DTDavid Johannes Thoen

David Johannes Thoen

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


David Johannes Thoen has a total of 355 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Enhanced electron-beam lithography to reduce the frequency scatter of 200–400 GHz superconducting microstrip resonators for on-chip filterbank spectrometers

    by L. G. G. Olde Scholtenhuis, D. J. Thoen, J. J. A. Baselmans, K. Karatsu, L. H. Marting, S. Vollebregt, A. Endo

    Integrated superconducting spectrometers provide the instantaneous bandwidth, sensitivity, and scalable architecture required for large-scale spectroscopic surveys in submillimeter-wave astronomy and cosmology. However, the accuracy with which the resonant frequencies of superconducting microstrip bandpass filters can be spaced has limited the spectral resolution of these spectrometers with continuous spectral coverage to F/ΔF < 500. The origin of this frequency scatter has been largely unknown. In this work, we demonstrate a fourfold improvement in the frequency spacing of superconducting microstrip resonators by optimizing electron-beam lithography. We find that reducing the electron-beam step size also reduces the random frequency scatter and that avoiding main-field stitching across filter patterns can eliminate a systematic frequency shift between groups of resonators, indicating the different origins of these two modes of frequency deviation. These findings demonstrate that nanometer-scale control of lithographic processes is imperative for the realization of next-generation integrated superconducting spectrometers with higher spectral resolution.

  • Open Access

    Design methodology of hybrid-type microwave kinetic inductance detectors toward ground-based mm-submm observations

    by T. Tanaka, K. Karatsu, H. Kutsuma, A. H. M. Coppens, A. Endo, M. Hattori, S. Honda, C. Otani, Y. Sueno, O. Tajima, et al.

    Context. Microwave kinetic inductance detectors (MKIDs) are superconducting detectors that have the potential to contribute to the construction of over 10 000 pixel cameras required for mm and submm astronomical observations over the next decade. One of the issues related to its application is two-level-system (TLS) noise that creates a 1/ f term in the power spectrum density (PSD) of the detectors. A hybrid-type MKID has been proposed for TLS noise suppression without affecting the MKID performance. In this paper, we present a systematic method to model a hybrid-type MKID for mitigating TLS noise while achieving high sensitivity. Aims. Previous studies have shown that TLS noise in MKIDs depends on the sampling frequency, internal power, device geometry, and temperature. The strength of the electrical field distribution along the resonator line also affects the TLS noise properties. Based on this knowledge, we constructed a noise model of a hybrid-type MKID. Methods. Using this model, we designed MKIDs for the cosmic microwave background radiation experiment, GroundBIRD. We evaluated the 1/ f noise properties and NET of the fabricated devices using the on-site measurements. Based on the NET measurements, we can confirm that the white noise of fabricated detectors is limited by atmospheric photon noise. From the 1/ f noise measurements, we also confirm that it is possible to reach an atmospheric photon noise limit down to a low sampling frequency (i.e., of a few Hz) at the typical observation conditions from Teide observatory. Results. We confirm the design methodology we propose for hybrid-type MKID works well in optimizing the TLS model to the hybrid-type MKID, as evidenced by performance verification measurements carried out in the laboratory and on site.

  • Open Access

    Advances in the Fabrication of On-Chip Superconducting Integral Field Units for CMB and Line-Intensity Astronomy

    by Leon G.G. Olde Scholtenhuis, Daniela Perez Capelo, Kenichi Karatsu, David J. Thoen, A. J. van der Linden, Shahab O. Dabironezare, Louis H. Marting, Jochem J.A. Baselmans, Sten Vollebregt, Akira Endo

    Studying the polarization and spectral distortion of the Cosmic Microwave Background (CMB) in tandem with intensity fluctuations of the Cosmic Infrared Background (CIB) allows us to verify our assumptions on cosmic inflation and investigate the dynamics and evolution of galaxy clusters in the last 10 billion years. Because of its broadband emission and being an all-sky extended source, observing the entire CMB in detail is a very time-consuming and expensive exercise. Fortunately, in the last few years, the on-chip superconducting spectrometer technology has moved out of the lab and into the telescope. With its compact size and background-limited sensitivity, this family of instruments is particularly well-suited for fast and large area observations in a relatively unexplored range of the electromagnetic spectrum. However, recent examples of this technology do not yet reach the requirements needed for large spectroscopic and polarimetric surveys of the CMB. We formulate several of these requirements and introduce novel on-chip components and fabrication techniques. We introduce a cross-over to enable distinguishing signal polarization, minimize signal loss by locally optimized lithography of a coplanar-waveguide (CPW), lower the spectral resolution of microstrip filters by deposition of a dielectric layer, and increase the yield of the spectrometer array by removing individual line shorts. These together have culminated in the successful fabrication of a fourteen-spaxel IFU.


  • Open Access

    AMKID: A large KID-based camera at the APEX telescope

    by N. Reyes, A. Weiss, S. J. C. Yates, A. M. Baryshev, I. Cámara-Mayorga, S. Dabironezare, A. Endo, L. Ferrari, A. Görlitz, G. Grutzeck, et al.

    Thermal emission at submillimeter wavelengths carries unique information for many astronomical applications, ranging from disks and planet formation around young stars to galaxy evolution studies at cosmological distances. Advancing the mapping speed to detect this faint emission in ground-based astronomy has been a technical challenge for decades. The APEX Microwave Kinetic Inductance Detector (AMKID) camera was designed to accomplish this task. The instrument is a wide field-of-view camera based on kinetic inductance detectors. It is installed on the 12-meter APEX telescope in Chile at 5100 meters above sea level. The instrument operates in dual color, covering the 350 and 850 GHz atmospheric windows simultaneously. It has a large field of view of 15.3′ × 15.3′ and an unprecedented number of pixels: 13 952 detectors in the high-frequency band and 3520 detectors in the low-frequency band. Here we present a complete description of the instrument design and construction, together with results from the successful low-frequency-array (LFA) commissioning campaign executed over the last year. The LFA performance is in good agreement with design parameters, with detector sensitivity of 2.2 mK s and diffraction-limited beam sizes of 17.0″. On-sky measurements demonstrate a sensitivity of 70–90 mJy s per detector under good atmospheric conditions (PWV below 1.0 mm). With this performance the LFA regularly achieves a mapping sensitivity of 25 mJy when mapping a square degree in one hour. AMKID on APEX with its dual-color observing capabilities, high sensitivity, large field of view, and high angular resolution promises to open new scientific opportunities with the APEX telescope.


  • Open Access

    Recombination of localized quasiparticles in disordered superconductors

    by Steven A. H. de Rooij, Remko Fermin, Kevin Kouwenhoven, Tonny Coppens, Vignesh Murugesan, David J. Thoen, Jan Aarts, Jochem J. A. Baselmans, Pieter J. de Visser

    Disordered superconductors offer new impedance regimes for quantum circuits, enable a pathway to protected qubits, and can improve superconducting detectors due to their high kinetic inductance and sheet resistance. The performance of these devices can be limited, however, by quasiparticles—the fundamental excitations of a superconductor. While experiments have shown that disorder affects the relaxation of quasiparticles drastically, the microscopic mechanisms are still not understood. We address this issue by measuring quasiparticle relaxation in a disordered β-Ta film, which we pattern as the inductor of a microwave resonator. We observe that quasiparticle recombination is governed by the phonon scattering time, which is faster than conventional recombination in ordered superconductors. We interpret the results as recombination of localized quasiparticles, induced by disorder, which first delocalize via phonon absorption. We analyze quasiparticle relaxation measurements on superconductors with different degrees of disorder and conclude that this phenomenon is inherent to disordered superconductors.


  • Lens Based Kinetic Inductance Detectors With Distributed Dual Polarized Absorbers for Far Infrared Space-Based Astronomy

    by Shahab Oddin Dabironezare, Giulia Conenna, Daan Roos, Dimitry Lamers, Daniela Perez Capelo, Hendrik M. Veen, David J. Thoen, Vishal Anvekar, Stephen J. C. Yates, Willem Jellema, et al.

    Future space-based far infrared astronomical observations require background limited detector sensitivities and scalable focal plane array solutions to realize their vast potential in observation speed. In this work, a focal plane array of lens absorber coupled kinetic inductance detectors (KIDs) is proposed to fill this role. The figures of merit and design guidelines for the proposed detector concept are derived by employing a previously developed electromagnetic spectral modeling technique. Two designs operating at central frequencies of 6.98 and 12 THz are studied. A prototype array of the former is fabricated, and its performance is experimentally determined and validated. Specifically, the optical coupling of the detectors to incoherent distributed sources (i.e., normalized throughput) is quantified experimentally with good agreement with the estimations provided by the model. The coupling of the lens absorber prototypes to an incident plane wave, i.e., aperture efficiency, is also indirectly validated experimentally matching the expected value of 54% averaged over two linear polarizations. The noise equivalent power of the KIDs is also measured with limiting value of $\text{8}\times \text{10}^{-\text{20}}$ $\mathrm{W/\sqrt{Hz}}$ at the bath and radiator temperatures of 130 mK and 2.7 K, respectively, under negligible optical loading.


  • Volume dependence of microwave-induced excess quasiparticles in superconducting resonators

    by Steven A.H. de Rooij, Jochem J.A. Baselmans, Juan Bueno, Vignesh Murugesan, David J. Thoen, Pieter J. de Visser


  • Demonstration of Ultrasensitive KIDs for Future THz Space Borne Polarimeters

    by Stephen J. C. Yates, Alejandro Pascual Laguna, Willem Jellema, Edgar Castillo-Dominguez, Lorenza Ferrari, Bram Lap, Vignesh Murugesan, Jose R. G. Silva, David Thoen, Ian Veenendaal, et al.

    We present measurements and simulations of the polarization purity of leaky lens-antenna coupled microwave Kinetic Inductance Detectors (KIDs) at 1.5 THz. From polarized phase and amplitude beam pattern measurements we find the integrated cross-polarization ratio to be at -21.5 dB for 1 f#$\lambda$ spatial sampling. The measurements agree well with the theoretical description which is based on a combination of in-transmission simulation of the antenna feed, and an in-reception analysis of the antenna-KID system. A neutral density filter limited the power per detector to around 500 fW, enabling these measurements to be taken on detectors that in a low background have a measured noise equivalent power of 5–7$\times 10^{-20}$ W$/\sqrt{\rm{Hz}}$. These combined measurements show that these detectors are excellent candidates for large scale and high-performance imaging polarimetric instruments.


  • Geometry dependence of two-level-system noise and loss in a-SiC:H parallel-plate capacitors for superconducting microwave resonators

    by K. Kouwenhoven, G.P.J. van Doorn, B.T. Buijtendorp, S.A.H. de Rooij, D. Lamers, D.J. Thoen, V. Murugesan, J.J.A. Baselmans, P.J. de Visser

    Parallel-plate capacitors (PPC) significantly reduce the size of superconducting microwave resonators, reducing the pixel pitch for arrays of single-photon energy-resolving kinetic inductance detectors (KIDs). The frequency noise of KIDs is typically limited by tunneling two-level systems (TLS), which originate from lattice defects in the dielectric materials required for PPCs. How the frequency noise level depends on the PPC’s dimensions has not been experimentally addressed. We measure the frequency noise of 56 resonators with a-SiC:H PPCs, which cover a factor of 44 in PPC area and a factor of 4 in dielectric thickness. To support the noise analysis, we measure the resonators’ TLS-induced power-dependent intrinsic loss and temperature-dependent resonance frequency shift. From the TLS models, we expect a geometry-independent microwave loss and resonance frequency shift, which is set by the TLS properties of the dielectric. However, we observe a thickness-dependent microwave loss and resonance frequency shift; this is explained by surface layers that limit the performance of PPC-based resonators. For a uniform dielectric, the frequency noise level should scale directly inversely with the PPC area and thickness. We observe that an increase in PPC size reduces the frequency noise, but the exact scaling is, in some cases, weaker than expected. Finally, we derive engineering guidelines for the design of KIDs based on PPC-based resonators.


  • Open Access

    Pointing Calibration of GroundBIRD Telescope Using Moon Observation Data

    by Y Sueno, J J A Baselmans, A H M Coppens, R T Génova-Santos, M Hattori, S Honda, K Karatsu, H Kutsuma, K Lee, T Nagasaki, et al.

    Understanding telescope pointing (i.e. line of sight) is important for observing the cosmic microwave background (CMB) and astronomical objects. The Moon is a candidate astronomical source for pointing calibration. Although the visible size of the Moon (30′) is larger than that of the planets, we can frequently observe the Moon once a month with a high signal-to-noise ratio. We developed a method for performing pointing calibration using observational data from the Moon. We considered the tilts of the telescope axes as well as the encoder and collimation offsets for pointing calibration. In addition, we evaluated the effects of the nonuniformity of the brightness temperature of the Moon, which is a dominant systematic error. As a result, we successfully achieved a pointing accuracy of 3.3′. This is one order of magnitude smaller than an angular resolution of 36′. This level of accuracy competes with past achievements in other ground-based CMB experiments using observational data from the planets.