VPVivek Patel

Vivek Patel

*This is an algorithmically generated author record based on publicly available information.

Vivek Patel has a total of 33 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Federated and Distributed Learning for Secure and Explainable Cyber Defense

    by Vishal Barot, Abu Sarwar Zamani, Ankit Modi, Vivek Patel, Dipak Dabhi, Vivekkumar Prasad

    This chapter examines federated and distributed learning as a foundation for secure, explainable cyber defense. Centralized AI models create privacy risks, single points of failure, and opaque decisions that resist interpretation. The authors combine federated learning with explainable AI techniques, including SHAP, LIME, attention mechanisms, and federated feature importance aggregation, applied to intrusion detection, malware classification, and threat intelligence sharing. A key contribution is an empirical analysis of the privacy-explainability-accuracy trilemma, showing differential privacy degrades explanation fidelity, with an adaptive noise calibration mechanism proposed as a remedy. Adversarial robustness, including Byzantine fault tolerance and poisoning detection, is examined. Case studies from healthcare, industrial IoT, and enterprise security operations centers demonstrate applicability, with open challenges in non-IID data, communication efficiency, and compliance discussed.

  • Open Access

    Experimental Investigation and Multi-Objective Optimization of a Bubble Column Humidifier for HDH Desalination Applications

    by Vivek Patel, Vishal Barot, Pina Bhatt, Yogeshkumar Khimsuriya, Lav Kumar Kaushik, Pranav Mehta, Abd Elnaby Kabeel, David Bassir, Ghanshyam G. Tejani

  • Open Access

    Evaluation of Thermal Performance of Solar Air Heater Having Rotating Baffles and Thermal Energy Storage

    by Prerak Patel, Yogeshkumar Khimsuriya, Vivek Patel, Lav Kaushik

  • Thermohydraulic investigation of rotating baffled solar air heater

    by Yogeshkumar Khimsuriya, Vivek Patel, Piyush B Miyani, Sunita Deb, Lav Kumar Kaushik

    The thermohydraulic behavior of Solar Air Heater (SAH) having spiral-shaped baffles has been experimentally investigated in the present study. The experimental work was performed in India (Mehsana latitude and longitude: 23.5880° N, 72.3693° E) between 8th October 2022 and 15th January 2023. The rotating baffles are employed to achieve the favorable turbulent heat transfer mechanism within the system. The geometrical variables of relative roughness height (e/H) and relative roughness pitch (P/e) were evaluated between the range of 0.4–1.0 and 4–10, respectively, for the Reynolds numbers ( R e ) values of 4000 to 12000. Temperature difference (T o -T i ), pressure drop (∆P d ), thermohydraulic performance parameter (THPP) and useful heat gain (Q u ) were investigated for the range of e/H and P/e. The e/H turned out to be favorable by its gradual increment from 0.4 to 0.8, thereafter depicting the converse effect. e/H-1 and R e -12,000 resulted in the highest pressure drop of 150 Pa. The positive impact was noted f o r T o -T i for the increasing range of P/e. P/e-4 and R e of 12000 demonstrated the maximum pressure drop of 145 Pa. The e/H-0.8, P/e-8, and R e -12000 has achieved the highest value of useful heat gain, 398.52 W. The increment of 6.84 times and 21.81 times was achieved for both the Nusselt number ( N u ) and friction factor ( f ), respectively, compared to the smooth design of SAH. The value of THPP recorded as 2.68, which is higher than the reported value of 2.26 in the existing literature. In conclusion, the introduction of rotating spiral-shaped baffles presents a promising enhancement for SAH performance. However, further comprehensive field studies are necessary to fully exploit its potential.


  • Heat transfer enhancement in a solar air heater utilizing novel rotating spiral baffles

    by Yogeshkumar D. Khimsuriya, D. K. Patel, Vivek Patel, Ajay Singh Paikra, Lav Kumar Kaushik

    This study presents a substantial enhancement in the performance of solar air heaters (SAH) through the introduction of innovative rotating spiral-shaped baffles on the absorber plate, designed to optimize airflow within the duct and improve heat transfer. The results underscore the critical importance of fine-tuning geometric parameters, including relative roughness height (e/H: 0.4–1) and relative roughness pitch (P/e: 4–10), as well as the Reynolds number (Re: 4000–12 000), to achieve superior thermal efficiency. The optimization of these parameters is essential for maximizing performance while effectively managing flow resistance and turbulence. Experimental testing, conducted under a solar simulator (EN-12975-2 standard: irradiance uniformity of 10.47%, average solar irradiance of 955 W/m2), identified the configuration of P/e-8, e/H-0.8, and Re-12000 as the optimal combination. This setup yielded a maximum reduction of 17.29% in plate temperature (Tp), a 7.48% increase in outlet temperature (To), 63.33% augmentation in useful heat gain (Qu), and a 64.86% improvement in thermal efficiency (η) compared to a smooth duct. These findings provide key insights for advancing the design and operational efficiency of SAH systems. A field study to evaluate the practical applicability of this modification is recommended as the next step for further investigation.


  • Open Access

    Effectiveness of Cerebral Embolic Protection in Transcatheter Aortic Valve Replacement with High Aortic Valve Calcium Burden

    by A Gupta, O Koren, V Patel, T Nagasaki, D Patel, K Golwala, T Chakravarty, H Al-Jilaihawi, M Nakamura, R Makkar

    Background: The use of a cerebral embolic protection device (CEPD) during transcatheter aortic valve replacement (TAVR) has not been shown to be effective in preventing stroke in the PROTECTED-TAVR randomized controlled trial. However, whether CEPD may specifically benefit patients with high aortic valve calcium burden has not been studied. Purpose: This study aimed to determine the effectiveness of CEPD in preventing cerebrovascular events during TAVR in patients with high aortic valve calcium scores (AVCS) (>2000 AU in men and >1300 AU in women) detected on baseline computed tomography. Methods: We retrospectively analyzed 3505 patients who underwent transfemoral TAVR at a single center between 2016-2020 (Figure 1a). Baseline demographic, clinical, and procedural characteristics were stratified by CEPD use and AVCS (high vs. low). We performed Cox Proportional Hazards regression analysis to examine whether the use of CEPD in patients with high AVCS was associated with a lower rate of cerebrovascular events (stroke or transient ischemic attack) within 30 days (primary outcome) after adjusting for baseline characteristics. Results: We stratified our study cohort into four subgroups: low AVCS without CEPD (n=1163), low AVCS with CEPD (n=633), high AVCS without CEPD (n=1081), and high AVCS with CEPD (n=628). Patients for whom CEPD was used in high AVCS group had lower prevalence of peripheral arterial disease compared with no CEPD use. Otherwise, there were no significant differences in the baseline characteristics between patients with and without CEPD in either the low or high AVCS subgroups (Table). In adjusted analysis, CEPD use (HR 1.30 [95% CI, 0.64-2.65)] or high AVCS (HR 1.16 [95% CI, 0.64-2.02)] were not associated with a decreased rate of primary outcome (Figure 1b). Conclusion: This study indicates that CEPD use is not associated with lower cerebrovascular events after TAVR, even in patients with a high aortic valve calcium burden. Further research is needed to identify effective stroke prevention strategies for this patient population.Study design and Cox regression analysesBaseline Characteristics and Outcomes

  • Performance investigation of a modified single-basin solar distiller by augmenting thermoelectric cooler as an external condenser

    by Vivek Patel, Lav Kumar Kaushik, Yogeshkumar Devjibhai Khimsuriya, Pranav Mehta, Abd Elnaby Kabeel

    Harvesting freshwater from saline and seawater using solar energy has proven a significant impact in recent times. The present study aims to investigate the performance of the solar desalination system by incorporating glass reflectors, heat storage media, and a thermoelectric cooling system with a single-basin-type distiller. Accordingly, the objective of the study is to improve the performance of the solar distiller in terms of freshwater production and efficiency compared to a conventional setup. Moreover, the designed unit was tested under the environment of the Western part of India (Mehsana—23.5880° N, 72.3693° E) for 19 days in the months of May and June 2022. The maximum daily productivity observed during the day was 2.5 l at an average solar radiation of 1200 W/m2, which was 1.23 times higher than its conventional counterpart. Similarly, the energy efficiency showed a maximum improvement of 23.73%. At the middle of the day, i.e., maximum performance condition, the exergy efficiency was doubled with current modifications. Solar radiation and ambient temperature were found to be the most critical parameters that influence performance. Modifications also increase the % off sunshine hour productivity compared to sunshine hour from ~ 10 to 11% to ~ 20.8 to 24%, respectively. The cost of water distillation for the proposed solar still was found as 0.037 $/l/m2,s and the payback period was estimated as 2.27 years. The overall results indicate the positive influence of the modifications; hence, this type of setup is feasible for implementation on the field in harsh and coastal line areas. However, modified single-basin solar still needs extended field study to realize the full potential of the modifications.


  • Performance and Economic Analysis of Bubble Column Humidification and Thermoelectric Cooler Dehumidification Water Desalination System

    by Vivek Patel, Rajesh Patel, Sumit Kumar

    Although water is one of the key elements on the globe and accessible in a large amount, nearly one-half of the people of the globe are suffering from a shortage of freshwater that is increasing at a frightening rate most exclusively in growing nations where commercial water shortages prevail. So, in the regions with ample saline water and solar radiation where freshwater is usually limited, the humidification-dehumidification desalination systems have demonstrated inspiring outcomes. The experimental, theoretical and economical analysis of the BC humidifier, TEC based dehumidifier HDH system has been presented in this work. The effect of various operational parameters on HDH systems like Ta, Tw, H, do and ya has been studied. The daily experimental and theoretical productivity obtained during the analysis of the H-DH system was in the span of 7–13 L/day and 9.1–12.4 L/day respectively for dissimilar functional variables while the greatest experimental and theoretical productivity was reported 12.97 L/day and 12.4 L/day respectively for do=2 mm, ya=0.016 Kg/sec, Tw=60°C, Ta=27°C, and H=7 cm. Also, the experimental results present a fine confirmation with the results of the proposed mathematical model. From the economic analysis, it is found that the yearly price per liter and the payback period of the HDH system are Rs.5.1/L and 2.4 years respectively, which is a very promising value.