Pete Bridge
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Research Interests
Pete Bridge has a total of 175 co-authors. Here are the top co-authors by number of shared publications:
- Mary-Ann Carmichael
Queensland University of Technology
12 shared publications - Mark Warren
School of Health Sciences, University of Liverpool, Liverpool, UK
5 shared publications - Andrew L. Fielding
School of Chemistry and Physics, Queensland University of Technology, Brisbane, Australia
4 shared publications Andrew Pullar
Radiation Oncology Mater Centre, Brisbane, QLD, Australia
4 shared publications- Pamela Rowntree
School of Clinical Sciences, Faculty of Health, Queensland University of Technology (QUT), Brisbane, QLD, Australia
4 shared publications M. Kirby
School of Health Sciences, University of Liverpool, Brownlow Hill, Liverpool L69 3BX, UK
3 shared publications
Latest Publications
- 15 March 2026
- Published by Liverpool University Press in Developing Academic Practice
- Vol. 2026 (March) , 1-11
Undergraduate ‘shut up and write’ formative feedback: Boosting productivity and enhancing writing skills
Background: In higher education undergraduate teaching, ‘shut up and write’ (SUAW) sessions have gained popularity as a strategy to enhance students’ productivity and writing skills. These structured sessions provide a supportive environment where students can focus on their writing tasks, minimizing distractions and maximizing their output. Methods and materials: This project aimed to evaluate the impact of SUAW sessions on Year 2 therapeutic radiography students as they developed research proposals for a summative module assessment. Two whole-day sessions were booked on campus six weeks apart with a staff:student ratio of 1:10. A survey method gathered Likert-style quantitative data and open textual data using a short paper-based questionnaire in the room at the end of the last session. Results: The surveys received fifty-five responses. Students enjoyed the SUAW sessions and felt they helped with assignment writing and time management. Many comments indicated that students had engaged with assessment earlier than they would have normally. Module assessment marks compared favourably with those of the previous year. Conclusion: The SUAW format was well received by students who found the sessions to be enjoyable and useful. Recommendations include extending the number of planned sessions and increasing the staff:student ratio. Future work should investigate what additional support this initiative can provide specifically to international students. This article was published open access under a CC BY licence: https://creativecommons.org/licenses/by/4.0/ .
- 15 March 2026
- Published by Liverpool University Press in Developing Academic Practice
- Vol. 2026 (March) , 1-11
Undergraduate ‘shut up and write’ formative feedback: Boosting productivity and enhancing writing skills
Background: In higher education undergraduate teaching, ‘shut up and write’ (SUAW) sessions have gained popularity as a strategy to enhance students’ productivity and writing skills. These structured sessions provide a supportive environment where students can focus on their writing tasks, minimizing distractions and maximizing their output. Methods and materials: This project aimed to evaluate the impact of SUAW sessions on Year 2 therapeutic radiography students as they developed research proposals for a summative module assessment. Two whole-day sessions were booked on campus six weeks apart with a staff:student ratio of 1:10. A survey method gathered Likert-style quantitative data and open textual data using a short paper-based questionnaire in the room at the end of the last session. Results: The surveys received fifty-five responses. Students enjoyed the SUAW sessions and felt they helped with assignment writing and time management. Many comments indicated that students had engaged with assessment earlier than they would have normally. Module assessment marks compared favourably with those of the previous year. Conclusion: The SUAW format was well received by students who found the sessions to be enjoyable and useful. Recommendations include extending the number of planned sessions and increasing the staff:student ratio. Future work should investigate what additional support this initiative can provide specifically to international students. This article was published open access under a CC BY licence: https://creativecommons.org/licenses/by/4.0/ .
- Open Access
- 11 April 2025
- Published by Cambridge University Press (CUP) in Journal of Radiotherapy in Practice
- Vol. 24, e15
A systematic review of open face versus mask less surface guided radiotherapy for patients undergoing radiotherapy for head, neck and brain tumours
Introduction: Accurate delivery of radiotherapy to head, neck and brain cancer relies on the use of sophisticated immobilisation devices, usually using a restrictive thermoplastic mask. These masks can cause anxiety and can make treatment difficult for many patients. Open-face or maskless techniques are alternatives which can improve the patient experience. This systematic review aimed to compare the effectiveness of open-face (OF) masks and maskless surface guided radiotherapy (SGRT) with conventional masks. Method: Primary research papers from the last 10 years were gathered from Scopus, PUBMED, Web of Science and OVID databases. Quantitative data reporting interfractional set-up errors and intrafractional patient motion were extracted from included studies and subjected to descriptive statistical analysis. Additional qualitative data relating to patient tolerance were also extracted to inform discussion. Results: Ten studies were identified for inclusion. The data identified that OF masks can reproduce patient set-up with an accuracy of <2 mm and <1° and can restrict movement to <1 mm and 0·4°, while maskless SGRT can achieve accuracy to within 0·05 mm and 0·1°. Conclusion: This review indicates comparable reduction of intrafractional motion between conventional masks, Open-Face masks and maskless SGRT techniques. More research is needed into the impact of maskless SGRT techniques on translational and rotational motions compared to traditional masks.
- 11 April 2025
- Published by Cambridge University Press (CUP) in Journal of Radiotherapy in Practice
- Vol. 24, e15
Open AccessA systematic review of open face versus mask less surface guided radiotherapy for patients undergoing radiotherapy for head, neck and brain tumours
Introduction: Accurate delivery of radiotherapy to head, neck and brain cancer relies on the use of sophisticated immobilisation devices, usually using a restrictive thermoplastic mask. These masks can cause anxiety and can make treatment difficult for many patients. Open-face or maskless techniques are alternatives which can improve the patient experience. This systematic review aimed to compare the effectiveness of open-face (OF) masks and maskless surface guided radiotherapy (SGRT) with conventional masks. Method: Primary research papers from the last 10 years were gathered from Scopus, PUBMED, Web of Science and OVID databases. Quantitative data reporting interfractional set-up errors and intrafractional patient motion were extracted from included studies and subjected to descriptive statistical analysis. Additional qualitative data relating to patient tolerance were also extracted to inform discussion. Results: Ten studies were identified for inclusion. The data identified that OF masks can reproduce patient set-up with an accuracy of <2 mm and <1° and can restrict movement to <1 mm and 0·4°, while maskless SGRT can achieve accuracy to within 0·05 mm and 0·1°. Conclusion: This review indicates comparable reduction of intrafractional motion between conventional masks, Open-Face masks and maskless SGRT techniques. More research is needed into the impact of maskless SGRT techniques on translational and rotational motions compared to traditional masks.
- Open Access
- 20 March 2025
- Published by Cambridge University Press (CUP) in Journal of Radiotherapy in Practice
- Vol. 24, e9
Vacuum erectile devices for managing erectile dysfunction for those receiving radical prostate radiotherapy and androgen deprivation therapy: a user evaluation
Introduction: Radiotherapy with androgen deprivation therapy (ADT) is the standard of care for locally advanced prostate cancer but causes erectile dysfunction (ED). Vacuum erectile devices (VED)s are a first-line treatment for ED along with phosphodiesterase-5 inhibitors (PDE5-Is), yet all evidence supporting their use arises from post-surgical ED. This study aimed to assess effectiveness of VEDs for patients with ED resulting from radiotherapy and ADT. Methods: This service evaluation utilised a longitudinal survey method to gather ED scores at baseline, after commencing ADT and after receiving a VED. Patients who were undergoing ADT for prostate cancer either before or alongside radical radiotherapy and who had been referred to receive a VED were invited to participate. Data including how patients used the VED, psychosexual counselling and PDE5-Is were also collected. Thematic analysis was used to identify men’s perceptions of the VEDs. Results: Data from the 15 participants demonstrated statistically significant treatment-related ED but failed to determine impact of VED on this. Qualitative data identified that participants found the VEDs to be unhelpful, too clinical, unappealing, emasculating and frustrating to use. Limited data suggested that VEDs are more effective at treating ED when used in combination with PDE5-Is. Conclusion: Patients in this small sample generally reported dissatisfaction with VED usage. Limited engagement with the study frustrated attempts to draw conclusions regarding the effectiveness of VEDs for radiotherapy patients suffering from ED during ADT and a larger national study should be conducted to establish this. Improvements to the care pathway and access to psychosexual counselling are recommended.
- 20 March 2025
- Published by Cambridge University Press (CUP) in Journal of Radiotherapy in Practice
- Vol. 24, e9
Open AccessVacuum erectile devices for managing erectile dysfunction for those receiving radical prostate radiotherapy and androgen deprivation therapy: a user evaluation
Introduction: Radiotherapy with androgen deprivation therapy (ADT) is the standard of care for locally advanced prostate cancer but causes erectile dysfunction (ED). Vacuum erectile devices (VED)s are a first-line treatment for ED along with phosphodiesterase-5 inhibitors (PDE5-Is), yet all evidence supporting their use arises from post-surgical ED. This study aimed to assess effectiveness of VEDs for patients with ED resulting from radiotherapy and ADT. Methods: This service evaluation utilised a longitudinal survey method to gather ED scores at baseline, after commencing ADT and after receiving a VED. Patients who were undergoing ADT for prostate cancer either before or alongside radical radiotherapy and who had been referred to receive a VED were invited to participate. Data including how patients used the VED, psychosexual counselling and PDE5-Is were also collected. Thematic analysis was used to identify men’s perceptions of the VEDs. Results: Data from the 15 participants demonstrated statistically significant treatment-related ED but failed to determine impact of VED on this. Qualitative data identified that participants found the VEDs to be unhelpful, too clinical, unappealing, emasculating and frustrating to use. Limited data suggested that VEDs are more effective at treating ED when used in combination with PDE5-Is. Conclusion: Patients in this small sample generally reported dissatisfaction with VED usage. Limited engagement with the study frustrated attempts to draw conclusions regarding the effectiveness of VEDs for radiotherapy patients suffering from ED during ADT and a larger national study should be conducted to establish this. Improvements to the care pathway and access to psychosexual counselling are recommended.
- Open Access
- 11 February 2025
- Published by Springer Nature in BMC Digital Health
- Vol. 3 (1) , 1-8
Evaluation of a novel interactive virtual reality environment for mindfulness skills training
- 11 February 2025
- Published by Springer Nature in BMC Digital Health
- Vol. 3 (1) , 1-8
Open AccessEvaluation of a novel interactive virtual reality environment for mindfulness skills training
- Open Access
- 8 November 2024
- Published by Taylor & Francis in Cogent Education
- Vol. 11 (1)
Implementing gamification within interprofessional learning: perspectives of Higher Education staff and students
- 8 November 2024
- Published by Taylor & Francis in Cogent Education
- Vol. 11 (1)
Open AccessImplementing gamification within interprofessional learning: perspectives of Higher Education staff and students
- Open Access
- 23 March 2024
- Published by Elsevier in Nurse Education Today
- Vol. 138, 106184
A virtual reality environment for supporting mental wellbeing of students on remote clinical placement: A multi-methods evaluation
- 23 March 2024
- Published by Elsevier in Nurse Education Today
- Vol. 138, 106184
Open AccessA virtual reality environment for supporting mental wellbeing of students on remote clinical placement: A multi-methods evaluation
- Open Access
- 17 January 2024
- Published by Elsevier in Radiography
- Vol. 30 (2) , 500-503
Evaluating the impact of training on therapeutic radiographer awareness of the signs and symptoms of neutropenic sepsis in patients undergoing concurrent chemoradiotherapy
- 17 January 2024
- Published by Elsevier in Radiography
- Vol. 30 (2) , 500-503
Open AccessEvaluating the impact of training on therapeutic radiographer awareness of the signs and symptoms of neutropenic sepsis in patients undergoing concurrent chemoradiotherapy
- Open Access
- 9 January 2024
- Published by Elsevier in Radiography
- Vol. 30 (2) , 425-430
Clinical indications for carbon-ion radiotherapy in the UK: A critical review
- 9 January 2024
- Published by Elsevier in Radiography
- Vol. 30 (2) , 425-430
Open AccessClinical indications for carbon-ion radiotherapy in the UK: A critical review
- Open Access
- 28 April 2023
- Published by Elsevier in Radiography
- Vol. 29 (4) , 684-689
Post COVID-19 trends in simulation use within diagnostic radiography and radiation therapy education
- 28 April 2023
- Published by Elsevier in Radiography
- Vol. 29 (4) , 684-689
Open AccessPost COVID-19 trends in simulation use within diagnostic radiography and radiation therapy education
- Open Access
- 28 April 2023
- Published by Cambridge University Press (CUP) in Journal of Radiotherapy in Practice
- Vol. 22, e95
The impact of 3D stereoscopic visualisation on performance in electron skin apposition techniques using VERT
Introduction: The Virtual Environment for Radiotherapy Training (VERT) is a simulator used to train radiotherapy students cost-effectively with limited risk. VERT is available as a two-dimensional (2D) and a more costly three-dimensional (3D) stereoscopic resource. This study aimed to identify the specific benefits afforded by stereoscopic visualisation for student training in skin apposition techniques. Method: Eight participants completed six electron skin apposition setups in both 2D and 3D views of VERT using a 7 cm × 10 cm rectangular applicator setup to 100 cm focus skin distance (FSD). The standard deviation (SD) of the mean distance from each corner of the applicator to the virtual patient’s skin surface [which we define as apposition precision (AP)] was measured along with the time taken to achieve each setup. Participants then completed a four-question Likert-style questionnaire concerning their preferences and perceptions of the 2D and 3D views. Results: There was little difference in mean setup times with 218·43 seconds for 2D and 211·29 seconds for 3D (3·3% difference). There was a similarly small difference in AP with a mean SD of 5·61 mm for 2D and 5·79 mm for 3D (3·2% difference) between views. The questionnaire results showed no preference for the 3D view over the 2D. Conclusion: These findings suggest that the 2D and 3D views result in similar setup times and precision, with no user preference for the 3D view. It is recommended that the 2D version of VERT could be utilised in similar situations with a reduced logistical and financial impact.
- 28 April 2023
- Published by Cambridge University Press (CUP) in Journal of Radiotherapy in Practice
- Vol. 22, e95
Open AccessThe impact of 3D stereoscopic visualisation on performance in electron skin apposition techniques using VERT
Introduction: The Virtual Environment for Radiotherapy Training (VERT) is a simulator used to train radiotherapy students cost-effectively with limited risk. VERT is available as a two-dimensional (2D) and a more costly three-dimensional (3D) stereoscopic resource. This study aimed to identify the specific benefits afforded by stereoscopic visualisation for student training in skin apposition techniques. Method: Eight participants completed six electron skin apposition setups in both 2D and 3D views of VERT using a 7 cm × 10 cm rectangular applicator setup to 100 cm focus skin distance (FSD). The standard deviation (SD) of the mean distance from each corner of the applicator to the virtual patient’s skin surface [which we define as apposition precision (AP)] was measured along with the time taken to achieve each setup. Participants then completed a four-question Likert-style questionnaire concerning their preferences and perceptions of the 2D and 3D views. Results: There was little difference in mean setup times with 218·43 seconds for 2D and 211·29 seconds for 3D (3·3% difference). There was a similarly small difference in AP with a mean SD of 5·61 mm for 2D and 5·79 mm for 3D (3·2% difference) between views. The questionnaire results showed no preference for the 3D view over the 2D. Conclusion: These findings suggest that the 2D and 3D views result in similar setup times and precision, with no user preference for the 3D view. It is recommended that the 2D version of VERT could be utilised in similar situations with a reduced logistical and financial impact.