longitudinally at the Department of hepatogastroenterology IKEM according to prospective protocol included protocol biopsies. Hypertension (in 71% of recipients), and overweight or obesity (in 56.3%), were the most prevalent medical complications among long-term survivors. Diabetes was found in 28.6%, of which 14.7% was de-nove diabetes after transplantation. Renal insufficiency (S-creatinin > 150 micromol/l) was present in 61 of 348 (17.6%) survivors. Out of these, 16 needed chronic hemodialysis, and 12 underwent kidney transplantation subsequently. Protocol biopsy at 5 years after transplantation was evaluated in a sample of 102 unselected liver transplant recipients. Normal liver was found in 4% of recipients, minor non-specific changes in 36% of them. Disease recurrence was present in all of 16 recipients transplanted for HCV cirrhosis, in one third of them graft cirrhosis was already present. Disease recurrence was found in patients transplanted for autoimmune disease frequently, PBC in 40%, PSC in 25%, and autoimmune hepatitis in 60% of recipients. Graft steatosis greater than 33% was present in 13% of recipients. Liver transplantation is highly effective method of treatment of end stage liver disease. Despite frequent medical complications, and disease recurrence on histological examination almost 80% of recipients transplanted in the liver transplantation program in IKEM survived more than 10 years after procedure. The survival achieved was far above that of the European liver transplant registry.
- 1 January 2011
- Vol. 150 (1) , 60-7
[Long-term follow-up of the first 500 liver transplant recipients transplanted at the Institute for Clinical and Experimental Medicine in Prague].
Between April 1995 and November 2005, 500 liver transplantations were performed in 476 patients of age from 3, till 70, at the Transplantation center of the Institute of Clinical and Experimental Medicine (IKEM) in Prague. The most common indications for liver transplantation were alcoholic liver cirrhosis (23%), hepatitis C cirrhosis (17%), and cholestatic cirrhosis (PBC and PSC, 9% each). Mean MELD score of recipients at the transplantation was 15-18 for each year of transplantation. Ten-years patient survival was 79.1 +/- 2.2%, and graft survival 74.1 +/- 2.1% respectively. Best patient and graft survival was achieved among patients transplanted for autoimmune liver diseases, the worst in group of patients with alcoholic cirrhosis. Malignancies were the most common cause of death during the period of follow-up (17 patients). Patients were followed longitudinally at the Department of hepatogastroenterology IKEM according to prospective protocol included protocol biopsies. Hypertension (in 71% of recipients), and overweight or obesity (in 56.3%), were the most prevalent medical complications among long-term survivors. Diabetes was found in 28.6%, of which 14.7% was de-nove diabetes after transplantation. Renal insufficiency (S-creatinin > 150 micromol/l) was present in 61 of 348 (17.6%) survivors. Out of these, 16 needed chronic hemodialysis, and 12 underwent kidney transplantation subsequently. Protocol biopsy at 5 years after transplantation was evaluated in a sample of 102 unselected liver transplant recipients. Normal liver was found in 4% of recipients, minor non-specific changes in 36% of them. Disease recurrence was present in all of 16 recipients transplanted for HCV cirrhosis, in one third of them graft cirrhosis was already present. Disease recurrence was found in patients transplanted for autoimmune disease frequently, PBC in 40%, PSC in 25%, and autoimmune hepatitis in 60% of recipients. Graft steatosis greater than 33% was present in 13% of recipients. Liver transplantation is highly effective method of treatment of end stage liver disease. Despite frequent medical complications, and disease recurrence on histological examination almost 80% of recipients transplanted in the liver transplantation program in IKEM survived more than 10 years after procedure. The survival achieved was far above that of the European liver transplant registry.
- 1 January 2011
- Vol. 150 (1) , 72-4
[Liver transplantation in patients with portal vein thrombosis].
Portal vein thrombosis has (PVT) long been an absolute contraindication to liver transplantation. In patients scheduled for liver transplantation, portal vein thrombosis occurs in 4-15%. The authors retrospectively collected data on 740 patients who underwent an initial orthotopic liver transplant at the authors' institution between 1996 and 2009. Mean follow-up was from 1 day to 6 years. There were 437 male patients and 303 female patients. We have performed this procedure in 57 recipients with PVT; this constitutes 7.7% of the overall transplant population. There was a 10.5% incidence of liver graft dysfunction, 10.5% of hepatic artery thrombosis, 19.3% of acute rejection and 17.5% of biliary complications. The overall incidence of relaparotomy for bleeding was 28% (16 patients). In-hospital mortality and late mortality were 15.8% and 31.6%, respectively. Volumes transfused were 17.1 (0-425) transfusion units of red blood cell, 27.1 (0-132) of fresh-frozen plasma and 2.6 (0-20) of platelets respectively. We confirm that PVT is not a contraindication to LTx at the present time.
- 1 January 2011
- Vol. 150 (1) , 72-4
[Liver transplantation in patients with portal vein thrombosis].
Portal vein thrombosis has (PVT) long been an absolute contraindication to liver transplantation. In patients scheduled for liver transplantation, portal vein thrombosis occurs in 4-15%. The authors retrospectively collected data on 740 patients who underwent an initial orthotopic liver transplant at the authors' institution between 1996 and 2009. Mean follow-up was from 1 day to 6 years. There were 437 male patients and 303 female patients. We have performed this procedure in 57 recipients with PVT; this constitutes 7.7% of the overall transplant population. There was a 10.5% incidence of liver graft dysfunction, 10.5% of hepatic artery thrombosis, 19.3% of acute rejection and 17.5% of biliary complications. The overall incidence of relaparotomy for bleeding was 28% (16 patients). In-hospital mortality and late mortality were 15.8% and 31.6%, respectively. Volumes transfused were 17.1 (0-425) transfusion units of red blood cell, 27.1 (0-132) of fresh-frozen plasma and 2.6 (0-20) of platelets respectively. We confirm that PVT is not a contraindication to LTx at the present time.
- 1 January 2011
- Published by International Scientific Information, Inc. in Annals of Transplantation
- Vol. 16 (3) , 121-125
Polypropylene mesh repair of incisional hernia after kidney transplantation: Single-center experience and review of the literature
Incisional hernia after kidney transplantation increases patient morbidity and impacts quality of life. Reports of hernia mesh repair after kidney transplantation are rare; thus, the benefit of mesh hernioplasty in transplanted patients is assumed. However, it is also assumed that transplant patients are susceptible to incisional and mesh infections. Between January 1, 2005 and December 31, 2010, we performed 1067 kidney transplantations. Twenty-eight patients developed incisional hernias (2.6%), and mesh repair was performed in 20 of them (8 women, 12 men; median age 59.5 years, range 43 to 68 years). We retrospectively studied this latter group. We also reviewed the literature regarding the results of this treatment. Postoperative mortality was zero, but postoperative wound bleeding led to surgical revision in 1 patient. Wound infection did not occur. During the follow-up period we observed 4 hernia recurrences (20%). In conclusion, our retrospective study and review of the literature confirmed the safety and low incidence (1.1% to 3.8%) of mesh hernia repair in chronic immunosuppressed patients after renal transplantation, which has a minimal risk of wound infection and no higher risk of hernia recurrence than in non-transplant patients.
- 1 January 2011
- Published by International Scientific Information, Inc. in Annals of Transplantation
- Vol. 16 (3) , 121-125
Polypropylene mesh repair of incisional hernia after kidney transplantation: Single-center experience and review of the literature
Incisional hernia after kidney transplantation increases patient morbidity and impacts quality of life. Reports of hernia mesh repair after kidney transplantation are rare; thus, the benefit of mesh hernioplasty in transplanted patients is assumed. However, it is also assumed that transplant patients are susceptible to incisional and mesh infections. Between January 1, 2005 and December 31, 2010, we performed 1067 kidney transplantations. Twenty-eight patients developed incisional hernias (2.6%), and mesh repair was performed in 20 of them (8 women, 12 men; median age 59.5 years, range 43 to 68 years). We retrospectively studied this latter group. We also reviewed the literature regarding the results of this treatment. Postoperative mortality was zero, but postoperative wound bleeding led to surgical revision in 1 patient. Wound infection did not occur. During the follow-up period we observed 4 hernia recurrences (20%). In conclusion, our retrospective study and review of the literature confirmed the safety and low incidence (1.1% to 3.8%) of mesh hernia repair in chronic immunosuppressed patients after renal transplantation, which has a minimal risk of wound infection and no higher risk of hernia recurrence than in non-transplant patients.
- 1 January 2009
- Published by Elsevier in IFAC Proceedings Volumes
- Vol. 42 (1) , 278-281
Laboratory task for measuring ECG and heart axis rotation
- 1 January 2009
- Published by Elsevier in IFAC Proceedings Volumes
- Vol. 42 (1) , 278-281
Laboratory task for measuring ECG and heart axis rotation
- 1 October 2008
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 175-178
Design and Fabrication of High-Temperature SOI Strain-Gauges
The following paper introduces the coventor ware design environment for SOI based piezoresistive sensor design. Fabrication process and characterization of designed sensors is also presented. The software package Coventor Ware has been used for design of mechanical and electrical characteristics of the structure. The tools enable design, modelling and successive modification of designed MEMS structures. The program enables: drawing of 2D layout and its editing, simulation of production process, generation of 3D model from 2D masks, generation of network by the method offinite elements, solution of mechanical, piezoresistive, thermal and further simulations. Simple passive elements (strain sensitive resistors - piezoresistors) were fabricated on SIMOX SOI substrates with sputtered AlCuSi metallization. Basic parameter extraction and their temperature dependence were performed.
- 1 October 2008
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 175-178
Design and Fabrication of High-Temperature SOI Strain-Gauges
The following paper introduces the coventor ware design environment for SOI based piezoresistive sensor design. Fabrication process and characterization of designed sensors is also presented. The software package Coventor Ware has been used for design of mechanical and electrical characteristics of the structure. The tools enable design, modelling and successive modification of designed MEMS structures. The program enables: drawing of 2D layout and its editing, simulation of production process, generation of 3D model from 2D masks, generation of network by the method offinite elements, solution of mechanical, piezoresistive, thermal and further simulations. Simple passive elements (strain sensitive resistors - piezoresistors) were fabricated on SIMOX SOI substrates with sputtered AlCuSi metallization. Basic parameter extraction and their temperature dependence were performed.
- 1 March 1998
- Published by Elsevier in British Journal of Anaesthesia
- Vol. 80 (3) , 313-317
Effects of hypothermia on thrombelastography in patients undergoing cardiopulmonary bypass
Thrombelastography (TEG) correlates with postoperative chest drain output in patients undergoing cardiopulmonary bypass (CPB). In vitro incubation with heparinase allows TEG monitoring during CPB, despite heparin anticoagulation. Hypothermia impairs coagulation, but these effects cannot be assessed by standard coagulation tests performed at 37 degrees C. The aim of this study was to assess the effects of hypothermia on TEG. Therefore, we have compared normothermic and temperature-adapted TEG in 30 patients undergoing CPB. Our data showed significantly impaired reaction time (r), kinetic time (k), and angle alpha (alpha) in temperature-adapted compared with normothermic TEG. Maximum amplitude (MA), reflecting absolute clot strength, was not affected at temperatures of 33-37 degrees C. These findings indicate a decrease in the speed of clot formation, but not absolute deterioration in clot quality. Furthermore, heparinase-modified TEG indicated that there were nine cases in which heparin effects persisted after heparin reversal with protamine, providing a rational guide to protamine therapy.
- 1 March 1998
- Published by Elsevier in British Journal of Anaesthesia
- Vol. 80 (3) , 313-317
Effects of hypothermia on thrombelastography in patients undergoing cardiopulmonary bypass
Thrombelastography (TEG) correlates with postoperative chest drain output in patients undergoing cardiopulmonary bypass (CPB). In vitro incubation with heparinase allows TEG monitoring during CPB, despite heparin anticoagulation. Hypothermia impairs coagulation, but these effects cannot be assessed by standard coagulation tests performed at 37 degrees C. The aim of this study was to assess the effects of hypothermia on TEG. Therefore, we have compared normothermic and temperature-adapted TEG in 30 patients undergoing CPB. Our data showed significantly impaired reaction time (r), kinetic time (k), and angle alpha (alpha) in temperature-adapted compared with normothermic TEG. Maximum amplitude (MA), reflecting absolute clot strength, was not affected at temperatures of 33-37 degrees C. These findings indicate a decrease in the speed of clot formation, but not absolute deterioration in clot quality. Furthermore, heparinase-modified TEG indicated that there were nine cases in which heparin effects persisted after heparin reversal with protamine, providing a rational guide to protamine therapy.