Craig M. Jacobson
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Craig M. Jacobson has a total of 123 co-authors. Here are the top co-authors by number of shared publications:
- Cary B. Forest
University of Wisconsin-Madison
5 shared publications E. J. Spence
Department of Physics, University of Wisconsin-Madison, 1150 University Avenue, Madison, Wisconsin 53706, USA
5 shared publications- Mark D. Nornberg
University of Wisconsin-Madison
5 shared publications R. D. Kendrick
Department of Physics, University of Wisconsin-Madison, 1150 University Avenue, Madison, Wisconsin 53706, USA
5 shared publicationsT. Kozub
4 shared publicationsD.P. Lundberg
3 shared publications
Latest Publications
- 1 November 2026
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 97 (11)
Design of a Doppler backscattering diagnostic for WHAM: The Wisconsin HTS Axisymmetric Mirror
The Wisconsin HTS Axisymmetric Mirror (WHAM) is a compact high-field magnetic mirror. In such magnetic mirrors, cross-field transport is dominated by the flute instability [M. Rosenbluth and C. Longmire, Ann. Phys. 1, 120–140 (1957)]. To investigate density fluctuations associated with the flute instability, we designed a Doppler backscattering (DBS) diagnostic for WHAM, to be installed at the midplane port window. The diagnostic uses a two-channel tunable Ka-band (26.5–40 GHz) source and X-mode polarization. The azimuthal launch angle is set mechanically by rotating the external quasi-optical assembly. As such, the system is reconfigurable during dedicated setup periods. Using the Scotty beam-tracing code [V. H. Hall-Chen et al., Plasma Phys. Controlled Fusion 64, 095002 (2022)], we show that the proposed DBS system can measure density fluctuations with perpendicular wavenumbers |k⊥| ≤ 3 cm−1 over radial locations 0.7 ≤ ρ ≤ 0.9, where ρ is the normalized radial coordinate. This is achieved with probe frequencies between 28 and 38.5 GHz, an elevation launch angle of 0°, and azimuthal launch angles in the range of 1°–3°. The selected configurations have low mismatch angles at cutoff, |θm,c| < 1°. The quasi-optical system uses a Ka-band horn and a biconvex ultra-high molecular weight polyethylene lens and satisfies the port-access constraints in WHAM. The planned microwave system has a monostatic, homodyne architecture based on two phase-coupled Ka-band microwave channels. These two channels will be for the transmitted signal and coherent local oscillator for IQ downconversion, respectively. As the two phase-coupled channels can be independently tuned or swept with a controlled frequency offset, the same microwave chain is intended to retain compatibility with future profile-reflectometry operation.
- 1 November 2026
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 97 (11)
Design of a Doppler backscattering diagnostic for WHAM: The Wisconsin HTS Axisymmetric Mirror
The Wisconsin HTS Axisymmetric Mirror (WHAM) is a compact high-field magnetic mirror. In such magnetic mirrors, cross-field transport is dominated by the flute instability [M. Rosenbluth and C. Longmire, Ann. Phys. 1, 120–140 (1957)]. To investigate density fluctuations associated with the flute instability, we designed a Doppler backscattering (DBS) diagnostic for WHAM, to be installed at the midplane port window. The diagnostic uses a two-channel tunable Ka-band (26.5–40 GHz) source and X-mode polarization. The azimuthal launch angle is set mechanically by rotating the external quasi-optical assembly. As such, the system is reconfigurable during dedicated setup periods. Using the Scotty beam-tracing code [V. H. Hall-Chen et al., Plasma Phys. Controlled Fusion 64, 095002 (2022)], we show that the proposed DBS system can measure density fluctuations with perpendicular wavenumbers |k⊥| ≤ 3 cm−1 over radial locations 0.7 ≤ ρ ≤ 0.9, where ρ is the normalized radial coordinate. This is achieved with probe frequencies between 28 and 38.5 GHz, an elevation launch angle of 0°, and azimuthal launch angles in the range of 1°–3°. The selected configurations have low mismatch angles at cutoff, |θm,c| < 1°. The quasi-optical system uses a Ka-band horn and a biconvex ultra-high molecular weight polyethylene lens and satisfies the port-access constraints in WHAM. The planned microwave system has a monostatic, homodyne architecture based on two phase-coupled Ka-band microwave channels. These two channels will be for the transmitted signal and coherent local oscillator for IQ downconversion, respectively. As the two phase-coupled channels can be independently tuned or swept with a controlled frequency offset, the same microwave chain is intended to retain compatibility with future profile-reflectometry operation.
- Open Access
- 10 July 2026
- Published by Cambridge University Press (CUP) in Journal of Plasma Physics
- Vol. 92 (4) , E94
Confinement performance predictions for a high field axisymmetric tandem mirror – CORRIGENDUM
Confinement performance predictions for a high field axisymmetric tandem mirror – CORRIGENDUM - Volume 92 Issue 4
- 10 July 2026
- Published by Cambridge University Press (CUP) in Journal of Plasma Physics
- Vol. 92 (4) , E94
Open AccessConfinement performance predictions for a high field axisymmetric tandem mirror – CORRIGENDUM
Confinement performance predictions for a high field axisymmetric tandem mirror – CORRIGENDUM - Volume 92 Issue 4
- Open Access
- 5 May 2026
- Published by Elsevier in SSRN Electronic Journal
ParaTAN: Parametric Neutronics Modelling for Mirror Devices
Magnetic mirror fusion has seen renewed interest as a candidate for both fusion power plants and intense neutron sources, driven by advances in high-temperature superconducting magnets, neutral beam injection, and MHD stabilization of axisymmetric configurations. As mirror-type devices advance into pre-conceptual design, rapid and systematic evaluation of their neutronics performance is essential. This work presents ParaTAN, a parametric neutronics toolkit built on OpenMC that enables automated construction and systematic evaluation of simple and tandem mirror fusion devices. Two demonstration studies are presented. The first evaluates the shielding effectiveness of four candidate materials, B4C, WC, WB, and W2B5, for the high-field magnets of a simple mirror device. W2B5 emerges as the best-performing shield material, with axial shielding found to offer substantially better benefit than radial shielding. The second evaluates tritium breeding performance across four blanket concepts for a tandem mirror central cell, based on the following breeder materials: liquid lithium, PbLi eutectic, FLiBe, and Li4SiO4 pebble bed, spanning a range of blanket geometries and lithium enrichment levels. Among the engineering blanket compositions, the HCPB pebble bed with Be12Ti multiplication achieves the strongest breeding performance, approaching tritium self-sufficiency even at natural enrichment for sufficiently large blanket dimensions. PbLi requires larger geometries and higher enrichment levels to achieve self-sufficiency, but its liquid nature makes it an attractive candidate for integrated breeding and cooling. Liquid lithium and FLiBe exhibit more modest peak TBR values that plateau at lower levels relative to the multiplier-bearing concepts, requiring larger blanket dimensions to approach the self-sufficiency threshold. Future work will extend the tool's capabilities to include NBI shielding analysis, activation and shutdown dose rate calculations, and more plasma physics-informed parameterization of geometry and source profiles in response to changes in plasma equilibrium and temperature.
- 5 May 2026
- Published by Elsevier in SSRN Electronic Journal
Open AccessParaTAN: Parametric Neutronics Modelling for Mirror Devices
Magnetic mirror fusion has seen renewed interest as a candidate for both fusion power plants and intense neutron sources, driven by advances in high-temperature superconducting magnets, neutral beam injection, and MHD stabilization of axisymmetric configurations. As mirror-type devices advance into pre-conceptual design, rapid and systematic evaluation of their neutronics performance is essential. This work presents ParaTAN, a parametric neutronics toolkit built on OpenMC that enables automated construction and systematic evaluation of simple and tandem mirror fusion devices. Two demonstration studies are presented. The first evaluates the shielding effectiveness of four candidate materials, B4C, WC, WB, and W2B5, for the high-field magnets of a simple mirror device. W2B5 emerges as the best-performing shield material, with axial shielding found to offer substantially better benefit than radial shielding. The second evaluates tritium breeding performance across four blanket concepts for a tandem mirror central cell, based on the following breeder materials: liquid lithium, PbLi eutectic, FLiBe, and Li4SiO4 pebble bed, spanning a range of blanket geometries and lithium enrichment levels. Among the engineering blanket compositions, the HCPB pebble bed with Be12Ti multiplication achieves the strongest breeding performance, approaching tritium self-sufficiency even at natural enrichment for sufficiently large blanket dimensions. PbLi requires larger geometries and higher enrichment levels to achieve self-sufficiency, but its liquid nature makes it an attractive candidate for integrated breeding and cooling. Liquid lithium and FLiBe exhibit more modest peak TBR values that plateau at lower levels relative to the multiplier-bearing concepts, requiring larger blanket dimensions to approach the self-sufficiency threshold. Future work will extend the tool's capabilities to include NBI shielding analysis, activation and shutdown dose rate calculations, and more plasma physics-informed parameterization of geometry and source profiles in response to changes in plasma equilibrium and temperature.
- Open Access
- 31 July 2025
- Published by Cambridge University Press (CUP) in Journal of Plasma Physics
- Vol. 91 (4) , E110
Confinement performance predictions for a high field axisymmetric tandem mirror
This paper presents a Hammir tandem mirror confinement performance analysis based on Realta Fusion’s first-of-a-kind model for axisymmetric magnetic mirror fusion performance. This model uses an integrated end plug simulation model including, heating, equilibrium and transport combined with a new formulation of the plasma operation contours (POPCONs) technique for the tandem mirror central cell. Using this model in concert with machine learning optimization techniques, it is shown that an end plug utilizing high temperature superconducting magnets and modern neutral beams enables a classical tandem mirror pilot plant producing a fusion gain Q > 5. The approach here represents an important advance in tandem mirror design. The high-fidelity end plug model enables calculations of heating and transport in the highly non-Maxwellian end plug to be made more accurately. The detailed end plug modelling performed in this work has highlighted the importance of classical radial transport and neutral beam absorption efficiency on end plug viability. The central cell POPCON technique allows consideration of a wide range of parameters in the relatively simple near-Maxwellian central cell, facilitating the selection of more optimal central cell plasmas. These advances make it possible to find more conservative classical tandem mirror fusion pilot plant operating points with lower temperatures, neutral beam energies and end plug performance requirements than designs in the literature. Despite being more conservative, it is shown that these operating points have sufficient confinement performance to serve as the basis of a viable fusion pilot plant provided that they can be stabilized against magnetohydrodynamic and trapped particle modes.
- 31 July 2025
- Published by Cambridge University Press (CUP) in Journal of Plasma Physics
- Vol. 91 (4) , E110
Open AccessConfinement performance predictions for a high field axisymmetric tandem mirror
This paper presents a Hammir tandem mirror confinement performance analysis based on Realta Fusion’s first-of-a-kind model for axisymmetric magnetic mirror fusion performance. This model uses an integrated end plug simulation model including, heating, equilibrium and transport combined with a new formulation of the plasma operation contours (POPCONs) technique for the tandem mirror central cell. Using this model in concert with machine learning optimization techniques, it is shown that an end plug utilizing high temperature superconducting magnets and modern neutral beams enables a classical tandem mirror pilot plant producing a fusion gain Q > 5. The approach here represents an important advance in tandem mirror design. The high-fidelity end plug model enables calculations of heating and transport in the highly non-Maxwellian end plug to be made more accurately. The detailed end plug modelling performed in this work has highlighted the importance of classical radial transport and neutral beam absorption efficiency on end plug viability. The central cell POPCON technique allows consideration of a wide range of parameters in the relatively simple near-Maxwellian central cell, facilitating the selection of more optimal central cell plasmas. These advances make it possible to find more conservative classical tandem mirror fusion pilot plant operating points with lower temperatures, neutral beam energies and end plug performance requirements than designs in the literature. Despite being more conservative, it is shown that these operating points have sufficient confinement performance to serve as the basis of a viable fusion pilot plant provided that they can be stabilized against magnetohydrodynamic and trapped particle modes.
- 1 November 2018
- Published by AIP Publishing in Physics of Plasmas
- Vol. 25 (11) , 112506
Role of resistivity and viscosity in the excitation of stable m = 0 modes during the RFP sawtooth crash
Visco-resistive magnetohydrodynamic simulations are used to investigate the role of resistivity and viscosity in the reversed field pinch sawtooth crash. Specifically, we examine the temporal behavior of the linearly stable (m, n) = (0, 1) mode. Both volume-averaged dissipation and dissipation levels in the region near the m = 0 resonance are found to influence characteristic time scales. Increasing resistivity causes the mode rise time, fall time, and total crash duration to decrease, while increasing viscosity has the opposite effect. Examination of energy flow during the sawtooth crash reveals that despite the linear stability of the (0, 1) mode, it receives most of its energy from the mean current profile during the crash rather than from nonlinear interactions with other modes. Resistivity and viscosity do not impact mode behavior directly through dissipative energy loss but rather through modification of the large scale current profile evolution and radial structure of the mode. Computational results are compared to experimental data from the Madison Symmetric Torus and found to largely agree when resistivity and viscosity are similar.
- 1 November 2018
- Published by AIP Publishing in Physics of Plasmas
- Vol. 25 (11) , 112506
Role of resistivity and viscosity in the excitation of stable m = 0 modes during the RFP sawtooth crash
Visco-resistive magnetohydrodynamic simulations are used to investigate the role of resistivity and viscosity in the reversed field pinch sawtooth crash. Specifically, we examine the temporal behavior of the linearly stable (m, n) = (0, 1) mode. Both volume-averaged dissipation and dissipation levels in the region near the m = 0 resonance are found to influence characteristic time scales. Increasing resistivity causes the mode rise time, fall time, and total crash duration to decrease, while increasing viscosity has the opposite effect. Examination of energy flow during the sawtooth crash reveals that despite the linear stability of the (0, 1) mode, it receives most of its energy from the mean current profile during the crash rather than from nonlinear interactions with other modes. Resistivity and viscosity do not impact mode behavior directly through dissipative energy loss but rather through modification of the large scale current profile evolution and radial structure of the mode. Computational results are compared to experimental data from the Madison Symmetric Torus and found to largely agree when resistivity and viscosity are similar.
- 13 September 2016
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 87 (11) , 11E547
Upgrades to improve the usability, reliability, and spectral range of the MST Thomson scattering diagnostic
The Thomson scattering diagnostic on MST records both equilibrium and fluctuating electron temperature with a range capability of 10 eV–5 keV. Standard operation with two modified commercial Nd:YAG lasers allows measurements at rates of 1 kHz–25 kHz. Several subsystems of the diagnostic are being improved. The power supplies for the avalanche photodiode detectors (APDs) that record the scattered light are being replaced to improve usability, reliability, and maintainability. Each of the 144 APDs will have an individual rack mounted switching supply, with bias voltage adjustable to match the APD. Long-wavelength filters (1140 nm center, 80 nm bandwidth) have been added to the polychromators to improve capability to resolve non-Maxwellian distributions and to enable directed electron flow measurements. A supercontinuum (SC) pulsed white light source has replaced the tungsten halogen lamp previously used for spectral calibration of the polychromators. The SC source combines substantial brightness produced in nanosecond pulses with a spectrum that covers the entire range of the polychromators.
- 13 September 2016
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 87 (11) , 11E547
Upgrades to improve the usability, reliability, and spectral range of the MST Thomson scattering diagnostic
The Thomson scattering diagnostic on MST records both equilibrium and fluctuating electron temperature with a range capability of 10 eV–5 keV. Standard operation with two modified commercial Nd:YAG lasers allows measurements at rates of 1 kHz–25 kHz. Several subsystems of the diagnostic are being improved. The power supplies for the avalanche photodiode detectors (APDs) that record the scattered light are being replaced to improve usability, reliability, and maintainability. Each of the 144 APDs will have an individual rack mounted switching supply, with bias voltage adjustable to match the APD. Long-wavelength filters (1140 nm center, 80 nm bandwidth) have been added to the polychromators to improve capability to resolve non-Maxwellian distributions and to enable directed electron flow measurements. A supercontinuum (SC) pulsed white light source has replaced the tungsten halogen lamp previously used for spectral calibration of the polychromators. The SC source combines substantial brightness produced in nanosecond pulses with a spectrum that covers the entire range of the polychromators.
- 1 August 2016
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 87 (11) , 11E511
Identification and mitigation of stray laser light in the Thomson scattering system on the Madison Symmetric Torus (MST)
The Thomson scattering diagnostic on the Madison Symmetric Torus (MST) records excessive levels of stray Nd:YAG laser light. Stray light saturates the 1064 nm spectral channel in all polychromators, which prevents absolute electron density measurements via Rayleigh scattering calibration. Furthermore, stray light contaminates adjacent spectral channels for r/a ≥ 0.75, which renders the diagnostic unable to make electron temperature measurements at these radii. In situ measurements of stray light levels during a vacuum vessel vent are used to identify stray light sources and strategies for reduction of stray light levels. Numerical modeling using Zemax OpticStudio supports these measurements. The model of the vacuum vessel and diagnostic includes synthetic collection optics to enable direct comparison of measured and simulated stray light levels. Modeling produces qualitatively similar stray light distributions to MST measurements, and quantifies the mitigation effects of stray light mitigation strategies prior to implementation.
- 1 August 2016
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 87 (11) , 11E511
Identification and mitigation of stray laser light in the Thomson scattering system on the Madison Symmetric Torus (MST)
The Thomson scattering diagnostic on the Madison Symmetric Torus (MST) records excessive levels of stray Nd:YAG laser light. Stray light saturates the 1064 nm spectral channel in all polychromators, which prevents absolute electron density measurements via Rayleigh scattering calibration. Furthermore, stray light contaminates adjacent spectral channels for r/a ≥ 0.75, which renders the diagnostic unable to make electron temperature measurements at these radii. In situ measurements of stray light levels during a vacuum vessel vent are used to identify stray light sources and strategies for reduction of stray light levels. Numerical modeling using Zemax OpticStudio supports these measurements. The model of the vacuum vessel and diagnostic includes synthetic collection optics to enable direct comparison of measured and simulated stray light levels. Modeling produces qualitatively similar stray light distributions to MST measurements, and quantifies the mitigation effects of stray light mitigation strategies prior to implementation.
- 1 July 2013
- Published by Elsevier in Journal of Nuclear Materials
- Vol. 438, S1096-S1099
Results and future plans of the Lithium Tokamak eXperiment (LTX)
- 1 July 2013
- Published by Elsevier in Journal of Nuclear Materials
- Vol. 438, S1096-S1099
Results and future plans of the Lithium Tokamak eXperiment (LTX)
- 30 May 2012
- Published by IOP Publishing in Nuclear Fusion
- Vol. 52 (6) , 063025
Plasma equilibrium reconstructions in the lithium tokamak experiment
The lithium tokamak experiment (LTX) (R 0 = 0.4 m, a = 0.26 m) is designed to explore the low-recycling, lithium wall operating regime for magnetically confined plasmas. A set of shell quadrants internal to the vacuum vessel and conformal to the plasma last closed flux surface is designed to be coated with lithium to produce the lithium plasma-facing surface. The shell quadrants are highly conductive in order to maintain an even thermal distribution, but this conductivity also permits eddy currents to flow that can be larger in magnitude than the plasma current. Due to this effect, plasma start-up is greatly complicated as is the development of an applicable equilibrium solver code. A suitable code, LTX LRDFIT, has been developed and benchmarked and has now been used to compare plasma flux surface reconstructions for discharges before and after initial lithium wall conditioning. Dramatic improvements in plasma performance and shaping have been noted with the introduction of lithium.
- 30 May 2012
- Published by IOP Publishing in Nuclear Fusion
- Vol. 52 (6) , 063025
Plasma equilibrium reconstructions in the lithium tokamak experiment
The lithium tokamak experiment (LTX) (R 0 = 0.4 m, a = 0.26 m) is designed to explore the low-recycling, lithium wall operating regime for magnetically confined plasmas. A set of shell quadrants internal to the vacuum vessel and conformal to the plasma last closed flux surface is designed to be coated with lithium to produce the lithium plasma-facing surface. The shell quadrants are highly conductive in order to maintain an even thermal distribution, but this conductivity also permits eddy currents to flow that can be larger in magnitude than the plasma current. Due to this effect, plasma start-up is greatly complicated as is the development of an applicable equilibrium solver code. A suitable code, LTX LRDFIT, has been developed and benchmarked and has now been used to compare plasma flux surface reconstructions for discharges before and after initial lithium wall conditioning. Dramatic improvements in plasma performance and shaping have been noted with the introduction of lithium.