Guido David
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Guido David has a total of 26 co-authors. Here are the top co-authors by number of shared publications:
- J. D. Humphrey
Department of Biomedical Engineering and M.E. DeBakey Institute, Texas A&M University, College Station, TX, USA
3 shared publications J.D. Humphrey
2 shared publicationsR. M. Pedrigi
Department of Biomedical Engineering, Texas A&M University, College Station, TX 77843-3120, USA
2 shared publications- Akihiro Mizutani
Lab of Pharmacotherapeutics, Showa Pharmaceutical University, Tokyo, Japan
1 shared publication - Azra May Kabiri1 shared publication
Daisuke Mori
Department of Biomedical Engineering, Texas A&M University 337 Zachry Engineering Center, 3120 TAMU College Station, TX 77843-3120, USA
1 shared publication
Latest Publications
- 30 November 2021
- Published by Philippine-American Academy of Science and Engineering in SciEnggJ
- Vol. 14 (2) , 249-256
Solution to the Three-Player Gambler’s Ruin with Variable Bet Size Using Recursions Based on Multigraphs
This paper studies the three-player gambler’s ruin with variable bet size, that is, more than one chip may be transferred from one player to another. Weighted directed multigraphs were constructed to model the transitions between chip states. Linear systems are constructed based on the connections between nodes in these graphs. Solutions for the placing probabilities of each player are obtained from these linear systems. Expected time until ruin is solved by modeling the game as a Markov process. A numerical algorithm is developed to solve the No Limit three-player gambler’s ruin problem for any positive integer chip total.
- 30 November 2021
- Published by Philippine-American Academy of Science and Engineering in SciEnggJ
- Vol. 14 (2) , 249-256
Solution to the Three-Player Gambler’s Ruin with Variable Bet Size Using Recursions Based on Multigraphs
This paper studies the three-player gambler’s ruin with variable bet size, that is, more than one chip may be transferred from one player to another. Weighted directed multigraphs were constructed to model the transitions between chip states. Linear systems are constructed based on the connections between nodes in these graphs. Solutions for the placing probabilities of each player are obtained from these linear systems. Expected time until ruin is solved by modeling the game as a Markov process. A numerical algorithm is developed to solve the No Limit three-player gambler’s ruin problem for any positive integer chip total.
- 18 July 2021
- Published by Philippine-American Academy of Science and Engineering in SciEnggJ
- Vol. 14 (2) , 190-199
Multilevel Monte Carlo method for pricing Asian options under the square root process
Asian options are path dependent options whose payoff depends on the average price of an asset. The price of these options does not have closed form solutions. The multilevel Monte Carlo is a method for discretization with the application of the standard Monte Carlo method. This method is easy to implement and has less computational cost than the standard Monte Carlo method. The application of this method in pricing Asian options whose underlying asset follows the geometric Brownian motion has already been studied. However, this has not been applied in pricing Asian options where the underlying asset follows the square root process. We use the Riemann scheme to discretize the temporal integral of the square root process and a simulation algorithm based on the transition density of the square root process to determine the values of the square root process at specified times. We determined that the rate of mean square convergence of the Riemann sum in approximating the temporal integral of the square root is at least of order 1. The results are compared with those obtained using standard Monte Carlo in terms of computational cost. It is shown that the use of this method with the Riemann scheme as discretization scheme is effective in terms of reducing computational cost as compared to the standard Monte Carlo method.
- 18 July 2021
- Published by Philippine-American Academy of Science and Engineering in SciEnggJ
- Vol. 14 (2) , 190-199
Multilevel Monte Carlo method for pricing Asian options under the square root process
Asian options are path dependent options whose payoff depends on the average price of an asset. The price of these options does not have closed form solutions. The multilevel Monte Carlo is a method for discretization with the application of the standard Monte Carlo method. This method is easy to implement and has less computational cost than the standard Monte Carlo method. The application of this method in pricing Asian options whose underlying asset follows the geometric Brownian motion has already been studied. However, this has not been applied in pricing Asian options where the underlying asset follows the square root process. We use the Riemann scheme to discretize the temporal integral of the square root process and a simulation algorithm based on the transition density of the square root process to determine the values of the square root process at specified times. We determined that the rate of mean square convergence of the Riemann sum in approximating the temporal integral of the square root is at least of order 1. The results are compared with those obtained using standard Monte Carlo in terms of computational cost. It is shown that the use of this method with the Riemann scheme as discretization scheme is effective in terms of reducing computational cost as compared to the standard Monte Carlo method.
- 16 June 2015
- Published by World Scientific Pub Co Pte Ltd in Journal of Mechanics in Medicine and Biology
- Vol. 15 (03)
RUPTURE MODEL OF INTRACRANIAL SACCULAR ANEURYSMS DUE TO HYPERTENSION
The risk of rupture of intracranial saccular aneurysms is one of the leading dilemmas for patients and neurologists. Although the probability of rupture is small, the consequences of rupture are usually fatal or crippling, and a concern for the patient is whether or not to treat an existing aneurysm. In this paper, an idealized model of saccular aneurysms with assumed Fung material behavior was investigated for rupture potential when the stresses exceeded the maximum wall strength of the aneurysm wall. Numerical simulations used various levels of blood pressure, from normal to hypertensive, in order to determine correlations of aneurysm size and risk of rupture. Results showed that hypertensive individuals harboring cerebral aneurysms with a size of at least 6 mm are at risk.
- 16 June 2015
- Published by World Scientific Pub Co Pte Ltd in Journal of Mechanics in Medicine and Biology
- Vol. 15 (03)
RUPTURE MODEL OF INTRACRANIAL SACCULAR ANEURYSMS DUE TO HYPERTENSION
The risk of rupture of intracranial saccular aneurysms is one of the leading dilemmas for patients and neurologists. Although the probability of rupture is small, the consequences of rupture are usually fatal or crippling, and a concern for the patient is whether or not to treat an existing aneurysm. In this paper, an idealized model of saccular aneurysms with assumed Fung material behavior was investigated for rupture potential when the stresses exceeded the maximum wall strength of the aneurysm wall. Numerical simulations used various levels of blood pressure, from normal to hypertensive, in order to determine correlations of aneurysm size and risk of rupture. Results showed that hypertensive individuals harboring cerebral aneurysms with a size of at least 6 mm are at risk.
- Open Access
- 26 February 2015
- Published by Academic Publications in International Journal of Pure and Apllied Mathematics
- Vol. 99 (2) , 145-151
SYMMETRIC FORM OF THE VON NEUMANN POKER MODEL
- 26 February 2015
- Published by Academic Publications in International Journal of Pure and Apllied Mathematics
- Vol. 99 (2) , 145-151
Open AccessSYMMETRIC FORM OF THE VON NEUMANN POKER MODEL
- Open Access
- 1 January 2014
- Published by Springer Nature in Lecture Notes in Computer Science
- p. 29-35
Cellular Automata Model of Urbanization in Camiguin, Philippines
- 1 January 2014
- Published by Springer Nature in Lecture Notes in Computer Science
- p. 29-35
Open AccessCellular Automata Model of Urbanization in Camiguin, Philippines
- 1 June 2007
- Published by Elsevier in Vision Research
- Vol. 47 (13) , 1781-1789
Regional mechanical properties and stress analysis of the human anterior lens capsule
- 1 June 2007
- Published by Elsevier in Vision Research
- Vol. 47 (13) , 1781-1789
Regional mechanical properties and stress analysis of the human anterior lens capsule
- 1 June 2007
- Published by Taylor & Francis in Computer Methods in Biomechanics and Biomedical Engineering
- Vol. 10 (3) , 237-243
Finite element model of stresses in the anterior lens capsule of the eye
Continuum biomechanics continues to aid in the design of clinical procedures and biomedical devices. Such design requires detailed information on the biomechanical properties of the tissues of interest as well as appropriate methods of analysis. In this paper, we use a fully nonlinear, virtual work based finite element method to study the normal stress field in the anterior lens capsule of the porcine eye. The analysis shows that recently measured regional variations in material symmetry may combine with regional variations in membrane thickness to yield a nearly uniform and equibiaxial stress field in normalcy. These findings are discussed in terms of potential implications to the underlying mechanobiology and in particular, in terms of perturbations in stress that result from cataract surgery, the most commonly performed surgical procedure in North America.
- 1 June 2007
- Published by Taylor & Francis in Computer Methods in Biomechanics and Biomedical Engineering
- Vol. 10 (3) , 237-243
Finite element model of stresses in the anterior lens capsule of the eye
Continuum biomechanics continues to aid in the design of clinical procedures and biomedical devices. Such design requires detailed information on the biomechanical properties of the tissues of interest as well as appropriate methods of analysis. In this paper, we use a fully nonlinear, virtual work based finite element method to study the normal stress field in the anterior lens capsule of the porcine eye. The analysis shows that recently measured regional variations in material symmetry may combine with regional variations in membrane thickness to yield a nearly uniform and equibiaxial stress field in normalcy. These findings are discussed in terms of potential implications to the underlying mechanobiology and in particular, in terms of perturbations in stress that result from cataract surgery, the most commonly performed surgical procedure in North America.
- 26 July 2006
- Published by ASME International in Journal of Biomechanical Engineering
- Vol. 129 (1) , 121-125
Altered Multiaxial Mechanical Properties of the Porcine Anterior Lens Capsule Cultured in High Glucose
Hyperglycemia can alter the mechanical properties of tissues through the formation of advanced glycation endproducts in matrix proteins that have long half-lives. We used a custom experimental system and subdomain finite element method to quantify alterations in the regional multiaxial mechanical properties of porcine lens capsules that were cultured for 8 or 14 weeks in high glucose versus control media. Findings revealed that high glucose significantly stiffened the capsules in both the circumferential and the meridional directions, but it did not affect the known regional variations in anisotropy. Such information could be important in the design of both improved clinical procedures and intraocular implants for diabetic patients.
- 26 July 2006
- Published by ASME International in Journal of Biomechanical Engineering
- Vol. 129 (1) , 121-125
Altered Multiaxial Mechanical Properties of the Porcine Anterior Lens Capsule Cultured in High Glucose
Hyperglycemia can alter the mechanical properties of tissues through the formation of advanced glycation endproducts in matrix proteins that have long half-lives. We used a custom experimental system and subdomain finite element method to quantify alterations in the regional multiaxial mechanical properties of porcine lens capsules that were cultured for 8 or 14 weeks in high glucose versus control media. Findings revealed that high glucose significantly stiffened the capsules in both the circumferential and the meridional directions, but it did not affect the known regional variations in anisotropy. Such information could be important in the design of both improved clinical procedures and intraocular implants for diabetic patients.
- 26 June 2006
- Published by ASME International in Journal of Biomechanical Engineering
- Vol. 129 (1) , 97-104
Regional Multiaxial Mechanical Properties of the Porcine Anterior Lens Capsule
The lens capsule of the eye plays fundamental biomechanical roles in both normal physiological processes and clinical interventions. There has been modest attention given to the mechanical properties of this important membrane, however, and prior studies have focused on 1-D analyses of the data. We present results that suggest that the porcine anterior lens capsule has a complex, regionally dependent, nonlinear, anisotropic behavior. Specifically, using a subdomain inverse finite element method to analyze data collected via a new biplane video-based test system, we found that the lens capsule is nearly isotropic (in-plane) near the pole but progressively stiffer in the circumferential compared to the meridional direction as one approaches the equator. Because the porcine capsule is a good model of the young human capsule, there is strong motivation to determine if similar regional variations exist in the human lens capsule for knowledge of such complexities may allow us to improve the design of surgical procedures and implants.
- 26 June 2006
- Published by ASME International in Journal of Biomechanical Engineering
- Vol. 129 (1) , 97-104
Regional Multiaxial Mechanical Properties of the Porcine Anterior Lens Capsule
The lens capsule of the eye plays fundamental biomechanical roles in both normal physiological processes and clinical interventions. There has been modest attention given to the mechanical properties of this important membrane, however, and prior studies have focused on 1-D analyses of the data. We present results that suggest that the porcine anterior lens capsule has a complex, regionally dependent, nonlinear, anisotropic behavior. Specifically, using a subdomain inverse finite element method to analyze data collected via a new biplane video-based test system, we found that the lens capsule is nearly isotropic (in-plane) near the pole but progressively stiffer in the circumferential compared to the meridional direction as one approaches the equator. Because the porcine capsule is a good model of the young human capsule, there is strong motivation to determine if similar regional variations exist in the human lens capsule for knowledge of such complexities may allow us to improve the design of surgical procedures and implants.
- 31 January 2005
- Published by ASME International in Journal of Biomechanical Engineering
- Vol. 127 (3) , 549-553
Stress Distribution in a Circular Membrane With a Central Fixation
Clinical interventions can change the mechanical environment of the tissues targeted for therapy. In order to design better procedures, it is important to understand cellular responses to altered mechanical stress. Rigid fixation is one example of a constraint imposed on living tissues as a result of implanted devices. This results in disturbed stress and strain fields, with potentially strong gradients. Herein, we numerically solve the governing nonlinear ordinary differential equation for the stress distribution in a finitely deformed anisotropic circular membrane with a concentric fixation by applying a zero-displacement condition at the inner circumference. Results show that rigid fixations yield distributions of stress and strain that are markedly different from tissue defects with traction-free boundaries. Moreover, the material anisotropy plays a significant role in the manner the stress redistributes regardless of the size of fixation. The present study will contribute to the design of experiments to determine cellular reactions involved in the failure of interventional treatments.
- 31 January 2005
- Published by ASME International in Journal of Biomechanical Engineering
- Vol. 127 (3) , 549-553
Stress Distribution in a Circular Membrane With a Central Fixation
Clinical interventions can change the mechanical environment of the tissues targeted for therapy. In order to design better procedures, it is important to understand cellular responses to altered mechanical stress. Rigid fixation is one example of a constraint imposed on living tissues as a result of implanted devices. This results in disturbed stress and strain fields, with potentially strong gradients. Herein, we numerically solve the governing nonlinear ordinary differential equation for the stress distribution in a finitely deformed anisotropic circular membrane with a concentric fixation by applying a zero-displacement condition at the inner circumference. Results show that rigid fixations yield distributions of stress and strain that are markedly different from tissue defects with traction-free boundaries. Moreover, the material anisotropy plays a significant role in the manner the stress redistributes regardless of the size of fixation. The present study will contribute to the design of experiments to determine cellular reactions involved in the failure of interventional treatments.