Stefanie Croghan
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Stefanie Croghan has a total of 167 co-authors. Here are the top co-authors by number of shared publications:
James Forde
Department of Urology, Beaumont Hospital, Ireland
10 shared publications- Niall Francis Davis
Department of Urology, Beaumont Hospital, Dublin, Ireland
7 shared publications Barry B. McGuire
Department of Surgical Affairs, Royal College of Surgeons in Ireland, Dublin, Ireland
4 shared publications- Fergal Joseph O'BRien
Royal College of Surgeons in Ireland
4 shared publications Michael T. Walsh
School of Engineering University of Limerick Castletroy, Co. Limerick Ireland
4 shared publicationsNiall F. Davis
4 shared publications
Latest Publications
- Open Access
- 30 June 2025
- Published by Springer Nature in World Journal of Urology
- Vol. 43 (1) , 1-8
Novel non-invasive intrarenal pressure monitoring devices in flexible ureteroscopy: an in-vitro comparative study
Purpose: Intrarenal pressure monitoring is emerging as an important tool in flexible ureteroscopy. Novel non-invasive intrarenal pressure monitoring devices are introduced. We evaluated the pressure readings simultaneously across four novel non-invasive intrarenal pressure monitoring devices against the urodynamic system. Materials and methods: Two IRP monitoring single-use flexible ureteroscopy: LithoVue Elite ™ (Boston Scientific Corporation, Marlborough, MA, USA); ZebraScope ™ (Happiness Works Medical Instruments Co., Ltd, Anhui, China); two intelligent intrarenal system integrated with irrigation and suction via flexible and navigable suction ureteral access sheath: i-MIMERsys ™ (ZSR Biomedical Technology Co., Ltd, Dongguan, China); Tidor ™ (YiGao Medical Technology Co., Ltd, Zhejiang, China) were tested against MMS/Laborie Nexam Pro Urodynamic System (Laborie Medical Technologies Corporation, Portsmouth, USA). Results: The degree of agreement between measurements from urodynamic system and the experimented device was demonstrated by Bland–Altman plots and intraclass correlation coefficients (ICCs). Compared to the urodynamic system, the average difference ± standard deviation of LithoVue Elite™ was 0.26 ± 1.75mmHg; ZebraScope™ 3.22 ± 1.86mHg, i-MIMERsys™ 0.96 ± 2.26mmhg; Tidor™ 1.09 ± 2.57mmHg. Pressure measured by LithoVue Elite™, ZebraScope™, i-MIMERsys™ and Tidor™ to urodynamic system showed excellent ICCs of 0.975 ( p < 0.001), 0.915( p = 0.016), 0.955( p < 0.001) and 0.937( p < 0.001) respectively. Conclusion: Pressure recordings from four novel non-invasive intrarenal monitoring devices, namely flexible ureteroscopes—LithoVue Elite ™ , ZebraScope ™ ; and intelligent IRP monitoring systems via flexible and navigable suction ureteral access sheaths — i-MIMERsys ™ , Tidor ™ . were comparable to that of urodynamic system. This in-vitro study verifies that such non-invasive devices provide reliable data for monitoring intrarenal pressure changes.
- 30 June 2025
- Published by Springer Nature in World Journal of Urology
- Vol. 43 (1) , 1-8
Open AccessNovel non-invasive intrarenal pressure monitoring devices in flexible ureteroscopy: an in-vitro comparative study
Purpose: Intrarenal pressure monitoring is emerging as an important tool in flexible ureteroscopy. Novel non-invasive intrarenal pressure monitoring devices are introduced. We evaluated the pressure readings simultaneously across four novel non-invasive intrarenal pressure monitoring devices against the urodynamic system. Materials and methods: Two IRP monitoring single-use flexible ureteroscopy: LithoVue Elite ™ (Boston Scientific Corporation, Marlborough, MA, USA); ZebraScope ™ (Happiness Works Medical Instruments Co., Ltd, Anhui, China); two intelligent intrarenal system integrated with irrigation and suction via flexible and navigable suction ureteral access sheath: i-MIMERsys ™ (ZSR Biomedical Technology Co., Ltd, Dongguan, China); Tidor ™ (YiGao Medical Technology Co., Ltd, Zhejiang, China) were tested against MMS/Laborie Nexam Pro Urodynamic System (Laborie Medical Technologies Corporation, Portsmouth, USA). Results: The degree of agreement between measurements from urodynamic system and the experimented device was demonstrated by Bland–Altman plots and intraclass correlation coefficients (ICCs). Compared to the urodynamic system, the average difference ± standard deviation of LithoVue Elite™ was 0.26 ± 1.75mmHg; ZebraScope™ 3.22 ± 1.86mHg, i-MIMERsys™ 0.96 ± 2.26mmhg; Tidor™ 1.09 ± 2.57mmHg. Pressure measured by LithoVue Elite™, ZebraScope™, i-MIMERsys™ and Tidor™ to urodynamic system showed excellent ICCs of 0.975 ( p < 0.001), 0.915( p = 0.016), 0.955( p < 0.001) and 0.937( p < 0.001) respectively. Conclusion: Pressure recordings from four novel non-invasive intrarenal monitoring devices, namely flexible ureteroscopes—LithoVue Elite ™ , ZebraScope ™ ; and intelligent IRP monitoring systems via flexible and navigable suction ureteral access sheaths — i-MIMERsys ™ , Tidor ™ . were comparable to that of urodynamic system. This in-vitro study verifies that such non-invasive devices provide reliable data for monitoring intrarenal pressure changes.
- Open Access
- 6 May 2025
- Published by Springer Nature in Journal of Robotic Surgery
- Vol. 19 (1) , 1-12
A national cross-sectional analysis of stakeholder views regarding the practice and governance of robotic surgery
The study objective was to explore the views of key national stakeholders regarding the practice and governance of robotic surgery in Ireland. A literature review and analysis by two expert robotic surgeons was used to design a customised questionnaire, interrogating respondent perceptions of key robotic surgical areas, including surgical practice, governance, audit and key performance indicators (KPIs). The questionnaire was disseminated via specialty representatives, inviting responses from robotic surgeons, senior trainees, bedside assistants, clinical nurse managers, hospital management and industry partners. The responses were compiled and analysed, with thematic analysis applied to free-text data. Responses were received from 87 stakeholders, with representation from all invited professional groups, surgical specialties and national geographical regions. The largest respondent cohort was consultant robotic surgeons ( n = 61); estimated response rate 76.3%. Most respondents were in favour of proctorship/mentorship arrangements for early-career surgeons, with support expressed for external proctors (80.5%, n = 70), internal proctors (88.5%, n = 77) and peer-to-peer mentoring (87.4%, n = 76). The minimum average number of robotic cases necessary for a trained surgeon to maintain competency was most frequently perceived as 1 per fortnight (39.3%, n = 24), or 1 per week (37.7%, n = 23). The recording of KPIs was believed to be important at both unit level [93.1% ( n = 81) agree] and surgeon level (94.3% ( n = 82) agree). Ninety-five percent of respondents ( n = 83), thought institutions should have robotic governance committees. Strong support [83.9% ( n = 73)] was expressed for the creation of a national guideline or governance document for the practice of robotic surgery. This national, pan-specialty robotic surgery stakeholder survey is the first of its kind. It identifies strong national support for continued advances in the training and governance of robotic surgery, with consensus for institutional oversight of robotic surgery and the development of a national guidelines for the conduct of robotic surgery.
- 6 May 2025
- Published by Springer Nature in Journal of Robotic Surgery
- Vol. 19 (1) , 1-12
Open AccessA national cross-sectional analysis of stakeholder views regarding the practice and governance of robotic surgery
The study objective was to explore the views of key national stakeholders regarding the practice and governance of robotic surgery in Ireland. A literature review and analysis by two expert robotic surgeons was used to design a customised questionnaire, interrogating respondent perceptions of key robotic surgical areas, including surgical practice, governance, audit and key performance indicators (KPIs). The questionnaire was disseminated via specialty representatives, inviting responses from robotic surgeons, senior trainees, bedside assistants, clinical nurse managers, hospital management and industry partners. The responses were compiled and analysed, with thematic analysis applied to free-text data. Responses were received from 87 stakeholders, with representation from all invited professional groups, surgical specialties and national geographical regions. The largest respondent cohort was consultant robotic surgeons ( n = 61); estimated response rate 76.3%. Most respondents were in favour of proctorship/mentorship arrangements for early-career surgeons, with support expressed for external proctors (80.5%, n = 70), internal proctors (88.5%, n = 77) and peer-to-peer mentoring (87.4%, n = 76). The minimum average number of robotic cases necessary for a trained surgeon to maintain competency was most frequently perceived as 1 per fortnight (39.3%, n = 24), or 1 per week (37.7%, n = 23). The recording of KPIs was believed to be important at both unit level [93.1% ( n = 81) agree] and surgeon level (94.3% ( n = 82) agree). Ninety-five percent of respondents ( n = 83), thought institutions should have robotic governance committees. Strong support [83.9% ( n = 73)] was expressed for the creation of a national guideline or governance document for the practice of robotic surgery. This national, pan-specialty robotic surgery stakeholder survey is the first of its kind. It identifies strong national support for continued advances in the training and governance of robotic surgery, with consensus for institutional oversight of robotic surgery and the development of a national guidelines for the conduct of robotic surgery.
- 14 December 2024
- Published by Springer Nature in World Journal of Urology
- Vol. 43 (1) , 1-8
Comparison of the mechanical properties of porcine buccal mucosa and ureter and the clinical implications
Purpose Buccal mucosal grafts have a well-established role in urology regarding the management of ureteric stricture disease. Despite its established use as a graft material there is a lack of data on the mechanical properties of buccal mucosa. We aim to compare the passive mechanical properties of porcine buccal mucosa with the ureter. Materials and methods Buccal mucosa (n = 20) and ureteric specimens (n = 21) were harvested from 19 domestic pigs at the time of euthanasia. Mechanical testing was performed using a uniaxial tensometer to generate stress-strain curves. From these curves, ultimate tensile strength and elastic modulus were calculated. Data was analysed, and one-way ANOVA testing was used to assess for significance variation in mechanical response due to direction of testing, and between tissue types. Results and conclusions Porcine ureteric specimens displayed mechanical anisotropy, with a significant difference in the elastic modulus depending on the direction of testing (p = 0.005), and a higher mean ultimate tensile strength in the longitudinal (498.09 kPa) compared to the transverse (263.99 kPa) direction (p = 0.0005). Buccal mucosa was isotropic with no significant difference in elastic modulus or ultimate tensile strength according to direction of testing. Comparison of tissue types showed a significantly greater mean ultimate tensile strength in the longitudinal direction (p = 0.002) in ureter compared to buccal mucosa. We present the first comparison of the mechanical properties of buccal mucosa with ureter, and demonstrate significant variation in elastic modulus and ultimate tensile strength between the tissue types. These findings have important clinical implications for physiological function and in the design of alternative approaches for reconstruction in buccal mucosa grafted ureters.
- 14 December 2024
- Published by Springer Nature in World Journal of Urology
- Vol. 43 (1) , 1-8
Comparison of the mechanical properties of porcine buccal mucosa and ureter and the clinical implications
Purpose Buccal mucosal grafts have a well-established role in urology regarding the management of ureteric stricture disease. Despite its established use as a graft material there is a lack of data on the mechanical properties of buccal mucosa. We aim to compare the passive mechanical properties of porcine buccal mucosa with the ureter. Materials and methods Buccal mucosa (n = 20) and ureteric specimens (n = 21) were harvested from 19 domestic pigs at the time of euthanasia. Mechanical testing was performed using a uniaxial tensometer to generate stress-strain curves. From these curves, ultimate tensile strength and elastic modulus were calculated. Data was analysed, and one-way ANOVA testing was used to assess for significance variation in mechanical response due to direction of testing, and between tissue types. Results and conclusions Porcine ureteric specimens displayed mechanical anisotropy, with a significant difference in the elastic modulus depending on the direction of testing (p = 0.005), and a higher mean ultimate tensile strength in the longitudinal (498.09 kPa) compared to the transverse (263.99 kPa) direction (p = 0.0005). Buccal mucosa was isotropic with no significant difference in elastic modulus or ultimate tensile strength according to direction of testing. Comparison of tissue types showed a significantly greater mean ultimate tensile strength in the longitudinal direction (p = 0.002) in ureter compared to buccal mucosa. We present the first comparison of the mechanical properties of buccal mucosa with ureter, and demonstrate significant variation in elastic modulus and ultimate tensile strength between the tissue types. These findings have important clinical implications for physiological function and in the design of alternative approaches for reconstruction in buccal mucosa grafted ureters.
- 11 October 2024
- Published by Elsevier in The Surgeon
- Vol. 23 (2) , e86-e91
Utilising a modified accelerated Delphi process to develop a national multidisciplinary consensus on peri-operative optimisation of patients with obesity undergoing non-bariatric surgery
- 11 October 2024
- Published by Elsevier in The Surgeon
- Vol. 23 (2) , e86-e91
Utilising a modified accelerated Delphi process to develop a national multidisciplinary consensus on peri-operative optimisation of patients with obesity undergoing non-bariatric surgery
- 6 August 2024
- Published by Wiley in BJU International
- Vol. 134 (5) , 826-833
Human in vivo baseline intrarenal pressure, peristaltic activity and response to ureteric stenting
Objectives: To assess human in vivo intrarenal pressure (IRP) and peristaltic activity at baseline and after ureteric stent placement, using a narrow calibre pressure guidewire placed retrogradely in the renal pelvis. Patients and Methods: A prospective, multi‐institutional study recruiting consenting patients undergoing ureteroscopy was designed with ethical approval. Prior to ureteroscopy, the urinary bladder was emptied and the COMET™ II pressure guidewire (Boston Scientific) was advanced retrogradely via the ureteric orifice to the renal pelvis. Baseline IRPs were recorded for 1–2 min. At procedure completion, following ureteric stent insertion, IRPs were recorded for another 1–2 min. Statistical analysis of mean baseline IRP, peristaltic waveforms and frequency of peristaltic contractions was performed, thereby analysing the influence of patient variables and ureteric stenting. Results: A total of 100 patients were included. Baseline mean (±SD) IRP was 16.76 (6.4) mmHg in the renal pelvis, with maximum peristaltic IRP peaks reaching a mean (SD) of 25.75 (17.9) mmHg. Peristaltic activity generally occurred in a rhythmic, coordinated fashion, with a mean (SD) interval of 5.63 (3.08) s between peaks. On univariate analysis, higher baseline IRP was observed with male sex, preoperative hydronephrosis, and preoperative ureteric stenting. On linear regression, male sex was no longer statistically significant, whilst the latter two variables remained significant ( P = 0.004; P < 0.001). The mean (SD) baseline IRP in the non‐hydronephrotic, unstented cohort was 14.19 (4.39) mmHg. Age, α‐blockers and calcium channel blockers did not significantly influence IRP, and no measured variables influenced peristaltic activity. Immediately after ureteric stent insertion, IRP decreased (mean [SD] 15.18 [5.28] vs 16.76 [6.4] mmHg, P = 0.004), whilst peristaltic activity was maintained. Conclusions: Human in vivo mean (SD) baseline IRP is 14.19 (4.39) mmHg in normal kidneys and increases with both hydronephrosis and preoperative ureteric stenting. Mean (SD) peristaltic peak IRP values of 25.75 (17.9) mmHg are reached in the renal pelvis every 3–7 s and maintained in the early post‐stent period.
- 6 August 2024
- Published by Wiley in BJU International
- Vol. 134 (5) , 826-833
Human in vivo baseline intrarenal pressure, peristaltic activity and response to ureteric stenting
Objectives: To assess human in vivo intrarenal pressure (IRP) and peristaltic activity at baseline and after ureteric stent placement, using a narrow calibre pressure guidewire placed retrogradely in the renal pelvis. Patients and Methods: A prospective, multi‐institutional study recruiting consenting patients undergoing ureteroscopy was designed with ethical approval. Prior to ureteroscopy, the urinary bladder was emptied and the COMET™ II pressure guidewire (Boston Scientific) was advanced retrogradely via the ureteric orifice to the renal pelvis. Baseline IRPs were recorded for 1–2 min. At procedure completion, following ureteric stent insertion, IRPs were recorded for another 1–2 min. Statistical analysis of mean baseline IRP, peristaltic waveforms and frequency of peristaltic contractions was performed, thereby analysing the influence of patient variables and ureteric stenting. Results: A total of 100 patients were included. Baseline mean (±SD) IRP was 16.76 (6.4) mmHg in the renal pelvis, with maximum peristaltic IRP peaks reaching a mean (SD) of 25.75 (17.9) mmHg. Peristaltic activity generally occurred in a rhythmic, coordinated fashion, with a mean (SD) interval of 5.63 (3.08) s between peaks. On univariate analysis, higher baseline IRP was observed with male sex, preoperative hydronephrosis, and preoperative ureteric stenting. On linear regression, male sex was no longer statistically significant, whilst the latter two variables remained significant ( P = 0.004; P < 0.001). The mean (SD) baseline IRP in the non‐hydronephrotic, unstented cohort was 14.19 (4.39) mmHg. Age, α‐blockers and calcium channel blockers did not significantly influence IRP, and no measured variables influenced peristaltic activity. Immediately after ureteric stent insertion, IRP decreased (mean [SD] 15.18 [5.28] vs 16.76 [6.4] mmHg, P = 0.004), whilst peristaltic activity was maintained. Conclusions: Human in vivo mean (SD) baseline IRP is 14.19 (4.39) mmHg in normal kidneys and increases with both hydronephrosis and preoperative ureteric stenting. Mean (SD) peristaltic peak IRP values of 25.75 (17.9) mmHg are reached in the renal pelvis every 3–7 s and maintained in the early post‐stent period.
- 2 August 2024
- Published by BJS Foundation Limited
Author response to comment on: Intrarenal pressure with hand-pump or pressurized-bag irrigation: randomized clinical trial at retrograde intrarenal surgery
Read our post titled 'Author response to comment on: Intrarenal pressure with hand-pump or pressurized-bag irrigation: randomized clinical trial at retrograde intrarenal surgery'.
- 2 August 2024
- Published by BJS Foundation Limited
Author response to comment on: Intrarenal pressure with hand-pump or pressurized-bag irrigation: randomized clinical trial at retrograde intrarenal surgery
Read our post titled 'Author response to comment on: Intrarenal pressure with hand-pump or pressurized-bag irrigation: randomized clinical trial at retrograde intrarenal surgery'.
- Open Access
- 12 June 2024
- Published by Oxford University Press (OUP) in British Journal of Surgery
- Vol. 111 (6)
Intrarenal pressure with hand-pump or pressurized-bag irrigation: randomized clinical trial at retrograde intrarenal surgery
Background: The aim was to ascertain the impact of irrigation technique on human intrarenal pressure during retrograde intrarenal surgery. Methods: A parallel randomized trial recruited patients across three hospital sites. Patients undergoing retrograde intrarenal surgery for renal stone treatment with an 11/13-Fr ureteral access sheath were allocated randomly to 100 mmHg pressurized-bag (PB) or manual hand-pump (HP) irrigation. The primary outcome was mean procedural intrarenal pressure. Secondary outcomes included maximum intrarenal pressure, variance, visualization, HP force of usage, procedure duration, stone clearance, and clinical outcomes. Live intrarenal pressure monitoring was performed using a COMETTMII pressure guidewire, deployed cystoscopically to the renal pelvis. The operating team was blinded to the intrarenal pressure. Results: Thirty-eight patients were randomized between July and November 2023 (trial closure). The final analysis included 34 patients (PB 16; HP 18). Compared with PB irrigation, HP irrigation resulted in significantly higher mean intrarenal pressure (mean(s.d.) 62.29(27.45) versus 38.16(16.84) mmHg; 95% c.i. for difference in means (MD) 7.97 to 40.29 mmHg; P = 0.005) and maximum intrarenal pressure (192.71(106.23) versus 68.04(24.16) mmHg; 95% c.i. for MD 70.76 to 178.59 mmHg; P < 0.001), along with greater variance in intrarenal pressure (log transformed) (6.23(1.59) versus 4.60(1.30); 95% c.i. for MD 0.62 to 2.66; P = 0.001). Surgeon satisfaction with procedural vision reported on a scale of 10 was higher with PB compared with HP irrigation (mean(s.d.) 8.75(0.58) versus 6.28(1.27); 95% c.i. for MD 1.79 to 3.16; P < 0.001). Subjective HP usage force did not correlate significantly with transmitted intrarenal pressure (Pearson R = −0.15, P = 0.57). One patient (HP arm) developed urosepsis. Conclusion: Manual HP irrigation resulted in higher and more fluctuant intrarenal pressure trace (with inferior visual clarity) than 100-mmHg PB irrigation. Registration number: osf.io/jmg2h (https://osf.io/).
- 12 June 2024
- Published by Oxford University Press (OUP) in British Journal of Surgery
- Vol. 111 (6)
Open AccessIntrarenal pressure with hand-pump or pressurized-bag irrigation: randomized clinical trial at retrograde intrarenal surgery
Background: The aim was to ascertain the impact of irrigation technique on human intrarenal pressure during retrograde intrarenal surgery. Methods: A parallel randomized trial recruited patients across three hospital sites. Patients undergoing retrograde intrarenal surgery for renal stone treatment with an 11/13-Fr ureteral access sheath were allocated randomly to 100 mmHg pressurized-bag (PB) or manual hand-pump (HP) irrigation. The primary outcome was mean procedural intrarenal pressure. Secondary outcomes included maximum intrarenal pressure, variance, visualization, HP force of usage, procedure duration, stone clearance, and clinical outcomes. Live intrarenal pressure monitoring was performed using a COMETTMII pressure guidewire, deployed cystoscopically to the renal pelvis. The operating team was blinded to the intrarenal pressure. Results: Thirty-eight patients were randomized between July and November 2023 (trial closure). The final analysis included 34 patients (PB 16; HP 18). Compared with PB irrigation, HP irrigation resulted in significantly higher mean intrarenal pressure (mean(s.d.) 62.29(27.45) versus 38.16(16.84) mmHg; 95% c.i. for difference in means (MD) 7.97 to 40.29 mmHg; P = 0.005) and maximum intrarenal pressure (192.71(106.23) versus 68.04(24.16) mmHg; 95% c.i. for MD 70.76 to 178.59 mmHg; P < 0.001), along with greater variance in intrarenal pressure (log transformed) (6.23(1.59) versus 4.60(1.30); 95% c.i. for MD 0.62 to 2.66; P = 0.001). Surgeon satisfaction with procedural vision reported on a scale of 10 was higher with PB compared with HP irrigation (mean(s.d.) 8.75(0.58) versus 6.28(1.27); 95% c.i. for MD 1.79 to 3.16; P < 0.001). Subjective HP usage force did not correlate significantly with transmitted intrarenal pressure (Pearson R = −0.15, P = 0.57). One patient (HP arm) developed urosepsis. Conclusion: Manual HP irrigation resulted in higher and more fluctuant intrarenal pressure trace (with inferior visual clarity) than 100-mmHg PB irrigation. Registration number: osf.io/jmg2h (https://osf.io/).
- Open Access
- 1 March 2024
- Published by Springer Nature in Journal of Robotic Surgery
- Vol. 18 (1) , 1-4
Design and utilisation of a novel, high-fidelity, low-cost, hybrid-tissue simulation model to facilitate training in robot-assisted partial nephrectomy
Robot-assisted partial nephrectomy (RAPN) has rapidly evolved as the standard of care for appropriately selected renal tumours, offering key patient benefits over radical nephrectomy or open surgical approaches. Accordingly, RAPN is a key competency that urology trainees wishing to treat kidney cancer must master. Training in robotic surgery is subject to numerous challenges, and simulation has been established as valuable step in the robotic learning curve. However, simulation models are often both expensive and suboptimal in fidelity. This means that the number of practice repetitions for a trainee may limited by cost restraints, and that trainees may struggle to reconcile the skills obtained in the simulation laboratory with real-world practice in the operating room. We have developed a high-fidelity, low-cost, customizable model for RAPN simulation based on porcine tissue. The model has been utilised in teaching courses at our institution, confirming both feasibility of use and high user acceptability. We share the design of our model in this proof-of-concept report.
- 1 March 2024
- Published by Springer Nature in Journal of Robotic Surgery
- Vol. 18 (1) , 1-4
Open AccessDesign and utilisation of a novel, high-fidelity, low-cost, hybrid-tissue simulation model to facilitate training in robot-assisted partial nephrectomy
Robot-assisted partial nephrectomy (RAPN) has rapidly evolved as the standard of care for appropriately selected renal tumours, offering key patient benefits over radical nephrectomy or open surgical approaches. Accordingly, RAPN is a key competency that urology trainees wishing to treat kidney cancer must master. Training in robotic surgery is subject to numerous challenges, and simulation has been established as valuable step in the robotic learning curve. However, simulation models are often both expensive and suboptimal in fidelity. This means that the number of practice repetitions for a trainee may limited by cost restraints, and that trainees may struggle to reconcile the skills obtained in the simulation laboratory with real-world practice in the operating room. We have developed a high-fidelity, low-cost, customizable model for RAPN simulation based on porcine tissue. The model has been utilised in teaching courses at our institution, confirming both feasibility of use and high user acceptability. We share the design of our model in this proof-of-concept report.
- 1 November 2023
- Published by SAGE Publications in Journal of Endourology
- Vol. 37 (11) , 1191-1199
Perceptions and Practice Patterns of Urologists Relating to Intrarenal Pressure During Ureteroscopy: Findings from a Global Cross-Sectional Analysis
Objectives: To explore beliefs and practice patterns of urologists regarding intrarenal pressure (IRP) during ureteroscopy (URS). Methods: A customized questionnaire was designed in a 4-step iterative process incorporating a systematic review of the literature and critical analysis of topics/questions by six endourologists. The 19-item questionnaire interrogated perceptions, practice patterns, and key areas of uncertainty regarding ureteroscopic IRP, and was disseminated via urologic societies, networks, and social media to the international urologic community. Consultants/attendings and trainees currently practicing urology were eligible to respond. Quantitative responses were compiled and analyzed using descriptive statistics and chi-square test, with subgroup analysis by procedure volume. Results: Responses were received from 522 urologists, practicing in six continents. The individual question response rate was >97%. Most (83.9%, 437/515) respondents were practicing at a consultant/attending level. An endourology fellowship incorporating stone management had been completed by 59.2% (307/519). The vast majority of respondents (85.4%, 446/520) scored the perceived clinical significance of IRP during URS ≥7/10 on a Likert scale. Concern was uniformly reported, with no difference between respondents with and without a high annual case volume ( p = 0.16). Potential adverse outcomes respondents associated with elevated ureteroscopic IRP were urosepsis (96.2%, 501/520), collecting system rupture (80.8%, 421/520), postoperative pain (67%, 349/520), bleeding (63.72%, 332/520), and long-term renal damage (26.1%, 136/520). Almost all participants (96.2%, 501/520) used measures aiming to reduce IRP during URS. Regarding the perceived maximum acceptable threshold for mean IRP during URS, 30 mm Hg (40 cm H 2 O) was most frequently selected [23.2% (119/463)], with most participants (78.2%, 341/463) choosing a value ≤40 mm Hg. Conclusions: This is the first large-scale analysis of urologists' perceptions of ureteroscopic IRP. It identifies high levels of concern among the global urologic community, with almost unanimous agreement that elevated IRP is associated with adverse clinical outcomes. Equipoise remains regarding appropriate IRP limits intraoperatively and the most appropriate technical strategies to ensure adherence to these.
- 1 November 2023
- Published by SAGE Publications in Journal of Endourology
- Vol. 37 (11) , 1191-1199
Perceptions and Practice Patterns of Urologists Relating to Intrarenal Pressure During Ureteroscopy: Findings from a Global Cross-Sectional Analysis
Objectives: To explore beliefs and practice patterns of urologists regarding intrarenal pressure (IRP) during ureteroscopy (URS). Methods: A customized questionnaire was designed in a 4-step iterative process incorporating a systematic review of the literature and critical analysis of topics/questions by six endourologists. The 19-item questionnaire interrogated perceptions, practice patterns, and key areas of uncertainty regarding ureteroscopic IRP, and was disseminated via urologic societies, networks, and social media to the international urologic community. Consultants/attendings and trainees currently practicing urology were eligible to respond. Quantitative responses were compiled and analyzed using descriptive statistics and chi-square test, with subgroup analysis by procedure volume. Results: Responses were received from 522 urologists, practicing in six continents. The individual question response rate was >97%. Most (83.9%, 437/515) respondents were practicing at a consultant/attending level. An endourology fellowship incorporating stone management had been completed by 59.2% (307/519). The vast majority of respondents (85.4%, 446/520) scored the perceived clinical significance of IRP during URS ≥7/10 on a Likert scale. Concern was uniformly reported, with no difference between respondents with and without a high annual case volume ( p = 0.16). Potential adverse outcomes respondents associated with elevated ureteroscopic IRP were urosepsis (96.2%, 501/520), collecting system rupture (80.8%, 421/520), postoperative pain (67%, 349/520), bleeding (63.72%, 332/520), and long-term renal damage (26.1%, 136/520). Almost all participants (96.2%, 501/520) used measures aiming to reduce IRP during URS. Regarding the perceived maximum acceptable threshold for mean IRP during URS, 30 mm Hg (40 cm H 2 O) was most frequently selected [23.2% (119/463)], with most participants (78.2%, 341/463) choosing a value ≤40 mm Hg. Conclusions: This is the first large-scale analysis of urologists' perceptions of ureteroscopic IRP. It identifies high levels of concern among the global urologic community, with almost unanimous agreement that elevated IRP is associated with adverse clinical outcomes. Equipoise remains regarding appropriate IRP limits intraoperatively and the most appropriate technical strategies to ensure adherence to these.
- Open Access
- 17 September 2023
- Published by Elsevier in European Urology Open Science
- Vol. 55, S6
Male Genital Reconstruction - A single surgeon experience
- 17 September 2023
- Published by Elsevier in European Urology Open Science
- Vol. 55, S6
Open AccessMale Genital Reconstruction - A single surgeon experience