Zoraida Solaiga Gaurisankar
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Zoraida Solaiga Gaurisankar has a total of 14 co-authors. Here are the top co-authors by number of shared publications:
- Gwyneth A. van Rijn
Department of Ophthalmology, Leiden University Medical Center, Leiden, The Netherlands
5 shared publications - Jan‐Willem Maria Beenakker
Department of Radiation Oncology, Leiden University Medical Center, Leiden, The Netherlands
5 shared publications - Gregorius P. M. Luyten
Department of Ophthalmology, Leiden University Medical Center, Leiden, The Netherlands
4 shared publications Geert W. Haasnoot
Department of Immunohematology and Blood Transfusion Leiden University Medical Center Leiden The Netherlands
3 shared publicationsAntonio P. Ilgenfritz
Affiliation of authorsDepartment of Ophthalmology, Leiden University Medical Center, Leiden, the Netherlands
2 shared publicationsJosé Eduardo E. Lima
Affiliation of authorsDepartment of Ophthalmology, Leiden University Medical Center, Leiden, the Netherlands
2 shared publications
Latest Publications
- Open Access
- 16 October 2021
- Published by Springer Nature in Graefe's Archive for Clinical and Experimental Ophthalmology
- Vol. 260 (4) , 1367-1375
Two-year results after combined phacoemulsification and iris-fixated phakic intraocular lens removal
Purpose: To describe and present results after a technique for cataract surgery combined with explantation of an iris-fixated phakic intraocular lens (IF-pIOL). Methods: The medical records of all patients, who had undergone cataract surgery combined with IF-pIOL explantation and subsequent implantation of a posterior chamber IOL by the Single Incision Technique (SIT), were reviewed. Data collection included preoperative and postoperative corrected distance visual acuity (CDVA), manifest refraction, and endothelial cell density (ECD) up to a follow-up time of 24 months. Results: Fifty myopic eyes (34 patients) and 9 hyperopic eyes (6 patients) had undergone a SIT procedure mainly because of cataract (67%). Postoperative CDVA improved in both the myopic eyes to 0.16 ± 0.37 logMAR, as in the hyperopic eyes to − 0.10 ± 0.55 logMAR with no eyes having loss of Snellen lines. Mean postoperative spherical equivalent was − 0.34 ± 0.72 D and − 0.10 ± 0.55 D, respectively. ECD loss 6 months after surgery was 5% and remained stable thereafter. Conclusion: SIT for combined phacoemulsification and IF-pIOL removal yields good visual and refractive results and is a safe procedure in regard to ECD loss. The technique has advantages over the conventional procedure and is easy to perform.
- 16 October 2021
- Published by Springer Nature in Graefe's Archive for Clinical and Experimental Ophthalmology
- Vol. 260 (4) , 1367-1375
Open AccessTwo-year results after combined phacoemulsification and iris-fixated phakic intraocular lens removal
Purpose: To describe and present results after a technique for cataract surgery combined with explantation of an iris-fixated phakic intraocular lens (IF-pIOL). Methods: The medical records of all patients, who had undergone cataract surgery combined with IF-pIOL explantation and subsequent implantation of a posterior chamber IOL by the Single Incision Technique (SIT), were reviewed. Data collection included preoperative and postoperative corrected distance visual acuity (CDVA), manifest refraction, and endothelial cell density (ECD) up to a follow-up time of 24 months. Results: Fifty myopic eyes (34 patients) and 9 hyperopic eyes (6 patients) had undergone a SIT procedure mainly because of cataract (67%). Postoperative CDVA improved in both the myopic eyes to 0.16 ± 0.37 logMAR, as in the hyperopic eyes to − 0.10 ± 0.55 logMAR with no eyes having loss of Snellen lines. Mean postoperative spherical equivalent was − 0.34 ± 0.72 D and − 0.10 ± 0.55 D, respectively. ECD loss 6 months after surgery was 5% and remained stable thereafter. Conclusion: SIT for combined phacoemulsification and IF-pIOL removal yields good visual and refractive results and is a safe procedure in regard to ECD loss. The technique has advantages over the conventional procedure and is easy to perform.
- Open Access
- 29 October 2020
- Published by Wiley in Acta Ophthalmologica
- Vol. 99 (4) , E562-E568
Long‐term longitudinal changes in axial length in the Caucasian myopic and hyperopic population with a phakic intraocular lens
Purpose: To determine the long‐term longitudinal axial length changes in myopic and hyperopic adults with an iris‐fixated phakic intraocular lens (pIOL).Methods: The medical records of patients aged ≥18 years with myopia or hyperopia who were treated with pIOL implantation between 1996 and 2011 for refractive correction with a minimum follow‐up of 5 years after pIOL implantation were analyzed. The main outcome measure was change in ocular axial length over time.Results: 149 eyes of 149 myopic patients and 27 hyperopic eyes of 27 patients were included in this study. Mean patient age was 37.1 ± 10.4 years (35% male) in the myopic group and 39.4 ± 9.4 years (4% male) in the hyperopic group. The eyes of the myopic patients showed a significant mean increase in axial length of 0.45 ± 0.61 mm after a mean follow‐up time of 144 ± 38 months (p < 0.001). In 26 eyes (17%), the axial length had increased by ≥1 mm. The mean annual axial length increase was 0.04 ± 0.06 mm. Axial elongation was associated with a higher degree of myopia (p < 0.001) and younger age (p = 0.02). The eyes of the hyperopic patients showed no change in axial length over time.Conclusions: Myopic eyes corrected with an iris‐fixated pIOL show continuous increase in axial length at an adult age. Although this study is limited to subjects with a pIOL, this is the first time myopization in Caucasian adults has been reported in a large long‐term longitudinal study.
- 29 October 2020
- Published by Wiley in Acta Ophthalmologica
- Vol. 99 (4) , E562-E568
Open AccessLong‐term longitudinal changes in axial length in the Caucasian myopic and hyperopic population with a phakic intraocular lens
Purpose: To determine the long‐term longitudinal axial length changes in myopic and hyperopic adults with an iris‐fixated phakic intraocular lens (pIOL).Methods: The medical records of patients aged ≥18 years with myopia or hyperopia who were treated with pIOL implantation between 1996 and 2011 for refractive correction with a minimum follow‐up of 5 years after pIOL implantation were analyzed. The main outcome measure was change in ocular axial length over time.Results: 149 eyes of 149 myopic patients and 27 hyperopic eyes of 27 patients were included in this study. Mean patient age was 37.1 ± 10.4 years (35% male) in the myopic group and 39.4 ± 9.4 years (4% male) in the hyperopic group. The eyes of the myopic patients showed a significant mean increase in axial length of 0.45 ± 0.61 mm after a mean follow‐up time of 144 ± 38 months (p < 0.001). In 26 eyes (17%), the axial length had increased by ≥1 mm. The mean annual axial length increase was 0.04 ± 0.06 mm. Axial elongation was associated with a higher degree of myopia (p < 0.001) and younger age (p = 0.02). The eyes of the hyperopic patients showed no change in axial length over time.Conclusions: Myopic eyes corrected with an iris‐fixated pIOL show continuous increase in axial length at an adult age. Although this study is limited to subjects with a pIOL, this is the first time myopization in Caucasian adults has been reported in a large long‐term longitudinal study.
- Open Access
- 6 August 2020
- Published by Springer Nature in Graefe's Archive for Clinical and Experimental Ophthalmology
- Vol. 259 (1) , 231-238
Differences between Scheimpflug and optical coherence tomography in determining safety distances in eyes with an iris-fixating phakic intraocular lens
Purpose: To investigate the agreement and reliability of anterior segment optical coherence tomography (AS-OCT) and Scheimpflug imaging in measuring the distance from the anterior edge of an iris-fixated phakic intraocular lens (IF-pIOL) to the corneal endothelium. Methods: Anterior segment configuration was assessed in a total of 62 eyes of which 25 hyperopic and 37 myopic eyes, all corrected with an IF-pIOL. Measurements were performed by two independent observers using AS-OCT (Visante, Model 1000, Carl Zeiss Meditec Inc.) and Scheimpflug imaging (Pentacam HR, Oculus Optikgerate). The distance from the anterior edge of the pIOL to the endothelium was measured in five different positions using both modalities with their corresponding pIOL software. The measurements as well as the inter- and intra-observer reliability of the two imaging modalities were then compared. Results: Distance measurements for all positions performed by AS-OCT were found to be significantly larger than those performed by Scheimpflug imaging, with mean differences ranging from 0.11 to 0.22 mm. Both instruments exhibited good inter- and intra-observer reliability. Conclusion: Anterior pIOL edge to endothelium distance measurements by AS-OCT and Scheimpflug imaging have good intra- and inter-observer reliability. However, as AS-OCT provides larger measurements, these two modalities cannot be used interchangeably. Correction of this difference might be essential for proper decision-making during pre-operative screening for pIOL implantation and post-operative safety monitoring.
- 6 August 2020
- Published by Springer Nature in Graefe's Archive for Clinical and Experimental Ophthalmology
- Vol. 259 (1) , 231-238
Open AccessDifferences between Scheimpflug and optical coherence tomography in determining safety distances in eyes with an iris-fixating phakic intraocular lens
Purpose: To investigate the agreement and reliability of anterior segment optical coherence tomography (AS-OCT) and Scheimpflug imaging in measuring the distance from the anterior edge of an iris-fixated phakic intraocular lens (IF-pIOL) to the corneal endothelium. Methods: Anterior segment configuration was assessed in a total of 62 eyes of which 25 hyperopic and 37 myopic eyes, all corrected with an IF-pIOL. Measurements were performed by two independent observers using AS-OCT (Visante, Model 1000, Carl Zeiss Meditec Inc.) and Scheimpflug imaging (Pentacam HR, Oculus Optikgerate). The distance from the anterior edge of the pIOL to the endothelium was measured in five different positions using both modalities with their corresponding pIOL software. The measurements as well as the inter- and intra-observer reliability of the two imaging modalities were then compared. Results: Distance measurements for all positions performed by AS-OCT were found to be significantly larger than those performed by Scheimpflug imaging, with mean differences ranging from 0.11 to 0.22 mm. Both instruments exhibited good inter- and intra-observer reliability. Conclusion: Anterior pIOL edge to endothelium distance measurements by AS-OCT and Scheimpflug imaging have good intra- and inter-observer reliability. However, as AS-OCT provides larger measurements, these two modalities cannot be used interchangeably. Correction of this difference might be essential for proper decision-making during pre-operative screening for pIOL implantation and post-operative safety monitoring.
- 20 November 2019
- Published by Wolters Kluwer Health in Journal of Cataract & Refractive Surgery
- Vol. 46 (1) , 125-137
Middle- and long-term results after iris-fixated phakic intraocular lens implantation in myopic and hyperopic patients: a meta-analysis
The iris-fixated phakic intraocular lens (pIOL) has been available for over 25 years. To provide a clear picture of outcomes and risks, for this systematic review and meta-analysis, the literature was searched for reports on middle- and long-term effects. The iris-fixated phakic intraocular lens (pIOL) has been available for over 25 years. To provide a clear picture of outcomes and risks, for this systematic review and meta-analysis, the literature was searched for reports on middle- and long-term effects of iris-fixated pIOLs on myopic and hyperopic eyes with a follow-up of at least 2 to 4 years. Visual and refractive results after implantation for correction of myopia are positive and the complication rate is low. Endothelial cell loss appears to be at an acceptable rate, although the range of endothelial cell change is too wide to draw firm conclusions. Care should be taken when considering an iris-fixated pIOL for hyperopic eyes because complication rates, particularly pigment dispersion, might be higher than those in myopic eyes. More well-designed, long-term studies are needed, especially in hyperopic eyes. The authors advocate for standardized reporting of refractive surgery data. Initiatives proposed by journal authors and editors to achieve uniformity should be supported.
- 20 November 2019
- Published by Wolters Kluwer Health in Journal of Cataract & Refractive Surgery
- Vol. 46 (1) , 125-137
Middle- and long-term results after iris-fixated phakic intraocular lens implantation in myopic and hyperopic patients: a meta-analysis
The iris-fixated phakic intraocular lens (pIOL) has been available for over 25 years. To provide a clear picture of outcomes and risks, for this systematic review and meta-analysis, the literature was searched for reports on middle- and long-term effects. The iris-fixated phakic intraocular lens (pIOL) has been available for over 25 years. To provide a clear picture of outcomes and risks, for this systematic review and meta-analysis, the literature was searched for reports on middle- and long-term effects of iris-fixated pIOLs on myopic and hyperopic eyes with a follow-up of at least 2 to 4 years. Visual and refractive results after implantation for correction of myopia are positive and the complication rate is low. Endothelial cell loss appears to be at an acceptable rate, although the range of endothelial cell change is too wide to draw firm conclusions. Care should be taken when considering an iris-fixated pIOL for hyperopic eyes because complication rates, particularly pigment dispersion, might be higher than those in myopic eyes. More well-designed, long-term studies are needed, especially in hyperopic eyes. The authors advocate for standardized reporting of refractive surgery data. Initiatives proposed by journal authors and editors to achieve uniformity should be supported.
- Open Access
- 1 November 2019
- Published by Taylor & Francis in Clinical Ophthalmology
- Vol. ume 13, 2195-2201
Straylight As The Result Of Refractive Correction
Purpose: To investigate the effect of refractive correction on straylight. Patients and methods: Straylight values were measured with the C-Quant (Oculus Optikgeräte, GmbH, Wetzlar, Germany) in 1) near-emmetropic eyes (n=30) with various negative powered refractive lenses and in 2) myopic eyes (n=30) corrected with prescribed eyeglasses and contact lenses. The straylight measurements in each group were compared in the different conditions. Results: In the near-emmetropic group, a significant effect (pConclusion: Refractive correction with high minus power (contact) lenses result in subtle increase of straylight values. These changes are relatively small and do not lead to visual disability in a clinical setting.
- 1 November 2019
- Published by Taylor & Francis in Clinical Ophthalmology
- Vol. ume 13, 2195-2201
Open AccessStraylight As The Result Of Refractive Correction
Purpose: To investigate the effect of refractive correction on straylight. Patients and methods: Straylight values were measured with the C-Quant (Oculus Optikgeräte, GmbH, Wetzlar, Germany) in 1) near-emmetropic eyes (n=30) with various negative powered refractive lenses and in 2) myopic eyes (n=30) corrected with prescribed eyeglasses and contact lenses. The straylight measurements in each group were compared in the different conditions. Results: In the near-emmetropic group, a significant effect (pConclusion: Refractive correction with high minus power (contact) lenses result in subtle increase of straylight values. These changes are relatively small and do not lead to visual disability in a clinical setting.
- 6 August 2019
- Published by Wiley in Acta Ophthalmologica
- Vol. 97 (8) , 735-743
Correlations between ocular biometrics and refractive error: A systematic review and meta‐analysis
The understanding of correlations between different biometric parameters is essential for personalized eye care in the field of cataract and refractive surgery. This systematic review offers a clear overview of the previous literature assessing these correlations including a meta‐analysis. The review is focused on the following five correlations: (1) axial length and refractive error; (2) anterior chamber depth and refractive error; (3) axial length and anterior chamber depth; (4) corneal power and refractive error; (5) corneal power and axial length. An expected strong correlation between axial length and refractive error was found. Correlations including corneal power were weak and might be clinically insignificant.
- 6 August 2019
- Published by Wiley in Acta Ophthalmologica
- Vol. 97 (8) , 735-743
Correlations between ocular biometrics and refractive error: A systematic review and meta‐analysis
The understanding of correlations between different biometric parameters is essential for personalized eye care in the field of cataract and refractive surgery. This systematic review offers a clear overview of the previous literature assessing these correlations including a meta‐analysis. The review is focused on the following five correlations: (1) axial length and refractive error; (2) anterior chamber depth and refractive error; (3) axial length and anterior chamber depth; (4) corneal power and refractive error; (5) corneal power and axial length. An expected strong correlation between axial length and refractive error was found. Correlations including corneal power were weak and might be clinically insignificant.