AYAmeen Hassan Yazdavar

Ameen Hassan Yazdavar

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Ameen Hassan Yazdavar has a total of 10 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Harmonic Analysis of Droop-Based Islanded Microgrids

    by Ameen Hassan Yazdavar, Abdelsalam A. Eajal, Maher A. Azzouz, M. M. A. Salama, Ehab F. El-Saadany

    Islanded microgrids have specific features that should be considered in their harmonic analysis. First, microgrids’ distributed generators (DGs) are typically droop-based, and accordingly, the steady-state frequency is different from the nominal one. This affects the harmonics produced by DGs and nonlinear loads. Second, there is no slack bus, which affects the distribution of the fundamental currents, and thus, the harmonics. Third, DGs usually have voltage source converters (VSCs) as an interface for energy transfer to microgrids. The control structures and output filters of DGs affect the voltage and current distortions, and hence, they should be considered in the harmonic analysis. This paper introduces a sequential algorithm for the harmonic analysis of droop-based islanded microgrids that considers these features. For being accurate and yet computationally efficient, DGs’ cascaded control loops are modeled in the proposed algorithm through their transfer functions. Due to its quadratic convergence, a Newton-based approach is proposed for modeling nonlinear loads that relies on an analytical Jacobian matrix to further speed up its convergence. The meritorious advantage of the proposed approach is the consideration of the mutual coupling between different harmonics. The effectiveness of the proposed algorithm is confirmed through comparative evaluations with time-domain simulations.


  • Optimizing the Droop Characteristics of AC/DC Hybrid Microgrids for Precise Power Sharing

    by Abdelsalam A. Eajal, Ameen Hassan Yazdavar, Ehab F. El-Saadany, Magdy M. A. Salama

    AC/DC hybrid microgrids (HMGs) represent a promising architecture that allows the hosting of a mix of ac/dc energy resources and ac/dc loads. Despite their potential, when islanded, HMGs impose operational challenges among of which are precise and stable power sharing, frequency restoration, and voltage regulation. Imprecise power sharing can result in some distributed generators (DGs) being overloaded, while others being underloaded. This article proposes an optimal-power-flow-based optimal power sharing (OPS) scheme to optimize the droop characteristics of DGs and interlinking converters for global power sharing in a multi-DG HMG regardless of DG location and type. The optimized droop parameters might jeopardize the microgrid stability. Thus, the proposed OPS scheme preserves stable power sharing through stability-constrained optimization of the droop characteristics. In addition to DG overloading because of unequal power sharing, voltage-sensitive loads could possibly suffer from voltage deviations because of drooping the voltage with the load increase. The proposed OPS strategy enjoys the ability to regulate the ac/dc voltage within a desired range and restore the nominal frequency. Steady-state and time-domain simulations verify the effectiveness of the proposed sharing scheme in achieving the underlying objectives. Test results also prove the capability of the OPS scheme in zonal power sharing in the case of a distribution grid with multizone ac/dc microgrids.


  • Optimal Planning of Distributed Generators and Shunt Capacitors in Isolated Microgrids With Nonlinear Loads

    by Ameen Hassan Yazdavar, Mostafa Farouk Shaaban, Ehab Fahmy El-Saadany, Magdy M. A. Salama, Hatem H. Zeineldin

    This paper presents a comprehensive design procedure for isolated microgrids with a high penetration of nonlinear loads. The proposed microgrid planning approach simultaneously determines the sizes, locations and types of distributed generators (DGs) and shunt capacitor banks (CBs). The presence of nonlinear loads along with the capacitors of CBs or DGs' output filters may cause severe voltage distortions. To consider this issue, a harmonic power flow tool tailored for planning applications is developed that takes into account the specific features of isolated microgrids. Given the necessity of supply continuity for isolated microgrids after a contingency, the proposed planning approach takes into consideration the reliability to increase the probability of building successful islands. Unlike previous methods, the proposed approach does not rely merely on supply adequacy, and takes into account the fact that the voltage provision requirement can only be fulfilled through dispatchable DGs. The intermittent natures of loads and renewable DGs are modelled probabilistically. The effectiveness of the proposed planning approach has been validated using the PG&E 69-bus system, and the followings are observed: 1) the significance of applying suitable fundamental-power-flow and harmonic-power-flow algorithms for isolated microgrids, and 2) the possibility of avoiding a severe voltage distortion by utilizing an appropriate planning method and only small increase in the cost.


  • Harmonic Analysis of Three-Phase Diode Bridge Rectifiers Under Unbalanced and Distorted Supply

    by Ameen Hassan Yazdavar, Maher Abdelkhalek Azzouz, Ehab F. El-Saadany

    Developing an effective harmonic power flow tool requires fast and accurate calculations of the harmonics generated by nonlinear elements. This paper presents a time-domain-based method for obtaining all steady-state characteristic and non-characteristic harmonics generated by three-phase diode bridge rectifiers, under unbalanced and distorted supply. The developed model is generic and able to address both continuous- and discontinuous-conduction modes with a single formulation. By introducing a virtual resistance on the rectifier's DC side, the model is extended to accommodate any DC-side filter. Further, a unique analytical Jacobian matrix is developed to guarantee a quadratic convergence for the iterative part of the proposed method. The effectiveness of the proposed method for harmonic analysis is confirmed through a comparative evaluation with time-domain simulations using PSCAD/EMTDC.


  • Communication-Free Current Sharing Control Strategy for DC Microgrids and Its Application for AC/DC Hybrid Microgrids

    by Aram Kirakosyan, Ehab F. El-Saadany, Mohamed Shawky El Moursi, Ameen Hassan Yazdavar, Ahmed Al-Durra

    The load sharing in the DC microgrids is affected by the practical factors such as the cable resistances and changes in the system topology. This paper presents a new control algorithm for the application in the DC microgrids to achieve accurate load distribution between droop controlled converters. An identical steady state voltage feedback is used for all droop controlled converters to ensure accurate current sharing. The information about the common voltage is obtained by means of the proposed communication-less control strategy. The proposed strategy does not require prior information about the grid topology and parameters. Therefore, it is applicable to both single- and multibus microgrids. Furthermore, the proposed algorithm enhances the operation of the Interlinking Converters in the hybrid AC/DC microgrids. A comprehensive nonlinear simulation study is conducted in the Matlab/Simulink environment. The simulation results verify the effectiveness of the proposed communication-less control scheme to enable proper load distribution between droop controlled converters as well as to enhance the load sharing between AC and DC microgrids.Finally, the proposed control approach is verified using an OPAL-RT setup.


  • On the Loadability and Voltage Stability of Islanded AC–DC Hybrid Microgrids During Contingencies

    by Abdelsalam A. Eajal, Ameen Hassan Yazdavar, Ehab F. El-Saadany, Kumaraswamy Ponnambalam

    The future smart grid encompasses ac–dc clusters known as ac–dc microgrids. For reliability and security purposes, each microgrid hosts a mix of synchronous-based and converter-based distributed resources. However, synchronous-based generators, in particular, are characterized by their limited reactive power capabilities because of the limitation of their excitation systems, which could lead to voltage instability problems when the hosting microgrid is islanded. AC–DC microgrids also comprise controllable thermal and electrical loads. Most modern ac–dc loads have power electronics interfaces that control the voltage at their ends, exhibiting constant power characteristics. AC–DC microgrids with high penetrations of constant power ac–dc loads are vulnerable to voltage collapse. As with other power system architectures, microgrids are subject to contingencies, e.g., a line circuit outage, during which their loadability can be jeopardized. For this reason, the work reported in this paper involved the investigation of the steady-state voltage stability of islanded ac–dc hybrid microgrids (HMGs) during contingencies. Voltage stability analysis was carried out on a 12-bus ac–dc HMG. Several case studies were designed to reveal the likelihood of voltage instability/collapse in microgrids under severe contingencies. The voltage stability analysis also shows that interfacing ac and dc microgrids does not always enhance loadability. The analysis was carried with the goal of raising awareness among microgrid planners and operators of the possibility that a voltage collapse phenomenon can develop in islanded ac–dc microgrids under extreme events. Contingency analysis should therefore be incorporated into planning and operations criteria for islanded ac–dc microgrids.


  • On the Existence of Voltage Collapse in Islanded Microgrid

    by A. A. Eajal, Ameen H. Yazdavar, E. F. El-Saadany, K. Ponnambalam

    The future smart grid entails clusters with plug-and-play features known as microgrids. Each microgrid hosts a mix of distributed energy resources including synchronous-based. Nevertheless, synchronous-based generators, are characterised by their limited reactive power capabilities which could lead to voltage collapse problem during islanding. Microgrids also comprises controllable loads. The majority of modern loads are power-electronic-interfaced and demand voltage regulation at their ends, exhibiting constant power characteristics. Microgrids with high penetrations of constant-power loads are vulnerable to voltage collapse especially during contingencies such as weather-caused outages. To this end, this paper investigates the possibility voltage collapse phenomenon in islanded microgrids during contingencies. The voltage stability analysis was carried out on an islanded 6- bus microgrid. Several case studies were designed in order to reveal the likelihood of voltage collapse in microgrids under extreme events.


  • A Novel Decentralized Control Scheme for Enhanced Nonlinear Load Sharing and Power Quality in Islanded Microgrids

    by Ameen Hassan Yazdavar, Maher Abdelkhalek Azzouz, Ehab F. El-Saadany

    The sharing of nonlinear loads among different distributed generation units (DGs) is always a trade-off between accuracy and voltage quality. This paper proposes a virtual harmonic conductance for each harmonic as a family of droop characteristics in terms of conductance versus current. Assigning a variable conductance for each harmonic current improves the DG controllability, thus offering accurate nonlinear load sharing, which is crucial at the near-rated loading, and enhanced voltage quality. The paper also unveils a tuning methodology for the droop characteristics that sets a maximum permissible value for each individual harmonic to comply with international standards. Lastly, a hybrid voltage and current control system is suggested to accurately track the DG harmonic conductance designated by the proposed droop characteristics. While the proposed algorithm is capable of accurately distributing common nonlinear loads among DGs, it also enjoys the advantage of supplying local nonlinear loads by their dedicated DGs. A comprehensive performance evaluation assures the effectiveness of the proposed control strategy.