Rosa Dolz-Marco
Research Subjects
Rosa Dolz-Marco has a total of 334 co-authors. Here are the top co-authors by number of shared publications:
Roberto Gallego-Pinazo
Macula Unit, Oftalvist Clinic, Valencia, Spain
32 shared publications- Kenneth Bailey Freund
Vitreous Retina Macula Consultants of New York, New York, New York
31 shared publications - Roberto Gallego-Pinazo
Unidad de Mácula, Servicio de Oftalmología, Hospital Universitario y Politécnico La Fe, Valencia, España
25 shared publications Manuel Díaz-Llopis
Faculty of Medicine, University of Valencia, Spain
21 shared publicationsR. Gallego-Pinazo
Unidad de Mácula, Oftalvist, Valencia, Spain
9 shared publications- Maria Dolores Pinazo-Duran
Cellular and Molecular Ophthalmo-Biology Group, Department of Surgery, Faculty of Medicine and Dentistry, University of Valencia, Valencia, Spain
8 shared publications
Latest Publications
- 1 November 2026
- Published by Wolters Kluwer Health in Retina
- Vol. 46 (11) , 1898-1909
RETINAL PIGMENT EPITHELIUM DEFECTS, SEALED AND UNSEALED
Purpose: To describe two recurrent phenotypes of retinal pigment epithelium (RPE) defects, sealed and unsealed, which may occur in various diseases. Methods: Medical records and multimodal imaging of 17 patients (70.3 ± 9.3 years) with RPE defects, including RPE apertures, RPE detachment (retinal pigment epithelium detachment) devoid of RPE, and serous maculopathy with the absence of RPE, were retrospectively analyzed. Proposed pathogenic mechanisms are presented, revising current terminology. Results: Eyes with RPE apertures (12/17, 70.6%) and serous maculopathy with the absence of RPE (1/17, 5.9%) presented RPE defects connecting the subretinal and sub-RPE spaces with subretinal fluid (SRF) and intact outer retina. These features are consistent with patent RPE defects, termed “unsealed.” Retinal pigment epithelium detachment devoid of RPE defects developed in ¾ eyes (75%) over a serous PED without collapse. The lesions occurred beneath a degenerated outer retina that adheres to the RPE defect without SRF, supporting the term “sealed.” Conclusion: RPE defects beneath a disrupted photoreceptor layer may become “sealed” by reactive Müller cell gliosis, preventing the occurrence of SRF. Retinal pigment epithelium defects with intact photoreceptors remain “unsealed,” resulting in SRF accumulation. We propose “sealed” and “unsealed” as disease agnostic terms, which can be used for cases previously described as “RPE aperture,” “serous maculopathy with the absence of RPE,” and “RPED devoid of RPE.”
- 1 November 2026
- Published by Wolters Kluwer Health in Retina
- Vol. 46 (11) , 1898-1909
RETINAL PIGMENT EPITHELIUM DEFECTS, SEALED AND UNSEALED
Purpose: To describe two recurrent phenotypes of retinal pigment epithelium (RPE) defects, sealed and unsealed, which may occur in various diseases. Methods: Medical records and multimodal imaging of 17 patients (70.3 ± 9.3 years) with RPE defects, including RPE apertures, RPE detachment (retinal pigment epithelium detachment) devoid of RPE, and serous maculopathy with the absence of RPE, were retrospectively analyzed. Proposed pathogenic mechanisms are presented, revising current terminology. Results: Eyes with RPE apertures (12/17, 70.6%) and serous maculopathy with the absence of RPE (1/17, 5.9%) presented RPE defects connecting the subretinal and sub-RPE spaces with subretinal fluid (SRF) and intact outer retina. These features are consistent with patent RPE defects, termed “unsealed.” Retinal pigment epithelium detachment devoid of RPE defects developed in ¾ eyes (75%) over a serous PED without collapse. The lesions occurred beneath a degenerated outer retina that adheres to the RPE defect without SRF, supporting the term “sealed.” Conclusion: RPE defects beneath a disrupted photoreceptor layer may become “sealed” by reactive Müller cell gliosis, preventing the occurrence of SRF. Retinal pigment epithelium defects with intact photoreceptors remain “unsealed,” resulting in SRF accumulation. We propose “sealed” and “unsealed” as disease agnostic terms, which can be used for cases previously described as “RPE aperture,” “serous maculopathy with the absence of RPE,” and “RPED devoid of RPE.”
- Open Access
- 14 February 2026
- Published by Elsevier in Progress in Retinal and Eye Research
- Vol. 111, 101447
Structural photoreceptor evaluation in age-related macular degeneration. A comprehensive review of methods and clinical significance
- 14 February 2026
- Published by Elsevier in Progress in Retinal and Eye Research
- Vol. 111, 101447
Open AccessStructural photoreceptor evaluation in age-related macular degeneration. A comprehensive review of methods and clinical significance
- Open Access
- 28 March 2025
- Published by MDPI AG in Journal of Clinical Medicine
- Vol. 14 (7) , 2312
Vascular Perfusion Variability in Diabetic Retinopathy: A Sequential Interscan Optical Coherence Tomography Angiography Assessment
Background/Objectives: The aim of this study was to quantify the interscan variability of vascular perfusion in patients with diabetic retinopathy (DR) using sequential optical coherence tomography angiography (OCT-A) scans. Methods: Patients with low-grade DR (DRSS score 20) underwent five sequential OCT-A imaging sessions. Vessel perfusion density (VPD) values of the superficial capillary plexus (SCP), intermediate capillary plexus (ICP), deep capillary plexus (DCP), and choriocapillaris (CC) were computed using ImageJ Version 1.54 software via a binarization process. The binarized images were analyzed to compute VPD using vessel density plugins. Inter-session variability was assessed using the coefficient of variation (CV) and intraclass correlation coefficient (ICC). The results were compared with an age-matched group of healthy controls. Results: A total of 16 eyes from 16 patients with DR (6 females, 37.5%) and 16 eyes from healthy controls (6 females, 37.5%) were included. Mean VPD values for SCP, ICP, DCP, and CC in patients with DR were 23.64, 13.64, 15.31, and 36.57, respectively. Corresponding values for the healthy subjects were 37.65, 23.32, 22.05, and 49.00, respectively. No significant differences were found in VPD across consecutive scanning sessions (p > 0.05) in either group. However, significant differences in VPD were observed between patients who were healthy and patients with diabetes. Conclusions: Sequential OCT-A imaging demonstrated no significant inter-session variability in both healthy subjects and subjects with diabetes. The Spectralis OCT-A system showed high reliability for imaging both healthy and diseased conditions.
- 28 March 2025
- Published by MDPI AG in Journal of Clinical Medicine
- Vol. 14 (7) , 2312
Open AccessVascular Perfusion Variability in Diabetic Retinopathy: A Sequential Interscan Optical Coherence Tomography Angiography Assessment
Background/Objectives: The aim of this study was to quantify the interscan variability of vascular perfusion in patients with diabetic retinopathy (DR) using sequential optical coherence tomography angiography (OCT-A) scans. Methods: Patients with low-grade DR (DRSS score 20) underwent five sequential OCT-A imaging sessions. Vessel perfusion density (VPD) values of the superficial capillary plexus (SCP), intermediate capillary plexus (ICP), deep capillary plexus (DCP), and choriocapillaris (CC) were computed using ImageJ Version 1.54 software via a binarization process. The binarized images were analyzed to compute VPD using vessel density plugins. Inter-session variability was assessed using the coefficient of variation (CV) and intraclass correlation coefficient (ICC). The results were compared with an age-matched group of healthy controls. Results: A total of 16 eyes from 16 patients with DR (6 females, 37.5%) and 16 eyes from healthy controls (6 females, 37.5%) were included. Mean VPD values for SCP, ICP, DCP, and CC in patients with DR were 23.64, 13.64, 15.31, and 36.57, respectively. Corresponding values for the healthy subjects were 37.65, 23.32, 22.05, and 49.00, respectively. No significant differences were found in VPD across consecutive scanning sessions (p > 0.05) in either group. However, significant differences in VPD were observed between patients who were healthy and patients with diabetes. Conclusions: Sequential OCT-A imaging demonstrated no significant inter-session variability in both healthy subjects and subjects with diabetes. The Spectralis OCT-A system showed high reliability for imaging both healthy and diseased conditions.
- 25 November 2024
- Published by Springer Nature in Eye
- Vol. 39 (3) , 516-526
Non-exudative OCT findings in neovascular AMD
In this narrative review we describe the main optical coherence tomography biomarkers appearing in eyes with neovascular age-related macular degeneration (AMD) that do not directly correspond to exudation. We highlight those signs that may mimic exudation and therefore do not require active treatment, such as outer retinal tubulations, pseudocysts, lipid globules, or hyporeflective wedges. Other signs may indicate impending exudation such as hyperreflective foci or shallow irregular retinal pigment epithelium elevation, and therefore should be carefully monitored. We also review and summarize the different origins of subretinal hyperreflective material and describe the main signs of degeneration seen in eyes with AMD, such as outer retinal tubulation, thinning of the retinal layers, outer retinal atrophy, and choroidal changes.
- 25 November 2024
- Published by Springer Nature in Eye
- Vol. 39 (3) , 516-526
Non-exudative OCT findings in neovascular AMD
In this narrative review we describe the main optical coherence tomography biomarkers appearing in eyes with neovascular age-related macular degeneration (AMD) that do not directly correspond to exudation. We highlight those signs that may mimic exudation and therefore do not require active treatment, such as outer retinal tubulations, pseudocysts, lipid globules, or hyporeflective wedges. Other signs may indicate impending exudation such as hyperreflective foci or shallow irregular retinal pigment epithelium elevation, and therefore should be carefully monitored. We also review and summarize the different origins of subretinal hyperreflective material and describe the main signs of degeneration seen in eyes with AMD, such as outer retinal tubulation, thinning of the retinal layers, outer retinal atrophy, and choroidal changes.
- 12 January 2024
- Published by Wiley in Clinical & Experimental Ophthalmology
- Vol. 52 (2) , 207-219
Optical coherence tomography biomarkers in early and intermediate age‐related macular degeneration: A clinical guide
Advanced forms of age‐related macular degeneration (AMD), characterised by atrophic and neovascular changes, are a leading cause of vision loss in the elderly population worldwide. Prior to the development of advanced AMD, a myriad of risk factors from the early and intermediate stages of AMD have been published in the scientific literature over the last years. The ability to precisely recognise structural and anatomical changes in the ageing macula, altogether with the understanding of the individual risk implications of each one of them is key for an accurate and personalised diagnostic assessment. The present review aims to summarise updated evidence of the relative risk conferred by diverse macular signs, commonly seen on optical coherence tomography, in terms of progression to geographic atrophy or macular neovascularization. This information may also serve as a basis for tailored follow‐up monitoring visits.
- 12 January 2024
- Published by Wiley in Clinical & Experimental Ophthalmology
- Vol. 52 (2) , 207-219
Optical coherence tomography biomarkers in early and intermediate age‐related macular degeneration: A clinical guide
Advanced forms of age‐related macular degeneration (AMD), characterised by atrophic and neovascular changes, are a leading cause of vision loss in the elderly population worldwide. Prior to the development of advanced AMD, a myriad of risk factors from the early and intermediate stages of AMD have been published in the scientific literature over the last years. The ability to precisely recognise structural and anatomical changes in the ageing macula, altogether with the understanding of the individual risk implications of each one of them is key for an accurate and personalised diagnostic assessment. The present review aims to summarise updated evidence of the relative risk conferred by diverse macular signs, commonly seen on optical coherence tomography, in terms of progression to geographic atrophy or macular neovascularization. This information may also serve as a basis for tailored follow‐up monitoring visits.
- Open Access
- 2 January 2024
- Published by Association for Research in Vision and Ophthalmology (ARVO) in Translational Vision Science & Technology
- Vol. 13 (1) , 10
Astigmatism Influences Quantitative and Qualitative Analysis in Optical Coherence Tomography Angiography Imaging
Purpose: The purpose of this paper was to study the influence of astigmatism in optical coherence tomography angiography (OCTA) images in a quantitative and qualitative analysis. Methods: This was a prospective, cross-sectional study. We included 110 eyes of 110 patients: 20 eyes without astigmatism and 90 eyes with astigmatism ≥0.5 diopters (D). We performed a macula centered OCTA as a reference image. In patients without astigmatism, registered follow-up scans were performed after induction of −1 and −2 D astigmatism. In patients with astigmatism, we performed the follow-up scan after astigmatism correction. We used a set of cylindrical lenses attached to the camera head of the SPECTRALIS (Heidelberg Engineering, Heidelberg, Germany). A quantitative and qualitative analysis of the superficial vascular complex (SVC) and deep vascular complex (DVC) was performed. The main outcome measures were vessel density (VD), image quality, and the presence of artifacts. Results: Mean VD of the SVC was significantly higher in the reference images compared with the images after induction of −2 D. Differences with −1 D were nonsignificant. Higher degrees of astigmatisms had higher VD dropout (0.012–0.02 per diopter in SVC). Astigmatism axis showed no relevance in our cohort. Image quality assessed by two independent observers was graded as higher in images without astigmatism. Defocus and attenuation were more prevalent in images with astigmatism. Conclusions: Astigmatism of −2 D affects quantification of VD in OCTA images, mainly affecting the SVC, as well as the subjective quality assessment. Correction of this refractive error might be necessary for an accurate quantitative assessment of OCTA images. Translational Relevance: Correcting astigmatism of 2 D or greater appears to be necessary when analyzing OCTA images.
- 2 January 2024
- Published by Association for Research in Vision and Ophthalmology (ARVO) in Translational Vision Science & Technology
- Vol. 13 (1) , 10
Open AccessAstigmatism Influences Quantitative and Qualitative Analysis in Optical Coherence Tomography Angiography Imaging
Purpose: The purpose of this paper was to study the influence of astigmatism in optical coherence tomography angiography (OCTA) images in a quantitative and qualitative analysis. Methods: This was a prospective, cross-sectional study. We included 110 eyes of 110 patients: 20 eyes without astigmatism and 90 eyes with astigmatism ≥0.5 diopters (D). We performed a macula centered OCTA as a reference image. In patients without astigmatism, registered follow-up scans were performed after induction of −1 and −2 D astigmatism. In patients with astigmatism, we performed the follow-up scan after astigmatism correction. We used a set of cylindrical lenses attached to the camera head of the SPECTRALIS (Heidelberg Engineering, Heidelberg, Germany). A quantitative and qualitative analysis of the superficial vascular complex (SVC) and deep vascular complex (DVC) was performed. The main outcome measures were vessel density (VD), image quality, and the presence of artifacts. Results: Mean VD of the SVC was significantly higher in the reference images compared with the images after induction of −2 D. Differences with −1 D were nonsignificant. Higher degrees of astigmatisms had higher VD dropout (0.012–0.02 per diopter in SVC). Astigmatism axis showed no relevance in our cohort. Image quality assessed by two independent observers was graded as higher in images without astigmatism. Defocus and attenuation were more prevalent in images with astigmatism. Conclusions: Astigmatism of −2 D affects quantification of VD in OCTA images, mainly affecting the SVC, as well as the subjective quality assessment. Correction of this refractive error might be necessary for an accurate quantitative assessment of OCTA images. Translational Relevance: Correcting astigmatism of 2 D or greater appears to be necessary when analyzing OCTA images.
- 1 October 2023
- Published by Wolters Kluwer Health in Retina
- Vol. 43 (10) , 1653-1661
THE EFFECT OF INCREASING ACQUISITION SPEED ON OPTICAL COHERENCE TOMOGRAPHY ANGIOGRAPHY IMAGES
Purpose: To evaluate the effect of two different A-scan rates on qualitative and quantitative parameters on optical coherence tomography angiography images in a clinical setting. Methods: Subjects undergoing a comprehensive ophthalmic examination were scheduled for optical coherence tomography angiography imaging using a new SPECTRALIS device allowing for 85 and 125 kHz scan rate. Consecutive registered 20° × 20° optical coherence tomography angiography images using both speeds were acquired using the follow-up tool. The acquisition time and the quality values of each scan were extracted and analyzed. The image quality was also graded in pairs by two independent graders. Results: Two-hundred and one eyes of 128 consecutive patients (67 males, 52.3%) were included. Mean acquisition time significantly decreased from 56.92 ± 24.6 seconds on the 85 kHz images to 39.39 ± 15.5 seconds on the 125 kHz images (P < 0.001). The percentage change in acquisition time showed a mean decrease of 28.47%. Mean Q value significantly decreased from 32.97 ± 2.8 dB on the 85 kHz images to 31.43 ± 2.6 dB on the 125 kHz images (P < 0.001). Overall, 92.5% of images were graded as equal or better at 125 kHz A-scan rate. Conclusion: The use of optical coherence tomography angiography in daily clinical practice may require higher A-scan rates for an optimal workflow. Increased speed may also reduce image sensitivity and thus image quality could be compromised. In this study, 125 kHz scan rate using SPECTRALIS showed significant benefit with reduction on the acquisition time and no clinically significant differences on image quality analysis. Further studies evaluating qualitative and quantitative data in specific retinal conditions and using other devices are required to confirm these results.
- 1 October 2023
- Published by Wolters Kluwer Health in Retina
- Vol. 43 (10) , 1653-1661
THE EFFECT OF INCREASING ACQUISITION SPEED ON OPTICAL COHERENCE TOMOGRAPHY ANGIOGRAPHY IMAGES
Purpose: To evaluate the effect of two different A-scan rates on qualitative and quantitative parameters on optical coherence tomography angiography images in a clinical setting. Methods: Subjects undergoing a comprehensive ophthalmic examination were scheduled for optical coherence tomography angiography imaging using a new SPECTRALIS device allowing for 85 and 125 kHz scan rate. Consecutive registered 20° × 20° optical coherence tomography angiography images using both speeds were acquired using the follow-up tool. The acquisition time and the quality values of each scan were extracted and analyzed. The image quality was also graded in pairs by two independent graders. Results: Two-hundred and one eyes of 128 consecutive patients (67 males, 52.3%) were included. Mean acquisition time significantly decreased from 56.92 ± 24.6 seconds on the 85 kHz images to 39.39 ± 15.5 seconds on the 125 kHz images (P < 0.001). The percentage change in acquisition time showed a mean decrease of 28.47%. Mean Q value significantly decreased from 32.97 ± 2.8 dB on the 85 kHz images to 31.43 ± 2.6 dB on the 125 kHz images (P < 0.001). Overall, 92.5% of images were graded as equal or better at 125 kHz A-scan rate. Conclusion: The use of optical coherence tomography angiography in daily clinical practice may require higher A-scan rates for an optimal workflow. Increased speed may also reduce image sensitivity and thus image quality could be compromised. In this study, 125 kHz scan rate using SPECTRALIS showed significant benefit with reduction on the acquisition time and no clinically significant differences on image quality analysis. Further studies evaluating qualitative and quantitative data in specific retinal conditions and using other devices are required to confirm these results.
- 2 July 2023
- Published by SAGE Publications in European Journal of Ophthalmology
- Vol. 34 (3) , 624-630
Retinal neurodegeneration in age-related macular degeneration
Age-related macular degeneration (AMD) is a complex and multifactorial disease characterized by the damage of the unit comprised of the photoreceptors, retinal pigment epithelium (RPE), Bruch's membrane, and choriocapillaris. Although the outer retina appears to be mainly affected in this disorder, several evidences exhibit that also the inner retina may be impaired. In this review we will provide a description of the prominent histologic and imaging findings suggesting an inner retinal loss in these eyes. In details, structural optical coherence tomography (OCT) technology proved either the inner and outer retina is impacted by AMD and that these two impairments are associated. Therefore, the purpose of this review is to provide a description of the role of neurodegeneration in AMD in order to better understand the relationship between neuronal loss and the outer retinal damage in this disease.
- 2 July 2023
- Published by SAGE Publications in European Journal of Ophthalmology
- Vol. 34 (3) , 624-630
Retinal neurodegeneration in age-related macular degeneration
Age-related macular degeneration (AMD) is a complex and multifactorial disease characterized by the damage of the unit comprised of the photoreceptors, retinal pigment epithelium (RPE), Bruch's membrane, and choriocapillaris. Although the outer retina appears to be mainly affected in this disorder, several evidences exhibit that also the inner retina may be impaired. In this review we will provide a description of the prominent histologic and imaging findings suggesting an inner retinal loss in these eyes. In details, structural optical coherence tomography (OCT) technology proved either the inner and outer retina is impacted by AMD and that these two impairments are associated. Therefore, the purpose of this review is to provide a description of the role of neurodegeneration in AMD in order to better understand the relationship between neuronal loss and the outer retinal damage in this disease.
- 1 April 2023
- Published by Wolters Kluwer Health in Retina
- Vol. 43 (4) , 641-648
ADVANTAGES OF OPTICAL COHERENCE TOMOGRAPHY AS A HIGH DYNAMIC RANGE IMAGING MODALITY IN SUBRETINAL HYPERREFLECTIVE MATERIAL
Purpose: To describe the utility of high dynamic range optical coherence tomography imaging to study subretinal hyperreflective material (SHRM) in patients with age-related macular degeneration. Methods: Clinical information including visual acuity and optical coherence tomography images (Heidelberg Engineering GmbH, Heidelberg, Germany) of patients undergoing antiangiogenic treatment for neovascular age-related macular degeneration and showing SHRM at baseline were retrospectively reviewed. Contrast between strong signal structures (high dynamic range image) reclassifying SHRM as hyperreflective (HyperR), isoreflective, and hyporeflective was increased. The patients at baseline, 3, 6, and 12-months follow-up were evaluated. Results: Forty-four eyes were classified as 15 HyperR (34.1%), 21 as isoreflective (47.7%), and eight as hyporeflective (18.2%). During follow-up, hyporeflective SHRM disappeared in all cases, isoreflective SHRM faded in 16 cases (76.2%); HyperR SHRM remained in all cases. Hyporreflective SHRM showed a greater visual acuity improvement than HyperR SHRM group (P = 0.033). After 12-month follow-up, only the hyporeflective and isoreflective groups significantly reduced the presence of fluid in 37.5% (P = 0.250) and 46.62% (P = 0.006) of the patients, respectively; outer retinal layers were disrupted more frequently in the presence of HyperR SHRM (ellipsoid zone, P = 0.16; external limiting membrane, P = 0.007). Conclusion: Contrast-enhanced optical coherence tomography images enabled us to classify SHRM according to its reflectivity, showing groups with different disappearance rates, visual acuity improvement, and outer retinal layer disruption. This easy-to-access tool may be helpful as a prognostic factor in neovascular age-related macular degeneration cases.
- 1 April 2023
- Published by Wolters Kluwer Health in Retina
- Vol. 43 (4) , 641-648
ADVANTAGES OF OPTICAL COHERENCE TOMOGRAPHY AS A HIGH DYNAMIC RANGE IMAGING MODALITY IN SUBRETINAL HYPERREFLECTIVE MATERIAL
Purpose: To describe the utility of high dynamic range optical coherence tomography imaging to study subretinal hyperreflective material (SHRM) in patients with age-related macular degeneration. Methods: Clinical information including visual acuity and optical coherence tomography images (Heidelberg Engineering GmbH, Heidelberg, Germany) of patients undergoing antiangiogenic treatment for neovascular age-related macular degeneration and showing SHRM at baseline were retrospectively reviewed. Contrast between strong signal structures (high dynamic range image) reclassifying SHRM as hyperreflective (HyperR), isoreflective, and hyporeflective was increased. The patients at baseline, 3, 6, and 12-months follow-up were evaluated. Results: Forty-four eyes were classified as 15 HyperR (34.1%), 21 as isoreflective (47.7%), and eight as hyporeflective (18.2%). During follow-up, hyporeflective SHRM disappeared in all cases, isoreflective SHRM faded in 16 cases (76.2%); HyperR SHRM remained in all cases. Hyporreflective SHRM showed a greater visual acuity improvement than HyperR SHRM group (P = 0.033). After 12-month follow-up, only the hyporeflective and isoreflective groups significantly reduced the presence of fluid in 37.5% (P = 0.250) and 46.62% (P = 0.006) of the patients, respectively; outer retinal layers were disrupted more frequently in the presence of HyperR SHRM (ellipsoid zone, P = 0.16; external limiting membrane, P = 0.007). Conclusion: Contrast-enhanced optical coherence tomography images enabled us to classify SHRM according to its reflectivity, showing groups with different disappearance rates, visual acuity improvement, and outer retinal layer disruption. This easy-to-access tool may be helpful as a prognostic factor in neovascular age-related macular degeneration cases.
- Open Access
- 28 June 2022
- Published by Elsevier in American Journal of Ophthalmology Case Reports
- Vol. 27, 101641
Atypical acute fovealitis in COVID-19 context
- 28 June 2022
- Published by Elsevier in American Journal of Ophthalmology Case Reports
- Vol. 27, 101641
Open AccessAtypical acute fovealitis in COVID-19 context