Johnny Lam
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Johnny Lam has a total of 28 co-authors. Here are the top co-authors by number of shared publications:
- Kyung Eun Sung
Center for Biologics Evaluation and Research
4 shared publications - Antonios G. Mikos
Department of Bioengineering, Rice University, Houston, USA
1 shared publication - Brandon T. Smith
Houston, TX
1 shared publication - Brian J. Kwee
John A. Paulson School of Engineering and Applied Sciences, Harvard University, Cambridge, MA 02138, USA
1 shared publication Byungjun Lee
Qureator, Inc., San Diego, CA, USA
1 shared publicationE. Watson
Department of Bioengineering, Rice University, 6100 Main Street, Houston, TX 77005, USA
1 shared publication
Latest Publications
- Open Access
- 4 August 2025
- Published by American Chemical Society (ACS) in ACS Omega
- Vol. 10 (32) , 36466-36474
Microfluidic Nanobiosensor Detection of Botulinum Neurotoxin Serotype A
Botulinum neurotoxin (BoNT) poses a significant threat to public health as the most potent toxin known to humans. BoNT intoxication can lead to botulism, a life-threatening disease that may result from ingesting food contaminated with biologically active BoNT. The gold standard method for BoNT detection, the mouse bioassay, is time-consuming and raises ethical concerns regarding the use of laboratory animals. Therefore, there is a critical need for alternative methods that are rapid and require minimal training for field use. In this study, with potential in-field use in mind, we developed a microfluidic nanobiosensor that utilizes droplet-based passive pumping for easy operation and quantum dots (QDs) for sensitive detection. With droplet-based passive pumping, sensor preparation reagents and detection samples can be introduced via simple pipetting. Meanwhile, QDs offer a high quantum yield and excellent photostability, providing strong and reliable photoluminescent signals. The QDs were tethered to the surface of microfluidic channels via BoNT serotype-specific peptides, which can be cleaved due to the BoNT endopeptidase activity. In the presence of the active toxin, peptide cleavage released the QDs from the channels and the resulting reduced QD photoluminescence was measured as a detection signal. Using this biosensor, we detected the biologically active catalytic domain (light chain) of BoNT serotype A (LcA) at concentrations ranging from 1 ng/mL to 100 μg/mL, with a limit of detection (LoD) of 1 ng/mL (20 pM) in a small sample volume (1 pg LcA in 1 μL), within 2 h. This low-cost, user-friendly biosensor provides a rapid and effective method for detecting biologically active BoNT based on its endopeptidase activity without the use of laboratory animals, and it offers a scalable solution for potential BoNT screening in field or low-resource settings after further validation.
- 4 August 2025
- Published by American Chemical Society (ACS) in ACS Omega
- Vol. 10 (32) , 36466-36474
Open AccessMicrofluidic Nanobiosensor Detection of Botulinum Neurotoxin Serotype A
Botulinum neurotoxin (BoNT) poses a significant threat to public health as the most potent toxin known to humans. BoNT intoxication can lead to botulism, a life-threatening disease that may result from ingesting food contaminated with biologically active BoNT. The gold standard method for BoNT detection, the mouse bioassay, is time-consuming and raises ethical concerns regarding the use of laboratory animals. Therefore, there is a critical need for alternative methods that are rapid and require minimal training for field use. In this study, with potential in-field use in mind, we developed a microfluidic nanobiosensor that utilizes droplet-based passive pumping for easy operation and quantum dots (QDs) for sensitive detection. With droplet-based passive pumping, sensor preparation reagents and detection samples can be introduced via simple pipetting. Meanwhile, QDs offer a high quantum yield and excellent photostability, providing strong and reliable photoluminescent signals. The QDs were tethered to the surface of microfluidic channels via BoNT serotype-specific peptides, which can be cleaved due to the BoNT endopeptidase activity. In the presence of the active toxin, peptide cleavage released the QDs from the channels and the resulting reduced QD photoluminescence was measured as a detection signal. Using this biosensor, we detected the biologically active catalytic domain (light chain) of BoNT serotype A (LcA) at concentrations ranging from 1 ng/mL to 100 μg/mL, with a limit of detection (LoD) of 1 ng/mL (20 pM) in a small sample volume (1 pg LcA in 1 μL), within 2 h. This low-cost, user-friendly biosensor provides a rapid and effective method for detecting biologically active BoNT based on its endopeptidase activity without the use of laboratory animals, and it offers a scalable solution for potential BoNT screening in field or low-resource settings after further validation.
- Top Cited PapersOpen Access
- 17 January 2024
- Published by Royal Society of Chemistry (RSC) in Lab on a Chip
- Vol. 24 (5) , 1293-1306
Progress in developing microphysiological systems for biological product assessment
This review delves into microphysiological systems, miniature physiological environments used to evaluate biological products, reducing the need for animal experimentation. We consider their benefits as well as persistent challenges in material selection/fabrication and reproducibility.
- 17 January 2024
- Published by Royal Society of Chemistry (RSC) in Lab on a Chip
- Vol. 24 (5) , 1293-1306
Top Cited PapersOpen AccessProgress in developing microphysiological systems for biological product assessment
This review delves into microphysiological systems, miniature physiological environments used to evaluate biological products, reducing the need for animal experimentation. We consider their benefits as well as persistent challenges in material selection/fabrication and reproducibility.
- Open Access
- 27 September 2022
- Published by Elsevier in Biomaterials
- Vol. 290, 121826
A microphysiological system-based potency bioassay for the functional quality assessment of mesenchymal stromal cells targeting vasculogenesis
- 27 September 2022
- Published by Elsevier in Biomaterials
- Vol. 290, 121826
Open AccessA microphysiological system-based potency bioassay for the functional quality assessment of mesenchymal stromal cells targeting vasculogenesis
- Open Access
- 1 June 2019
- Published by American Association for the Advancement of Science (AAAS) in Science Advances
- Vol. 5 (6) , eaaw7396
Modular, tissue-specific, and biodegradable hydrogel cross-linkers for tissue engineering
Synthetic hydrogels are investigated extensively in tissue engineering for their tunable physicochemical properties but are bioinert and lack the tissue-specific cues to produce appropriate biological responses. To introduce tissue-specific biochemical cues to these hydrogels, we have developed a modular hydrogel cross-linker, poly(glycolic acid)–poly(ethylene glycol)–poly(glycolic acid)-di(but-2-yne-1,4-dithiol) (PdBT), that can be functionalized with small peptide-based cues and large macromolecular cues simply by mixing PdBT in water with the appropriate biomolecules at room temperature. Cartilage- and bone-specific PdBT macromers were generated by functionalization with a cartilage-associated hydrophobic N-cadherin peptide, a hydrophilic bone morphogenetic protein peptide, and a cartilage-derived glycosaminoglycan, chondroitin sulfate. These biofunctionalized PdBT macromers can spontaneously cross-link polymers such as poly(N-isopropylacrylamide) to produce rapidly cross-linking, highly swollen, cytocompatible, and hydrolytically degradable hydrogels suitable for mesenchymal stem cell encapsulation. These favorable properties, combined with PdBT’s modular design and ease of functionalization, establish strong potential for its usage in tissue engineering applications.
- 1 June 2019
- Published by American Association for the Advancement of Science (AAAS) in Science Advances
- Vol. 5 (6) , eaaw7396
Open AccessModular, tissue-specific, and biodegradable hydrogel cross-linkers for tissue engineering
Synthetic hydrogels are investigated extensively in tissue engineering for their tunable physicochemical properties but are bioinert and lack the tissue-specific cues to produce appropriate biological responses. To introduce tissue-specific biochemical cues to these hydrogels, we have developed a modular hydrogel cross-linker, poly(glycolic acid)–poly(ethylene glycol)–poly(glycolic acid)-di(but-2-yne-1,4-dithiol) (PdBT), that can be functionalized with small peptide-based cues and large macromolecular cues simply by mixing PdBT in water with the appropriate biomolecules at room temperature. Cartilage- and bone-specific PdBT macromers were generated by functionalization with a cartilage-associated hydrophobic N-cadherin peptide, a hydrophilic bone morphogenetic protein peptide, and a cartilage-derived glycosaminoglycan, chondroitin sulfate. These biofunctionalized PdBT macromers can spontaneously cross-link polymers such as poly(N-isopropylacrylamide) to produce rapidly cross-linking, highly swollen, cytocompatible, and hydrolytically degradable hydrogels suitable for mesenchymal stem cell encapsulation. These favorable properties, combined with PdBT’s modular design and ease of functionalization, establish strong potential for its usage in tissue engineering applications.
- Open Access
- 7 August 2018
- Published by Oxford University Press (OUP) in Stem Cells Translational Medicine
- Vol. 7 (9) , 664-675
Functional Profiling of Chondrogenically Induced Multipotent Stromal Cell Aggregates Reveals Transcriptomic and Emergent Morphological Phenotypes Predictive of Differentiation Capacity
Multipotent stromal cells (MSCs) are an attractive cell source for bone and cartilage tissue repair strategies. However, the functional heterogeneity of MSCs derived from different donors and manufacturing conditions has limited clinical translation, emphasizing the need for improved methods to assess MSC chondrogenic capacity. We used functionally relevant morphological profiling to dynamically monitor emergent morphological phenotypes of chondrogenically induced MSC aggregates to identify morphological features indicative of MSC chondrogenesis. Toward this goal, we characterized the morphology of chondrogenically stimulated MSC aggregates from eight different human cell-lines at multiple passages and demonstrated that MSC aggregates exhibited unique morphological dynamics that were both cell line- and passage-dependent. This variation in 3D morphology was shown to be informative of long-term MSC chondrogenesis based on multiple quantitative functional assays. We found that the specific morphological features of spheroid area, radius, minimum feret diameter, and minor axis length to be strongly correlated with MSC chondrogenic synthetic activity but not gene expression as early as day 4 in 3D culture. Our high-throughput, nondestructive approach could potentially serve as a tool to identify MSC lines with desired chondrogenic capacity toward improving manufacturing strategies for MSC-based cellular products for cartilage tissue repair. Stem Cells Translational Medicine 2018;1–12
- 7 August 2018
- Published by Oxford University Press (OUP) in Stem Cells Translational Medicine
- Vol. 7 (9) , 664-675
Open AccessFunctional Profiling of Chondrogenically Induced Multipotent Stromal Cell Aggregates Reveals Transcriptomic and Emergent Morphological Phenotypes Predictive of Differentiation Capacity
Multipotent stromal cells (MSCs) are an attractive cell source for bone and cartilage tissue repair strategies. However, the functional heterogeneity of MSCs derived from different donors and manufacturing conditions has limited clinical translation, emphasizing the need for improved methods to assess MSC chondrogenic capacity. We used functionally relevant morphological profiling to dynamically monitor emergent morphological phenotypes of chondrogenically induced MSC aggregates to identify morphological features indicative of MSC chondrogenesis. Toward this goal, we characterized the morphology of chondrogenically stimulated MSC aggregates from eight different human cell-lines at multiple passages and demonstrated that MSC aggregates exhibited unique morphological dynamics that were both cell line- and passage-dependent. This variation in 3D morphology was shown to be informative of long-term MSC chondrogenesis based on multiple quantitative functional assays. We found that the specific morphological features of spheroid area, radius, minimum feret diameter, and minor axis length to be strongly correlated with MSC chondrogenic synthetic activity but not gene expression as early as day 4 in 3D culture. Our high-throughput, nondestructive approach could potentially serve as a tool to identify MSC lines with desired chondrogenic capacity toward improving manufacturing strategies for MSC-based cellular products for cartilage tissue repair. Stem Cells Translational Medicine 2018;1–12