Ishan Saxena
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Ishan Saxena has a total of 9 co-authors. Here are the top co-authors by number of shared publications:
Anna Köhne
German Aerospace Center, Institute of Systems Engineering for Future Mobility
1 shared publicationAshok Mondal
Department of Electronics and Communication Engineering, MANIT, Bhopal, India
1 shared publication- Ashok Mondal
School of Electronics Engineering, Vellore Institute of Technology, Chennai, India
1 shared publication Bernd Westphal
German Aerospace Center, Institute of Systems Engineering for Future Mobility
1 shared publication- Dominik Grundt
Institute of Systems Engineering for Future Mobility, German Aerospace Center e.V (DLR), Escherweg 2, 26121 Oldenburg, Germany
1 shared publication - Eike Möhlmann
German Aerospace Center (DLR)
1 shared publication
Latest Publications
- Open Access
- 27 September 2022
- Published by Open Publishing Association in Electronic Proceedings in Theoretical Computer Science
- Vol. 371, 53-61
Towards Runtime Monitoring of Complex System Requirements for Autonomous Driving Functions
- 27 September 2022
- Published by Open Publishing Association in Electronic Proceedings in Theoretical Computer Science
- Vol. 371, 53-61
Open AccessTowards Runtime Monitoring of Complex System Requirements for Autonomous Driving Functions
- 13 February 2017
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Journal of Biomedical and Health Informatics
- Vol. 22 (3) , 775-784
A Noise Reduction Technique Based on Nonlinear Kernel Function for Heart Sound Analysis
The main difficulty encountered in interpretation of cardiac sound is interference of noise. The contaminated noise obscures the relevant information which are useful for recognition of heart diseases. The unwanted signals are produced mainly by lungs and surrounding environment. In this paper, a novel heart sound de-noising technique has been introduced based on a combined framework of wavelet packet transform (WPT) and singular value decomposition (SVD). The most informative node of wavelet tree is selected on the criteria of mutual information measurement. Next, the coefficient corresponding to the selected node is processed by SVD technique to suppress noisy component from heart sound signal. To justify the efficacy of the proposed technique, several experiments have been conducted with heart sound dataset, including normal and pathological cases at different signal to noise ratios. The significance of the method is validated by statistical analysis of the results. The biological information preserved in de-noised heart sound (HS) signal is evaluated by k-means clustering algorithm and Fit Factor calculation. The overall results show that proposed method is superior than the baseline methods.
- 13 February 2017
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Journal of Biomedical and Health Informatics
- Vol. 22 (3) , 775-784
A Noise Reduction Technique Based on Nonlinear Kernel Function for Heart Sound Analysis
The main difficulty encountered in interpretation of cardiac sound is interference of noise. The contaminated noise obscures the relevant information which are useful for recognition of heart diseases. The unwanted signals are produced mainly by lungs and surrounding environment. In this paper, a novel heart sound de-noising technique has been introduced based on a combined framework of wavelet packet transform (WPT) and singular value decomposition (SVD). The most informative node of wavelet tree is selected on the criteria of mutual information measurement. Next, the coefficient corresponding to the selected node is processed by SVD technique to suppress noisy component from heart sound signal. To justify the efficacy of the proposed technique, several experiments have been conducted with heart sound dataset, including normal and pathological cases at different signal to noise ratios. The significance of the method is validated by statistical analysis of the results. The biological information preserved in de-noised heart sound (HS) signal is evaluated by k-means clustering algorithm and Fit Factor calculation. The overall results show that proposed method is superior than the baseline methods.
- 1 March 2016
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-5
A robust voice activity detection technique based on combined framework of lacunarity and empirical mode decomposition
In this paper, we have proposed a new technique for voice activity detection (VAD) using lacunarity index combined with empirical mode decomposition (EMD) technique. In the preprocessing stage of the proposed framework, the noisy speech signal is decomposed into several intrinsic mode functions (IMFs) based on EMD technique. After that more informative IMFs are selected using spectral flatness measurement (SFM) approach. In the decision stage, the speech signal frames are identified by a threshold limit. The threshold value is calculated using statistical parameter of the lacunarity index of the reconstructed speech signal. The proposed technique gives superior results over existing techniques and is more effective at moderate noise levels.
- 1 March 2016
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-5
A robust voice activity detection technique based on combined framework of lacunarity and empirical mode decomposition
In this paper, we have proposed a new technique for voice activity detection (VAD) using lacunarity index combined with empirical mode decomposition (EMD) technique. In the preprocessing stage of the proposed framework, the noisy speech signal is decomposed into several intrinsic mode functions (IMFs) based on EMD technique. After that more informative IMFs are selected using spectral flatness measurement (SFM) approach. In the decision stage, the speech signal frames are identified by a threshold limit. The threshold value is calculated using statistical parameter of the lacunarity index of the reconstructed speech signal. The proposed technique gives superior results over existing techniques and is more effective at moderate noise levels.