Marc P. van der Schroeff
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Marc P. van der Schroeff has a total of 113 co-authors. Here are the top co-authors by number of shared publications:
- Jantien L. Vroegop
Department of Otorhinolaryngology and Head and Neck Surgery, Erasmus Medical Centre, Rotterdam, The Netherlands
3 shared publications - André Goedegebure
Department of Otorhinolaryngology, Head and Neck Surgery, Erasmus Medical Center
2 shared publications - Alessandro Gialluisi
Research Unit of Epidemiology and Prevention, IRCCS NEUROMED, Pozzilli, Italy
1 shared publication Anders D. Børglum
Department of Biomedicine, Aarhus University, 8000 Aarhus, Denmark
1 shared publicationAndrea G. Allegrini
Social, Genetic and Developmental Psychiatry Centre, Institute of Psychiatry, Psychology and Neuroscience, King’s College London, London SE5 8AF, United Kingdom
1 shared publicationAndrew J. O. Whitehouse
Telethon Kids Institute, The University of Western Australia, Perth, WA 6009, Australia
1 shared publication
Latest Publications
- 8 January 2026
- Published by American Speech Language Hearing Association in Journal of Speech, Language, and Hearing Research
- Vol. 69 (1) , 362-376
Factors Associated With Hearing-Related Quality of Life in Children and Adolescents With Hearing Loss
Objective: As the impact of hearing loss extends beyond auditory function, patient-reported outcome measures (PROMs) measuring quality of life (QOL) are increasingly incorporated in the management and follow-up of children with hearing loss. The Hearing Environments and Reflection on Quality of Life (HEAR-QL) is a hearing-specific QOL tool, providing insight into the impact of hearing loss on daily life. This study aims to identify factors associated with hearing-related QOL in children and adolescents with hearing loss. Method: Clinical data of 136 subjects (84 children and 52 adolescents) aged 7–18 years with unilateral and bilateral hearing loss, attending our audiology outpatient clinic at the Erasmus MC Sophia Children's Hospital in Rotterdam, the Netherlands, were used. The Dutch HEAR-QL questionnaires for children and adolescents were used to assess hearing-related QOL. Characteristics of hearing rehabilitation; hearing status; and the demographic factors gender, age, and education type were explored as potential factors associated with hearing-related QOL, using group comparisons, Spearman's correlation coefficient, and multiple linear regression analysis. Results: Univariate analysis showed that children in regular education scored significantly higher on hearing-specific QOL for the Activities subscale compared to those attending education for the deaf and hard of hearing. Adolescents with hearing aids had higher HEAR-QL scores compared to those with cochlear implants. Furthermore, speech recognition in both quiet and noise was significantly associated with hearing-related QOL in the adolescent age group. Multiple linear regression analysis confirmed higher QOL in adolescents with hearing aids and identified speech recognition in quiet at 45 dB SPL as a significant predictor of hearing-related QOL in adolescents. In children, univariate analyses revealed no significant associations with hearing device characteristics or auditory performance. Conclusions: The main finding of this study was that the type of hearing device and aided speech recognition scores were associated with hearing-specific QOL in adolescents, illustrating the vital contribution of hearing rehabilitation to daily life functioning. The increasing use of QOL PROMs in children and adolescents with hearing loss will facilitate further exploration of potential associated factors and could increase our insight into this vulnerable population group. Supplemental Material: https://doi.org/10.23641/asha.30795119
- 8 January 2026
- Published by American Speech Language Hearing Association in Journal of Speech, Language, and Hearing Research
- Vol. 69 (1) , 362-376
Factors Associated With Hearing-Related Quality of Life in Children and Adolescents With Hearing Loss
Objective: As the impact of hearing loss extends beyond auditory function, patient-reported outcome measures (PROMs) measuring quality of life (QOL) are increasingly incorporated in the management and follow-up of children with hearing loss. The Hearing Environments and Reflection on Quality of Life (HEAR-QL) is a hearing-specific QOL tool, providing insight into the impact of hearing loss on daily life. This study aims to identify factors associated with hearing-related QOL in children and adolescents with hearing loss. Method: Clinical data of 136 subjects (84 children and 52 adolescents) aged 7–18 years with unilateral and bilateral hearing loss, attending our audiology outpatient clinic at the Erasmus MC Sophia Children's Hospital in Rotterdam, the Netherlands, were used. The Dutch HEAR-QL questionnaires for children and adolescents were used to assess hearing-related QOL. Characteristics of hearing rehabilitation; hearing status; and the demographic factors gender, age, and education type were explored as potential factors associated with hearing-related QOL, using group comparisons, Spearman's correlation coefficient, and multiple linear regression analysis. Results: Univariate analysis showed that children in regular education scored significantly higher on hearing-specific QOL for the Activities subscale compared to those attending education for the deaf and hard of hearing. Adolescents with hearing aids had higher HEAR-QL scores compared to those with cochlear implants. Furthermore, speech recognition in both quiet and noise was significantly associated with hearing-related QOL in the adolescent age group. Multiple linear regression analysis confirmed higher QOL in adolescents with hearing aids and identified speech recognition in quiet at 45 dB SPL as a significant predictor of hearing-related QOL in adolescents. In children, univariate analyses revealed no significant associations with hearing device characteristics or auditory performance. Conclusions: The main finding of this study was that the type of hearing device and aided speech recognition scores were associated with hearing-specific QOL in adolescents, illustrating the vital contribution of hearing rehabilitation to daily life functioning. The increasing use of QOL PROMs in children and adolescents with hearing loss will facilitate further exploration of potential associated factors and could increase our insight into this vulnerable population group. Supplemental Material: https://doi.org/10.23641/asha.30795119
- Top Cited PapersOpen Access
- 23 August 2022
- Published by National Academy of Sciences in Proceedings of the National Academy of Sciences of the United States of America
- Vol. 119 (35)
Genome-wide analyses of individual differences in quantitatively assessed reading- and language-related skills in up to 34,000 people
The use of spoken and written language is a fundamental human capacity. Individual differences in reading- and language-related skills are influenced by genetic variation, with twin-based heritability estimates of 30 to 80% depending on the trait. The genetic architecture is complex, heterogeneous, and multifactorial, but investigations of contributions of single-nucleotide polymorphisms (SNPs) were thus far underpowered. We present a multicohort genome-wide association study (GWAS) of five traits assessed individually using psychometric measures (word reading, nonword reading, spelling, phoneme awareness, and nonword repetition) in samples of 13,633 to 33,959 participants aged 5 to 26 y. We identified genome-wide significant association with word reading (rs11208009,P= 1.098 × 10−8) at a locus that has not been associated with intelligence or educational attainment. All five reading-/language-related traits showed robust SNP heritability, accounting for 13 to 26% of trait variability. Genomic structural equation modeling revealed a shared genetic factor explaining most of the variation in word/nonword reading, spelling, and phoneme awareness, which only partially overlapped with genetic variation contributing to nonword repetition, intelligence, and educational attainment. A multivariate GWAS of word/nonword reading, spelling, and phoneme awareness maximized power for follow-up investigation. Genetic correlation analysis with neuroimaging traits identified an association with the surface area of the banks of the left superior temporal sulcus, a brain region linked to the processing of spoken and written language. Heritability was enriched for genomic elements regulating gene expression in the fetal brain and in chromosomal regions that are depleted of Neanderthal variants. Together, these results provide avenues for deciphering the biological underpinnings of uniquely human traits.
- 23 August 2022
- Published by National Academy of Sciences in Proceedings of the National Academy of Sciences of the United States of America
- Vol. 119 (35)
Top Cited PapersOpen AccessGenome-wide analyses of individual differences in quantitatively assessed reading- and language-related skills in up to 34,000 people
The use of spoken and written language is a fundamental human capacity. Individual differences in reading- and language-related skills are influenced by genetic variation, with twin-based heritability estimates of 30 to 80% depending on the trait. The genetic architecture is complex, heterogeneous, and multifactorial, but investigations of contributions of single-nucleotide polymorphisms (SNPs) were thus far underpowered. We present a multicohort genome-wide association study (GWAS) of five traits assessed individually using psychometric measures (word reading, nonword reading, spelling, phoneme awareness, and nonword repetition) in samples of 13,633 to 33,959 participants aged 5 to 26 y. We identified genome-wide significant association with word reading (rs11208009,P= 1.098 × 10−8) at a locus that has not been associated with intelligence or educational attainment. All five reading-/language-related traits showed robust SNP heritability, accounting for 13 to 26% of trait variability. Genomic structural equation modeling revealed a shared genetic factor explaining most of the variation in word/nonword reading, spelling, and phoneme awareness, which only partially overlapped with genetic variation contributing to nonword repetition, intelligence, and educational attainment. A multivariate GWAS of word/nonword reading, spelling, and phoneme awareness maximized power for follow-up investigation. Genetic correlation analysis with neuroimaging traits identified an association with the surface area of the banks of the left superior temporal sulcus, a brain region linked to the processing of spoken and written language. Heritability was enriched for genomic elements regulating gene expression in the fetal brain and in chromosomal regions that are depleted of Neanderthal variants. Together, these results provide avenues for deciphering the biological underpinnings of uniquely human traits.
- 1 November 2018
- Published by Wolters Kluwer Health in Ear & Hearing
- Vol. 39 (6) , 1039-1045
How to Optimally Fit a Hearing Aid for Bimodal Cochlear Implant Users: A Systematic Review
Objectives: Bimodal hearing has shown to improve speech recognition in quiet and in noise and to improve sound localization compared with unilateral cochlear implant (CI) use alone. Fitting the CI and hearing aid (HA) separately has been described well, but HA fitting procedures for bimodal CI users are not well researched or widely accepted. The aim of the present study was to systematically review the literature on the effect of different HA fitting strategies on auditory performance in bimodal CI users. Design: Original articles, written in English, were identified through systematic searches in Medline (OvidSP), Embase, Web of Science, Scopus, CINAHL, Cochrane, PubMed publisher, and Google Scholar. The quality of the studies was assessed on five aspects: methodologic quality (with the methodological index for nonrandomized studies score), number of subjects, quality of the description of contralateral hearing loss, quality of HA verification, and direct comparison of HA fitting procedures based on auditory performance. Results: A total of 1665 records were retrieved, of which 17 were included for systematical reviews. Critical appraisal led to three high-quality studies, 10 medium-quality studies, and four low-quality studies. The results of the studies were structured according to four topics: frequency response, frequency translation/transposition, dynamic range compression, and loudness. In general, a bimodal benefit was found in most studies, using various strategies for the HA fitting. Using a standard prescription rule such as National Acoustics Laboratory formula-non-linear 1, National Acoustics Laboratory formula-non-linear 2, or desired sensation level is a good starting point in children and adults. Conclusions: Although a bimodal benefit was found in most studies, there is no clear evidence how certain choices in HA fitting contribute to optimal bimodal performance. A generally accepted HA prescription rule is an essential part of most fitting procedures used in the studies. Current evidence suggests that frequency lowering or transposition is not beneficial. Individual fine tuning based on loudness or general preference is often applied, but its additional value for auditory performance should be investigated more thoroughly. Good quality comparative studies are needed to further develop evidence-based fitting procedures in case of bimodal listening.
- 1 November 2018
- Published by Wolters Kluwer Health in Ear & Hearing
- Vol. 39 (6) , 1039-1045
How to Optimally Fit a Hearing Aid for Bimodal Cochlear Implant Users: A Systematic Review
Objectives: Bimodal hearing has shown to improve speech recognition in quiet and in noise and to improve sound localization compared with unilateral cochlear implant (CI) use alone. Fitting the CI and hearing aid (HA) separately has been described well, but HA fitting procedures for bimodal CI users are not well researched or widely accepted. The aim of the present study was to systematically review the literature on the effect of different HA fitting strategies on auditory performance in bimodal CI users. Design: Original articles, written in English, were identified through systematic searches in Medline (OvidSP), Embase, Web of Science, Scopus, CINAHL, Cochrane, PubMed publisher, and Google Scholar. The quality of the studies was assessed on five aspects: methodologic quality (with the methodological index for nonrandomized studies score), number of subjects, quality of the description of contralateral hearing loss, quality of HA verification, and direct comparison of HA fitting procedures based on auditory performance. Results: A total of 1665 records were retrieved, of which 17 were included for systematical reviews. Critical appraisal led to three high-quality studies, 10 medium-quality studies, and four low-quality studies. The results of the studies were structured according to four topics: frequency response, frequency translation/transposition, dynamic range compression, and loudness. In general, a bimodal benefit was found in most studies, using various strategies for the HA fitting. Using a standard prescription rule such as National Acoustics Laboratory formula-non-linear 1, National Acoustics Laboratory formula-non-linear 2, or desired sensation level is a good starting point in children and adults. Conclusions: Although a bimodal benefit was found in most studies, there is no clear evidence how certain choices in HA fitting contribute to optimal bimodal performance. A generally accepted HA prescription rule is an essential part of most fitting procedures used in the studies. Current evidence suggests that frequency lowering or transposition is not beneficial. Individual fine tuning based on loudness or general preference is often applied, but its additional value for auditory performance should be investigated more thoroughly. Good quality comparative studies are needed to further develop evidence-based fitting procedures in case of bimodal listening.
- Open Access
- 11 September 2017
- Published by JMIR Publications Inc. in JMIR Research Protocols
- Vol. 6 (9) , e174
Development of a Virtual Reality Exposure Tool as Psychological Preparation for Elective Pediatric Day Care Surgery: Methodological Approach for a Randomized Controlled Trial
Preoperative anxiety in children is highly prevalent and is associated with adverse outcomes. Existing psychosocial interventions to reduce preoperative anxiety are often aimed at distraction and are of limited efficacy. Gradual exposure is a far more effective way to reduce anxiety. Virtual reality (VR) provides a unique opportunity to gradually expose children to all aspects of the operating theater. The aims of our study are (1) to develop a virtual reality exposure (VRE) tool to prepare children psychologically for surgery; and (2) to examine the efficacy of the VRE tool in a randomized controlled trial (RCT), in which VRE will be compared to care as usual (CAU). The VRE tool is highly realistic and resembles the operating room environment accurately. With this tool, children will not only be able to explore the operating room environment, but also get accustomed to general anesthesia procedures. The PREoperative Virtual reality Intervention to Enhance Wellbeing (PREVIEW) study will be conducted. In this single-blinded RCT, 200 consecutive patients (aged 4 to 12 years) undergoing elective day care surgery for dental, oral, or ear-nose-throat problems, will be randomly allocated to the preoperative VRE intervention or CAU. The primary outcome is change in child state anxiety level between baseline and induction of anesthesia. Secondary outcome measures include child's postoperative anxiety, emergence delirium, postoperative pain, use of analgesics, health care use, and pre- and postoperative parental anxiety. The VRE tool has been developed. Participant recruitment began March 2017 and is expected to be completed by September 2018. To our knowledge, this is the first RCT evaluating the effect of a VRE tool to prepare children for surgery. The VRE intervention is expected to significantly diminish preoperative anxiety, postoperative pain, and the use of postoperative analgesics in pediatric patients. The tool could create a less stressful experience for both children and their parents, in line with the modern emphasis on patient- and family-centered care. Netherlands Trial Registry: NTR6116; http://www.trialregister.nl/trialreg/admin/rctview.asp?TC=6116 (Archived by WebCite at http://www.webcitation.org/6ryke7aep).
- 11 September 2017
- Published by JMIR Publications Inc. in JMIR Research Protocols
- Vol. 6 (9) , e174
Open AccessDevelopment of a Virtual Reality Exposure Tool as Psychological Preparation for Elective Pediatric Day Care Surgery: Methodological Approach for a Randomized Controlled Trial
Preoperative anxiety in children is highly prevalent and is associated with adverse outcomes. Existing psychosocial interventions to reduce preoperative anxiety are often aimed at distraction and are of limited efficacy. Gradual exposure is a far more effective way to reduce anxiety. Virtual reality (VR) provides a unique opportunity to gradually expose children to all aspects of the operating theater. The aims of our study are (1) to develop a virtual reality exposure (VRE) tool to prepare children psychologically for surgery; and (2) to examine the efficacy of the VRE tool in a randomized controlled trial (RCT), in which VRE will be compared to care as usual (CAU). The VRE tool is highly realistic and resembles the operating room environment accurately. With this tool, children will not only be able to explore the operating room environment, but also get accustomed to general anesthesia procedures. The PREoperative Virtual reality Intervention to Enhance Wellbeing (PREVIEW) study will be conducted. In this single-blinded RCT, 200 consecutive patients (aged 4 to 12 years) undergoing elective day care surgery for dental, oral, or ear-nose-throat problems, will be randomly allocated to the preoperative VRE intervention or CAU. The primary outcome is change in child state anxiety level between baseline and induction of anesthesia. Secondary outcome measures include child's postoperative anxiety, emergence delirium, postoperative pain, use of analgesics, health care use, and pre- and postoperative parental anxiety. The VRE tool has been developed. Participant recruitment began March 2017 and is expected to be completed by September 2018. To our knowledge, this is the first RCT evaluating the effect of a VRE tool to prepare children for surgery. The VRE intervention is expected to significantly diminish preoperative anxiety, postoperative pain, and the use of postoperative analgesics in pediatric patients. The tool could create a less stressful experience for both children and their parents, in line with the modern emphasis on patient- and family-centered care. Netherlands Trial Registry: NTR6116; http://www.trialregister.nl/trialreg/admin/rctview.asp?TC=6116 (Archived by WebCite at http://www.webcitation.org/6ryke7aep).
- 1 July 2017
- Published by Wolters Kluwer Health in Ear & Hearing
- Vol. 38 (4) , e232-e240
Self-Adjustment of Upper Electrical Stimulation Levels in CI Programming and the Effect on Auditory Functioning
With current cochlear implants (CIs), CI recipients achieve good speech perception in quiet surroundings. However, in acoustically complex, real-life environments, speech comprehension remains difficult and sound quality often remains poor. It is, therefore, a challenge to program CIs for such environments in a clinic. The CI manufacturer Cochlear Ltd. recently introduced a remote control that enables CI recipients to alter the upper stimulation levels of their user programs themselves. In this concept, called remote assistant fitting (RAF), bass and treble controls can be adjusted by applying a tilt to emphasize either the low- or high-frequency C-levels, respectively. This concept of self-programming may be able to overcome limitations associated with fine-tuning the CI sound processor in a clinic. The aim of this study was to investigate to what extent CI recipients already accustomed to their clinically fitted program would adjust the settings in daily life if able to do so. Additionally, we studied the effects of these changes on auditory functioning in terms of speech intelligibility (in quiet and in noise), noise tolerance, and subjectively perceived speech perception and sound quality. Twenty-two experienced adult CI recipients (implant use >12 months) participated in this prospective clinical study, which used a within-subject repeated measures design. All participants had phoneme scores of ≥70% at 65 dB SPL in quiet conditions, and all used a Cochlear Nucleus CP810 sound processor. Auditory performance was tested by a speech-in-quiet test, a speech-in-noise test, an acceptable noise level test, and a questionnaire about perceived auditory functioning, that is, a speech and sound quality (SSQ-C) questionnaire. The first session consisted of a baseline test in which the participants used their own CI program and were instructed on how to use RAF. After the first session, participants used RAF for 3 weeks at home. After these 3 weeks, the participants returned to the clinic for auditory functioning tests with their self-adjusted programs and completed the SSQ-C. Fifteen participants (68%) adjusted their C-level frequency profile by more than 5 clinical levels for at least one electrode. Seven participants preferred a higher contribution of the high frequencies relative to the low frequencies, while five participants preferred more low-frequency stimulation. One-third of the participants adjusted the high and low frequencies equally, while some participants mainly used the overall volume to change their settings. Several parts of the SSQ-C questionnaire scores showed an improvement in perceived auditory functioning after the subjects used RAF. No significant change was found on the auditory functioning tests for speech-in-quiet, speech-in-noise, or acceptable noise level. In conclusion, the majority of experienced CI users made modest changes in the settings of their programs in various ways and were able to do so with the RAF. After altering the programs, the participants experienced an improvement in speech perception in quiet environments and improved perceived sound quality without compromising auditory performance. Therefore, it can be concluded that self-adjustment of CI settings is a useful and clinically applicable tool that may help CI recipients to improve perceived sound quality in their daily lives.
- 1 July 2017
- Published by Wolters Kluwer Health in Ear & Hearing
- Vol. 38 (4) , e232-e240
Self-Adjustment of Upper Electrical Stimulation Levels in CI Programming and the Effect on Auditory Functioning
With current cochlear implants (CIs), CI recipients achieve good speech perception in quiet surroundings. However, in acoustically complex, real-life environments, speech comprehension remains difficult and sound quality often remains poor. It is, therefore, a challenge to program CIs for such environments in a clinic. The CI manufacturer Cochlear Ltd. recently introduced a remote control that enables CI recipients to alter the upper stimulation levels of their user programs themselves. In this concept, called remote assistant fitting (RAF), bass and treble controls can be adjusted by applying a tilt to emphasize either the low- or high-frequency C-levels, respectively. This concept of self-programming may be able to overcome limitations associated with fine-tuning the CI sound processor in a clinic. The aim of this study was to investigate to what extent CI recipients already accustomed to their clinically fitted program would adjust the settings in daily life if able to do so. Additionally, we studied the effects of these changes on auditory functioning in terms of speech intelligibility (in quiet and in noise), noise tolerance, and subjectively perceived speech perception and sound quality. Twenty-two experienced adult CI recipients (implant use >12 months) participated in this prospective clinical study, which used a within-subject repeated measures design. All participants had phoneme scores of ≥70% at 65 dB SPL in quiet conditions, and all used a Cochlear Nucleus CP810 sound processor. Auditory performance was tested by a speech-in-quiet test, a speech-in-noise test, an acceptable noise level test, and a questionnaire about perceived auditory functioning, that is, a speech and sound quality (SSQ-C) questionnaire. The first session consisted of a baseline test in which the participants used their own CI program and were instructed on how to use RAF. After the first session, participants used RAF for 3 weeks at home. After these 3 weeks, the participants returned to the clinic for auditory functioning tests with their self-adjusted programs and completed the SSQ-C. Fifteen participants (68%) adjusted their C-level frequency profile by more than 5 clinical levels for at least one electrode. Seven participants preferred a higher contribution of the high frequencies relative to the low frequencies, while five participants preferred more low-frequency stimulation. One-third of the participants adjusted the high and low frequencies equally, while some participants mainly used the overall volume to change their settings. Several parts of the SSQ-C questionnaire scores showed an improvement in perceived auditory functioning after the subjects used RAF. No significant change was found on the auditory functioning tests for speech-in-quiet, speech-in-noise, or acceptable noise level. In conclusion, the majority of experienced CI users made modest changes in the settings of their programs in various ways and were able to do so with the RAF. After altering the programs, the participants experienced an improvement in speech perception in quiet environments and improved perceived sound quality without compromising auditory performance. Therefore, it can be concluded that self-adjustment of CI settings is a useful and clinically applicable tool that may help CI recipients to improve perceived sound quality in their daily lives.
- 1 March 2016
- Published by SAGE Publications in The Cleft Palate Craniofacial Journal
- Vol. 53 (2) , 203-209
Respiratory Distress following Cleft Palate Repair in Children with Robin Sequence
Objective: The aim of this study is to assess prevalence, severity, and duration of respiratory distress following palatoplasty in children with Robin sequence and to evaluate perioperative management. Design: Retrospective chart review study. Data were collected for patients who were born between 2009 and 2012 and underwent palatoplasty in the Sophia Children's Hospital-Erasmus Medical Center. Result: Of the 75 patients with cleft palate, 30 with Robin sequence and a control group of 45 cleft without Robin sequence underwent palatoplasty. Prior to closure, 26 of 30 patients with Robin sequence had been treated by prone positioning, and four needed additional treatment. The mean age at closure was 12.4 months for patients with Robin sequence and 10.9 months for patients without Robin sequence (P = .05). On the basis of the results of preoperative polysomnography with palatal plate, closure was postponed in two patients with Robin sequence. In the Robin sequence group, eight of the 30 patients developed postoperative respiratory distress within 48 hours and one patient, after 7 days; whereas none within the non—Robin sequence group developed respiratory distress. In all nine cases of Robin sequence the obstructive problems resolved within a few days, with four children requiring a temporary nasopharyngeal tube (NPT). There were no significant differences between preoperative polysomnography results of the nine patients with Robin sequence who developed postoperative respiratory distress compared with those patients with Robin sequence who did not. Conclusion: Despite delayed closure compared with children without Robin sequence, 30% of the children with Robin sequence developed respiratory distress following palatoplasty, which resolved within a few days. This study emphasizes the need for close perioperative monitoring of patients with Robin sequence who undergo palatoplasty.
- 1 March 2016
- Published by SAGE Publications in The Cleft Palate Craniofacial Journal
- Vol. 53 (2) , 203-209
Respiratory Distress following Cleft Palate Repair in Children with Robin Sequence
Objective: The aim of this study is to assess prevalence, severity, and duration of respiratory distress following palatoplasty in children with Robin sequence and to evaluate perioperative management. Design: Retrospective chart review study. Data were collected for patients who were born between 2009 and 2012 and underwent palatoplasty in the Sophia Children's Hospital-Erasmus Medical Center. Result: Of the 75 patients with cleft palate, 30 with Robin sequence and a control group of 45 cleft without Robin sequence underwent palatoplasty. Prior to closure, 26 of 30 patients with Robin sequence had been treated by prone positioning, and four needed additional treatment. The mean age at closure was 12.4 months for patients with Robin sequence and 10.9 months for patients without Robin sequence (P = .05). On the basis of the results of preoperative polysomnography with palatal plate, closure was postponed in two patients with Robin sequence. In the Robin sequence group, eight of the 30 patients developed postoperative respiratory distress within 48 hours and one patient, after 7 days; whereas none within the non—Robin sequence group developed respiratory distress. In all nine cases of Robin sequence the obstructive problems resolved within a few days, with four children requiring a temporary nasopharyngeal tube (NPT). There were no significant differences between preoperative polysomnography results of the nine patients with Robin sequence who developed postoperative respiratory distress compared with those patients with Robin sequence who did not. Conclusion: Despite delayed closure compared with children without Robin sequence, 30% of the children with Robin sequence developed respiratory distress following palatoplasty, which resolved within a few days. This study emphasizes the need for close perioperative monitoring of patients with Robin sequence who undergo palatoplasty.