Dario Turco
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Dario Turco has a total of 30 co-authors. Here are the top co-authors by number of shared publications:
- Stefano Severi
Department of Electrical, Electronic and Information Engineering ‘Guglielmo Marconi’, University of Bologna, Cesena, Italy
6 shared publications - Cristiana Corsi
Dept. of Electrical, Electronic and Information Engineering, University of Bologna, Cesena Campus, Italy
5 shared publications Cristiana Corsi
3 shared publications- Riccardo Magistroni
Surgical, Medical and Dental Department of Morphological Sciences, Section of Nephrology, University of Modena and Reggio Emilia, Modena, Italy
3 shared publications - Claudio Lamberti
University of Bologna
2 shared publications Renzo Mignani
2 shared publications
Latest Publications
- 1 November 2015
- Published by Elsevier in Academic Radiology
- Vol. 22 (11) , 1376-1384
Reliability of Total Renal Volume Computation in Polycystic Kidney Disease From Magnetic Resonance Imaging
- 1 November 2015
- Published by Elsevier in Academic Radiology
- Vol. 22 (11) , 1376-1384
Reliability of Total Renal Volume Computation in Polycystic Kidney Disease From Magnetic Resonance Imaging
- 1 August 2015
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- Vol. 2015 (1094687X) , 3081-3084
Geometry-independent assessment of renal volume in polycystic kidney disease from magnetic resonance imaging
Total renal volume (TRV) is an important quantitative indicator of the progression of autosomal dominant polycystic kidney disease (ADPKD). The Consortium for Radiologic Imaging Studies of Polycystic Kidney Disease proposes a method for TRV computation based on manual tracing and geometric modeling. We developed a fast and nearly-automated technique for kidney segmentation and automatically compute TRV. In this study we aim to compare TRV estimates derived from these two different approaches. The highly-automated technique for the analysis of MR images was tested on 30 ADPKD patients. TRV was computed from both axial and coronal acquisitions, and compared to measurements based on geometric modeling by linear regression and Bland Altman analysis. In addition, to assess reproducibility, intra-observer and inter-observer variabilities were computed. The results of this study provide the feasibility of using a nearly-automated approach for accurate and fast evaluation of TRV also in markedly enlarged ADPKD kidneys.
- 1 August 2015
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- Vol. 2015 (1094687X) , 3081-3084
Geometry-independent assessment of renal volume in polycystic kidney disease from magnetic resonance imaging
Total renal volume (TRV) is an important quantitative indicator of the progression of autosomal dominant polycystic kidney disease (ADPKD). The Consortium for Radiologic Imaging Studies of Polycystic Kidney Disease proposes a method for TRV computation based on manual tracing and geometric modeling. We developed a fast and nearly-automated technique for kidney segmentation and automatically compute TRV. In this study we aim to compare TRV estimates derived from these two different approaches. The highly-automated technique for the analysis of MR images was tested on 30 ADPKD patients. TRV was computed from both axial and coronal acquisitions, and compared to measurements based on geometric modeling by linear regression and Bland Altman analysis. In addition, to assess reproducibility, intra-observer and inter-observer variabilities were computed. The results of this study provide the feasibility of using a nearly-automated approach for accurate and fast evaluation of TRV also in markedly enlarged ADPKD kidneys.
- Open Access
- 11 February 2014
- Published by S. Karger AG in American Journal of Nephrology
- Vol. 39 (2) , 163-164
Comment on the Paper: ‘Novel Approach to Estimate Kidney and Cyst Volumes Using Mid-Slice Magnetic Resonance Images in Polycystic Kidney Disease'
We recently read and appreciated the paper ‘Novel approach to estimate kidney and cyst volumes using mid-slice magnetic resonance images in polycystic kidney disease' by Bae et al. [1]. The paper is very interesting and we recognize the intensive and very useful work the Consortium for Radiologic Imaging Studies of Polycystic Kidney Disease (CRISP) has conducted in the last years on this topic to develop methods to define a surrogate marker of the disease. Indeed, one of the most relevant results of CRISP was the evidence that magnetic resonance (MR) imaging is the best procedure for estimating changes in renal and cystic volume in autosomal dominant polycystic kidney disease over short follow-up periods.
- 11 February 2014
- Published by S. Karger AG in American Journal of Nephrology
- Vol. 39 (2) , 163-164
Open AccessComment on the Paper: ‘Novel Approach to Estimate Kidney and Cyst Volumes Using Mid-Slice Magnetic Resonance Images in Polycystic Kidney Disease'
We recently read and appreciated the paper ‘Novel approach to estimate kidney and cyst volumes using mid-slice magnetic resonance images in polycystic kidney disease' by Bae et al. [1]. The paper is very interesting and we recognize the intensive and very useful work the Consortium for Radiologic Imaging Studies of Polycystic Kidney Disease (CRISP) has conducted in the last years on this topic to develop methods to define a surrogate marker of the disease. Indeed, one of the most relevant results of CRISP was the evidence that magnetic resonance (MR) imaging is the best procedure for estimating changes in renal and cystic volume in autosomal dominant polycystic kidney disease over short follow-up periods.
- 30 September 2013
- Published by Elsevier in Heart Rhythm
- Vol. 10 (9) , 1360-1367
An exploratory study on coronary sinus lead tip three-dimensional trajectory changes in cardiac resynchronization therapy
- 30 September 2013
- Published by Elsevier in Heart Rhythm
- Vol. 10 (9) , 1360-1367
An exploratory study on coronary sinus lead tip three-dimensional trajectory changes in cardiac resynchronization therapy
- 1 September 2013
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 528-532
Assessment of kidney volumes in polycystic kidney disease from coronal and axial MR images
Total renal volume (TRV) and individual renal cysts are important quantitative indicators of the progression of autosomal dominant polycystic kidney disease (ADPKD). TRV has been assessed by manually tracing renal contours from CT or MR scans, often employing contrast media (CM). We developed a fast and nearly automated technique based on the analysis of MR axial images acquired without CM injection for TRV quantification. Twenty ADPKD patients underwent MRI. Automatic extraction of kidney contours was performed on each acquired slice; the segmentation procedure was based on region growing and on the application of morphological operators and curvature-based motion. The area inside each contour was calculated and TRV was derived. Volume measurements were compared between axial and coronal acquisitions. TRV estimated in patients from axial acquisition was 1931±1117ml (range: 428÷4622ml) and from coronal acquisition volumes resulted in 1943±1135ml (range: 393÷4604ml) (p>0.05). These automatic measurements were in excellent correlation (r=0.99, y=1.01×-13.9) with a small bias and narrow limits of agreement in both absolute (-12±93ml) and percentage (-0.2±4.6%) terms. This preliminary study showed TRV from axial and coronal MRI acquisitions can be assessed automatically and with comparable and accurate results without requiring the use of potentially nephrotoxic contrast medium.
- 1 September 2013
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 528-532
Assessment of kidney volumes in polycystic kidney disease from coronal and axial MR images
Total renal volume (TRV) and individual renal cysts are important quantitative indicators of the progression of autosomal dominant polycystic kidney disease (ADPKD). TRV has been assessed by manually tracing renal contours from CT or MR scans, often employing contrast media (CM). We developed a fast and nearly automated technique based on the analysis of MR axial images acquired without CM injection for TRV quantification. Twenty ADPKD patients underwent MRI. Automatic extraction of kidney contours was performed on each acquired slice; the segmentation procedure was based on region growing and on the application of morphological operators and curvature-based motion. The area inside each contour was calculated and TRV was derived. Volume measurements were compared between axial and coronal acquisitions. TRV estimated in patients from axial acquisition was 1931±1117ml (range: 428÷4622ml) and from coronal acquisition volumes resulted in 1943±1135ml (range: 393÷4604ml) (p>0.05). These automatic measurements were in excellent correlation (r=0.99, y=1.01×-13.9) with a small bias and narrow limits of agreement in both absolute (-12±93ml) and percentage (-0.2±4.6%) terms. This preliminary study showed TRV from axial and coronal MRI acquisitions can be assessed automatically and with comparable and accurate results without requiring the use of potentially nephrotoxic contrast medium.
- 1 January 2013
- Published by Springer Nature
- p. 53-61
Supervised Learning Modelization and Segmentation of Cardiac Scar in Delayed Enhanced MRI
- 1 January 2013
- Published by Springer Nature
- p. 53-61
Supervised Learning Modelization and Segmentation of Cardiac Scar in Delayed Enhanced MRI
- 29 June 2011
- Published by Springer Nature in Medical & Biological Engineering & Computing
- Vol. 49 (8) , 901-908
3D dynamic position assessment of the coronary sinus lead in cardiac resynchronization therapy
Although cardiac resynchronization therapy (CRT) is an effective treatment for chronic systolic heart failure with dyssynchrony, about one-third of patients do not respond favorably. The interaction between the pacing lead and the coronary sinus (CS) branches is of paramount importance for an effective resynchronization. Minor changes in lead position overtime could interfere with CRT mechanics, without affecting even biophysical parameters or ECG morphology. Although late post-implant CS lead dislodgement rate is consistent, lead movements have been little investigated and only with bi-dimensional methods. The aim of this study was (1) to develop a method for quantifying CS lead position in the 3D domain throughout the cardiac cycle and (2) to test it by comparing the CS lead position at implant and at follow-up, using chest fluoroscopy. Method performance, its accuracy and reproducibility were qualitatively and quantitatively assessed. Intra- and inter-observer percent discordance between trajectories were also computed. The accuracy of the procedure resulted in 0.3 ± 0.1 mm and its resolution was 0.5 mm. Intra- and inter-observer discordances were 2.2 ± 1.5 and 5.5 ± 3.6 mm, respectively. The proposed method for measuring the CS lead dynamic placement in 3D space seems accurate and reproducible. Investigating CS lead 3D dynamics could provide further insights into CRT mechanics.
- 29 June 2011
- Published by Springer Nature in Medical & Biological Engineering & Computing
- Vol. 49 (8) , 901-908
3D dynamic position assessment of the coronary sinus lead in cardiac resynchronization therapy
Although cardiac resynchronization therapy (CRT) is an effective treatment for chronic systolic heart failure with dyssynchrony, about one-third of patients do not respond favorably. The interaction between the pacing lead and the coronary sinus (CS) branches is of paramount importance for an effective resynchronization. Minor changes in lead position overtime could interfere with CRT mechanics, without affecting even biophysical parameters or ECG morphology. Although late post-implant CS lead dislodgement rate is consistent, lead movements have been little investigated and only with bi-dimensional methods. The aim of this study was (1) to develop a method for quantifying CS lead position in the 3D domain throughout the cardiac cycle and (2) to test it by comparing the CS lead position at implant and at follow-up, using chest fluoroscopy. Method performance, its accuracy and reproducibility were qualitatively and quantitatively assessed. Intra- and inter-observer percent discordance between trajectories were also computed. The accuracy of the procedure resulted in 0.3 ± 0.1 mm and its resolution was 0.5 mm. Intra- and inter-observer discordances were 2.2 ± 1.5 and 5.5 ± 3.6 mm, respectively. The proposed method for measuring the CS lead dynamic placement in 3D space seems accurate and reproducible. Investigating CS lead 3D dynamics could provide further insights into CRT mechanics.