CWChrys Wesdemiotis

Chrys Wesdemiotis

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Chrys Wesdemiotis has a total of 375 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Functionality, Molecular Weight, and Architectural Analysis of Water-Soluble Polymers by Multidimensional Mass Spectrometry

    by Calum Bochenek, Luciana Rivera Molina, Jack Edwards, Zhibo Liu, Christina Jasieczek Mastromatteo, Chrys Wesdemiotis

    Poly(ethylene glycol) (PEG) is an industrial polymer, employed widely in biomedical, pharmaceutical, and materials applications due to its biocompatibility, water solubility, and stability. However, its end group and architectural diversity and susceptibility to oxidative and environmental degradation complicate precise molecular characterization. This study employed a multidimensional mass spectrometric approach, combining matrix-assisted laser desorption/ionization (MALDI) and electrospray ionization (ESI) with high-resolution mass spectrometry (MS), trapped ion mobility (IM) separation, and tandem mass spectrometry (MS/MS) fragmentation for the comprehensive compositional, structural, and architectural analysis of a degraded sample of methoxy poly(ethylene glycol) methacrylate (mPEG-methacrylate), a hydrophilic polymer used for the preparation of hydrogels and antifouling surfaces. MALDI-MS provided molecular-level resolution of the major degradation products, which included a small amount of surviving mPEG-methacrylate and significant quantities of new products, generated by modification or oligomerization of the methacrylate functionality. Comb-shaped copolymers with double bond and/or oxidized polymethacrylate chain ends were the predominant degradants. ESI-IM-MS added a rapid gas-phase separation dimension, resolving PEG chains according to both charge state and molecular shape and rendering ion mobilities (collision cross-sections) indicative of the architectural diversity produced during degradation. Products invisible by MALDI-MS could be identified, inter alia, as mPEG from ester hydrolysis and poly(mPEG-methacrylate)s with high degrees of polymerization. Charge-dependent mobility trends confirmed variations in polymer compactness depending on the number of PEG side chains, while MS/MS analysis validated the formation of comb architectures and revealed remarkable robustness for methoxy-capped polyether chains. This multidimensional MS strategy offers an advanced framework for the detailed structural elucidation of complex materials and formulations, capturing both the intact polymeric architecture and degradation-derived chemical diversity reflecting the sample’s age and usage. The integration of MALDI-MS and ESI-IM-MS enables simultaneous analysis of molecular weight, primary structure, architecture, and functional heterogeneity, thus providing critical insights into the synthesis, stability, and reactivity of industrial polymers.

  • Characterization of Cross-Linked Elastomer Networks by Thermal Desorption/Pyrolysis Direct Analysis in Real-Time Mass Spectrometry (TDPy-DART-MS)

    by Calum Bochenek, Chrys Wesdemiotis

    Tires are complex polymeric materials composed of rubber elastomers (both natural and synthetic), fillers, steel wire, textiles, and a range of antioxidant and curing systems. These constituents are distributed differently among the various tire parts, which are classified based on their function and proximity to the rim. This study presents a rapid and sensitive approach for the characterization of tire components using mild thermal desorption/pyrolysis (TDPy) coupled to direct analysis in real-time mass spectrometry (DART-MS). This ambient technique was applied to five important tire parts: the tread, sidewall, inner liner, body plies, and bead chafer, to identify structural similarities and differences among their constituents through combined DART-MS and TDPy-DART-MS analysis, tandem mass spectrometry (MS/MS) fragmentation, and size/shape assessment via trapped ion mobility (IM) spectrometry of select ions produced in the DART source. The DART ion source was maintained at 300 °C, while the TDPy temperature was gradually raised from ambient to 600 °C. At low TDPy temperatures (100-250 °C), phthalate plasticizers such as hexadecyl octyl oxalate gave rise to the most abundant ions. At medium and high temperatures (250-550 °C), the dominant ions arose from the phenylenediamine antiozonants C-PPD and 6-PPD, as well as important additives and processing aides crucial to the tire's health and longevity such as antioxidants, dispersants, vulcanization accelerators, lubricants, sealants, and cross-linking agents. For identification of the tire backbone polymer, experiments were run at the highest TDPy temperature possible (550-600 °C) to promote thermal degradation of the cross-linked rubber network; all parts of the tire generated styrene butadiene oligomers except for the inner liner, where poly(isobutylene) chains were the dominant product.


  • Open Access

    Structural and Quantitative Analysis of Polyfluoroalkyl Substances (PFASs) and Para-Phenylenediamines (PPDs) by Direct Analysis in Real Time Ion Mobility Mass Spectrometry (DART-IM-MS)

    by Calum Bochenek, Jack Edwards, Zhibo Liu, Chrys Wesdemiotis

    Polyfluoroalkyl substances (PFASs) and para-phenylenediamines (PPDs) are emerging classes of anthropogenic contaminants that are environmentally persistent (most often found in ground and surface water sources), bioaccumulative, and harmful to human health. These chemicals are currently regulated in the US by the Environmental Protection Agency (EPA), the Food and Drug Administration (FDA), and the Occupational Safety and Health Administration (OSHA). Analysis of these contaminants is currently spearheaded by mass spectrometry (MS) coupled to liquid chromatography (LC) because of their high sensitivity and separation capabilities. Although effective, a major flaw in LC-MS analysis is its large consumption of solvents and the amount of time required for each experiment. Direct analysis in real time mass spectrometry (DART-MS) is a new technique that offers high sensitivity and permits rapid analysis with little to no sample preparation. Herein, we present the qualitative and quantitative analysis of PFASs and PPDs by high-resolution DART-MS, interfaced with ion mobility (IM) and tandem mass spectrometry (MS/MS) characterization, demonstrating the utility of this multidimensional approach for the fast separation and detection of environmental contaminants.


  • Open Access

    Structural and Quantitative Analysis of Polyfluoroalkyl Substances (PFASs) and Para-Phenylenediamines (PPDs) by Direct Analysis in Real Time Ion Mobility Mass Spectrometry (DART-IM-MS)

    by Chrys Wesdemiotis, Calum Bochenek, Jack Edwards, Zhibo Liu

    Poly-fluoroalkyl substances (PFAS) and para-phenylenediamines (PPDs) are emerging classes of anthropogenic contaminants that are environmentally persistent (most often found in ground and surface water sources), bioaccumulative, and harmful to human health. These chemicals are currently regulated in the US by the Environmental Protection Agency (EPA), the Food and Drug Administration (FDA), and the Occupational Safety and Health Administration (OSHA). Analysis of these contaminants is currently spearheaded by mass spectrometry (MS) coupled to liquid chromatography (LC) because of their high sensitivity and separation capabilities, respectively. Although effective, a major flaw in LC-MS analysis is its large consumption of solvents and the amount of time required for each experiment. Direct analysis in real time mass spectrometry (DART- MS) is a new technique that offers high sensitivity and permits rapid analysis with little to no sample preparation. Herein, we present the qualitative and quantitative analysis of PFASs and PPDs by high- resolution DART-MS, interfaced with ion mobility (IM) and tandem mass spectrometry (MS/MS) characterization, demonstrating the utility of this multidimensional approach for the fast separation and detection of environmental contaminants.

  • Inspired by Chemistry Through Research, Teaching, and Life

    by Chrys Wesdemiotis

    A short biography focusing on educational activities and professional career.

  • Open Access

    Synthesis and Characterization of Poly(ethylene furanoate)/Poly(ε-caprolactone) Block Copolymers

    by Johan Stanley, Lidia Molina-Millán, Chrys Wesdemiotis, Ron M. A. Heeren, Alexandra Zamboulis, Lidija Fras Zemljič, Dimitra A. Lambropoulou, Dimitrios N. Bikiaris

    Biobased poly(ethylene furanoate) (PEF)/poly(epsilon-caprolactone) (PCL) block copolymers have been synthesized using ring opening polymerization (ROP) of epsilon-caprolactone (epsilon-CL) in the presence of PEF in different mass ratios. An increase in intrinsic viscosity is observed for the block copolymers with higher epsilon-CL content due to the extension of their macromolecular chain. Matrix-assisted laser desorption ionization time-of-flight mass spectrometry (MS) was employed to understand the composition and structure of the produced block copolymers. The MS analysis helped to confirm the formation of PEF-PCL copolymers in all cases. Furthermore, tandem mass spectrometry experiments were performed to analyze the intrinsic fragmentation mechanism of neat PEF and PCL (both linear and cyclic) and confirm the block structure and end-groups. Finally, nuclear magnetic resonance results confirmed the composition and microstructure of the block copolymers. The synthesized PEF-PCL block copolymers can be used as a replacement for petroleum derived plastics, especially in the field of food packaging.


  • Open Access

    Tandem Mass Spectrometry Reflects Architectural Differences in Analogous, Bis-MPA-Based Linear Polymers, Hyperbranched Polymers, and Dendrimers

    by Kayla Williams-Pavlantos, McKenna J. Redding, Oluwapelumi O. Kareem, Mark A. Arnould, Scott M. Grayson, Chrys Wesdemiotis

    The growing use of branched polymers in various industrial and technological applications has prompted significant interest in understanding their properties, for which accurate structure determination is vital. This work is the first instance where the macromolecular structures of dendrimers, linear polymers, and hyperbranched polymers with analogous 2,2-bis(hydroxymethyl)propionic acid (bis-MPA) backbone groups were synthesized and analyzed via tandem mass spectrometry (MS/MS). When comparing the fragmentation pathways of these polymers, some unique and interesting patterns emerge that provide insight into the primary structures and architectures of each of these materials. As expected, the linear polymer undergoes multiple random backbone cleavages resulting in several fragment ion distributions that vary in size and end group composition. The hyperbranched polymer dissociates preferentially at branching sites; however, differently branched isomers exist for each oligomer size, thus giving rise again to several fragment distributions. In contrast, the dendrimer presents a unique fragmentation pattern comprising key fragment ions of high molecular weight; this unique characteristic stands out as a signature for identifying dendrimer structures. Overall, dendrimers, hyperbranched polymers, and linear polymers display individualized fragmentation behaviors, which are caused by differences in primary structure. As a result, tandem mass spectrometry fragmentation is a particularly useful analytical tool for distinguishing such macromolecular architectures.